Search results

1 – 10 of 40
Article
Publication date: 16 November 2023

Abdeldjabar Benrabah, Farid Khoucha, Ali Raza and Mohamed Benbouzid

The purpose of this study is to improve the control performance of wind energy conversion systems (WECSs) by proposing a new sensorless, robust control strategy based on a Smith…

Abstract

Purpose

The purpose of this study is to improve the control performance of wind energy conversion systems (WECSs) by proposing a new sensorless, robust control strategy based on a Smith predictor active disturbance rejection control (SP-ADRC) associated with a speed/position estimator.

Design/methodology/approach

The estimator consists of a sliding mode observer (SMO) in combination with a phase-locked loop (PLL) to estimate the permanent magnet synchronous generator (PMSG) rotor position and speed. At the same time, the SP-ADRC is applied to the speed control loop of the variable-speed WECS control system to adapt strongly to dynamic characteristics under parameter uncertainties and disturbances.

Findings

Numerical simulations are conducted to evaluate the speed tracking performances under various wind speed profiles. The results show that the proposed sensorless speed control improves the accuracy of rotor speed and position estimation and provides better power tracking performance than a regular ADRC controller under fast wind speed variations.

Practical implications

This paper offers a new approach for designing sensorless, robust control for PMSG-based WECSs.

Originality/value

A new sensorless, robust control is proposed to improve the stability and tracking performance of PMSG-based WECSs. The SP-ADRC control attenuates the effects of parameter uncertainties and disturbances and eliminates the time-delay impact. The sensorless control design based on SMO and PLL improves the accuracy of rotor speed estimation and reduces the chattering problem of traditional SMO. The obtained results support the theoretical findings.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. 42 no. 6
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 19 April 2024

Halil Deligöz

This study aims to define a “technological statecraft” concept to distinguish tech-based measures/sanctions from an array of economic measures ranging from restrictions of rare…

Abstract

Purpose

This study aims to define a “technological statecraft” concept to distinguish tech-based measures/sanctions from an array of economic measures ranging from restrictions of rare earth elements and natural gas supplies to asset freezes under the wider portfolio of economic statecraft. This concept is practically intended to reveal the USA’s “logic of choice” in its employment of technology as an efficient instrument to deal with China in the context of the great power rivalry.

Design/methodology/approach

This study follows David A. Baldwin’s statecraft definition and conceptualization methodology, which relies on “means” rather than “ends.” In addition to Baldwin and as an incremental contribution to his economic statecraft analysis, this study also combines national political economy with statecraft analysis with a particular focus on the utilization of technological measures against China during the Trump administration.

Findings

The US rationale for choosing technology, namely, emerging and foundational technologies, in its rivalry against China is caused at least by two factors: the nature of the external challenge and the characteristics of the US innovation model based largely on radical innovations. To deal with China, the USA practically distinguished the role of advanced technology and followed a grammer of technological statecraft as depicted in the promulgated legal texts during the Trump administration.

Originality/value

Despite a growing volume of literature on economic statecraft and technological competition, studies focusing on countries’ “logic of choice” with regard to why and under what conditions they choose financial, technological or commodity-based sanctions/measures/controls are lacking. Inspired from Baldwin’s account on the “logic of choice” from among alternative statecrafts (i.e. diplomacy, military, economic statecraft, and propaganda). This study will contribute to the literature with a clear lens to demonstrate the “logic of choice” from among a variety of economic statecraft measures in the case of the US technological statecraft toward China.

Details

Journal of International Trade Law and Policy, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1477-0024

Keywords

Article
Publication date: 31 October 2023

Lei Xiong, Hongjun Shi and Qixin Zhu

This study aims to construct a novel maximum power tracking control system for the direct drive permanent magnet synchronous generator (PMSG) of the wind energy conversion system…

Abstract

Purpose

This study aims to construct a novel maximum power tracking control system for the direct drive permanent magnet synchronous generator (PMSG) of the wind energy conversion system (WECS) to solve the following problems: how to effectively eliminate the system’s model parameter disturbances and speed up the dynamic performance of the system; and how to eliminate harmonics in WECS under different wind speeds.

