Search results

1 – 2 of 2
Article
Publication date: 4 September 2019

Hakan Göçerler, Bernhard Pfeil, Friedrich Franek, Christoph Bauer, Eugenia Niculescu-Morzsa and Stefan Nehrer

The paper aims to focus on the individual contribution of water to the lubrication regimes in articular joints because understanding of these regimes is crucial not only for the…

Abstract

Purpose

The paper aims to focus on the individual contribution of water to the lubrication regimes in articular joints because understanding of these regimes is crucial not only for the treatment of diseases like osteoarthritis but also for the development of new implants to have a longer service cycle.

Design/methodology/approach

Cartilage specimen and the synovial fluid were both isolated from bovine knee joints that are enclosed by a synovial membrane under sterile conditions of a biosafety Level 2 (BSL2) cabinet. Subchondral bone was removed from the cartilage because it not only creates a stable base to place the specimen on the holder, but it also acts as a primary shock absorber protecting the overlaying cartilage under high-impact loads. A specimen holder specially designed for tests and was attached to the linear oscillation (SRV) test machine. The SRV test machine provides a reciprocating sliding motion between the cartilage samples that are submerged into the selected biological media. The entire system can be mounted on the BSL2 cabinet, sealed with the convoluted gaiter and transported to the SRV machine with a specifically designed handle for the entire system. The process ensures sterile conditions for tests on biological samples that are highly sensitive to the environmental conditions.

Findings

A remarkably low coefficient of friction value for distilled water constitutes more evidence to support the assumption of the impact of water in the friction behaviour of the cartilage-against-cartilage contact. As the fluid in articular cartilage (AC) effectively serves as a synovial fluid reserve and 70-80 per cent of its composition is distilled water, it can be stated that the tribotest system mimics the natural working conditions of an actual knee joint adequately.

Research limitations/implications

Time and limited availability of the animal-driven samples led to a focus on certain parameters mentioned in the approach. A planned scan of parameter matrix, such as variation of load and speed, would allow deeper knowledge on the lubrication regimes.

Practical implications

Study of relevant tribological contact in human joints might give ideas on new designs for artificial joints.

Social implications

Understanding of lubrication regimes is crucial not only for the treatment of diseases like osteoarthritis but also for the development of new implants to adapt motion of related joint.

Originality/value

Exclusion of water and application as the primary lubricant in the test system brings a new perspective to joint lubrication.

Details

Industrial Lubrication and Tribology, vol. 72 no. 1
Type: Research Article
ISSN: 0036-8792

Keywords

Open Access
Article
Publication date: 23 November 2021

Hakan Göcerler, Simon Medina, Michael Adler, Josef Brenner, Andreas Tadler, Michael Nagl and Christine Hohenadl

Dry eye syndrome is one of the most common reasons for eye-related discomfort which, without treatment, in some cases may even lead to corneal damage. Blinking, baseline and…

Abstract

Purpose

Dry eye syndrome is one of the most common reasons for eye-related discomfort which, without treatment, in some cases may even lead to corneal damage. Blinking, baseline and reflex lachrymation and drainage compromise the topical application of therapeutics demanding repeated, often hourly applications of common lubricants. In contrast, topically administered chitosan-N-acetylcysteine-based eye drops were reported to sustain on the ocular surface for more than 24 h. The thiolated biopolymer can interact with the corneal mucin layer thereby forming covalent disulphide bridges, which may contribute to extended residence times.

Design/methodology/approach

In this study, the tribological characteristics of four different lubricants including hyaluronic acid and chitosan-N-acetylcysteine containing commercially available eye drops were investigated. For this purpose, a representative test setup was developed, which mimics the contact between the cornea and the eyelid wiper. Gels with different elastic properties coated with a mucin layer were used as a substrate to mimic the corneal surface. Tests were conducted with a micro-tribometer, and friction values were recorded. Contact zones were characterized by X-ray photoelectron spectroscopy to investigate wear and thiol bonding on the surface.

Findings

Results revealed the lowest average coefficient of friction values for chitosan-N-acetylcysteine-based eye drops and substrate dependence of the test setup.

Originality/value

In this study, the authors introduced an in vitro system to test different types of eye drops so that chemical interaction with the mucin layer can be observed. These interactions change the tribological performance significantly and must be considered to have results relevant to the actual application.

Details

Industrial Lubrication and Tribology, vol. 73 no. 10
Type: Research Article
ISSN: 0036-8792

Keywords

1 – 2 of 2