Search results

1 – 10 of over 2000
Article
Publication date: 17 April 2023

Grzegorz Kostro, Michal Michna, Filip Kutt and Roland Ryndzionek

Calculating the stator end-winding leakage inductance, taking into account the rotor, is difficult due to the irregular shape of the end-winding. The end-winding leakage may…

Abstract

Purpose

Calculating the stator end-winding leakage inductance, taking into account the rotor, is difficult due to the irregular shape of the end-winding. The end-winding leakage may distribute at the end of the active part and the fringing flux of the air gap. The fringing flux belongs to the main flux but goes into the end-winding region. Then, not all the magnetic flux occurring in the end region is the end-winding leakage flux. The purpose of this paper was to find a method to accurately separate the leakage from the total flux, taking into account the rotor.

Design/methodology/approach

In this paper, two methods based on energy calculation are presented. Both methods require the assumption that the machine is symmetrical. The first method depends on the total leakage inductance and the machine’s active region length. The second method is based on the energy stored in the end region of the machine. In this case, removing the energy produced by the fringing flux of the air gap is necessary. The model should have a volume-closing fringing flux to remove the part of energy belonging to the end of the air gap.

Findings

The method presented in the paper does not require rotor removal. The values of the end-winding leakage inductance computed based on the proposed method were compared with values computed using the method with the removed rotor. The computations show that the proposed method is closest to the results from the method presented in the literature. Results obtained in the first method present that rotor influence on the value of end-winding leakage inductance exists. The model of the stator end-winding described in the paper is general. Therefore, the proposed methods are suitable for calculating the end-winding leakage inductance of other electric machines.

Originality/value

The method presented in the paper considers the rotor in end-winding leakage inductance calculation. It is not necessary to remove the rotor as in the similar method presented in the literature. The authors elaborated a parametric model with a volume-closing fringing flux to remove the part of energy belonging to the end of the air gap. The authors also elaborated their 3D model of the machine winding for calculations in Opera 3D.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. 42 no. 4
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 1 April 2024

Ali Hashemi, Parsa Yazdanpanah Qaraei and Mostafa Shabanian-Poodeh

The aim of this paper is to provide a simple yet accurate and efficient geometric method for thermal homogenization of impregnated and non-impregnated coil winding technologies…

Abstract

Purpose

The aim of this paper is to provide a simple yet accurate and efficient geometric method for thermal homogenization of impregnated and non-impregnated coil winding technologies based on the concept of thermal resistance.

Design/methodology/approach

For regular windings, the periodic microscopic cell in the winding space is identified. Also, for irregular windings, the average microscopic cell of the winding is determined. An approximation is used to calculate the thermal resistance of the winding cell. Based on this approximation, the winding insulation is considered as a circular ring around the wire. Mathematical equations are obtained to calculate the equivalent thermal resistance of the cell. The equivalent thermal conductivity of the winding is calculated using equivalent thermal resistance of the cell. Winding thermal homogenization is completed by determining the equivalent thermal properties of the cell.

Findings

The thermal pattern of different windings is simulated and compared with the results of different homogenization methods. The results show that the proposed method is applicable for a wide range of windings in terms of winding scheme, packing factor and winding insulation. Also, the results show that the proposed method is more accurate than other winding homogenization methods in calculating the equivalent thermal conductivity of the winding.

Research limitations/implications

In this paper, the change of electrical resistance of the winding with temperature and thermal contact between the sub-components are ignored. Also, liquid insulators, such as oils, and rectangular wires were not investigated. Research in these topics is considered as future work.

Originality/value

Unlike other homogenization methods, the proposed method can be applied to non-impregnated and irregular windings. Also, compared to other homogenization methods, the proposed method has a simpler formulation that makes it easier to program and implement. All of these indicate the efficiency of the proposed method in the thermal analysis of the winding.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 15 February 2024

Ali Hashemi, Hamed Taheri and Mohammad Dehghani

To prevent the coil from burning or getting damaged, it is necessary to estimate the duration of its operation as long as its temperature does not exceed the permissible limit…

Abstract

Purpose

To prevent the coil from burning or getting damaged, it is necessary to estimate the duration of its operation as long as its temperature does not exceed the permissible limit. This paper aims to investigate the effect of switching on the thermal behavior of impregnated and nonimpregnated windings. Also, the safe operating time for each winding is determined.

