Search results

1 – 1 of 1
Open Access
Book part
Publication date: 4 May 2018

Salahuddin, Bakhtiar, Yusman and Fadhli

Purpose – This study aims to design and build a wireless supervisory control and data acquisition (SCADA) system based on Protocol AX.25 with the aim of monitoring the performance…

Abstract

Purpose – This study aims to design and build a wireless supervisory control and data acquisition (SCADA) system based on Protocol AX.25 with the aim of monitoring the performance of several parameters in Microhydro Power Plant (MHPP). This system can monitor several MHPP parameters such as voltage, current, frequency, and turbine rotation so that it can be accessed directly at one central location.

Design/Methodology/Approach – The design is done by taking into account the real parameters that exist in the MHPP. Some parameters that become the main object to see the performance of MHPP are voltage, current, frequency, and turbine rotation. The voltage generated by the MHPP must be adjusted to the voltage supplied by State Electricity Company to the consumer, including the phase used. The resulting stream should also be monitored for power to be adjusted to the turbine spin. The generator frequency is kept stable according to the standard frequency of the State Electricity Company generator.

Findings – The remote terminal unit (RTU) system has been simulated using 2 ACS712 current sensors, voltage sensor, zero crossing point, frequency sensor, and rotation sensor functionalized to monitor MHPP parameters. The AX.25 protocol has been applicable in the wireless SCADA network for monitoring the performance of MHPP by embedding in KYL-1020UA transceiver radio using the 433 MHz frequency and the audio frequency shift keying modulation system. Radio transmitter KYL-1020UA has been successfully simulated to send data from sensors to display on the computer through SCADA built applications. The data changes in the RTU section can be displayed properly on the graphic user interface in accordance with the existing display at the MHPP location.

Research Limitations/Implications – There are only two RTUs that will be connected to communicate, in this case MHPP-1 with callsign “RTU-001” and MHPP-2 with callsign “RTU-002.” While the existing devices in the data access section parameters MHPP as master station with callsign “MSSCADA” monitoring the performance of parameters sent from the RTU. There is no collision or error in data transmission. Baudrate is varied at 1,200 bps, 2,400 bps, 4,800 bps, and 9,600 bps for effective throughput calculation and AX.25 protocol efficiency. The transmission distance is varied at 100 m, 200 m, 300 m, and 500 m to see the bit error rate with baudrate 1,200 bps and 9,600 bps.

Practical Implications – This product is expected to be applied to several MHPP locations in Aceh Province so that its monitoring system is more centralized and efficient.

Originality/Value – This research if for the efficient monitoring of several MHPP located far apart and can be monitored in one central location so that operators do not have to be located at the plant site.

Access

Only Open Access

Year

Content type

Book part (1)
1 – 1 of 1