To read this content please select one of the options below:

Development of the 3D dome model based on a terrestrial laser scanner

Abdul Fatah Firdaus Abu Hanipah (Centre of Studies for Surveying Science and Geomatics, Universiti Teknologi MARA, Shah Alam, Malaysia)
Khairul Nizam Tahar (Centre of Studies for Surveying Science and Geomatics, Universiti Teknologi MARA, Shah Alam, Malaysia)

International Journal of Building Pathology and Adaptation

ISSN: 2398-4708

Article publication date: 12 April 2018

Issue publication date: 4 May 2018

240

Abstract

Purpose

Laser scanning technique is used to measure and model objects using point cloud data generated laser pulses. Conventional techniques to construct 3D models are time consuming, costly and need more manpower. The purpose of this paper is to assess the 3D model of the Sultan Salahuddin Abdul Aziz Shah Mosque’s main dome using a terrestrial laser scanner.

Design/methodology/approach

A laser scanner works through line of sight, which indicates that multiple scans need to be taken from a different view to ensure a complete data set. Targets must spread in all directions, and targets should be placed on fixed structures and flat surfaces for the normal scan and fine scan. After the scanning operation, point cloud data from the laser scanner were cleaned and registered before a 3D model could be developed.

Findings

As a result, the reconstruction of the 3D model was successfully developed. The samples are based on the triangle dimension, curve line, horizontal dimension and vertical dimension at the dome. The standard deviation and accuracy are calculated based on the comparison of the 21 samples taken between the high-resolution and low-resolution scanning data.

Originality/value

There are many ways to develop the 3D model and based on this study, the less complex ways also produce the best result. The authors implement the different types of dimensions for the 3D model assessment, which have not yet been considered in the past.

Keywords

Acknowledgements

Faculty of Architecture, Planning, and Surveying Universiti Teknologi MARA (UiTM), Research Management Institute (RMi) and Ministry of Higher Education (MOHE) are greatly acknowledged for providing the fund BESTARI 600-IRMI/MyRA 5/3/BESTARI (001/2017) to enable this research to be carried out. The authors would also like to thank the people who were directly or indirectly involved in this research.

Citation

Abu Hanipah, A.F.F. and Tahar, K.N. (2018), "Development of the 3D dome model based on a terrestrial laser scanner", International Journal of Building Pathology and Adaptation, Vol. 36 No. 2, pp. 122-136. https://doi.org/10.1108/IJBPA-05-2017-0024

Publisher

:

Emerald Publishing Limited

Copyright © 2018, Emerald Publishing Limited

Related articles