Publication date: 25 January 2021

Faezeh Nejati Barzoki, Ghanbar Ali Sheikhzadeh, Morteza Khoshvaght Aliabadi and Ali Akbar Abbasian Arani

The purpose of this paper is to investigate thermohydraulic characteristics of turbulent flow of water (4,000 = Re = 10,000) in a rectangular channel equipped with perforated…

Abstract

Purpose

The purpose of this paper is to investigate thermohydraulic characteristics of turbulent flow of water (4,000 = Re = 10,000) in a rectangular channel equipped with perforated chevron plat-fin (PCPF) with different vortex generators (VGs) shapes.

Design/methodology/approach

First, three general shapes of VGs including rectangular, triangular and half circle, are compared to each other. Then, the various shapes of rectangular VGs, (horizontal, vertical and square) and triangular VGs, (forward, backward and symmetric) are evaluated. To comprehensively evaluate the thermohydraulic performance of the PCPF with various VG shapes, the relationship between the Colburn factor and the friction factor (j/f) is presented, then a performance index (η) is applied using these factors.

Findings

Results show that the enhanced models of the PCPF, which are equipped with VGs, have higher values of j/f ratio and η as compared with the reference model (R). Further, the half-circle VG with the lowest pressure drop values (about 2.4% and 4.9%, averagely as compared with the S and ST vortex generators), shows the highest thermohydraulic performance among the proposed shapes. The maximum of performance index of 1.14 is found for the HC vortex generator at Re = 4,000. It is also found that the square and forward triangular VGs, have the best thermohydraulic performance among the rectangular and triangular VGs respectively and the highest performance index of 1.13 and 1.11 are reported for these VGs.

Originality/value

The thermohydraulic performance of the PCPF with different vortex generators VGs shapes have been investigated.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 31 no. 6
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 8 January 2020

Ali Akbar Abbasian Arani and Hamed Uosofvand

This paper aims to investigate the fluid flow and heat transfer of a laboratory shell and tube heat exchanger that are analyzed using computational fluid dynamic approach by…

Abstract

Purpose

This paper aims to investigate the fluid flow and heat transfer of a laboratory shell and tube heat exchanger that are analyzed using computational fluid dynamic approach by SOLIDWORKS flow simulation (ver. 2015) software.

Design/methodology/approach

In this study, several types of baffle including segmental baffle, butterfly baffle, helical baffle, combined helical-segmental baffle, combined helical-disk baffle and combined helical-butterfly baffle are examined. Two important parameters as the heat transfer and pressure drop are evaluated and analyzed. Based on obtained results, segmental baffle has the highest amount of heat transfer and pressure drop. To assess the integrative performance, performance coefficient defines as “Q/Δp” is used.

Findings

This investigation showed that among the presented baffle types, the heat exchangers equipped with disk baffle has the highest heat transfer. In addition, in the same mass flow rate, the performance coefficient of the shell and tube heat exchanger equipped with helical-butterfly baffle is the highest among the proposed models.

Originality/value

After combined helical-butterfly baffle the butterfly baffle, disk baffle, helical-segmental baffle and helical-disk baffle show their superiority of 35.12, 25, 22 and 12 per cent rather than the common segmental baffle, respectively. Furthermore, except for the combined helical-disk baffle, the other type of combined baffle have better performance compare to the basic configuration (butterfly and segmental baffle).

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 30 no. 8
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 3 April 2017

Rajneesh Kumar, Anoop Kumar and Varun

The purpose of this computational fluid dynamics (CFD)-based study on semicircular rib-roughened equilateral triangular duct is to investigate heat transfer, friction factor and…

Abstract

Purpose

The purpose of this computational fluid dynamics (CFD)-based study on semicircular rib-roughened equilateral triangular duct is to investigate heat transfer, friction factor and thermohydraulic performance parameter. The analysis is carried out by simulating problem in ANSYS (Fluent). The Reynolds number in the study varies from 4,000 to 24,000. Nusselt number is calculated for different Reynolds number using various turbulent models available in ANSYS (Fluent) for a smooth duct and compared the results with the Dittus–Boelter correlation.

Design/methodology/approach

The analysis has been done by solving basic fluid governing equations (continuity, momentum and energy) by using finite volume method (FVM). The semicircular ribs were fabricated on the absorber plate. The constant amount of heat flux is applied on the absorber plate, whereas other two walls are made adiabatic. The semi-implicit method for pressure linked equations (SIMPLE) algorithm is used with pressure–velocity-coupled disretization to estimate the results. The selection of turbulent model has been done on the basis of Nusselt number prediction in the smooth duct.

