Search results

1 – 10 of over 14000
Article
Publication date: 20 May 2022

Fatimah De´nan, Nor Salwani Hashim and Amarpreet Kaur Mahinder Singh

Due to the enormous increase in economic development, structural steel material gives an advantage for the construction of stadiums, factories, bridges and cities building design…

Abstract

Purpose

Due to the enormous increase in economic development, structural steel material gives an advantage for the construction of stadiums, factories, bridges and cities building design. The purpose of this study is to investigate the behaviour of bending, buckling and torsion for I-beam steel section with and without web opening using non-linear finite element analysis.

Design/methodology/approach

The control model was simulated via LUSAS software with the four main parameters which included opening size, layout, shape and orientation. The analysis used a constant beam span which is 3.5 m while the edge distance from the centre of the opening to the edge of the beam is kept constant at 250 mm at each end.

Findings

The analysis results show that the optimum opening size obtained is 0.65 D while optimum layout of opening is Layout 1 with nine web openings. Under bending behaviour, steel section with octagon shapes of web opening shows the highest yield load, yield moment and thus highest structural efficiency as compared to other shapes of openings. Besides, square shape of web opening has the highest structural efficiency under buckling behaviour. The lower buckling load and buckling moment contribute to the higher structural efficiency.

Originality/value

Further, the square web opening with counter clockwise has the highest structural efficiency under torsion behaviour.

Details

World Journal of Engineering, vol. 20 no. 6
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 22 August 2023

Nor Salwani Hashim and Fatimah De'nan

Castellated and cellular beams achieved the same strength as solid I-beams with the same depth, resulting in significantly lighter and more economical structures. The purpose of…

Abstract

Purpose

Castellated and cellular beams achieved the same strength as solid I-beams with the same depth, resulting in significantly lighter and more economical structures. The purpose of this study is to analyse the bending behaviour of I-beam steel sections with certain web openings by finite element analysis.

Design/methodology/approach

The accuracy of finite element results allows extensive numerical analysis of sections with web openings, concentrating on the web opening sizes and web opening positions. These assumptions can increase the induced section load with various shapes of web opening depth and web opening shapes of c-hexagon, hexagon, octagon, circular and square. This also includes spacing distances, with a 50-mm edge and 150-mm centre-to-centre distance and a section with a 100-mm edge and 200-mm centre-to-centre distance. Generally, the adjustment of the opening geometry (by reducing the angle of web pitch or reducing the opening depth depending on analysed parameters) may influence the bending behaviour.

Findings

Additionally, Model 2 was found to be the optimum model compared to Model 1, mainly in terms of bending. Moreover, the I-beam with a c-hexagon shape opening exhibited the lowest displacement compared to other sections with other web opening shapes. Section with a different arrangement of web opening, Type E shows the lower displacement while higher displacement is observed for Type A and also higher displacement considered for Type G. The optimum model is associated with Type E, followed by Type D, compared to other types of certain web opening and I-beam.

Originality/value

The use of sections with different arrangements of web opening improved the performance of the perforated section in terms of structural behaviour, compared to typical I-beam, thus leading to economic design.

Details

World Journal of Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 17 May 2023

Fatimah De’nan, Nor Salwani Hashim and Mohd Yusri Mohamad Razak

Tapered steel sections are widely used in house building design due to their structural efficiency and aesthetic appearance. Due to the practical usage of web tapering…

Abstract

Purpose

Tapered steel sections are widely used in house building design due to their structural efficiency and aesthetic appearance. Due to the practical usage of web tapering specifications in the metal building industry, fabrication and material expenses are analyzed to achieve geometric and economic productivity. The purpose of this study is to investigate the effectiveness of utilizing web profiles with openings in reducing the weight of steel beams.

Design/methodology/approach

In this paper, the nonlinear analysis of the bending behavior of a tapered steel section with an opening was studied by finite element analysis. The results were then compared with those of the tapered steel section without an opening in terms of displacement and yield moment.

