Article
Publication date: 11 January 2022

Abdelkadir Fellouh, Abdelkader Bougara, Paulo Piloto and Nourredine Benlakehal

Investigate the fire performance of eccentrically loaded concrete partially encased column (PEC), using the advanced calculation method (ANSYS 18.2, 2017) and the simple…

Abstract

Purpose

Investigate the fire performance of eccentrically loaded concrete partially encased column (PEC), using the advanced calculation method (ANSYS 18.2, 2017) and the simple calculation method in Annex G of Eurocode 4 (EN 1994-1-2, 2005). This work examines the influence of a range of parameters on fire behaviour of the composite column including: eccentricity loading, slenderness, reinforcement, fire rating and fire scenario. In this study, ISO-834 (ISO834-1, 1999) was used as fire source.

Design/methodology/approach

Currently, different methods of analysis used to assess the thermal behaviour of composite column exposed to fire. Analytical method named simplified calculation methods defined in European standard and numerical simulations named advanced calculation models are treated in this paper.

Findings

The load-bearing capacity of the composite column becomes very weak in the presence of the fire accident and eccentric loading, this recommends to avoid as much as possible eccentric loading during the design of construction building. The reinforcement has a slight influence on the temperature evolution; moreover, the reinforcement has a great contribution on the load capacity, especially in combined compression and bending. When only the two concrete sides are exposed to fire, the partially encased composite column presents a high load-bearing capacity value.

Originality/value

The use of a three-dimensional numerical model (ANSYS) allowed to describe easily the thermal behaviour of PEC columns under eccentric loading with the regard to the analytical method, which is based on three complex steps. In this study, the presence of the load eccentricity has found to have more effect on the load-bearing capacity than the slenderness of the composite column. Introducing a load eccentricity on the top of the column may have the same a reducing effect on the load-bearing capacity as the fire.

Details

Journal of Structural Fire Engineering, vol. 13 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 23 March 2012

António Correia, João Rodrigues and Manfred Korzen

The composite steel and concrete columns are known to have enhanced fire behaviour when compared with bare steel columns. However there are still aspects that must be clarified…

50

Abstract

The composite steel and concrete columns are known to have enhanced fire behaviour when compared with bare steel columns. However there are still aspects that must be clarified, as the influence of the building surrounding structure on the fire resistance of the columns. In this paper, the results of fire resistance tests on partially encased steel columns carried out with two different experimental systems are compared. In one of the experimental systems, the building surrounding structure is materialised by a steel restraining frame, and in the other is performed by the so-called substructuring method. Due to the concept of hybrid substructuring, the entire building is decomposed in two parts: one is represented by the building element under test, whereas the remaining building is simulated numerically in a computer. The main conclusion drawn from this work was that the surrounding structure has a major influence in the development of axial forces in the test columns. Moreover, it was observed that the higher the non-dimensional axial restraint ratio the lower the critical time of the columns.

Details

Journal of Structural Fire Engineering, vol. 3 no. 1
Type: Research Article
ISSN: 2040-2317

Article
Publication date: 19 February 2013

Mimoune Mostefa, Ait Arezki and Bousbaa Fares

The case of a transverse load applied in the plane of profile is common in steel construction. Examples include the reaction at a simple support, the pressure of a roller on a…

Abstract

The case of a transverse load applied in the plane of profile is common in steel construction. Examples include the reaction at a simple support, the pressure of a roller on a beam of the raceway and the concentrated effort of compression provided by the compression flange in a column-beam joint. In this paper, the attention is focused on the study of the partially encased column web and flange in compression, by investigating the whole force displacement behavior of this component by means of an experimental program planned and carried out on eighteen specimens. Analytical formulations for predicting the resistance are analyzed. And the results obtained by the proposed formula are more aligned with the test results.

