Search results
1 – 10 of 159Farshid Rashidiyan, Seyed Rasoul Mirghaderi, Saeed Mohebbi and Sina Kavei
This research study focuses on investigating the seismic performance of non-straight beams in steel structures and exploring the mechanism by which plastic hinges are formed…
Abstract
Purpose
This research study focuses on investigating the seismic performance of non-straight beams in steel structures and exploring the mechanism by which plastic hinges are formed within these beams. The findings contribute to the understanding of their behaviour under seismic loads and offer insights into their potential for enhancing the lateral resistance of the structure. The abstract of the study highlights the significance of corners in structural plans, where non-coaxial columns, diagonal elements or beams deviating from a straight path are commonly observed. Typically, these non-straight beams are connected to the columns using pinned connections, despite their unknown seismic behaviour. Recognizing the importance of generating plastic hinges in special moment resisting frames and the lack of previous research on the involvement of these non-straight beams, this study aims to address this knowledge gap.
Design/methodology/approach
This study examines the seismic behaviour and plastic hinge formation of non-straight beams in steel structures. Non-straight beams are beams that connect non-coaxial columns and diagonal elements, or deviate from a linear path. They are usually pinned to the columns, and their seismic contribution is unknown. A critical case with a 12-m non-straight beam is analysed using Abaqus software. Different models are created with varying cross-section shapes and connection types between the non-straight beams. The models are subjected to lateral monotonic and cyclic loads in one direction. The results show that non-straight beams increase the lateral stiffness, strength and energy dissipation of the models compared to disconnected beams that act as two cantilevers.
Findings
The analysis results reveal several key findings. The inclusion of non-straight beams in the models leads to increased lateral stiffness, strength and energy dissipation compared to the scenario where the beams are disconnected and act as two cantilever beams. Plastic hinges are formed at both ends of the non-straight beam when a 3% drift is reached, contributing to energy damping and introducing plasticity into the structure. These results strongly suggest that non-straight beams play a significant role in enhancing the lateral resistance of the system. Based on the seismic analysis results, this study recommends the utilization of non-straight beams in special moment frames due to the formation of plastic hinges within these beams and their effective participation in resisting lateral seismic loads. This research fills a critical gap in understanding the behaviour of non-straight beams and provides valuable insights for structural engineers involved in the design and analysis of steel structures.
Originality/value
The authors believe that this research will greatly contribute to the knowledge and understanding of the seismic performance of non-straight beams in steel structures.
Details
Keywords
Mohammadsina Sharifi Ghalehnoei
The purpose of this study is to develop the performance model of buildings designed by the seismic code 2800 against the explosion wave and determination of safety distance.
Abstract
Purpose
The purpose of this study is to develop the performance model of buildings designed by the seismic code 2800 against the explosion wave and determination of safety distance.
Design/methodology/approach
Analytical models of three-, five- and ten story structures that used moment frame system and also a ten-storey building with shaer wall designed based on the seismic code 2800 in term of design and nonlinear analysis were generated for use with Perform-3D software. Extensive parametric analysis is executed on different explosive loads with 100, 500, 1,000 and 5,000 Trinitrotoluene, soil types 2 and 3, models eqs and eqbs, the number of story buildings and the effect of shear wall to determine the safety distance based on collapse threshold performance (CP) level criterion.
Findings
The results indicate that by increasing the explosives mass from 100 to 5,000 kg and the number of the stories three and five induce increasing the safety distance of CP level in buildings to 4.5 meter and 3 meter times, respectively. Ten-story structures modeled on shear wall show very good performance because of stiffness rising and high energy absorption. In addition, by increasing the stories from five to ten, the amount of the safety distance reduces the CP level to 3.9 meter times.
Originality/value
The results of this work are meaningful for explosion-resistant design and damage assessments of reinforced concrete moment framed structures subjected to explosive explosion.
Details
Keywords
Mohammad Farhan Shaikh and Nallasivam K
In this study, a finite element model of a box-girder bridge along with the railway sub-track system is developed to predict the static behavior due to different combinations of…
Abstract
Purpose
In this study, a finite element model of a box-girder bridge along with the railway sub-track system is developed to predict the static behavior due to different combinations of the Indian railway system and free vibration responses resulting in different natural frequencies and their corresponding mode shapes.