Findings

The bending capacity of a tapered steel section was analyzed using finite element analysis. Results showed that the tapered steel section without openings had a higher bending capacity compared to the section with various sizes of web openings. The results also showed that decreasing the number of openings would increase the bending capacity, whereas increasing the size of the opening would decrease it. The difference in the yield moment between the tapered steel section with and without openings was only 15.818%. A total of 60 nonlinear analyses were conducted to investigate the effect of the number and size of web openings, flange thickness and web thickness on the bending behavior. However, this study showed that web opening with octagon shape and 0.6D size of web opening, where D is the depth of section, showed the best section in terms of yield moment and volume reduction compared to other opening size and shape.

Originality/value

It is also found that tapered steel section has better moment resistance in thicker flange and web. The study is valuable for engineers and designers who work with steel structures and need to optimize the performance of tapered steel sections with web openings.

Details

World Journal of Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 11 January 2023

Nor Salwani Hashim and Fatimah De’nan

It is generally known that the perforated section such as the castellated section is good to sustain distributed loads but inadequate to sustain highly concentrated loads…

Abstract

Purpose

It is generally known that the perforated section such as the castellated section is good to sustain distributed loads but inadequate to sustain highly concentrated loads. Therefore, it is possible to design the opening in a different arrangement of web opening to achieve section efficiency, thus improving the strength and torsional behaviour of the section with web opening. This study aims to focus on the finite element analysis of I-beam with and without openings in steel section dominated to lateral-torsional buckling behaviour.

Design/methodology/approach

In this work, the analysis of different sizes, shapes and arrangements of web opening is performed by using LUSAS application to conduct numerical analysis on lateral-torsional buckling behaviour. This involves three diameter sizes of web opening, five types of opening shapes and two criteria of the model.

Findings

The section with c-hexagon web opening was placed about 200-mm centre to centre and 100-mm edge distance, contribute to 7.26% increase of buckling capacity. For the section with 150-mm centre to centre and 50-mm edge distance, the occurrence of local buckling contributes to decrease of lateral buckling section capacity to 19.943 kNm, where pure lateral-torsional buckling mostly occurred because of prevented section. Besides that, the web opening diameter was also analysed. The web crippling was observed because of the increase of opening diameter from 0.67 to 0.80 D.

Originality/value

This contributes to a decrease in buckling capacity as figured in the contour of the deformed shape. For Model 1, an increase of buckling capacity (31.46%) is observed when the opening diameter are changed from 0.67 to 0.80 D.

Details

World Journal of Engineering, vol. 21 no. 2
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 25 June 2019

Naveed Alam, Ali Nadjai, Olivier Vassart and Francois Hanus

In recent times, the use of steel sections with web openings has become common as slim floor beams because they offer a reduction in weight of the steelwork, accommodate services…

Abstract

Purpose

In recent times, the use of steel sections with web openings has become common as slim floor beams because they offer a reduction in weight of the steelwork, accommodate services within the floor depth and provide the composite action. The composite action in these beams is achieved either through the concrete dowels or through concrete plugs. Though these web openings offer several benefits in slim floor beams, they induce the material discontinuity in the steel web, which may affect their shear capacity and/or thermal behaviour. The purpose of this study is to investigate the thermal behaviour of slim floor beams with web openings in fire.

Design/methodology/approach

This research presents findings from experimental and analytical investigations conducted to study the thermal behaviour of slim floor beams with web openings in fire. For this purpose, an experimental investigation was conducted, which shows that the presence of web openings has a major influence on temperature development across the steel section as well as along the span of these beams. The behaviour of the tested slim floor beam is validated using finite element modelling. The validated finite element model is then used to conduct a sensitivity study to analyse the influence of different opening spacings, sizes and shapes on the thermal performance of slim floor beams in fire.

Findings

Test results show that the presence of web openings has a major influence on temperature development across the steel section as well as along the span of these beams. Temperatures on the web below the openings are found to be higher as compared to those recorded on the adjacent solid steel web. It is also observed that temperatures on the steel web above the openings are lesser than those on the adjacent solid steel web. Parametric studies conducted using the verified analytical modelling methods show that different opening spacings, sizes and shapes have a variable impact on the thermal behaviour of slim floor beams in fire. Closely spaced and larger opening sizes were found to have a more severe influence on their thermal behaviour in fire as compared to widely spaced and smaller openings. It was also found that the behaviour of these beams is influenced by the shape of the openings with rectangular openings resulting in more severe thermal distributions as compared to circular openings.