Findings

The renormalization-group kε model predicts the Nusselt number more accurately as compared to standard kε model, standard kω model, shear stress transport (SST) kω and realizable kε model in the Reynolds number ranges from 4,000 to 24,000 with a ± 5.5% deviation from Dittus–Boelter equation for smooth duct. The maximum thermo-hydraulic performance is observed of the order of 1.7 for arrangement which has a relative roughness height of 0.067 and relative roughness pitch of 7.5 at higher Reynolds Number of 24,000.

Originality/value

Although, many experimental studies are available in the area of rib-roughened ducts, the present study is based on CFD analysis of semicircular rib-roughened equilateral triangular duct and the results are predicted in terms of Nusselt number, friction factor and thermohydraulic performance parameter. Moreover, the predicted result of Nusselt number and friction factor is validated by comparing with Dittus–Boelter correlation and modified Blasius equation, respectively. This advantage made Fluent a powerful tool for analyzing the internal fluid flow through roughened ducts.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 27 no. 4
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 4 January 2013

Mostafa Odabaee, Michel De Paepe, Peter De Jaeger, Christophe T'Joen and Kamel Hooman

The purpose of this paper is to clarify the relationship between dust deposition effects on the thermohydraulic performance of a metal foam heat exchanger.

Abstract

Purpose

The purpose of this paper is to clarify the relationship between dust deposition effects on the thermohydraulic performance of a metal foam heat exchanger.

Design/methodology/approach

The paper uses finite volume approximation to solve the two‐dimensional volume‐averaged form of governing equations through and around a metal foam‐covered tube bundle. Modified porosity, permeability, and form drag coefficient for a dusty foam layer are obtained through the application of a thermal resistance network model.

Findings

The paper provides novel data to predict the fouling effects on the performance of foam‐wrapped tube bundles as air‐cooled heat exchangers. It is observed that depending on the deposited layer thickness, the increased pressure drop and heat transfer deterioration can be very significant.

Originality/value

This paper fulfils an identified need to study fouling effects on thermohydraulic performance of a foam heat exchanger.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 23 no. 1
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 5 April 2021

Ali Akbar Abbasian Arani and Hamed Uosofvand

This paper aims to present a numerical investigation on laboratory-scale segmental baffles shell-and-tube heat exchanger (STHX) having various tube bundles and baffle…

Abstract

Purpose

This paper aims to present a numerical investigation on laboratory-scale segmental baffles shell-and-tube heat exchanger (STHX) having various tube bundles and baffle configuration.

Design/methodology/approach

To discover the higher performance the thermohydraulic behavior of shell-side fluid flow with circular, elliptical and twisted oval tube bundles with segmental and inclined segmental baffled is compared. Shell side turbulent flow and heat transfer are simulated by a finite volume discretization approach using SolidWorks Flow Simulation. To achieve greater configuration performance of this device, the following two approaches is considered: using the inclined baffle with 200 angles of inclination and applying the different tube bundle.

Findings

Different parameters as heat transfer rate, pressure drop (Δp), heat transfer coefficient (h) and heat transfer coefficient to pressure drop ratio (h/Δp) are presented and discussed. Besides, for considering the effect of pressure penalty and heat transfer improvement instantaneously, the efficiency evaluation coefficient (EEC) in the fluid flow and heat transfer based on the power required to provide the real heat transfer augmentation are used.

Originality/value

Obtained results displayed that, at the equal mass flow rate, the twisted oval tubes with segmental baffle decrease the pressure drop 53.6% and 35.64% rather than that the circular and elliptical tubes bundle, respectively. By comparing the (h/Δp) ratio, it can result that the STHX with twisted oval tubes bundle (both segmental and inclined baffle) has better performance than other kinds of the tube bundles. Present results showed that the values of the EEC for all provided models are higher than 1, except for elliptical tube bundles with segmental baffles. The STHX with twisted oval tube bundles and segmental baffle gives the highest EEC value equal to 1.16 in the range of investigated mass flow.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 31 no. 12
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 31 March 2020

Nandkishor Sah and Mohan Jagadeesh Kumar Mandapati

Use of packed beds, enhanced tubes, nano-fluids and artificial ribs are few passive techniques to increase heat transfer in solar air heaters (SAHs). Artificial ribs attached to…

Abstract

Purpose

Use of packed beds, enhanced tubes, nano-fluids and artificial ribs are few passive techniques to increase heat transfer in solar air heaters (SAHs). Artificial ribs attached to the absorber plate of the SAH will enhance the turbulence near the plate. Experimental analyses are conducted to find the thermal performance of SAH with ribs of regular geometries including rectangular, semi-circular and triangular in cross section. This paper aims to present the improvement in thermal performance of SAH with modified-arc.

