To read this content please select one of the options below:

Is it reasonable to use high-strength concrete columns under fire conditions?

Oliver Bahr (Faculty of Civil Engineering, Jade Hochschule Wilhelmshaven∕Oldenburg∕Elsfleth-Studienort Oldenburg, Oldenburg, Germany)

Journal of Structural Fire Engineering

ISSN: 2040-2317

Article publication date: 19 August 2021

Issue publication date: 30 September 2021

83

Abstract

Purpose

This paper aims to answer two questions. First, are there any differences in the fire performance of columns made of normal and of high-strength concrete? Second, under which circumstances does the fire design govern the cross-sectional dimensions of concrete columns? Is it feasible to replace columns out of normal strength concrete by more slender high-strength concrete columns?

Design/methodology/approach

The author conducted numerical studies using the finite element code “Infocad” of the German company “Infograph”. The studies included the effect of different parameters on the fire performance of columns out of normal and high-strength concrete, i.e. the load ratio and eccentricity, boundary conditions and times of fire exposure.

Findings

Results from the numerical investigations showed that high-strength concrete columns suffer much more from heating than normal strength concrete columns. This is the outcome of the unfavourable mechanical properties of high-strength concrete at elevated temperatures. Although the relative fire performance of columns out of high-strength concrete is worse than that of columns out of normal strength concrete, initial load reserves are beneficial to achieve even high fire ratings.

Originality/value

Many researchers addressed in experimental and numerical studies the fire performance of columns out of normal and high-strength concrete. A special emphasis was often laid on the spalling of fire-exposed high-strength concrete. However, there are no systematic investigations when the fire design governs the cross-sectional dimensions of high-strength concrete columns. Based on a previous comparison of the relative fire performance of columns out of normal and high-strength concrete, this paper, hence, addresses the question whether there is a reasonable lower limit for the use of these columns. This is an important aspect for designers since there is a tendency to replace columns out of normal strength concrete by columns out of high-strength concrete. Higher concrete strengths allow for smaller cross sections of the columns, and designers may, hence, increase the usable space of buildings.

Keywords

Citation

Bahr, O. (2021), "Is it reasonable to use high-strength concrete columns under fire conditions?", Journal of Structural Fire Engineering, Vol. 12 No. 4, pp. 471-485. https://doi.org/10.1108/JSFE-02-2021-0011

Publisher

:

Emerald Publishing Limited

Copyright © 2021, Emerald Publishing Limited

Related articles