Search results
1 – 10 of 172Shichao Jiang, Xinliang Lu, Hongliang Wang, Kai Song and Yuanyuan Jiang
Detection of hidden defects of aluminum alloy plate with damping coating is a challenging problem. At present, only a few non-destructive testing methods exist to address this…
Abstract
Purpose
Detection of hidden defects of aluminum alloy plate with damping coating is a challenging problem. At present, only a few non-destructive testing methods exist to address this engineering problem. Without the restriction of skin effect, remote field eddy current (RFEC) overcomes the interference caused by the damping coating. The RFEC, which has potential advantages for detecting the hidden defects of aluminum plate with damping coating, can penetrate the metal plate to detect buried depth defects. This study aims to test how thick the RFEC sensor can penetrate the metal plate to detect the buried defects.
Design/methodology/approach
The magnetic field distribution characteristics are analyzed, the magnetic field intensity distribution is calculated, and the structure and parameters of the coil, magnetic circuit and shielding damping are determined through the two- and three-dimensional finite element simulation methods. Optimal excitation frequency is obtained, and the distance between the excitation coil and detection coil is determined by analyzing the relationship between excitation frequency and remote field points.
Findings
Simulation and experimental results verify the feasibility of applying the RFEC detection technology in detecting the hidden defects of aluminum alloy plate with damping coating.
Originality/value
In this paper, the RFEC testing model of hidden defects in aluminum plate sample with damping coating is established by using the finite element method.
Details
Keywords
Abstract
Details
Keywords
Abstract
Details
Keywords
Dennis Albert, Lukas Daniel Domenig, Philipp Schachinger, Klaus Roppert and Herwig Renner
The purpose of this paper is to investigate the applicability of a direct current (DC) hysteresis measurement on power transformer terminals for the subsequent hysteresis model…
Abstract
Purpose
The purpose of this paper is to investigate the applicability of a direct current (DC) hysteresis measurement on power transformer terminals for the subsequent hysteresis model parametrization in transformer grey box topology models.
Design/methodology/approach
Two transformer topology models with two different hysteresis models are used together with a DC hysteresis measurement via the power transformer terminals to parameterize the hysteresis models by means of an optimization. The calculated current waveform with the derived model in the transformer no-load condition is compared to the measured no-load current waveforms to validate the model.
Findings
The proposed DC hysteresis measurement via the power transformer terminals is suitable to parametrize two hysteresis models implemented in transformer topology models to calculate the no-load current waveforms.
Originality/value
Different approaches for the measurement and utilization of transformer terminal measurements for the hysteresis model parametrization are discussed in literature. The transformer topology models, derived with the presented approach, are able to reproduce the transformer no-load current waveform with acceptable accuracy.
Details
Keywords
Klaus Roppert, Florian Toth and Manfred Kaltenbacher
The purpose of this paper is to examine a solution strategy for coupled nonlinear magnetic-thermal problems and apply it to the heating process of a thin moving steel sheet…
Abstract
Purpose
The purpose of this paper is to examine a solution strategy for coupled nonlinear magnetic-thermal problems and apply it to the heating process of a thin moving steel sheet. Performing efficient numerical simulations of induction heating processes becomes ever more important because of faster production development cycles, where the quasi steady-state solution of the problem plays a pivotal role.
Design/methodology/approach
To avoid time-consuming transient simulations, the eddy current problem is transformed into frequency domain and a harmonic balancing scheme is used to take into account the nonlinear BH-curve. The thermal problem is solved in steady-state domain, which is carried out by including a convective term to model the stationary heat transport due to the sheet velocity.
Findings
The presented solution strategy is compared to a classical nonlinear transient reference solution of the eddy current problem and shows good convergence, even for a small number of considered harmonics.
Originality/value
Numerical simulations of induction heating processes are necessary to fully understand certain phenomena, e.g. local overheating of areas in thin structures. With the presented approach it is possible to perform large 3D simulations without excessive computational resources by exploiting certain properties of the multiharmonic solution of the eddy current problem. Together with the use of nonconforming interfaces, the overall computational complexity of the problem can be decreased significantly.
Details
Keywords
Abstract
Details
Keywords
Yuyang Zhang, Yonggang Leng, Hao Zhang, Xukun Su, Shuailing Sun, Xiaoyu Chen and Junjie Xu
An appropriate equivalent model is the key to the effective analysis of the system and structure in which permanent magnet takes part. At present, there are several equivalent…
Abstract
Purpose
An appropriate equivalent model is the key to the effective analysis of the system and structure in which permanent magnet takes part. At present, there are several equivalent models for calculating the interacting magnetic force between permanent magnets including magnetizing current, magnetic charge and magnetic dipole–dipole model. How to choose the most appropriate and efficient model still needs further discussion.
Design/methodology/approach
This paper chooses cuboid, cylindrical and spherical permanent magnets as calculating objects to investigate the detailed calculation procedures based on three equivalent models, magnetizing current, magnetic charge and magnetic dipole–dipole model. By comparing the accuracies of those models with experiment measurement, the applicability of three equivalent models for describing permanent magnets with different shapes is analyzed.
Findings
Similar calculation accuracies of the equivalent magnetizing current model and magnetic charge model are verified by comparison between simulation and experiment results. However, the magnetic dipole–dipole model can only accurately calculate for spherical magnet instead of other nonellipsoid magnets, because dipole model cannot describe the specific characteristics of magnet's shape, only sphere can be treated as the topological form of a dipole, namely a filled dot.
Originality/value
This work provides reference basis for choosing a proper model to calculate magnetic force in the design of electromechanical structures with permanent magnets. The applicability of different equivalent models describing permanent magnets with different shapes is discussed and the equivalence between the models is also analyzed.
Details
Keywords
Habeeba Khan, Sayyed Arif Ali, Mohd Wajid and Muhammad Shah Alam
In this work, a microstrip antenna array for wireless power transfer (WPT) application is reported. The proposed 4 × 4 antenna array operating at 16 GHz is designed using a…
Abstract
Purpose
In this work, a microstrip antenna array for wireless power transfer (WPT) application is reported. The proposed 4 × 4 antenna array operating at 16 GHz is designed using a flexible Kapton polyimide substrate for a far-field charging unit (FFCU).
Design/methodology/approach
The proposed antenna is designed using the transmission line model on a flexible Kapton polyimide substrate. The finite element method (FEM) is used to perform the full-wave electromagnetic analysis of the proposed design.
Findings
The antenna offers −10 dB bandwidth of 240 MHz with beam width and broadside gain found to be 29.4° and 16.38 dB, respectively. Also, a very low cross-polarization level of −34.23 dB is achieved with a radiation efficiency of 36.67%. The array is capable of scanning −15° to +15° in both the elevation and azimuth planes.
Originality/value
The radiation characteristics achieved suggest that the flexible substrate antenna is suitable for wireless charging purposes.
Details
Keywords
Abstract
Details