To read this content please select one of the options below:

Utilization of wavy porous layer, magnetic field and hybrid nanofluid with slot jet impingement on the cooling performance of conductive panel

Mohamed Ouni (Higher Institute of Medical Technologies of Tunis, University of Tunis El Manar, Tunis, Tunisia)
Fatih Selimefendigil (Department of Mechanical Engineering, Manisa Celal Bayar University, Manisa, Turkey)
Besbes Hatem (Department of Physics, Faculty of Science, King Abdulaziz University, Jeddah, Saudi Arabia)
Lioua Kolsi (Department of Mechanical Engineering, College of Engineering, University of Ha’il, Ha’il, Saudi Arabia and Laboratory of Meteorology and Energy Systems, University of Monastir, Monastir, Tunisia)
Mohamed Omri (Deanship of Scientific Research, King Abdulaziz University, Jeddah, Saudi Arabia)

International Journal of Numerical Methods for Heat & Fluid Flow

ISSN: 0961-5539

Article publication date: 14 July 2022

Issue publication date: 3 January 2023

126

Abstract

Purpose

The purpose of this study is to analyze the impacts of combined utilization of multi-jet impinging cooling of nanofluids with magnetic field and porous layer on the cooling performance, as effective cooling with impinging jets are obtained for various energy systems, including photovoltaic panels, electronic cooling and many other convective heat transfer applications.

Design/methodology/approach

Finite element method is used to explore the magnetic field effects with the inclusion of porous layer on the cooling performance efficiency of slot nanojet impingement system. Impacts of pertinent parameters such as Reynolds number (Re between 250 and 1,000), strength of magnetic field (Ha between 0 and 30), permeability of the porous layer (Da between 0.001 and 0.1) on the cooling performance for flat and wavy surface configurations are explored.

Findings

It is observed that the average Nusselt number (Nu) rises by about 17% and 20.4% for flat and wavy configuration while temperature drop of 4 K is obtained when Re is increased to 1,000 from 250. By using magnetic field at the highest strength, the average Nu rises by about 29% and 7% for flat and wavy cases. Porous layer permeability is an effective way of controlling the cooling performance while up to 44.5% variations in the average Nu is obtained by varying its value. An optimization routine is used to achieve the highest cooling rate while the optimum parameter set is obtained as (Re, Ha, Da, γ, sx) = (1,000, 30, 0.07558, 86.28, 2.585) for flat surface and (Re, Ha, Da, γ, sx) = (1,000, 30, 0.07558, 71.85, 2.329) for wavy surface configurations.

Originality/value

In thermal systems, cooling system design is important for thermal management of various energy systems, including fuel cells, photovoltaic panels, electronic cooling and many others. Impinging jets are considered as effective way of cooling because of its ability to give higher local heat transfer coefficients. This paper offers novel control tools, such as magnetic field, installation of porous layer and hybrid nano-liquid utilization for control of cooling performance with multiple impinging jets.

Keywords

Acknowledgements

This project was funded by the Deanship of Scientific Research (DSR), King Abdulaziz University, Jeddah, Saudi Arabia, under grant No. (D-17-305-1443). The authors, therefore, gratefully acknowledge DSR’s technical and financial support.

Citation

Ouni, M., Selimefendigil, F., Hatem, B., Kolsi, L. and Omri, M. (2023), "Utilization of wavy porous layer, magnetic field and hybrid nanofluid with slot jet impingement on the cooling performance of conductive panel", International Journal of Numerical Methods for Heat & Fluid Flow, Vol. 33 No. 1, pp. 360-384. https://doi.org/10.1108/HFF-03-2022-0192

Publisher

:

Emerald Publishing Limited

Copyright © 2022, Emerald Publishing Limited