Originality/value

The findings from this research study are highly valuable as they contribute to the existing knowledge database. There is a lack of experimental and analytical investigation on performance of slim floor beams with web openings at elevated temperatures. The results and conclusions from this study will help in developing innovative designs for slim floor beams and will help in reducing the fire related risk associated with structures comprising of slim floor beams with web openings.

Details

Journal of Structural Fire Engineering, vol. 10 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 10 May 2022

Fatimah De'nan and Nor Salwani Hashim

The purpose of this work is to perform the finite element analysis (FEA) for the numerical discretization of sections with different arrangements of Web openings to investigate…

Abstract

Purpose

The purpose of this work is to perform the finite element analysis (FEA) for the numerical discretization of sections with different arrangements of Web openings to investigate the torsion behavior. Typical hexagonal and circular Web opening sections are extensively used in steel construction due to economic development in building design. However, the use of sections with different arrangements of Web opening had improved the performance of the section with Web opening in terms of structural behavior which leads to economic design compared to typical I-beam.

Design/methodology/approach

The accuracy of FE results allows extensive numerical analysis of stress concentration magnitude for sections with Web openings, concentrating on the sizes and positions of the Web opening. Five shapes and three sizes of Web opening are used in this work. The shapes involved are c-hexagon, hexagon, octagon, circular and square, whereas the sizes of the Web opening involved are 0.67 D, 0.75 D and 0.80 D where D is the height of the Web. Two types of models for 200 × 100 × 8×6 mm steel section involved which is Model 1, where the section with 50 mm edge and 150 mm center-to-center distance and Model 2, where the section with 100 mm edge and 200 mm center-to-center distance.

Findings

It was found that these configurations affect the section with various shapes of Web openings sizes (0.67 D, 0.75 D, and 0.80 D). This also includes the spacing distances, with 50 mm edge and 150 mm center-to-center distance and also a section with 100 mm edge and 200 mm center-to-center distance. Through the FEA results of Model 1 and Model 2, it is found that 50% reduction in horizontal member length in hexagon Web opening, from 50 mm to 20 mm, caused increment about 30%–53% stress concentration in Web for c-hexagon. However, for a stress analysis of c-hexagon, geometry resulted in a lower stress concentration in the Web than other Web opening.

Originality/value

Additionally, the work emphasized the efficiency of Web opening shapes by using an appropriate Web opening radius in section with c-hexagon, hexagon, octagon, square and circular shapes. The final results show the contribution of appropriate Web opening radius to increase the section torsional capacity. It is observed that the torsional capacity at certain loading condition and its angle of twist is analysed.

Details

World Journal of Engineering, vol. 20 no. 5
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 16 July 2021

Fatimah De’nan, Nor Salwani Hashim, Xing Yong Sua and Pui Yee Lock

Due to economic development, tapered members are commonly applied in steel frames, namely, industrial halls, warehouses, exhibition centres, etc. In the design of cantilever steel…

Abstract

Purpose

Due to economic development, tapered members are commonly applied in steel frames, namely, industrial halls, warehouses, exhibition centres, etc. In the design of cantilever steel beam structures in cities building design, tapering is introduced at the web profile to achieve utmost economy and suit the bending moment distributions. The cross-sectional shape of the beam is varied linearly to the moment gradient to achieve the target of higher efficiency with lower cost.

Design/methodology/approach

The shear deformation pattern and efficiency of the tapered steel section with perforation were investigated using finite element analysis. In addition, I-beam with web opening is studied numerically via LUSAS software for different parameters of tapering ratio, perforation shape and perforation size and perforation layout.

Findings

The highest contributing parameters for the highest shear buckling capacity and efficiency of the section were due to the small opening size and tapering ratio. Whilst the variation of perforation layout and spacing give a major effect on the shear strength and efficiency of the tapered steel section with perforation. Besides that, the highest efficiency model is found when the section is designed with 0.4 D diamond perforation in Layout 3 under a tapering ratio of 0.3. The critical shear buckling load and efficiency is reduced 14.39% and 13.91%, respectively, when perforations are added onto the tapered steel sections.