Design/methodology/approach

The power loss of the winding is expressed as a function of the winding specifications. Using homogenization techniques, the equivalent thermal properties for the homogenized winding are calculated and used in a proposed thermal equivalent circuit for winding modeling and analysis. The validity and accuracy of the proposed model are determined by comparing its analysis results and simulation and measurement results.

Findings

The results show that copper windings have better thermal behavior and lower temperature compared to aluminum windings. On the other hand, by impregnating or increasing the packing factor of the winding, the thermal behavior is improved. Also, by choosing the right duty cycle for the winding current source, it is possible to prevent the burning or damage of the winding and increase its lifespan. Comparing the measurement results with the analysis results shows that the proposed equivalent circuit has an error of less than 4% in the calculation of the winding center temperature.

Research limitations/implications

In this paper, the effect of temperature on the electrical resistance of the coil is ignored. Also, rectangular wires were not investigated. Research in these topics are considered as future work.

Originality/value

By calculating the thermal time constant of the winding, its safe operation time can be calculated so that its temperature does not exceed the tolerable value (150 °C). The proposed method analyzes both impregnated and nonimpregnated windings with various schemes. It investigates the effects of switching on their thermal behavior. Additionally, it determines the safe operating time for each type of winding.

Details

World Journal of Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 25 April 2023

Ali Hashemi, Parsa Yazdanpanah Qaraei and Mostafa Shabanian

An excessive increase in temperature will reduce the lifespan and even burn the coil. The variety of materials in the structure of the electromagnet along with its multi-layer…

Abstract

Purpose

An excessive increase in temperature will reduce the lifespan and even burn the coil. The variety of materials in the structure of the electromagnet along with its multi-layer winding creates a complex and heterogeneous thermal structure. There are very few researches that are completely focused on the thermal analysis of electromagnets. The purpose of this paper is to provide an accurate, yet fast and simple method for the thermal analysis of cylindrical electromagnets in both transient and steady-state modes. For this purpose, a thermal equivalent circuit (TEC) is presented based on the nodding approach.

Design/methodology/approach

The results of TEC analysis of cylindrical electromagnet, for two orthogonal and orthocyclic winding coil technologies, were compared with the results of the thermal simulation in COMSOL. The authors also built a laboratory model of the cylindrical electromagnet, similar to those analyzed and simulated, and measured the temperature in different parts of it.

Findings

The comparison of the results obtained from different methods for the thermal analysis of the cylindrical electromagnet indicates that the proposed TEC has an error of less than 2%. The simplicity and high accuracy of the results are the most important advantages of the proposed TEC.

Originality/value

Comparing the information and results related to winding schemes, indicates that the orthogonal winding has less cost and weight due to the shorter length of the wire used. On the other hand, orthocyclic winding generates lower temperature and has more lifting force, and is simpler to implement. Therefore, in practice, orthocyclic winding technology is usually used.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. 42 no. 6
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 16 February 2024

Abdallah Chanane and Hamza Houassine

Although, numerous optimization algorithms have been devoted to construct an electrical ladder network model (ELNM), they suffer from some frail points such as insufficient…

Abstract

Purpose

Although, numerous optimization algorithms have been devoted to construct an electrical ladder network model (ELNM), they suffer from some frail points such as insufficient accuracy as well as the majority of them are unconstrained, which result in optimal solutions that violate certain security operational constraints. For this purpose, this paper aims to propose a flexible-constraint coyote optimization algorithm; the novelty lies in these points: penalty function is introduced in the objective function to discard any unfeasible solution, an advanced constraint handling technique and empirical relationship between the physical estimated parameters and their natural frequencies.

Design/methodology/approach

Frequency response analysis (FRA) is very significant for transformer winding diagnosis. Interpreting results of a transformer winding FRA is quite challenging. This paper proposes a new methodology to synthesize a nearly unique ELNM physically and electrically coupled for power transformer winding, basing on K-means and metaheuristic algorithm. To this end, the K-means method is used to cluster the setting of control variables, including the self-mutual inductances/capacitances, and the resistances parameters. Afterward, metaheuristic algorithm is applied to determine the cluster centers with high precision and efficiency.

Findings

FRA is performed on a power transformer winding model. Basing on the proposed methodology, the prior knowledge in selecting the initial guess and search space is avoided and the global solution is ensured. The performance of the abovementioned methodology is compared using evaluation expressions to verify its feasibility and accuracy.

