Search results

1 – 10 of 68
Open Access
Article
Publication date: 22 September 2021

Ehsan Sorooshnia, Maria Rashidi, Payam Rahnamayiezekavat, Fatemeh Rezaei and Bijan Samali

Optimisation of daylight admission through window is crucial for alleviating glare while maintaining useful daylight levels in order to enhance occupants' health, visual comfort…

2338

Abstract

Purpose

Optimisation of daylight admission through window is crucial for alleviating glare while maintaining useful daylight levels in order to enhance occupants' health, visual comfort and moderating lighting energy consumption. Amongst various solutions, fixed external shade is an affordable solution for housing spaces that need to be sophisticatedly designed, especially during the period of increasing home spaces as working environments. In the humid subtropical region, daylight control plays an important role in indoor comfort, particularly with areas with a high window to wall ratio (WWR). Due to the insufficient amount of such study on non-office spaces in Australia, shading-related standards are not addressed in Australian building codes.

Design/methodology/approach

The chosen methodology for the research is a quantitative data collection and analysis through field measurement and simulation simultaneously. The first step is a multi-objective optimisation of shading elements through a non-dominated sorting genetic algorithm (NSGA-II) on parametric modelling via Rhino3D CAD and simulation engines (DIVA and ClimateStudio). In the second phase, the Pareto front solutions are validated by experimental measurements within a room with a single north-facing window (the most probable for the daytime glare in Sydney) for the seven most common local window configurations.

Findings

Through the simulation of ten genes, 1,560 values and 2.4 × 1,019 of search space, this study found an optimum shade for each local common window layout, resulted in +22% in (UDI) and −16% in views with discomfort glare on average. Moreover, an all-purpose polygonal shade showed an average of 4.6% increase in UDI and a 5.83% decrease in the percentage of views with discomfort glare.

Research limitations/implications

The findings are subject to the room dimensions, window dimensions and layouts, and orientation of windows for selected residential buildings in Sydney.

Originality/value

The study contributes to the development of highly accurate fixed external shading systems with rectangular and tapered-form external shapes. A real-time measurement by luminance-metre sensors and HQ cameras located at six eye levels is conducted to corroborate simulation results of the visual comfort.

Details

Engineering, Construction and Architectural Management, vol. 30 no. 1
Type: Research Article
ISSN: 0969-9988

Keywords

Article
Publication date: 24 May 2013

Tuğba İnan

The purpose of this research is to investigate natural illumination properties of one of the classrooms in the School of Architecture at Izmir Institute of Technology, located in…

1286

Abstract

Purpose

The purpose of this research is to investigate natural illumination properties of one of the classrooms in the School of Architecture at Izmir Institute of Technology, located in Turkey, which is the northern hemisphere.

Design/methodology/approach

In this study, the definitions of the basic terms in daylighting, such as daylight factor, illuminance, glazing ratio, are given first. Then, a luxmeter and a lighting simulation software, Velux, are used in order to calculate variable lighting factors during daytime, at different storeys, at different directions, for the classes. Velux is a proprietary software and it enables natural lighting analysis practically.

Findings

Chosen classrooms are examined regarding their having sufficient natural illumination. The height of windows from the floor is changed, and the resultant effects on natural lighting in the classrooms are determined by using the lighting simulation program, Velux. The study shows that daylight factor and illumination near the window decreases as the height of the window above the floor increases. However, the illumination increases away from the window, giving greater uniformity to the lighting. At the same time, the usable depth of the classroom increases. The tall and narrow windows bring the daylight near themselves.

Social implications

Practical window design decisions can help architects to provide effective and healthy natural lighting for interiors.

Originality/value

Adjustment of the dimensions of the windows is important in order to balance the energy consumption of buildings. This study investigates natural lighting depending on both experimental measurements and simulation software, Velux.

Article
Publication date: 7 December 2022

Fatemeh Mostafavi, Mohammad Tahsildoost, Zahra Sadat Zomorodian and Seyed Shayan Shahrestani

In this study, a novel framework based on deep learning models is presented to assess energy and environmental performance of a given building space layout, facilitating the…

Abstract

Purpose

In this study, a novel framework based on deep learning models is presented to assess energy and environmental performance of a given building space layout, facilitating the decision-making process at the early-stage design.