Design/methodology/approach

Absorber plates are designed with ribs of rectangular, triangular, semi-circular and modified-arc in cross-section using existing data in literature. Physical dimensions of the ribs are designed by adapting procedure from literature. Absorber plates are manufactured with ribs and coated with blackboard paint and fixed to the existing SAH. Experiments are conducted with a variable-speed blower fixed to the inlet section of the SAH, which is used to supply air at different mass flow rates in a range between 0.495 and 0.557 kg/min.

Findings

Efficiency is found to be a strong function of mass flow rate of air through the SAH from the present experimental investigations. It was found that use of modified-arc ribs enhanced the efficiency of SAH by 105.35 per cent compared to SAH with plane absorber plate. Efficiency of SAH with modified-arc ribs is found to be higher by 24.43, 45.61 and 63.21 per cent, respectively, for SAH with semi-circular, rectangular and triangular arc ribs on its absorber plate.

Research limitations/implications

Experiments on SAH are conducted during daytime from 9:00 am to 5:00 pm in open atmospheric conditions. Solar intensity is continuously changing during the experimentation from morning to evening. Calculations are made based on the observations with average values of solar intensity and temperature readings. More accurate values of SAH efficiency can be obtained with constant heat supply to the absorber plate by simulating the experimental setup in indoor conditions. Temperature and flow rate observations could be more accurate with sophisticated instrumentation rather than using simple thermocouples and orifice meters.

Social implications

SAHs are basically used to supply hot air for both rural and industrial applications. These are used for crop drying, preheating of air, removal of moisture from leather, chemicals, etc. Conventionally, formers in India are using open sun drying to remove moisture from agricultural products. In this method, the moisture can be removed up to a level of 20 to 25 per cent. Use of SAH can remove moisture up to below 5 per cent and process is clean without reducing the quality of agricultural products. Enhancing the efficiency of SAHs will surely increase its usage by formers for crop drying.

Originality/value

Use of artificial ribs on absorber plate of SAH is most economical among many of the active and passive techniques. Numerical and experimental investigations are found in literature with regular cross-sectional ribs, including rectangular, triangular and semi-circular. The present work proposed new shape of the ribs named as modified-arc, which was not presented in the literature. Experimental analysis proved that the use of modified-arc makes the SAH more efficient in heat transfer.

Details

World Journal of Engineering, vol. 17 no. 3
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 7 November 2016

Babak Lotfi, Bengt Sunden and Qiu-Wang Wang

The purpose of this paper is to investigate the numerical fluid-structure interaction (FSI) framework for the simulations of mechanical behavior of new vortex generators (VGs) in…

416

Abstract

Purpose

The purpose of this paper is to investigate the numerical fluid-structure interaction (FSI) framework for the simulations of mechanical behavior of new vortex generators (VGs) in smooth wavy fin-and-elliptical tube (SWFET) heat exchanger using the ANSYS MFX Multi-field® solver.

Design/methodology/approach

A three-dimensional FSI approach is proposed in this paper to provide better understanding of the performance of the VG structures in SWFET heat exchangers associated with the alloy material properties and geometric factors. The Reynolds-averaged Navier-Stokes equations with shear stress transport turbulence model are applied for modeling of the turbulent flow in SWFET heat exchanger and the linear elastic Cauchy-Navier model is solved for the structural von Mises stress and elastic strain analysis in the VGs region.

Findings

Parametric studies conducted in the course of this research successfully identified illustrate that the maximum magnitude of von Mises stress and elastic strain occurs at the root of the VGs and depends on geometrical parameters and material types. These results reveal that the titanium alloy VGs shows a slightly higher strength and lower elastic strain compared to the aluminum alloy VGs.

Originality/value

This paper is one of the first in the literature that provides original information mechanical behavior of a SWFET heat exchanger model with new VGs in the field of FSI coupling technique.

Article
Publication date: 29 April 2014

Gongnan Xie, Shian Li, Bengt Sunden and Weihong Zhang

With the development of electronic devices, including the desires of integration, miniaturization, high performance and the output power, cooling requirement of chips have been…

Abstract

Purpose

With the development of electronic devices, including the desires of integration, miniaturization, high performance and the output power, cooling requirement of chips have been increased gradually. Water-cooled minichannel is an effective cooling technology for cooling of heat sinks. The minichannel flow geometry offers large surface area for heat transfer and a high convective heat transfer coefficient with only a moderate pressure loss. The purpose of this paper is to analyze a minichannel heat sink having the bottom size of 35 mm×35 mm numerically. Two kinds of chip arrangement are investigated: diagonal arrangement and parallel arrangement.