Design/methodology/approach

To obtain the maximum output power of PMSG at WECS under different wind speeds, the following issues should be considered: (1) how to effectively eliminate the system’s model parameter disturbances and speed up the dynamic performance of the system; and (2) how to suppress system harmonics. For Problem 1, adding dq compensation factors to active disturbance rejection control (ADRC) for the current loop realizes the dq axis decoupling control, which speeds up the dynamic performance of the system. For Problem 2, the resonant controller is introduced into the ADRC for the current loop to suppress harmonic current in WECS under different wind speeds.

Findings

The simulation results demonstrate that the proposed control method is simpler and more reliable than conventional controllers for maximum power tracking.

Originality/value

Compared with traditional controllers, the proposed controller can speed up the dynamic performance of the system and suppress the current harmonic effectively, thus better achieving maximum power tracking.

Details

Robotic Intelligence and Automation, vol. 43 no. 6
Type: Research Article
ISSN: 2754-6969

Keywords

Article
Publication date: 3 April 2023

Sebi Neelamkavil Pappachan

This study aims to intend and implement the optimal power flow, where tuning the production cost is done with the inclusion of stochastic wind power and different kinds of…

Abstract

Purpose

This study aims to intend and implement the optimal power flow, where tuning the production cost is done with the inclusion of stochastic wind power and different kinds of flexible AC transmission systems (FACTS) devices. Here, the speed with fitness-based krill herd algorithm (SF-KHA) is adopted for deciding the FACTS devices’ optimal sizing and placement integrated with wind power. Here, the modified SF-KHA optimizes the sizing and location of FACTS devices for attaining the minimum average production cost and real power depletions of the system. Especially, the objective includes reserve cost for overestimation, cost of thermal generation of the wind power, direct cost of scheduled wind power and penalty cost for underestimation. The efficiency of the offered method over several popular optimization algorithms has been done, and the comparison over different algorithms establishes proposed KHA algorithm attains the accurate optimal efficiency for all other algorithms.

Design/methodology/approach

The proposed FACTS devices-based power system with the integration of wind generators is based on the accurate placement and sizing of FACTS devices for decreasing the actual power loss and total production cost of the power system.

Findings

Through the cost function evaluation of the offered SF-KHA, it was noted that the proposed SF-KHA-based power system had secured 13.04% superior to success history-based adaptive differential evolution, 9.09% enhanced than differential evolution, 11.5% better than artificial bee colony algorithm, 15.2% superior to particle swarm optimization and 9.09% improved than flower pollination algorithm.

Originality/value

The proposed power system with the accurate placement and sizing of FACTS devices and wind generator using the suggested SF-KHA was effective when compared with the conventional algorithm-based power systems.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. 42 no. 6
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 12 September 2023

Mingzhen Song, Lingcheng Kong and Jiaping Xie

Rapidly increasing the proportion of installed wind power capacity with zero carbon emission characteristics will help adjust the energy structure and support the realization of…

Abstract

Purpose

Rapidly increasing the proportion of installed wind power capacity with zero carbon emission characteristics will help adjust the energy structure and support the realization of carbon neutrality targets. The intermittency of wind resources and fluctuations in electricity demand has exacerbated the contradiction between power supply and demand. The time-of-use pricing and supply-side allocation of energy storage power stations will help “peak shaving and valley filling” and reduce the gap between power supply and demand. To this end, this paper constructs a decision-making model for the capacity investment of energy storage power stations under time-of-use pricing, which is intended to provide a reference for scientific decision-making on electricity prices and energy storage power station capacity.

Design/methodology/approach

Based on the research framework of time-of-use pricing, this paper constructs a profit-maximizing electricity price and capacity investment decision model of energy storage power station for flat pricing and time-of-use pricing respectively. In the process, this study considers the dual uncertain scenarios of intermittency of wind resources and random fluctuations in power demand.

Findings

(1) Investment in energy storage power stations is the optimal decision. Time-of-use pricing will reduce the optimal capacity of the energy storage power station. (2) The optimal capacity of the energy storage power station and optimal electricity price are related to factors such as the intermittency of wind resources, the unit investment cost, the price sensitivities of the demand, the proportion of time-of-use pricing and the thermal power price. (3) The carbon emission level is affected by the intermittency of wind resources, price sensitivities of the demand and the proportion of time-of-use pricing. Incentive policies can always reduce carbon emission levels.