Design/methodology/approach
The modeling and evaluation of the bridge and sub-track system were performed using non-closed form finite element method (FEM)-based ANSYS software.
Findings
From the analysis, the worst possible cases of deformation and stress due to different static load combinations were determined in the static analysis, while different natural frequencies were determined in the free vibrational analysis that can be used for further analysis because of the dynamic effect of the train vehicle.
Research limitations/implications
The scope of the current investigation is confined to the structure's static and free vibration analysis. However, this study will help the designers obtain relevant information for further analysis of the dynamic behavior of the bridge model.
Originality/value
In static analysis, the maximum deformation of the bridge deck was found to be 10.70E-03m due to load combination 5, whereas the maximum natural frequency for free vibration analysis is found to be 4.7626 Hz.
Details
Keywords
Maha Assad, Rami Hawileh, Ghada Karaki, Jamal Abdalla and M.Z. Naser
This research paper aims to investigate reinforced concrete (RC) walls' behaviour under fire and identify the thermal and mechanical factors that affect their performance.
Abstract
Purpose
This research paper aims to investigate reinforced concrete (RC) walls' behaviour under fire and identify the thermal and mechanical factors that affect their performance.
Design/methodology/approach
A three-dimensional (3D) finite element (FE) model is developed to predict the response of RC walls under fire and is validated through experimental tests on RC wall specimens subjected to fire conditions. The numerical model incorporates temperature-dependent properties of the constituent materials. Moreover, the validated model was used in a parametric study to inspect the effect of the fire scenario, reinforcement concrete cover, reinforcement ratio and configuration, and wall thickness on the thermal and structural behaviour of the walls subjected to fire.
Findings
The developed 3D FE model successfully predicted the response of experimentally tested RC walls under fire conditions. Results showed that the fire resistance of the walls was highly compromised under hydrocarbon fire. In addition, the minimum wall thickness specified by EC2 may not be sufficient to achieve the desired fire resistance under considered fire scenarios.
Originality/value
There is limited research on the performance of RC walls exposed to fire scenarios. The study contributed to the current state-of-the-art research on the behaviour of RC walls of different concrete types exposed to fire loading, and it also identified the factors affecting the fire resistance of RC walls. This guides the consideration and optimisation of design parameters to improve RC walls performance in the event of a fire.
Details
Keywords
Jingxiao Shu, Yao Lu and Yan Liang
To understand the seismic behavior of reinforced concrete (RC) beams confined by corroded stirrups, low-reversed cyclic loading tests were carried out on seven RC beam specimens…
Abstract
Purpose
To understand the seismic behavior of reinforced concrete (RC) beams confined by corroded stirrups, low-reversed cyclic loading tests were carried out on seven RC beam specimens with different stirrup corrosion levels and stirrup ratios to investigate their mechanical characteristics.
Design/methodology/approach
The failure mode, hysteresis behavior, skeleton curves, ductility, stiffness degradation and energy dissipation behavior of RC specimens are compared and discussed. The experimental results showed that the restraint of concrete provided by corroded stirrups is reduced, which leads to a decline in seismic performance.
Findings
For the specimens with the same ratios of stirrup, as the corrosion level increased, the load-carrying capacity, stiffness, plastic deformation capacity and energy-dissipation capacity dropped significantly. Compared with the uncorroded specimen, the failure modes of specimens with high corrosion level changed from ductile bending failure to brittle failure. For the specimens with the same levels of corrosion, the higher the stirrup ratio was, the stronger the restraint effect of the stirrups on the concrete, and the seismic behavior of the specimens was obviously improved.
Originality/value
In this paper, a total of seven full-size RC beam specimens at joints with different stirrup corrosion levels and stirrup ratios were designed and constructed to explore the influences of corrosion levels and stirrup ratios of stirrups on the seismic performances. The failure modes, strain of reinforcement, hysteretic curves, skeleton curves, stiffness degradation and ductility factor of RC specimens are compared and discussed.