Details

World Journal of Engineering, vol. 10 no. 1
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 1 May 1955

The Corrosion Group of the Society of Chemical Industry had a gratifying high attendance at their symposium on ‘The Protection of Structural Steel,’ held in London on March 31 and…

Abstract

The Corrosion Group of the Society of Chemical Industry had a gratifying high attendance at their symposium on ‘The Protection of Structural Steel,’ held in London on March 31 and April 1 under the chairmanship of Dr. J. C. Hudson, of the British Iron and Steel Research Association. Well over 200 engineers, steel makers, steel users and paint and metal finish manufacturers and academic workers attended, together with an impressive foreign contingent from a number of countries. A wide variety of papers were delivered, followed by considerable discussion. Widespread interest was shown in the relative merits of paint and metal‐spraying protective techniques and particularly in the question of comparative costs. Reports of the papers delivered during the first day of the symposium are given below. These will be continued next month.

Details

Anti-Corrosion Methods and Materials, vol. 2 no. 5
Type: Research Article
ISSN: 0003-5599

Article
Publication date: 9 January 2024

Yunfei Zou

This study aims to enhance the understanding of fiber-reinforced polymer (FRP) applications in partially confined concrete, with a specific focus on improving economic value and…

Abstract

Purpose

This study aims to enhance the understanding of fiber-reinforced polymer (FRP) applications in partially confined concrete, with a specific focus on improving economic value and load-bearing capacity. The research addresses the need for a more comprehensive analysis of non-uniform vertical strain responses and precise stress–strain models for FRP partially confined concrete.

Design/methodology/approach

DIC and strain gauges were employed to gather data during axial compression tests on FRP partially confined concrete specimens. Finite element analysis using ABAQUS was utilized to model partial confinement concrete with various constraint area ratios, ranging from 0 to 1. Experimental findings and simulation results were compared to refine and validate the stress–strain model.

Findings

The experimental results revealed that specimens exhibited strain responses characterized by either hardening or softening in both vertical and horizontal directions. The finite element analysis accurately reflected the relationship between surface constraint forces and axial strains in the x, y and z axes under different constraint area ratios. A proposed stress–strain model demonstrated high predictive accuracy for FRP partially confined concrete columns.

Practical implications

The stress–strain curves of partially confined concrete, based on Teng's foundation model for fully confined stress–strain behavior, exhibit a high level of predictive accuracy. These findings enhance the understanding of the mechanical behavior of partially confined concrete specimens, which is crucial for designing and assessing FRP confined concrete structures.

Originality/value

This research introduces innovative insights into the superior convenience and efficiency of partial wrapping strategies in the rehabilitation of beam-column joints, surpassing traditional full confinement methods. The study contributes methodological innovation by refining stress–strain models specifically for partially confined concrete, addressing the limitations of existing models. The combination of experimental and simulated assessments using DIC and FEM technologies provides robust empirical evidence, advancing the understanding and optimization of FRP-concrete structure performance. This work holds significance for the broader field of concrete structure reinforcement.

Details

International Journal of Structural Integrity, vol. 15 no. 2
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 3 April 2024

Md. Ikramul Hoque, Muzamir Hasan and Shuvo Dip Datta

The stone dust column was used to strengthen the sample and had a significant effect on improving the shear strength of the kaolin clay. The application of stone columns, which…

Abstract

Purpose

The stone dust column was used to strengthen the sample and had a significant effect on improving the shear strength of the kaolin clay. The application of stone columns, which can improve the overall carrying capacity of soft clay as well as lessen the settlement of buildings built on it, is among the most widespread ground improvement techniques throughout the globe. The performance of foundation beds is enhanced by their stiffness values and higher strength, which could withstand more of the load applied. Stone dust is a wonderful source containing micronutrients for soil, particularly those derived from basalt, volcanic rock, granite and other related rocks. The aim of this paper is to evaluate the properties of soft clay reinforced with encapsulated stone dust columns to remediate problematic soil and obtain a more affordable and environmentally friendly way than using other materials.