Originality/value

This paper creatively introduced the research framework of time-of-use pricing into the capacity decision-making of energy storage power stations, and considering the influence of wind power intermittentness and power demand fluctuations, constructed the capacity investment decision model of energy storage power stations under different pricing methods, and compared the impact of pricing methods on optimal energy storage power station capacity and carbon emissions.

Highlights

  1. Electricity pricing and capacity of energy storage power stations in an uncertain electricity market.

  2. Investment strategy of energy storage power stations on the supply side of wind power generators.

  3. Impact of pricing method on the investment decisions of energy storage power stations.

  4. Impact of pricing method, energy storage investment and incentive policies on carbon emissions.

  5. A two-stage wind power supply chain including energy storage power stations.

Electricity pricing and capacity of energy storage power stations in an uncertain electricity market.

Investment strategy of energy storage power stations on the supply side of wind power generators.

Impact of pricing method on the investment decisions of energy storage power stations.

Impact of pricing method, energy storage investment and incentive policies on carbon emissions.

A two-stage wind power supply chain including energy storage power stations.

Details

Industrial Management & Data Systems, vol. 123 no. 11
Type: Research Article
ISSN: 0263-5577

Keywords

Case study
Publication date: 6 December 2023

Sobhesh Kumar Agarwalla and Ajay Pandey

This case describes the growth of ReNew Power during its first decade of operation. Sumant Sinha, a first-generation entrepreneur and former banker, founded the company, which…

Abstract

This case describes the growth of ReNew Power during its first decade of operation. Sumant Sinha, a first-generation entrepreneur and former banker, founded the company, which grew from a modest generator-cum-developer of wind energy-based electricity to one of India's largest companies in the renewable energy sector. With the entry of large, well-funded players such as Tata Power and Adani Green into the Indian renewable sector by the end of 2020, Sinha had to make a strategic decision: should ReNew continue to organically scale up its presence in an increasingly competitive yet expanding Indian renewable energy sector, should it diversify geographically, or should it pursue emerging opportunities for vertical or horizontal integration within the sector? The case provides an opportunity to discuss how alternative business models and competitive scenarios may facilitate or inhibit the growth of a player in the renewable energy sector.

Details

Indian Institute of Management Ahmedabad, vol. no.
Type: Case Study
ISSN: 2633-3260
Published by: Indian Institute of Management Ahmedabad

Keywords

Article
Publication date: 3 March 2023

Shirin Hassanzadeh Darani, Payam Rabbanifar, Mahmood Hosseini Aliabadi and Hamid Radmanesh

The purpose of this paper is to present a new system frequency response model with participation of wind-hydro-thermal units to overcome frequency deviations.

Abstract

Purpose

The purpose of this paper is to present a new system frequency response model with participation of wind-hydro-thermal units to overcome frequency deviations.

Design/methodology/approach

The extracted minimum frequency equation is considered as a constraint in security-constrained unit commitment calculations. Because of high-order polynomials in the frequency transfer function and high degree of nonlinearity of minimum frequency constraint, Routh stability criterion method and piecewise linearization technique are used to reduce system order and linearize the system frequency response model, respectively.

Findings

The results of this paper indicate that by using this model, the hourly minimum frequency is improved and is kept within defined range.

Originality/value

This combined model can be used to evaluate the frequency of the power system following unexpected load increase or generation disturbances. It also can be used to investigate the system frequency performance and ensure power system security which are caused by peak load or loss of generation in presence of renewable energies.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. 42 no. 6
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 11 October 2023

Mano S. and Nadaraja Pillai S.

This study aims to investigate the effect of downstream characteristics of S809 wind turbine blade with various extended flat plate (EFP) configuration. Wind farms are recently…

Abstract

Purpose

This study aims to investigate the effect of downstream characteristics of S809 wind turbine blade with various extended flat plate (EFP) configuration. Wind farms are recently modified to improve the power production through placing number of wind turbines and locations.

Design/methodology/approach

A series of wind tunnel experiments were carried out to evaluate the downstream wake characteristics of the S809 airfoil attached with various EFP (EFP, A = 0.1C, 0.2C and 0.3C) at various angles of attack corresponding to free stream velocity Reynolds number (Re) = 2.11 × 105 and various turbulence intensity (TI = 5%, 7%, 10% and 12%).

Findings

For the S809 wind turbine blade attached with EFP, the downstream velocity ratio decreases with increasing in angle of attack and the velocity deficit decrease with increasing turbulence intensity (TI) up to TI = 10%. The wake intensity for the S809 wind turbine blade and S809 airfoil with 10% of chord EFP performs the same for each downstream location.

