Article
Publication date: 31 December 2018

Seyed Foad Mousavi, Seyed Hassan Hashemabadi and Hossein Azizi Moghaddam

Invasive transit-time ultrasonic flow measurement involves the use of ultrasonic transducers, which sense the flowing fluid and are the most important parts of an ultrasonic

Abstract

Purpose

Invasive transit-time ultrasonic flow measurement involves the use of ultrasonic transducers, which sense the flowing fluid and are the most important parts of an ultrasonic flowmeter. In this study, two ultrasonic transducers were designed, numerically simulated and fabricated to be used in an ultrasonic gas flowmeter.

Design/methodology/approach

PZT-5H piezoceramic elements with specific dimensions were designed and used as beating heart inside the transducers. Different methods, including impedance-frequency analysis, optical emission spectroscopy and performance tests in pressurized chambers were used to evaluate the piezoelectric elements, ultrasonic transducer housings and the fabricated transducers, respectively. In addition, finite element method results showed its ability for design stages of ultrasonic transducer.

Findings

Experimental results for transit time difference (TTD) and the normalized received voltage were compared with simulation results at the same conditions. There was a quite good agreement between the two method results. Extensive simulation results showed that under the considered range of environmental conditions, the change of acoustic path length has the most impact on TTD, with respect to temperature and pressure. A change of 1 mm in acoustic path length leads to 0.74 per cent change in TTD, approximately. In addition, for normalized received voltage, 1 bar change in pressure has the most impact and its value is as high as 3.76 per cent.

Practical implications

This method is possibly used in ultrasonic gas flowmeter fabrication.

Originality/value

In this work, design, fabrication, experimental tests and numerical simulation of ultrasonic transducers are presented.

Article
Publication date: 22 March 2013

Yanqiang Feng, Haijiang Zhu and Ping Yang

This paper aims to characterize the acoustic field radiated by the piston transducer and measure a few parameters through the data visualization method.

Abstract

Purpose

This paper aims to characterize the acoustic field radiated by the piston transducer and measure a few parameters through the data visualization method.

Design/methodology/approach

Using the theoretical model of the ultrasonic transducer, the acoustic field data were acquired by scanning the ultrasound field of the piston transducer. And the visualized graphs of the ultrasonic data were displayed through 3D graphs including slice, iso‐surface and volume rendering, respectively. Furthermore, a few parameters of the transducer including beam width and spread angle were measured using the visualized data.

Findings

The visualized graphs of the acoustic field radiated by the piston transducer show that the data visualization method can expose obviously the space distribution of the ultrasound field and describe directly the cylindrical shape. And this method provides the basis of reliable measurement and assess for the ultrasonic transducer.

Research limitations/implications

This paper presents a kind of measured method of the acoustic parameters using the visualized data. The measurement range has limitation.

Practical implications

This method is possible used in Medical ultrasonic.

Originality/value

This paper presents the visualized description of the acoustic field of the piston transducer and a measurement of two acoustic parameters using the visualized data.

Article
Publication date: 13 June 2019

Rui Zhang, Lei Zhao, Dan Xie, Jinlong Song, Wendong Zhang, Lihu Pan and Yanhua Zhang

This study aims to simulate and test the performance of a transmitting and receiving capacitive micro-machined ultrasonic transducer (CMUT). Aimed at detecting demand of the CMUT…

186

Abstract

Purpose

This study aims to simulate and test the performance of a transmitting and receiving capacitive micro-machined ultrasonic transducer (CMUT). Aimed at detecting demand of the CMUT, a matched integrated adjustment circuit was designed through analyzing processing methods of transducer’s weak echo signal.

Design/methodology/approach

Based on the analysis of CMUT array structure and work principle, the CMUT units are designed and the dynamic performance analysis of SIMULINK is given according to the demand of underwater detecting. A transceiver isolation circuit is used to make transmission mode and receiving mode separate. A detection circuit is designed based on the transimpedance amplifier to achieve extraction of high-frequency and weak signal.

Findings

Through experimentation, the effectiveness of the CMUT performance simulation and the transceiver integrated adjustment circuit were verified. In addition, the test showed that CMUT with 400 kHz frequency has wider bandwidth and better dynamic characteristics than other similar transducers.

Originality/value

This paper provides a theoretical basis and design reference for the development and application of CMUT technology.