Design/methodology/approach

In this study, the treated kaolin sample's shear strength was measured using the unconfined compression test (UCT). 28 batches of soil samples total, 12 batches of single stone dust columns measuring 10 mm in diameter and 12 batches of single stone dust columns measuring 16 mm in diameter. Four batches of control samples are also included. At heights of 60 mm, 80 mm and 100 mm, respectively, various stone dust column diameters were assessed. The real soil sample has a diameter of 50 mm and a height of 100 mm.

Findings

Test results show when kaolin is implanted with a single encased stone dust column that has an area replacement ratio of 10.24% and penetration ratios of 0.6, 0.8 and 1.0, the shear strength increase is 51.75%, 74.5% and 49.20%. The equivalent shear strength increases are 48.50%, 68.50% and 43.50% for soft soil treated with a 12.00% area replacement ratio and 0.6, 0.8 and 1.0 penetration ratios.

Originality/value

This study shows a comparison of how sample types affect shear strength. Also, this article provides argumentation behind the variation of soil strength obtained from different test types and gives recommendations for appropriate test methods for soft soil.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 24 September 2010

Jörg Lange and Ninja Wohlfeil

To establish a basis for calculating the load-bearing capacity of steel members made of S460 in a fire, corresponding to EN 1993-1-2, the mechanical properties of the…

Abstract

To establish a basis for calculating the load-bearing capacity of steel members made of S460 in a fire, corresponding to EN 1993-1-2, the mechanical properties of the micro-alloyed grain refined steel S460 under high temperatures have been examined. Two different types of steel have been considered: a normalized rolled S460 N and a thermo-mechanically rolled S460 M, that differ in their chemical composition and the temperature control during the hot-rolling process. On the basis of transient warm-creep tests, constitutive laws have been derived for the temperature range 20-900°C. The testresults show an increased strength of S460 M at elevated temperatures in comparison to S460 N. This is a result of the strain hardening caused by the thermo-mechanical rolling and the reduction of the creep-velocity caused by niobium- and titanium-precipitations. The data derived from the tests show that the stress-strain curves given in EN 1993-1-2 for S460 overestimate both the strength and the stiffness of the examined S460 N.

Details

Journal of Structural Fire Engineering, vol. 1 no. 3
Type: Research Article
ISSN: 2040-2317

Article
Publication date: 27 September 2022

Chafika Ali Ahmed, Abdelmadjid Si Salem, Souad Ait Taleb and Kamal Ait Tahar

This paper aims to investigate the experimental behavior and the reliability of concrete columns repaired using fiber-reinforced polymers (FRPs) under axial compression loading…

Abstract

Purpose

This paper aims to investigate the experimental behavior and the reliability of concrete columns repaired using fiber-reinforced polymers (FRPs) under axial compression loading. The expression of the ultimate axial resistance was assessed from the experimental data of damaged concrete cylinders repaired by externally bonded double-FRP spiral strips.

Design/methodology/approach

The tested columns bearing capacity mainly depends of the elasticity modulus of both damaged and undamaged concrete have been considered in addition to the applied load and the cylinder diameter as random variables in the expression of the failure criterion. The reliability indicators were assessed using first order second moment method.

Findings

The emphasized test results, statistically fitted show that the strength has been retrofitted for all repaired specimens whatever the degree of initial damage. However, the gain in axial strength is inversely proportional to the degree of damage.

Originality/value

The efficiency of a new FRP repair procedure using double-spiral strips was studied. This research provides a technical and economical solution for retrofitting existing concrete columns. Finally, the random character of the variables that govern the studied system shows the accuracy and safety of the proposed original design.

