Search results
1 – 2 of 2The purpose of this paper is to evaluate various reliability metrics such as transition state probabilities, availability, reliability, mean time to failure and expected profit of…
Abstract
Purpose
The purpose of this paper is to evaluate various reliability metrics such as transition state probabilities, availability, reliability, mean time to failure and expected profit of two non-identical unit parallel system incorporating waiting time.
Design/methodology/approach
The present paper investigates the reliability of two non-identical unit parallel system with two types of failures: common cause failure and partial failure. Moreover, waiting time to repair, a significant aspect of reliability analysis, has also been incorporated. The considered system is assumed to function properly if at least one of the units is in operative mode. The present system is examined by using the supplementary variable technique and Laplace transformation.
Findings
Numerical calculation shows that the availability and the reliability of the system is minimum when the system is without partial failure and is maximum when the system is free from common cause failure. Finally, the cost analysis of the system reveals that the expected profit decreases with increase in service cost.
Originality/value
This paper presents a mathematical model of two dissimilar unit parallel system, through which the performance of the considered system can be improved.
Details
Keywords
Garima Nema and Karunamurthy K.
This study aims to provide an alternative adoption to overcome the energy crisis and environmental effluence by comparative theoretical and trial testing analysis of an innovative…
Abstract
Purpose
This study aims to provide an alternative adoption to overcome the energy crisis and environmental effluence by comparative theoretical and trial testing analysis of an innovative combined condenser unit over traditional individual condenser unit water heating systems.
Design/methodology/approach
The presented innovative new unit of the combined condenser heat pipe works efficiently through its improved idea and unique design, providing uniform heating to improve the heat transfer and, finally, the temperature of water increases without enhancing the cost. In this design, all these five evaporator units were connected with a single combined condenser unit in such a manner that after the condensation of heat transfer fluid vapour, it goes equally into the evaporator pipe.
Findings
The maximum temperature of hot water obtained from the combined condenser heating system was 60.6, 55.5 and 50.3°C at a water flow rate of 0.001, 0.002 and 0.003 kg/s, respectively. The first and second law thermodynamic efficiency of the combined condenser heating system were 55.4%, 60.5% and 89.0% and 2.6%, 3.7% and 4.1% at 0.001, 0.002 and 0.003 kg/s of water flow rates, respectively. The combined condenser heat pipe solar evacuated tube heating system promoting progressive performance is considered efficient and environment-friendly compared to the traditional condenser unit water heating system.
Originality/value
Innovative combined condenser heat pipe evacuated tube collector assembly was designed and developed for the study. A comparative theoretical and experimental energy-exergy performance analysis was performed of innovated collective condenser and traditional individual condenser heat pipe water heating system at various mass flow rate.