Article
Publication date: 17 June 2020

Seyed Foad Mousavi, Seyed Hassan Hashemabadi and Jalil Jamali

The purpose of this study is to numerically simulate the Lamb wave propagation through a clamp-on ultrasonic gas flowmeter (UGF) in contact mode, using a new semi…

120

Abstract

Purpose

The purpose of this study is to numerically simulate the Lamb wave propagation through a clamp-on ultrasonic gas flowmeter (UGF) in contact mode, using a new semi three-dimensional approach. Moreover, experimental and analytical modeling results for transit time difference method have been used to confirm the simulation results at different gas flow velocities from 0.3 to 2.4 m/s.

Design/methodology/approach

The new semi three-dimensional approach involves the simulation of the flow field of the gas in a three-dimensional model and subsequently the simulation of wave generation, propagation and reception in a two-dimensional (2D) model. Moreover, the analytical model assumes that the wave transitions occur in a 2D mode.

Findings

The new approach is a semi three-dimensional approach used in this work, has better accuracy than a complete 2D simulation while maintaining the computing time and costs approximately constant. It is faster and less expensive than a complete 3D simulation and more accurate than a complete 2D simulation. It was concluded that the new approach could be extended to simulate all types of ultrasonic gas and non-gas flowmeters, even under harsh conditions.

Originality/value

In this work, a new approach for the numerical simulation of all types of ultrasonic flowmeters is introduced. It was used for simulation of a Lamb wave ultrasonic flow meter in contact mode.

Article
Publication date: 12 September 2019

Hongliang Wang, Xiangjun Wang, Changde He and Chenyang Xue

As a new type of ultrasonic transducer with significant advantages, capacitive micromachined ultrasonic transducer (CMUT) has good application prospect. The reception…

Abstract

Purpose

As a new type of ultrasonic transducer with significant advantages, capacitive micromachined ultrasonic transducer (CMUT) has good application prospect. The reception characteristic of the CMUT is one of the important factors determining the application effect. This paper aims to study the reception characteristics of CMUT.

Design/methodology/approach

In this paper, the state equation is deduced and the analysis model is established in SIMULINK environment based on the lumped parameter system model of the CMUT cell. Based on this analysis model, the influencing factors of CMUT reception characteristics are studied and investigated, and the time-domain and frequency-domain characteristics are investigated in detail.

Findings

The analysis results show that parameters directly affect the reception characteristics of the CMUT, such as direct current (DC) bias voltage, input sound pressure amplitude and frequency. At the same time, the measurement system is built and the reception characteristics are verified.

Originality/value

This paper provides an effective method for rapid analyzing the reception characteristics of CMUT. These results provide an important theoretical basis and reference for further optimization of CMUT structure design, and lay a good foundation for the practical application measurement.

Details

Sensor Review, vol. 40 no. 2
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 1 September 1974

In the last two decades, ultrasonics has taken a firm grip on most cleaning problems: in some cases as a substitute for accepted mechanical methods and in others as an aid to…

Abstract

In the last two decades, ultrasonics has taken a firm grip on most cleaning problems: in some cases as a substitute for accepted mechanical methods and in others as an aid to speed up the process of cleaning, making it more efficient and therefore more cost effective.

Details

Anti-Corrosion Methods and Materials, vol. 21 no. 9
Type: Research Article
ISSN: 0003-5599

Article
Publication date: 31 December 2020

Tomasz Rymarczyk, Konrad Kania, Michał Gołąbek, Jan Sikora, Michał Maj and Przemysław Adamkiewicz

The purpose of this study is to develop a reconstruction and measurement system for data analysis using ultrasonic transmission tomography. The problem of reconstruction from the…

Abstract

Purpose

The purpose of this study is to develop a reconstruction and measurement system for data analysis using ultrasonic transmission tomography. The problem of reconstruction from the projection is encountered in practical implementation, which consists in reconstructing an image that is an estimation of an unknown object from a finite set of projection data. Reconstructive algorithms used in transmission tomography are based on linear mathematical models, which makes it necessary to process non-linear data into estimates for a finite number of projections. The application of transformation methods requires building a mathematical model in which the projection data forming the known and unknown quantities are functions with arguments from a continuous set of real numbers, determining the function describing the unknown quantities sought in the form of inverse relation and adapting it to operate on discrete and noisy data. This was done by designing a tomographic device and proprietary algorithms capable of reconstructing two-dimensional images regardless of the size, shape, location or number of inclusions hidden in the examined object.

Design/methodology/approach

The application consists of a device and measuring sensors, as well as proprietary algorithms for image reconstruction. Ultrasonic transmission tomography makes it possible to analyse processes occurring in an object without interfering with the examined object. The proposed solution uses algorithms based on ray integration, the Fermat principle and deterministic methods. Two applications were developed, one based on C and implemented on the embedded device, while the other application was made in Matlab.