Design/methodology/approach

A methodology using an image-based deep learning model called pix2pix is proposed to predict the overall daylight, energy and ventilation performance of a given residential building space layout. The proposed methodology is then evaluated by being applied to 300 sample apartment units in Tehran, Iran. Four pix2pix models were trained to predict illuminance, spatial daylight autonomy (sDA), primary energy intensity and ventilation maps. The simulation results were considered ground truth.

Findings

The results showed an average structural similarity index measure (SSIM) of 0.86 and 0.81 for the predicted illuminance and sDA maps, respectively, and an average score of 88% for the predicted primary energy intensity and ventilation representative maps, each of which is outputted within three seconds.

Originality/value

The proposed framework in this study helps upskilling the design professionals involved with the architecture, engineering and construction (AEC) industry through engaging artificial intelligence in human–computer interactions. The specific novelties of this research are: first, evaluating indoor environmental metrics (daylight and ventilation) alongside the energy performance of space layouts using pix2pix model, second, widening the assessment scope to a group of spaces forming an apartment layout at five different floors and third, incorporating the impact of building context on the intended objectives.

Details

Smart and Sustainable Built Environment, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2046-6099

Keywords

Article
Publication date: 4 November 2020

Ayda Montaser Koohsari and Shahin Heidari

The purpose of this paper is to determine the approximate window-to-wall ratio (WWR), window width-to-height ratio (WHR) and sill level for a room in Rasht–Gilan province and to…

Abstract

Purpose

The purpose of this paper is to determine the approximate window-to-wall ratio (WWR), window width-to-height ratio (WHR) and sill level for a room in Rasht–Gilan province and to present an optimal window in each of the WWR ranges providing the minimum energy consumption by integrating artificial lighting and thermal analyses, whilst maintaining internal comfort conditions using dynamic evaluation.

Design/methodology/approach

The process of modelling has four main steps: 1 – defining the building's features and requirements, 2 – validating input weather file data by on-site measurement, 3 – determining input parameters for the lighting and thermal analysis and 4 – clarifying variable parameters and fitness function for the optimization algorithm. Also, the survey study is performed in a daylit office room, in which 30 employees are employed to answer the questions in three different times of a day. In this process, the impact of daylight on their visual comfort is surveyed in 1,350 different illuminance levels which are manually recorded.

Findings

The range of useful daylight illuminance (UDI) values is determined as 200–1,000 lux. The optimum range of WWRs in the case study is 15%–25%. Also, due to the appropriate window height, electric lighting could be decreased by 40%.

Originality/value

Thermal and lighting performance in buildings is the relation of facade characteristics to environmental sustainability. Recent studies focussed on optimizing WWR and window characteristics considering thermal comfort and energy analyses. However, architects need freedom for designing façade and making decisions in their first sketches. Thus a guideline for optimum window conditions in each WWR is required. Also, considering occupants' behaviour in practical buildings, the visual comfort investigation is a gap in WWR optimization.

Details

Built Environment Project and Asset Management, vol. 11 no. 4
Type: Research Article
ISSN: 2044-124X

Keywords

Article
Publication date: 11 June 2018

Francesco De Luca, Raimo Simson, Hendrik Voll and Jarek Kurnitski

Electric lighting accounts for a large share of energy consumption in commercial buildings. Utilization of daylight can significantly help to reduce the need for artificial…

Abstract

Purpose

Electric lighting accounts for a large share of energy consumption in commercial buildings. Utilization of daylight can significantly help to reduce the need for artificial lighting, increase workers productivity, customers’ satisfaction and consequently improve sales. However, excessive use of glazing and absence of lighting controls can contribute greatly to higher energy need for heating and cooling and cause undesired glare effects. Thus, optimizing the size, position and materials of external glazing, with the addition of deflectors and dynamic artificial lighting, can become key aspects in the design of sustainable low energy buildings. The purpose of this paper is to analyze daylight potential and energy performance of a hall-type commercial building, situated in the cold climate of Finland, by utilizing different combinations of skylights, windows and lighting controls.

