To read this content please select one of the options below:

Effect of impeller installation position on unsteady flow characteristics of a vortex pump

Kaiyao Zhao (National Research Center of Pumps, Jiangsu University, Zhenjiang, China)
Minggao Tan (National Research Center of Pumps, Jiangsu University, Zhenjiang, China)
Xianfang Wu (School of Energy and Power Engineering, Jiangsu University, Zhenjiang, China)
Chen Shao (National Research Center of Pumps, Jiangsu University, Zhenjiang, China)
Houlin Liu (National Research Center of Pumps, Jiangsu University, Zhenjiang, China)

Engineering Computations

ISSN: 0264-4401

Article publication date: 20 February 2023

Issue publication date: 19 April 2023

111

Abstract

Purpose

The purpose of the paper is to disclose the effect of the relative position (d) between the impeller and non-vane cavity on the hydraulic performance and unsteady characteristics of vortex pump.

Design/methodology/approach

Three groups of vortex pump models with different impeller installation positions were analyzed and studied by combining experimental and CFD (Computational Fluid Dynamics) numerical calculations.

Findings

The steady numerical results show that as the width (d) of the impeller moves into the non-vane cavity increases, the proportion of circulation flow in the non-vane cavity is reduced and both the pump head and efficiency are on the rise. The unsteady numerical results and the Enstrophy analysis show that the dynamic and static interference between the circulation flow and the volute tongue is the main reason for the pressure pulsation with a frequency of 2fn in the vortex pump. With the increase of the d value, the dynamic and static interference between the circulation flow and the volute tongue is enhanced. The pulsation amplitude at the volute tongue of the d = 16.5 mm model increases about six times compared with the d = 0 mm model; the distribution of the vortex core in the non-vane cavity is closely related to the position of the impeller, and the peak of the Enstrophy of the circulation flow vortex belt always appears at the top of the impeller.

Originality/value

The research results provide a theoretical foundation for the optimization and improvement of the vortex pump.