Abstract
Purpose
The purpose of this paper is the proposal of fatigue-life-prediction curve for cast aluminum alloy A356-T6 with different casting defect sizes.
Design/methodology/approach
Four kinds of A356-T6 fatigue specimens were sampled from the actual large-scale cast component, where the cooling rates were different. In addition, three kinds of A356 were casted under different casting conditions to simulate different defect sizes in the actual component. Subsequently, rotating bending fatigue tests were conducted using those samples. The maximum sizes of casting defects were quantitatively evaluated through microstructural observation and extreme value statistics. The fatigue limits of all samples were predicted using hardness and defect sizes based on modified Murakami’s equation.
Findings
The modified equation for fatigue limit prediction in A356-T6 was proposed. Fatigue limits were successfully predicted using the proposed equation.
Originality/value
Fatigue limit prediction method using hardness and maximum defect size was limited to steels. This paper proposed the modified method for A356-T6 aluminum alloy with lower elastic modulus. The method was valid for A356-T6 with different defect sizes.
Keywords
Citation
Uematsu, Y., Kakiuchi, T., Tajiri, A. and Nakajima, M. (2017), "Fatigue limit prediction of A356-T6 cast aluminum alloys with different defect sizes sampled from an actual large-scale component", International Journal of Structural Integrity, Vol. 8 No. 6, pp. 617-631. https://doi.org/10.1108/IJSI-12-2016-0038
Publisher
:Emerald Publishing Limited
Copyright © 2017, Emerald Publishing Limited