Design/methodology/approach

The authors have used computer simulations to estimate daylight and energy performance of a single floor commercial building in relation to various combinations of skylights and windows with variable glazing materials, light deflectors and zonal lighting controls.

Findings

The results show that electric light energy saving potential ranges from a negligible 1.9 percent to a significant 58.6 percent in the case of glass skylights and wall windows using multi-zone lighting control. Total delivered energy ranges between increase of 1.5 and 21.2 percent in the cases with single zone lighting control and between decrease of 4.5 percent and increase of 4.5 percent in the cases with multi-zone control. The highest decrease in primary energy consumption was 2.2 percent for single zone and 17.6 percent for multi-zone lighting control. The research underlines the significant potential of electric light energy savings using daylighting strategies that, including the control of direct solar access for glare and internal gains, can be more than 50 percent.

Originality/value

This research combines accurate daylight and energy assessment for commercial hall buildings based in cold climate region with multiple design variations. The novelty of this work is the consideration of interior elements, shelves and deflectors, in the calculations. This is made possible through the combined use of validated simulation platforms for detailed annual daylighting and electric lighting calculation (Radiance and Daysim) and energy analysis (IDA-ICE, Equa Simulation AB). This method allows to obtain a reliable assessment of the potential of using natural light sources in buildings.

Details

Management of Environmental Quality: An International Journal, vol. 29 no. 4
Type: Research Article
ISSN: 1477-7835

Keywords

Article
Publication date: 17 June 2022

Sujatavani Gunasagaran, E. Sean Saw, TamilSalvi Mari, Sucharita Srirangam and Veronica Ng

This study aims to identify the optimal configuration to enhance the environmental conditions of a terrace house courtyard space in a hot and humid climate. The use of the…

Abstract

Purpose

This study aims to identify the optimal configuration to enhance the environmental conditions of a terrace house courtyard space in a hot and humid climate. The use of the courtyard has declined in new housing developments although it is an effective element to bring in light and wind to promote passive ventilation to occupants. To achieve the comfort level, the courtyard needs to be open, but some occupants modify it with enclosures, such as polycarbonate, to increase the useable and shaded area. This affects bringing in daylight but deters the passive ventilation from happening. Thus, this research is important to create a courtyard that brings in daylight and wind as well as shades from the harsh sun of the tropics and to educate the occupants on the role of the courtyard as a passive ventilation system.

Design/methodology/approach

The research method employed is a simulation study. A terrace house with a courtyard design in Penang was chosen as a case study of the baseline model. The courtyard configurations of the case study were evaluated, and 4 settings based on the literature review were established for simulation. The effects of the courtyard configurations were tested through daylight and CFD simulations. Daylight and ventilation requirements from Malaysia Standard were used to evaluate and compare the effectiveness of the proposed settings.

Findings

The results suggested that the semi-enclosed courtyard feature with a shading device could provide the optimal environmental conditions of the courtyard space in a terrace house in a hot-humid climate. This paper will benefit the architectural community in which it is intended to implement courtyard design in modern terrace houses and will also contribute to the discovery of the most suitable courtyard typology in a hot-humid climate.

Research limitations/implications

The study does not include studies on thermal comfort, energy performance, or use behavior of occupants in this courtyard. The study only focuses on the influence of different courtyard configurations in improving the courtyard space's daylight availability and indoor air movement.

Practical implications

The data from this study reveal that alteration of courtyard design needs to suit comfort level that should not alter the functions of the courtyard as a passive design. The simulation method offers data for microclimatic conditions according to the changes in design. This study attempts to design influence on multiple parameters of shading, daylighting and ventilation to optimize the use of tropical climatic conditions.

Social implications

The terrace house with courtyard would create a passive design strategy that would naturally ventilate, provide daylight, and will save on energy usage. The courtyard then with its enhanced comfort for the user will be able to function as a useable space to foster family relationships.