Details
Keywords
Tassadit Hermime, Abdelghani Seghir and Smail Gabi
The purpose of this paper is the dynamic analysis and seismic damage assessment of steel sheet pile quay wall with inelastic behavior underground motions using several…
Abstract
Purpose
The purpose of this paper is the dynamic analysis and seismic damage assessment of steel sheet pile quay wall with inelastic behavior underground motions using several accelerograms.
Design/methodology/approach
Finite element analysis is conducted using the Plaxis 2D software to generate the numerical model of quay wall. The extension of berth 25 at the port of Bejaia, located in northeastern Algeria, represents a case study. Incremental dynamic analyses are carried out to examine variation of the main response parameters under seismic excitations with increasing Peak ground acceleration (PGA) levels. Two global damage indices based on the safety factor and bending moment are introduced to assess the relationship between PGA and the damage levels.
Findings
The results obtained indicate that the sheet pile quay wall can safely withstand seismic loads up to PGAs of 0.35 g and that above 0.45 g, care should be taken with the risk of reaching the ultimate moment capacity of the steel sheet pile. However, for PGAs greater than 0.5 g, it was clearly demonstrated that the excessive deformations with material are likely to occur in the soil layers and in the structural elements.
Originality/value
The main contribution of the present work is a new double seismic damage index for a steel sheet pile supported quay wharf. The numerical modeling is first validated in the static case. Then, the results obtained by performing several incremental dynamic analyses are exploited to evaluate the degradation of the soil safety factor and the seismic capacity of the pile sheet wall. Computed values of the proposed damage indices of the considered quay wharf are a practical helping tool for decision-making regarding the seismic safety of the structure.
Details
Keywords
Fatimah De’nan, Chong Shek Wai, Tong Teong Yen, Zafira Nur Ezzati Mustafa and Nor Salwani Hashim
Brief introduction on the importance and the need for plastic analysis methods were presented in the beginning section of this review. The plastic method for analysis was…
Abstract
Purpose
Brief introduction on the importance and the need for plastic analysis methods were presented in the beginning section of this review. The plastic method for analysis was considered to be the more advanced method of analysis because of its ability to represent the true behaviour of the steel structures. Then in the following section, a literature analysis has been carried out on the previous investigations done on steel plates, steel beams and steel frames by other authors. The behaviour of them under different types of loading were presented and are under the investigation of innovative new analysis methods.
Design/methodology/approach
Structure member connections also have the potential for plastic failure. In this study, the authors have highlighted a few topics to be discussed. The three topics in this study are T-end plate connections to a square hollow section, semi-rigid connections and cold-formed steel storage racks with spine bracings using speed-lock connections. Connection is one of the important parts of a structure that ensures the integrity of the structure. Finally, in this technical paper, the authors introduce some topics related to seismic action. Application of the Theory of Plastic Mechanism Control in seismic design is studied in the beginning. At the end, its in-depth application for moment resisting frames-eccentrically braced frames dual systems is investigated.
Findings
When this study involves the design of a plastic structure, the design criteria must involve the ultimate load rather than the yield stress. As the steel behaves in the plastic range, it means the capacity of the steel has reached the ultimate load. Ultimate load design and load factor design are the methods in the range of plastic analysis. After the steel capacity has reached beyond the yield stress, it fulfills the requirement in this method. The plastic analysis method offers a consistent and logical approach to structural analysis. It provides an economical solution in terms of steel weight, as the sections designed using this method are smaller compared with elastic design methods.
Originality/value
The plastic method is the primary approach used in the analysis and design of statically indeterminate frame structures.
Details
Keywords
Chaofan Wang, Yanmin Jia and Xue Zhao
Prefabricated columns connected by grouted sleeves are increasingly used in practical projects. However, seismic fragility analyses of such structures are rarely conducted…
Abstract
Purpose
Prefabricated columns connected by grouted sleeves are increasingly used in practical projects. However, seismic fragility analyses of such structures are rarely conducted. Seismic fragility analysis has an important role in seismic hazard evaluation. In this paper, the seismic fragility of sleeve connected prefabricated column is analyzed.