Originality/value

The proposed method could be generalized for diagnosis of faults in power transformer winding.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. 43 no. 1
Type: Research Article
ISSN: 0332-1649

Keywords

Open Access
Article
Publication date: 23 May 2023

Roland Ryndzionek, Michal Michna, Filip Kutt, Grzegorz Kostro and Krzysztof Blecharz

The purpose of this paper is to provide an analysis of the performance of a new five-phase doubly fed induction generator (DFIG).

Abstract

Purpose

The purpose of this paper is to provide an analysis of the performance of a new five-phase doubly fed induction generator (DFIG).

Design/methodology/approach

This paper presents the results of a research work related to five-phase DFIG framing, including the development of an analytical model, FEM analysis as well as the results of laboratory tests of the prototype. The proposed behavioral level analytical model is based on the winding function approach. The developed DFIG model was used at the design stage to simulate the generator’s no-load and load state. Then, the results of the FEM analysis were shown and compared with the results of laboratory tests of selected DFIG operating states.

Findings

The paper provides the results of analytical and FEM simulation and measurement tests of the new five-phase dual-feed induction generator. The use of the MATLAB Simscape modeling language allows for easy and quick implementation of the model. Design assumptions and analytical model-based analysis have been verified using FEM analysis and measurements performed on the prototype. The results of the presented research validate the design process as well as show the five-phase winding design advantage over the three-phase solution regarding the control winding power quality.

Research limitations/implications

The main disadvantage of the winding function approach-based model development is the simplification regarding omitting the tangential airgap flux density component. However, this fault only applies to large airgap machines and is insignificant in induction machines. The results of the DFIG analyses were limited to the basic operating states of the generator, i.e. the no-load state, the inductive and resistive load.

Practical implications

The novel DFIG with five phase rotor control winding can operate as a regular three-phase machine in an electric power generation system and allows for improved control winding power quality of the proposed electrical energy generation system. This increase in power quality is due to the rotor control windings inverter-based PWM supply voltage, which operates with a wider per-phase supply voltage range than a three-phase system. This phenomenon was quantified using control winding current harmonic analysis.

Originality/value

The paper provides the results of analytical and FEM simulation and measurement tests of the new five-phase dual-feed induction generator.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. 42 no. 4
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 18 May 2023

Hao Chen, Fan Yang, Miguel Pablo Aguirre, Muhammad Asghar Saqib, Galina Demidova, Alecksey Anuchin, Mohamed Orabi, Ryszard Palka, Liudmila Ivanovna Sakhno and Nikolay Vladimirovich Korovkin

Because of the shortage of energy, the development of green and reliable energy is particularly important. As a green and clean energy, wind power is widely used. As the core…

Abstract

Purpose

Because of the shortage of energy, the development of green and reliable energy is particularly important. As a green and clean energy, wind power is widely used. As the core component of wind power generation, it is particularly important to choose generators with high reliability. Switched reluctance machine is widely used as generators because of its strong fault tolerance and high reliability. Therefore, this paper aims to propose a power converter and its control strategy to improve the efficiency of switched reluctance generators.

Design/methodology/approach

In this paper, a full-bridge power converter (FBPC) instead of the asymmetric half-bridge power converter (AHBPC) is adopted to drive the switched reluctance generator (SRG) system. Compare the FBPC with the AHBPC, the FBPC has several advantages including low cost and modularization, and operation process of SRG winding current direction is variable.

Findings

The results show that the SRG system can keep smooth operation by the FBPC with relatively high efficiency.

Originality/value

The FBPC is suitable to drive the SRG system. Meanwhile, this paper introduces two excitation modes of the FBPC as three-phase three-beat mode and six-phase six-beat mode. When the six-phase six-beat control strategy is adopted, the dead band time of the converter can be avoided. At the same time, the SRG has higher efficiency.

Details

Microelectronics International, vol. 40 no. 3
Type: Research Article
ISSN: 1356-5362

Keywords

Article
Publication date: 23 October 2023

Bin Chen, Hongxia Cao and Nina Wan

The purpose of this paper is to study the insulation structure optimization method of multiwinding high-frequency transformer (HFT).

Abstract

Purpose

The purpose of this paper is to study the insulation structure optimization method of multiwinding high-frequency transformer (HFT).