Design/methodology/approach

Computational fluid dynamics (CFD) technique is used to investigate the flow and thermal fields in forced convection in a three-dimensional minichannels heat sink with different chip arrangements. The standard k-e turbulence model is applied for the turbulence simulations on the minichannel heat sink.

Findings

The results show that the bottom surface of the heat sink with various chip arrangements will have different temperature distribution and thermal resistance. A suitable chip arrangement will achieve a good cooling performance for electronic devices.

Research limitations/implications

The fluid is incompressible and the thermophysical properties are constant.

Practical implications

New and additional data will be helpful as guidelines in the design of heat sinks to achieve a good thermal performance and a long lifetime in operation.

Originality/value

In real engineering situations, chips are always placed in various manners according to design conditions and constraints. In this case the assumption of uniform heat flux is acceptable for the surfaces of the chips rather than for the entire bottom surface of the heat sink.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 24 no. 4
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 25 March 2024

Emrehan Gürsoy, Hayati Kadir Pazarlioğlu, Mehmet Gürdal, Engin Gedik, Kamil Arslan and Abdullah Dağdeviren

The purpose of this study is to analyse the magnetic field effect on Fe3O4/H2O Ferrofluid flowing in a sudden expansion tube, which has specific behaviour in terms of rheology…

Abstract

Purpose

The purpose of this study is to analyse the magnetic field effect on Fe3O4/H2O Ferrofluid flowing in a sudden expansion tube, which has specific behaviour in terms of rheology, with convex dimple fins. Because the investigation of flow separation is a prominent application in performance, the effect of magnetic field and convex dimple on the thermo-hydraulic performance of sudden expansion tube are examined, in detail.

Design/methodology/approach

During the solution of the boundary conditions of the sudden expansion tube, finite volume method was used. Analyses have been conducted considering the single-phase solution, steady-state, incompressible fluid and no-slip condition of the wall under forced convection conditions. In the analyses, it has been assumed that the flow was developing thermally and has been fully developed hydrodynamically.

Findings

The present study focuses on exploring the influence of the magnetic field, nanofluid concentration and convex dimple fins on the thermo-hydraulic performance of sudden expansion tube. The results indicate that the strength of the magnetic field, nanofluid concentration and convex dimple fins have a positive effect on the convective heat transfer in the system.

Originality/value

The authors conducted numerical studies, determining through a literature search that no one had yet investigated enhancing heat transfer on a sudden expansion tube using combinations of magnetic fields, nanofluids and convex dimple fins. The results of the numerical analyses provide valuable information about the improvement of heat transfer and system performance in electronic device cooling and heat exchangers.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0961-5539

Keywords

Article
Publication date: 22 November 2022

Mani Sekaran Santhanakrishnan, Timothy Tilford and Christopher Bailey

This study aims to provide an insight into the relationship between design parameters and thermal performance of plate fin heat sinks (PFHSs) incorporating longitudinal vortex…

Abstract

Purpose

This study aims to provide an insight into the relationship between design parameters and thermal performance of plate fin heat sinks (PFHSs) incorporating longitudinal vortex generators (VGs) inside a PFHS channel.

Design/methodology/approach

A computational fluid dynamics model of a delta winglet pair VG mounted inside a PFHS geometry is detailed, and the model is validated by comparison with experimental data. The validated model is used to perform a virtual design of experiments study of the heat sink with bottom plate and vertical plate mounted VGs. Data from this study is used to regress a response surface enabling the influence of each of the assessed design variables on thermal performance and flow resistance to be determined.

Findings

The results of this study show that the thermal hydraulic performances of a PFHS with bottom plate mounted VG and vertical plate fin mounted VG are, respectively, 1.12 and 1.17 times higher than the baseline PFHS. Further, the performance variation of the heat sink with VG, relative to delta winglet’s arrangement (common flow up and common flow down), trailing edge gap length and Reynolds number were also evaluated and reported.

Originality/value

For the first time, performance characteristics of delta winglet VGs mounted inside the PFHS are evaluated against different design variables and a polynomial regression model is developed. The developed regression model and computed results can be used to design high performance PFHSs mounted with delta winglet VGs.

Details

International Journal of Numerical Methods for Heat & Fluid Flow, vol. 33 no. 3