CAN HEAD reduces stress analysis costs

Aircraft Engineering and Aerospace Technology

ISSN: 0002-2667

Article publication date: 1 June 2005

101

Keywords

Citation

(2005), "CAN HEAD reduces stress analysis costs", Aircraft Engineering and Aerospace Technology, Vol. 77 No. 3. https://doi.org/10.1108/aeat.2005.12777cad.007

Publisher

:

Emerald Group Publishing Limited

Copyright © 2005, Emerald Group Publishing Limited


CAN HEAD reduces stress analysis costs

CAN HEAD reduces stress analysis costs

Keywords: Stress (materials)

HBM's CANHEAD system is reported to give large cost savings when conducting experimental stress analysis tests by removing the need to fit expensive connection cables. The cost savings are increased when there are hundreds or thousands of measuring points needed for the tests (Plate 1).

Plate 1 HBM's CANHEAD system gives large cost savings when conducting experimental stress analysis tests

CANHEAD works by making the base module independent of the amplifier module. This benefits users because the amplifiers can be fitted close to the measuring points, significantly reducing the amount of cabling needed compared with a standard installation. Data gathered during the tests are transmitted via standard CANbus systems to the base module.

In addition to reducing the cabling needed, CANHEAD allows test preparation to take place before the amplifier is installed. As an added advantage, the amplifier can be disconnected at any time without the intelligent base module losing its data.

Each CANHEAD is designed for ten channels and has an analogue to digital (A/D) converter on each channel allowing all measurement data to be acquired synchronously. An additional channel is available for temperature compensation using a strain gage or resistor.

Data from up to 12 CANHEADs can be transmitted over a single CANbus line using CanOpen protocol. The system's amplifiers operate at 600Hz carrier frequency to eliminate thermal voltages at the contact points and DC- voltage drift. Bridge excitation voltages of 0.5, 1 and 2.5V are available.

HBM's ML74 communication module is used as the master for uploading data to an MGCplus or MGCsplit system and, for users of the catman measurement software, the system provides Plug & Play compatibility.

CANHEAD has been used successfully in various applications leading to enhancements of HBM's product range to include, for example, a strain gage quarter bridge connection in four-wire technique.

Details available from: HBM, UK. Tel: +44 (0) 20 8515 6100; Fax: +44 (0) 20 8515 6149; e-mail: info@uk.hbm.com; web site: www.hbm.com

Related articles