Originality/value

The study on courtyard design using the simulation method mostly have been conducted using a single parameter. This study highlights the analysis and process of identifying the optimal configuration for the architectural feature of a courtyard to provide a comfort level for occupants in hot and humid climates using the simulation method using data from two pieces of software.

Details

Archnet-IJAR: International Journal of Architectural Research, vol. 17 no. 1
Type: Research Article
ISSN: 2631-6862

Keywords

Open Access
Article
Publication date: 16 August 2023

Andrea Zani, Alberto Speroni, Andrea Giovanni Mainini, Michele Zinzi, Luisa Caldas and Tiziana Poli

The paper aims to investigate the comfort-related performances of an innovative solar shading solution based on a new composite patented material that consists of a cement-based…

Abstract

Purpose

The paper aims to investigate the comfort-related performances of an innovative solar shading solution based on a new composite patented material that consists of a cement-based matrix coupled with a stretchable three-dimensional textile. The paper’s aim is, through a performance-based generative design approach, to develop a high-performance static shading system able to guarantee adequate daylit spaces, a connection with the outdoors and a glare-free environment in the view of a holistic and occupant-centric daylight assessment.

Design/methodology/approach

The paper describes the design and simulation process of a complex static shading system for digital manufacturing purposes. Initially, the optical material properties were characterized to calibrate radiance-based simulations. The developed models were then implemented in a multi-objective genetic optimization algorithm to improve the shading geometries, and their performance was assessed and compared with traditional external louvres and overhangs.

Findings

The system developed demonstrates, for a reference office space located in Milan (Italy), the potential of increasing useful daylight illuminance by 35% with a reduced glare of up to 70%–80% while providing better uniformity and connection with the outdoors as a result of a topological optimization of the shape and position of the openings.

Originality/value

The paper presents the innovative nature of a new composite material that, coupled with the proposed performance-based optimization process, enables the fabrication of optimized shading/cladding surfaces with complex geometries whose formability does not require ad hoc formworks, making the process fast and economic.

Details

Construction Innovation , vol. 24 no. 1
Type: Research Article
ISSN: 1471-4175

Keywords

Article
Publication date: 5 June 2007

Peter S. Defoe and Ian Frame

The purpose of this paper is to continue the debate started by M. Pitts and P. Chynoweth in previous issues of Structural Survey and examine some specific areas of concern…

1350

Abstract

Purpose

The purpose of this paper is to continue the debate started by M. Pitts and P. Chynoweth in previous issues of Structural Survey and examine some specific areas of concern regarding the methodologies used for calculating loss of daylight in Rights to Light cases.

Design/methodology/approach

Eight specific areas of concern are identified and each of these is analysed in turn, first to establish, where possible, the origin of the current methodology and then to test this against available current thinking.

Findings

There is a reasonable justification for adopting a value of 500 foot‐candles, although this is not in fact the minimum value. The only justification for using a Uniform Sky appears to be mathematical and another, more accurate, sky model could be used. The Waldram Diagram can legitimately be adjusted to any suitable dimensions provided that the measurements are always taken as a ratio of the chart area. There is no justification for using a work surface height of 850 mm, nor is there any evidence of justification for assuming that 1 foot‐candle of light is adequate for normal use but there is justification in legal terms for ignoring window frames, glazing and internal reflectance.

Practical implications

It can be shown that there is a case for reassessing the methodologies currently accepted by the Courts and therefore that there is scope for further research to establish a new more accurate method.

Originality/value

Whilst many are questioning the validity of daylight calculations in Rights to Light cases, this paper takes some of those questions and establishes whether there is in fact cause for concern.