Findings

Research shows that ultrasonic transmission tomography provides an effective analysis of tested objects in closed tanks.

Research limitations/implications

In the presented technique, the use of ultrasonic absorption wave has been limited. Nevertheless, the effectiveness of such a solution has been confirmed.

Practical implications

The presented solution can be used for research and monitoring of technological processes.

Originality/value

Author’s tomographic system consisting of a measuring system and image reconstruction algorithms.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. 40 no. 2
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 16 January 2017

Xuan Song, Zeyu Chen, Liwen Lei, Kirk Shung, Qifa Zhou and Yong Chen

Conventional machining methods for fabricating piezoelectric components such as ultrasound transducer arrays are time-consuming and limited to relatively simple geometries. The…

1092

Abstract

Purpose

Conventional machining methods for fabricating piezoelectric components such as ultrasound transducer arrays are time-consuming and limited to relatively simple geometries. The purpose of this paper is to develop an additive manufacturing process based on the projection-based stereolithography process for the fabrication of functional piezoelectric devices including ultrasound transducers.

Design/methodology/approach

To overcome the challenges in fabricating viscous and low-photosensitive piezocomposite slurry, the authors developed a projection-based stereolithography process by integrating slurry tape-casting and a sliding motion design. Both green-part fabrication and post-processing processes were studied. A prototype system based on the new manufacturing process was developed for the fabrication of green-parts with complex shapes and small features. The challenges in the sintering process to achieve desired functionality were also discussed.

Findings

The presented additive manufacturing process can achieve relatively dense piezoelectric components (approximately 95 per cent). The related property testing results, including X-ray diffraction, scanning electron microscope, dielectric and ferroelectric properties as well as pulse-echo testing, show that the fabricated piezo-components have good potentials to be used in ultrasound transducers and other sensors/actuators.

Originality/value

A novel bottom-up projection system integrated with tape casting is presented to address the challenges in the piezo-composite fabrication, including small curing depth and viscous ceramic slurry recoating. Compared with other additive manufacturing processes, this method can achieve a thin recoating layer (as small as 10 μm) of piezo-composite slurry and can fabricate green parts using slurries with significantly higher solid loadings. After post processing, the fabricated piezoelectric components become dense and functional.

Details

Rapid Prototyping Journal, vol. 23 no. 1
Type: Research Article
ISSN: 1355-2546

Keywords

Article
Publication date: 1 March 1994

Simmy Grewal

Looks at the development of a new ultrasonic meter for the gas supplyindustry and explaining the transit time measurement principle on which itworks and the performance…

164

Abstract

Looks at the development of a new ultrasonic meter for the gas supply industry and explaining the transit time measurement principle on which it works and the performance characteristics of the new meter. Concludes that the ultrasound gas meter could also have medical applications including anaesthetics and hospital ward monitoring. There have been limited production runs of the new gas meter and extensive trials are taking place in several countries.

Details

Sensor Review, vol. 14 no. 1
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 21 June 2021

Tian Zhang, Wendong Zhang, XingLing Shao and Yang Wu

Because of the small size and high integration of capacitive micromachined ultrasonic transducer (CMUT) component, it can be made into large-scale array, but this lead to high…

123

Abstract

Purpose

Because of the small size and high integration of capacitive micromachined ultrasonic transducer (CMUT) component, it can be made into large-scale array, but this lead to high hardware complexity, so the purpose of this paper is to use less elements to achieve better imaging results. In this research, an optimized sparse array is studied, which can suppress the side lobe and reduce the imaging artifacts compared with the equispaced sparse array with the same number of elements.

Design/methodology/approach

Genetic algorithm is used to sparse the CMUT linear array, and Kaiser window apodization is added to reduce imaging artifacts, the beam pattern and peak-to-side lobe ratio are calculated, point targets imaging comparisons are performed. Furthermore, a 256-elements CMUT linear array is used to carry out the imaging experiment of embedded mass and forearm blood vessel, and the imaging results are compared quantitatively.

Findings

Through the imaging comparison of embedded mass and forearm blood vessel, the feasibility of optimized sparse array of CMUT is verified, and the purpose of reducing the hardware complexity is achieved.

Originality/value

This research provides a basis for the large-scale CMUT array to reduce the hardware complexity and the amount of calculation. At present, the CMUT array has been used in medical ultrasound imaging and has huge market potential.

Details

Sensor Review, vol. 41 no. 3
Type: Research Article
ISSN: 0260-2288

Keywords