Originality/value

The tapered steel section with perforation has lower critical shear buckling load and efficiency compared to the tapered section without perforation but obtains a higher critical shear buckling load and efficiency compared to the uniform section without perforation.

Details

World Journal of Engineering, vol. 19 no. 6
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 9 January 2023

Ying Ling Jin, Fatimah De’nan, Kok Keong Choong and Nor Salwani Hashim

Cold-formed steel has been used extensively as secondary elements such as purlins and girts in building frames. Purlin is critical to the structure of the roof because it supports…

Abstract

Purpose

Cold-formed steel has been used extensively as secondary elements such as purlins and girts in building frames. Purlin is critical to the structure of the roof because it supports the weight of the roof deck and aids to make the entire roof structure more rigid. Furthermore, cold-formed steel purlin is a replacement for wood purlin because steel purlins are light weight and more economical. Hence, the purpose of this study to investigate the effect of opening due to torsion behaviour.

Design/methodology/approach

This analysis used cold-formed steel hat purlin with and without openings (WOs) under different opening shape, location and spacing by using finite element LUSAS software.

Findings

The finite element results showed that purlin with openings had higher angle of rotation than section WO, with a percentage difference of not more than 6%. When the opening was located at mid-span, the angle of rotation reduced. Angle of rotation increased when the opening spacing increased. Number of openings also affected the torsional behaviour of the purlin. Five opening shapes, which were circle, diamond, C-hexagon, square and elongated circle, were studied. Among all the shapes, purlin with diamond opening was more resistance to torsion.

Originality/value

The use of cold-formed steel section with web openings (rectangular or circular) is a practical solution when it is required to pass service ducts through the structural member. However, the presence of opening gives minor effect on the structural behaviour of cold-formed steel hat purlin.

Details

World Journal of Engineering, vol. 21 no. 2
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 1 June 2022

Fatimah De'nan, Nor Salwani Hashim and Xing Yong Sua

With the vast advancement of structural steel properties over the recent decades, structural steel has become the dominate material for the construction of bridges, stadiums…

Abstract

Purpose

With the vast advancement of structural steel properties over the recent decades, structural steel has become the dominate material for the construction of bridges, stadiums, factories and high rise buildings. This paper aims to present the study of structural behaviour and efficiency of tapered steel section with elliptical perforation under shear loading conditions.

Design/methodology/approach

The effect of various elliptical perforation configurations such as tapering ratio, perforation size, perforation orientation and perforation layout on the shear behaviour of tapered steel section has been investigated by using finite element method. A total of 112 models are simulated via LUSAS software.

Findings

It has been found that the most efficient model is the tapered steel section with tapering ratio of 0.3 and vertical elliptical perforation of 0.2 times the section depths which are arranged in Layout 3. The most efficient model has a shear efficiency of 1,094.35 kN, which is 4.12% less than the tapered steel section without perforation, but it could achieve a 0.32% of weight reduction.

Originality/value

The smaller tapering ratio and perforation size contributed to the higher shear buckling capacity and efficiency for the elliptical perforated tapered steel section.

Details

World Journal of Engineering, vol. 20 no. 6
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 27 December 2011

El-Hadi Naili, Ali Nadjai, Sanghoon Han, Faris Ali and Sengkwan Choi

This paper describes an experimental and numerical study at elevated temperatures on the behaviour of full scale composite floor cellular steel beams with circular and elongated…

Abstract

This paper describes an experimental and numerical study at elevated temperatures on the behaviour of full scale composite floor cellular steel beams with circular and elongated web openings. A total of three specimens, comprising three different steel geometries and loading conditions were tested at elevated temperatures. Finite element models were established with both material and geometrical non-linearity to compare with the experimental results. This paper also demonstrates the capability of a developed simple design approach in comparison with numerical modelling, experimental tests and existing design software used by the Steel Construction Institute (SCI).

Details

Journal of Structural Fire Engineering, vol. 2 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

1 – 10 of over 14000