Search results

1 – 1 of 1
Article
Publication date: 28 April 2023

Deepak Doreswamy, Abhijay B.R., Jeane Marina D’Souza, Sachidananda H.K. and Subraya Krishna Bhat

Soft actuators using pneumatic-chamber (PneuNet)-based designs have been of interest in the area of soft robotics with scope of application in the area of biomedical assistance…

Abstract

Purpose

Soft actuators using pneumatic-chamber (PneuNet)-based designs have been of interest in the area of soft robotics with scope of application in the area of biomedical assistance and smart agriculture. Researchers have attempted to investigate multiple chambers in parallel to examine their deformation characteristics. However, there is a lacuna for investigation of the deformation characteristics of four parallel chambered soft actuators. The purpose of this study is to comprehensively investigate the different possible actuation scenarios and the resulting bending/deformation behaviours.

Design/methodology/approach

Therefore, in this study, a four-chambered PneuNet actuator is numerically investigated to evaluate the effects of pressurization scenarios and pressure levels on its performance, operating reaching and working volume.

Findings

The results of this study revealed that two-adjacent chamber equal pressurization and three-chamber pressurizations result in increased bending. However, two-opposite chamber pressurization reduces the bending angle with pressure levels in the lower pressure chamber. The maximum bending angle of 97° was achieved for single-chamber pressurization of 300 kPa. The two-adjacent chamber unequal pressurization can achieve a sweeping motion in the actuator along with bending. The working volume and reaching capability analysis revealed that the actuator can reach around 71% of the dimensional operating space.

Practical implications

The results provide fundamental guidance on the output nature of motion which can be obtained under different pressurization scenarios using the four-chambered design soft actuator, thereby making it a practical guide for implementation for useful applications.

Originality/value

The comprehensive pressurization scenarios and pressure level variations reported in this study will serve as fundamental operating guidelines for any practical implementation of the four-chambered PneuNet actuator.

Details

World Journal of Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1708-5284

Keywords

1 – 1 of 1