Practical implications

Placing the wind turbine in the wind park next to another wind turbine poses a potential challenge for the park power performance. This research addresses the characteristics of the downstream turbulence intensity profile modified with the EFP in the wind turbine blade which improves the downstream characteristics of the turbine in the wind park.

Originality/value

The downstream velocity ratio decreases with increasing angle of attack and the velocity deficit decrease with increasing turbulence intensity (TI) up to TI = 10%.

Details

Aircraft Engineering and Aerospace Technology, vol. 95 no. 10
Type: Research Article
ISSN: 1748-8842

Keywords

Article
Publication date: 21 March 2023

Manikandan R. and Raja Singh R.

The purpose of this paper is to prevent the destruction of other parts of a wind energy conversion system because of faults, the diagnosis of insulated-gate bipolar transistor…

Abstract

Purpose

The purpose of this paper is to prevent the destruction of other parts of a wind energy conversion system because of faults, the diagnosis of insulated-gate bipolar transistor (IGBT) faults has become an essential topic of study. Demand for sustainable energy sources has been prompted by rising environmental pollution and energy requirements. Renewable energy has been identified as a viable substitute for conventional fossil fuel energy generation. Because of its rapid installation time and adaptable expenditure for construction scale, wind energy has emerged as a great energy resource. Power converter failure is particularly significant for the reliable operation of wind power conversion systems because it not only has a high yearly fault rate but also a prolonged downtime. The power converters will continue to operate even after the failure, especially the open-circuit fault, endangering their other parts and impairing their functionality.

Design/methodology/approach

The most widely used signal processing methods for locating open-switch faults in power devices are the short-time Fourier transform and wavelet transform (WT) – based on time–frequency analysis. To increase their effectiveness, these methods necessitate the intensive use of computational resources. This study suggests a fault detection technique using empirical mode decomposition (EMD) that examines the phase currents from a power inverter. Furthermore, the intrinsic mode function’s relative energy entropy (REE) and simple logical operations are used to locate IGBT open switch failures.

Findings

The presented scheme successfully locates and detects 21 various classes of IGBT faults that could arise in a two-level three-phase voltage source inverter (VSI). To verify the efficacy of the proposed fault diagnosis (FD) scheme, the test is performed under various operating conditions of the power converter and induction motor load. The proposed method outperforms existing FD schemes in the literature in terms of fault coverage and robustness.

Originality/value

This study introduces an EMD–IMF–REE-based FD method for VSIs in wind turbine systems, which enhances the effectiveness and robustness of the FD method.

Article
Publication date: 30 March 2022

Karthick R., Ramakrishnan C. and Sridhar S.

This paper aims to introduce the quasi impedance source inverter (qZSI)-based static compensator (STATCOM), which is incorporated into the hybrid distributed power generation…

Abstract

Purpose

This paper aims to introduce the quasi impedance source inverter (qZSI)-based static compensator (STATCOM), which is incorporated into the hybrid distributed power generation system for enhancement of power quality. The distributed power generation system includes the photovoltaic (PV), wind energy conversion system (WECS) and battery energy storage system.

Design/methodology/approach

The WECS is used by the self-excited induction generator (SEIG) and the flywheel energy storage system (FESS). To regulate its terminal voltage and frequency, the SEIG requires adjustable volt-ampere reactive (VAR). A combination of a STATCOM and a fixed condenser bank usually serves to satisfy the VAR demand. The maximum correntropy criterion-based adaptive filter technique (AFT) is proposed to control the qZSI-STATCOM and to guarantee that the voltage at the SEIG terminal is harmonic-free while providing non-linear three-phase and single-phase loads.

Findings

The coordinated operation of the suggested voltage control and flywheel control systems ensures that load voltage and frequency are retained in their respective values at very low harmonic distortions regardless of wind speed and load variation. The simulation and experimental studies are carried out under different load conditions to validate the efficiencies of the PV-assisted STATCOM.

Originality/value

To improve system stability and minimize total costs, extra load current sensors can also be avoided. This paper proposes to control the SEIG terminal voltage and harmonic elimination in the standalone WECS systems using maximum correntropy criterion-based AFT with a fuzzy logic controller.

1 – 10 of 40