Design/methodology/approach

This paper takes 100 kW, 10 kHz multiwinding HFT as the research object. First, the distribution of electric field strength within the core window of multiwinding HFT with different winding configurations is simulated by the electrostatic field finite element method. The symmetrical hybrid winding structure with minimum electric field strength is selected as the insulation design. To reduce the electric field strength at the end region of the winding, the electrostatic ring and angle ring are designed based on the response surface method.

Findings

The optimal results show that the maximum electric field strength can be reduced by 15.4%, and the low voltage stress can be achieved.

Originality/value

The above research provides guidance and basis for the optimal design of insulation structure of multiwinding HFT.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. 42 no. 6
Type: Research Article
ISSN: 0332-1649

Keywords

Open Access
Article
Publication date: 23 February 2024

Yuliang Du

Auxiliary power system is an indispensable part of the train; the auxiliary systems of both electric locomotives and EMUs mainly are powered by one of the two ways, which are…

121

Abstract

Purpose

Auxiliary power system is an indispensable part of the train; the auxiliary systems of both electric locomotives and EMUs mainly are powered by one of the two ways, which are either from auxiliary windings of traction transformers or from DC-link voltage of traction converters. Powered by DC-link voltage of traction converters, the auxiliary systems were maintained of uninterruptable power supply with energy from electric braking. Meanwhile, powered by traction transformers, the auxiliary systems were always out of power while passing the neutral section of power supply grid and control system is powered by battery at this time.

Design/methodology/approach

Uninterrupted power supply of auxiliary power system powered by auxiliary winding of traction transformer was studied. Failure reasons why previous solutions cannot be realized are analyzed. An uninterruptable power supply scheme for the auxiliary systems powered by auxiliary windings of traction transformers is proposed in this paper. The validity of the proposed scheme is verified by simulation and experimental results and on-site operation of an upgraded HXD3C type locomotive. This scheme is attractive for upgrading practical locomotives with the auxiliary systems powered by auxiliary windings of traction transformers.

Findings

This scheme regenerates braking power supplied to auxiliary windings of traction transformers while a locomotive runs in the neutral section of the power supply grid. Control objectives of uninterrupted power supply technology are proposed, which are no overvoltage, no overcurrent and uninterrupted power supply.

Originality/value

The control strategies of the scheme ensure both overvoltage free and inrush current free when a locomotive enters or leaves the neutral section. Furthermore, this scheme is cost low by employing updated control strategy of software and add both the two current sensors and two connection wires of hardware.

Details

Railway Sciences, vol. 3 no. 2
Type: Research Article
ISSN: 2755-0907

Keywords

Article
Publication date: 8 April 2024

Issaka Ndekugri, Ana Karina Silverio and Jim Mason

States have intervened with legislation to improve cashflow within construction project supply chains. The operation of the UK’s Housing Grants, Construction and Regeneration Act…

Abstract

Purpose

States have intervened with legislation to improve cashflow within construction project supply chains. The operation of the UK’s Housing Grants, Construction and Regeneration Act 1996 leads to payment obligations stated either as a contract administrator’s certificate (or equivalent) or an adjudicator’s decision. The purpose of the intervention would be defeated unless there are speedy ways of transforming these pieces of paper into real money. The combination of the legislation, contractual provisions and insolvency law has produced a minefield of complexity concerning enforcement of payment obligations stated in these documents. Unfortunately, the knowledge and understanding required to navigate these complexities have been sorely lacking. The purpose of this paper is to plug this gap.

Design/methodology/approach

Legal research methods and case study approaches, using relevant court decisions as data, were adopted.

Findings

The enforcement method advised by the court is the summary judgment procedure provided under the Civil Procedure Rules. An overdue payment obligation, either under the terms of a construction contract or an adjudicator’s decision, amounts to a debt that can be the subject of insolvency proceedings. Although the insolvency enforcement method has been successfully used on some occasions, using it purely as a debt collection weapon would be inappropriate and likely to be punished by the court.

Originality/value

The paper contributes to knowledge in two ways: (i) it maps out the factual situations in which these payment challenges arise in language accessible to the construction industry’s professions; and (ii) comparative analysis of payment enforcement methods to aid decision-making by parties to construction industry contracts. It is relevant to the other common-law jurisdictions in which similar statutory interventions have been made.

Details

Journal of Financial Management of Property and Construction , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1366-4387

Keywords

1 – 10 of over 2000