Details

World Journal of Engineering, vol. 21 no. 1
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 11 July 2017

Chrysanthos Maraveas

The DELTA® beam composite floor system is a recently developed shallow floor type that has seen many applications in contemporary construction. It involves partially encasing

Abstract

Purpose

The DELTA® beam composite floor system is a recently developed shallow floor type that has seen many applications in contemporary construction. It involves partially encasing DELTA® steel beams in concrete, with the lower flange remaining exposed. Besides the satisfactory behavior of the system at ambient conditions, understanding its response under elevated temperatures is critical in evaluating its overall performance. Despite certification from the manufacturing company that the system has adequate fire resistance, its behavior under fire conditions has neither been investigated to depth nor reported in detail. The purpose of this paper is the detailed numerical investigation of their behavior in fire. For this reason, the finite element method was implemented in this paper to simulate the response of such beams subjected to fire. Material properties were modeled according to the Eurocodes. The coupled thermal-structural parametric analyses involved four different variations of the “shortest” and “deepest” cross-section (eight case studies in total) specified by the manufacturing company. Other simulations of these cross-sections, in which either the thermal expansion or the structural load were not taken into account, were carried out for comparison purposes.

Design/methodology/approach

The methodology for simulating such systems, which has been successfully implemented and validated against fire test results elsewhere (Maraveas et al., 2012) was also followed here. To investigate the statement made by Maraveas et al. (2014) and the equations proposed by Zaharia and Franssen (2012) that the insulation is not so effective for “short” cross-sections, two beams, one with a D20-200 (Deltabeam Technical Manual, 2013) cross-section (shallowest section) and one with a D50-600 (Deltabeam Technical Manual, 2013) cross-section (deepest section), were simulated in this paper for comparison purposes. Additionally, reasonable assumptions were made for the cross-sectional dimensions not specified by the manufacturer (Deltabeam Technical Manual, 2013) and parametric analyses were carried out to investigate their effect on the structural response of the system.

Findings

Composite DELTA® beams can achieve fire resistances ranging from 120 to 180 min, depending on the depth and geometry of their cross-section, with deeper sections displaying a better fire response. The intense thermal bowing that occurs when these beams are heated from below has a more pronounced effect, in terms of thermally induced deflections for deeper sections. The satisfactory fire resistance of these beams is achieved due to the action of the concrete encased web and the reinforcement which compensate for the loss of the exposed lower flange. Increasing the thickness of the web in deeper sections improves their fire rating up to 180 min. The thickness of the lower flange affects the fire rating of the beams only in a minor way.

Practical/implications

The paper describes a numerical methodology to estimate the fire resistance of complex flooring systems.

Details

Journal of Structural Fire Engineering, vol. 8 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 10 January 2018

Oliver Bahr

The purpose of this study is to gain a deeper understanding of the structural behaviour of fire-exposed unbraced composite frames. Designers to date paid little attention to…

Abstract

Purpose

The purpose of this study is to gain a deeper understanding of the structural behaviour of fire-exposed unbraced composite frames. Designers to date paid little attention to unbraced one-bay composite frames as structural system. There are two main reasons for this. First, codes lack simplified methods for the fire design of these frames due to their sway and the linked P-Δ effects when subjected to fire, which complicates the design. Second, it is demanding to construct external composite joints for the regarded one-bay frames. Thus, external joints in composite constructions are mostly constructed as steel joints. Nevertheless, these frames offer advantages. These include increased usable space and flexibility in the building’s use, large spans, fast construction times and inherent fire resistance.

Design/methodology/approach

To profit from these benefits, two different external semi-rigid composite joint were developed for the considered one-bay composite frames. The first solution based on concrete-filled steel tube columns and the second on concrete-filled double skin tube columns. Furthermore, a numerical model was established to study the fire performance of unbraced composite frames. The model was validated against four fire tests on isolated composite joints and two large-scale fire tests on unbraced composite frames.

Findings

Overall, the predictions of the numerical model were in good agreement with the test results. Thus, the numerical model is appropriate for further investigations on the fire performance of unbraced composite frames.

Originality/value

The sequence of construction results in significant stresses in the steel section, which creates difficulties in numerical modelling and may account for the relatively few studies carried out at room temperature. For the fire design, there was, to the best knowledge of the author, to date no numerical model available that was capable of considering the sequence of construction.

Details

Journal of Structural Fire Engineering, vol. 9 no. 4
Type: Research Article
ISSN: 2040-2317