Search results
1 – 3 of 3The purpose of this experimental research was to examine a novel axial heat exchanger featuring swirling air movement over heated tubes. This apparatus is designed with perforated…
Abstract
Purpose
The purpose of this experimental research was to examine a novel axial heat exchanger featuring swirling air movement over heated tubes. This apparatus is designed with perforated circular baffle plates complemented by rectangular air deflectors operating at different inclination angles. The tubes were arranged in a consistent layout parallel to the longitudinal airflow. The deflector’s heightened air-side turbulence initiates the frenzied motion, escalating the surface heat transfer rate.
Design/methodology/approach
The tubes maintained a constant heat flux condition over the surface. In each baffle plate, eight deflectors with identical inclination angles were devised in a reverse position, forming a rotation of air inside a circular duct that held tubes (carrying hot water) which elevated air-side turbulence, thereby enhancing the rate of heat transference on the surface. The baffle plates were equally situated from each other at changing pitch ratios. The Reynolds quantity was preserved in the scope of 16,000–30,000. The performance of the heat exchanger considering pitch ratios and inclination angles was examined.
Findings
The research indicates that when examined under similar conditions, an exchanger with a deflector baffle plate shows a strong dependence on the pitch ratio and inclination angle with a mean rise of 0.19 times in thermal enhancement factor at an inclination angle of 30° and a pitch ratio of 1.2 contrasted with an exchanger with segmental baffle plates.
Originality/value
The result shows the dependence of pitch ratio, Reynolds number and inclination on the heat transfer and friction factor rate.
Details
Keywords
Fayaz Kharadi, Karthikeyan A, Virendra Bhojwani, Prachi Dixit, Nand Jee Kanu and Nidhi Jain
The purpose of this study is to achieve lower and lower temperature as infrared sensors works faster and better used for space application. For getting good quality images from…
Abstract
Purpose
The purpose of this study is to achieve lower and lower temperature as infrared sensors works faster and better used for space application. For getting good quality images from space, the infrared sensors are need to keep in cryogenic temperature. Cooling to cryogenic temperatures is necessary for space-borne sensors used for space applications. Infrared sensors work faster or better at lower temperatures. It is the need for time to achieve lower and lower temperatures.
Design/methodology/approach
This study presents the investigation of the critical Stirling cryocooler parameters that influence the cold end temperature. In the paper, the design approach, the dimensions gained through thermal analysis, experimental procedure and testing results are discussed.
Findings
The effect of parameters such as multilayer insulation, helium gas charging pressure, compressor input voltage and cooling load was investigated. The performance of gold-plated and aluminized multilayer insulation is checked. The tests were done with multilayer insulation covering inside and outside the Perspex cover.
Practical implications
By using aluminized multilayer insulation inside and outside the Perspex cover, the improvement of 16 K in cool-down temperature was achieved. The cryocooler is charged with helium gas. The pressure varies between 14 and 18 bar. The optimum cooling is obtained for 17 bar gas pressure. The piston stroke increased as the compressor voltage increased, resulting in total helium gas compression. The optimum cool-down temperature was attained at 85 V.
Originality/value
The cryocooler is designed to achieve the cool-down temperature of 2 W cooling load at 100 K. The lowest cool-down temperature recorded was 105 K at a 2 W cooling load. Multilayer insulation is the major item that keeps the thermal radiation from the sun from reaching the copper tip.
Details
Keywords
Javad Babakhani and Farzad Veysi
The purpose of this article is to investigate the variables affecting heat transfer from the surfaces of a tall building and also the extent of the impact of each of them. Another…
Abstract
Purpose
The purpose of this article is to investigate the variables affecting heat transfer from the surfaces of a tall building and also the extent of the impact of each of them. Another purpose of this paper is to provide a suitable model for estimating the heat transfer coefficient of the external surfaces of the building according to the impact of variables.
Design/methodology/approach
In this study, the Taguchi's approach in the design of the experiments was used to reduce the number of experiments. Percent contributions factors into the overall and surface-averaged Nu of a square prism were obtained by the (ANOVA). The change in Nu by changing either of T, P, angle of attack and V were investigated by the (ANOM). The most significant factors affecting the value Nu were also identified to facilitate the design of thermal systems by eliminating the factors imposing no significant effect on the response in the molding phase. The set of conditions under which the air properties remained unchanged was identified. Five correlations were formulated to predict Nu.
Findings
Models used in BES, in which the effects of T, P, A and geometrical effects are not accounted for, are not reliable. The air pressure was found to impose no significant effect on the overall Nu of the considered square prism. Studied in the range of 274–303 K, the air temperature imposed a significant effect on the overall Nu. The results of ANOVA show the significant role of Re to predict Nu of tall buildings.
Originality/value
This article is taken from a doctoral dissertation.
Details