Details

Structural Survey, vol. 25 no. 2
Type: Research Article
ISSN: 0263-080X

Keywords

Article
Publication date: 1 June 2017

Jian Yao and Rong-Yue Zheng

This study investigated the building energy, glare and daylight performance of overhang using building simulation software Energyplus in order to identify an optimal depth in hot…

Abstract

This study investigated the building energy, glare and daylight performance of overhang using building simulation software Energyplus in order to identify an optimal depth in hot summer and cold winter zone. A typical building with different window-to-wall ratios (WWR) was modeled and different overhang depths were considered. Results showed that the optimal overhang depths are 0.9m (WWR=0.15), 1.16m (WWR=0.3) and 1.62m (WWR=0.57), respectively. The total energy savings from overhang design can be ranging from about 3% to 24% depending on WWR and overhang depth. Moreover, the regression relationship between optimal overhang depth and WWR is given to help identify the best overhang dimension at the design stage. The potential energy saving performance for different WWRs then can be roughly inferred according to a total energy saving chart without building energy simulation. In conclusion, to be applicable in buildings, an overhang depth of 0.6-0.8m is suitable in this region since it has a balance in energy performance and aesthetic appearance.

Details

Open House International, vol. 42 no. 2
Type: Research Article
ISSN: 0168-2601

Keywords

Article
Publication date: 9 July 2021

Mahdi Valitabar, Mohammadjavad Mahdavinejad, Henry Skates and Peiman Pilechiha

The aim of this paper is to present a parametric design method to generate optimum adaptive facades regarding occupants' comfort and building energy criteria. According to the…

Abstract

Purpose

The aim of this paper is to present a parametric design method to generate optimum adaptive facades regarding occupants' comfort and building energy criteria. According to the literature review, the following questions have arisen to address the research gaps: Is it possible to have the outside view throughout the whole year without discomfort glare by utilising adaptive solar facades (ASFs)? How can architects integrate both view quality and quantity into ASF design? What is the impact of dynamic vertical shading systems mounted on south facades on the outside view, occupants' visual comfort and operational energy? How can we evaluate the view quantity through multi-layer shading systems?

Design/methodology/approach

In recent years, there is a surge in demand for fully glazed buildings, motivating both architects and scholars to explore novel ideas for designing adaptive solar facades. Nevertheless, the view performance of such systems has not been fully explored especially when it comes to the effect of dynamic vertical shading systems mounted on south facades. This fact clarifies the need to conduct more research in this field by taking into account the window view and natural light. Consequently, a simulation research is carried out to investigate the impact of a dynamic shading system with three vertical slats used on the south facade of a single office room located in Tehran, on both view quality and quantity, visual comfort and operational energy. The research attempts to reach a balance between the occupant's requirements and building energy criteria through a multi-objective optimisation. The distinctive feature of the proposed method is generating some optimum shading which could only cover the essential parts of the window area. It was detected from the simulation results that the usage of a dynamic vertical shading system with multi slats for south facades compared to common Venetian blinds can firstly, provide four times more view quantity. Secondly, the view quality is significantly improved through enabling occupants to enjoy the sky layer the entire year. Finally, twice more operational energy can be saved while more natural light can enter the indoor environment without glare. The final outcome of this research contributes toward designing high-performance adaptive solar facades.

Findings

This paper proposes a new metric to evaluate the view quantity through a multi-layer shading system. The proposed method makes it clear that the usage of dynamic vertical shading systems with multi-layers mounted on south facades can bring many benefits to both occupants and building energy criteria. The proposed method could (1) provide four times more view quantity; (2) improve view quality by enabling occupants to watch the sky layer throughout the whole year; (3) slash the operational energy by twice; (4) keep the daylight glare probability (DGP) value in the imperceptible range.

Research limitations/implications

The research limitations that should be acknowledged are ignoring the impact of the adjacent building on sunlight reflection, which could cause discomfort glare issues. Another point regarding the limitations of the proposed optimisation method is the impact of vertical shading systems on users' visual interests. A field study ought to be conducted to determine which one could provide the more desirable outside view: a vertical or horizontal the view. Research on the view performance of ASFs, especially their impact on the quality of view, is sorely lacking.

Originality/value

This paper (1) analyses the performance of dynamic vertical shadings on south facades; (2) evaluates outside view through multi-layer shading systems; and (3) integrates both view quality and quantity into designing adaptive solar facades.

Details

Open House International, vol. 46 no. 3
Type: Research Article
ISSN: 0168-2601

Keywords

1 – 10 of 68