Design/methodology/approach
A model for predicting the seismic demand on sleeve connected prefabricated columns has been created by incorporating engineering demand parameters (EDP) and probabilities of seismic failure. The incremental dynamics analysis (IDA) curve clusters of this type of column were obtained using finite element analysis. The seismic fragility curve is obtained by regression of Exponential and Logical Function Model.
Findings
The IDA curve cluster gradually increased the dispersion after a peak ground acceleration (PGA) of 0.3 g was reached. For both columns, the relative displacement of the top of the column significantly changed after reaching 50 mm. The seismic fragility of the prefabricated column with the sleeve placed in the cap (SPCA) was inadequate.
Originality/value
The sleeve was placed in the column to overcome the seismic fragility of prefabricated columns effectively. In practical engineering, it is advisable to utilize these columns in regions susceptible to earthquakes and characterized by high seismic intensity levels in order to mitigate the risk of structural damage resulting from ground motion.
Details
Keywords
Massimo Coli, Marco Tanganelli, Michele Baldi and Stefania Viti
The paper is aimed at assessing the safety of the Giotto's Bell Tower, with special attention to its foundation system, i.e. the foundation works and soil. The tower, well known…
Abstract
Purpose
The paper is aimed at assessing the safety of the Giotto's Bell Tower, with special attention to its foundation system, i.e. the foundation works and soil. The tower, well known all over the world, has a squared plan, with sides of 14.45 m each, and a total height equal to 84.7 m. The structural response of the tower is assessed with reference to the gravitational load and to the expected seismic action, quantified according to the seismic hazard of the site and the foundation soil.
Design/methodology/approach
A simplified analysis has been performed to check the safety level of the tower to seismic actions. Special attention has been paid to quantify the horizontal actions representing the seismic loads. Such quantification, indeed, has been made both through the elastic spectrum of the tower and by performing a site response analysis on the foundation soil, represented as a one-dimensional stratification of soil layers, described on the basis of experimental investigations. After defining the loading actions, a simplified assessment of the foundation safety has been made by considering the action over foundation, the geotechnical data and the safety factor.
Findings
The findings of the paper concern the assessment of the safety of the tower's foundation system. A lot of experimental data on the foundation soil, provided by various geological investigations, have been provided and used for the assessment. Moreover, the mechanical properties of the materials used for the structure have been collected and shown in the paper.
Originality/value
The paper collects a lot of technical information regarding the Giotto's Bell Tower, both regarding its foundation soil and the constituting materials. On the basis of the collected information, a structural analysis has been made to assess the seismic safety of the tower, and the results of such assessment are provided and discussed.
Details
Keywords
Mohammed Jazeel, Sam Paul P., Lawrance Gunaraj and Hemalatha G.
Nowadays, in building structures, dampers are connected to the building structure to reduce the damages caused by seismicity in addition to enhancing structural stability, and to…
Abstract
Purpose
Nowadays, in building structures, dampers are connected to the building structure to reduce the damages caused by seismicity in addition to enhancing structural stability, and to connect dampers with the structure, joints are used. In this paper, three different configurations of double-lap joints were designed, developed and tested.
Design/methodology/approach
This paper aims to analyze three different categories of double-lap single-bolted joints that are used in connecting dampers with concrete and steel frame structures. These joints were designed and tested using computational, numerical and experimental methods. The studies were conducted to examine the reactions of the joints during loading conditions and to select the best joints for the structures that allow easy maintenance of the dampers and also withstand structural deformation when the damper is active during seismicity. Also, a computational analysis was performed on the designed joints integrated with the M25 concrete beam column junction. In this investigation, experimental study was carried out in addition to numerical and computational methods during cyclic load.
Findings
It was observed from the result that during deformation the double-base multiplate lap joint was suitable for buildings because the deformations on the joint base was negligible when compared with other joints. From the computational analysis, it was revealed that the three double joints while integrated with the beam column junction of M25 grade concrete structure, the damages induced by the double-base multiplate joint was negligible when compared with other two joints used in this study.
Originality/value
To prevent the collapse of the building during seismicity, dampers are used and further connecting the damper with the building structures, joints are used. In this paper, three double-lap joints in different design configuration were studied using computational, numerical and experimental techniques.
Details