Search results

1 – 10 of over 2000
Article
Publication date: 7 March 2016

Sena Terliksiz, Fatma Kalaoğlu and Selin Hanife Eryürük

Sleep is a vital and a basic activity of human life and it is a physiological need for human body. Sleep quality is directly influenced by the comfort conditions of sleep…

Abstract

Purpose

Sleep is a vital and a basic activity of human life and it is a physiological need for human body. Sleep quality is directly influenced by the comfort conditions of sleep environment. The purpose of this paper is to define the role of textile materials utilized as bed fabrics on air and mass transfer from the human body.

Design/methodology/approach

Thermal conductivity, thermal resistance, thickness, water vapour permeability and air permeability properties of fabrics were analyzed and statistically evaluated. Thermal conductivity and resistance measurements were performed in Alambeta test instrument. Water vapour permeability tests were done according to the Rotating Platform method, and air permeability was measured in FX 3300 Textest air permeability tester. Relationships between comfort parameters were statistically evaluated with correlation analysis.

Findings

Comfort is a major concept in the determination of overall life quality as well as sleep quality of a resting person. Therefore academic studies about thermal comfort prediction of sleep environment and bed surface fabrics are of great importance. This study investigates conventional mattress ticking fabrics in terms of comfort parameters and defines the important fabric properties on comfort parameters.

Originality/value

Sleep comfort is a promising area in textile comfort studies with its dynamics different from body thermal comfort during daily life. However, in general comfort studies are about garment materials which are in direct contact with the skin. This study tries to define the comfort status of textile materials which have indirect contact with the human body surface during sleep duration.

Details

International Journal of Clothing Science and Technology, vol. 28 no. 1
Type: Research Article
ISSN: 0955-6222

Keywords

Article
Publication date: 23 August 2018

Zimin Jin, Lei Lei, Haitao Meng, Li Gao and Yuxiu Yan

The purpose of this paper is to measure the thermal and moisture resistance of the knitted upper fabrics with the foot model, which provided basis for designing and producing…

Abstract

Purpose

The purpose of this paper is to measure the thermal and moisture resistance of the knitted upper fabrics with the foot model, which provided basis for designing and producing sports shoes with thermal-moisture comfort.

Design/methodology/approach

In this paper, different yarn materials and fabric stitches were selected as the changing factors. The three kinds of yarn materials and the three kinds of fabric stitches were combined to design and weave eight pieces of knitted upper fabrics. Human sweating was simulated by the thermal-moisture comfort foot model, and then tested the thermal and moisture resistance of eight pieces of fabrics in different parts of the foot. Finally, the relationship between yarn material, fabric stitch, and the thermal and moisture resistance in different parts of the foot was analyzed by data.

Findings

The composition of the yarn material and fabric stitch has certain effect on the thermal-moisture comfort in different sections of the foot. When the yarn material of the four parts of the lateral arch, medial arch, ankle and heel is composed of 31.1tex moisture wicking polyester/33.3tex spandex coated yarn, the yarn material of the instep and toes is composed of 31.1tex ordinary polyester/33.3tex spandex coated yarn, and all parts of fabric stitch choose single-sided loop transfer stitch, the knitted sports shoes have the best thermal-moisture comfort.

Originality/value

The study used the thermal-moisture comfort foot model to simulate the human body metabolism and sweating system. Through the quantitative analyze of the thermal and moisture resistance of knitted upper fabrics to provide basis for the producers to design and product knitted sports shoes with good thermal-moisture comfort.

Details

International Journal of Clothing Science and Technology, vol. 30 no. 5
Type: Research Article
ISSN: 0955-6222

Keywords

Article
Publication date: 22 July 2022

Ender Peker

The purpose of this paper is to explore the role of locally-produced architectural design solutions for the provision of thermal comfort in the vernacular settlements of Mardin…

Abstract

Purpose

The purpose of this paper is to explore the role of locally-produced architectural design solutions for the provision of thermal comfort in the vernacular settlements of Mardin, Turkey.

Design/methodology/approach

With an aim of extracting clues of climate responsive design, the paper develops a socio-technical assessment methodology and presents a comparative inquiry between the vernacular and contemporary built environments of Mardin.

Findings

Findings display that the capacity of vernacular architecture in providing a more climate responsive living environment than contemporary one is in fact correlated with the design of living spaces in harmony with the local climatic conditions as well as how inhabitants traditionally use and behave in designed space.

Originality/value

The paper argues for a need for (re)conceptualization of thermal comfort within and through the production of housing, as well as by taking into account the ways in which end-users interact, adapt and sustain end-users' everyday life in accordance with the local climatic characteristics.

Details

Open House International, vol. 47 no. 3
Type: Research Article
ISSN: 0168-2601

Keywords

Article
Publication date: 28 March 2023

Ibrahim Neya, Daniel Yamegueu, Adamah Messan, Yezouma Coulibaly, Arnaud Louis Sountong-Noma Ouedraogo and Yawovi Mawuénya Xolali Dany Ayite

The stabilization of earthen blocks improves their mechanical strength and avoids adobe construction erosion due to rainwater. However, the stabilization affects the thermal

Abstract

Purpose

The stabilization of earthen blocks improves their mechanical strength and avoids adobe construction erosion due to rainwater. However, the stabilization affects the thermal properties of the earthen blocks, and thus their capacity to provide adequate thermal comfort to occupants. This article examines the influence of cement and geopolymer binders on thermal comfort in compressed earthen buildings in hot and arid climates.

Design/methodology/approach

The test cell is on the building platform in Burkina Faso. The building is made of compressed earth blocks (CEB) consisting of laterite, water and binder. The thermal models of the building were implemented in EnergyPlus v9.0.1 software. Empirical validation is used to check whether the model used for the thermal dynamic simulation can reproduce with accuracy the thermal behavior in a real situation. The adaptive thermal comfort model of ASHRAE 55–2010 was used to assess thermal comfort in long-term hot and dry tropical conditions.

Findings

The results show that the CEB buildings remain hot despite the use of cement or geopolymer binder. Indeed, with both cement and geopolymer binders, on a daily basis, 19 h and 15 h are uncomfortable during, respectively, the hot and cold seasons. An increase of 1% in cement content raises the comfort hours by 9.2 h during the hot season and 11.7 h during the cold season. Hence, the comfort time varies linearly with the cement content in the building material. Moreover, there is no linear relationship between comfort time and geopolymer rate.

Research limitations/implications

Complementary work should also assess the influence of stabilization on building humidity levels. In fact, earthen materials are very sensitive to outdoor humidity and indoor humidity affects thermal comfort even if it is not taken into account in the ASHRAE adaptive thermal comfort model.

Practical implications

The present study will certainly contribute to a better valorization of clay potential in countries with similar climatic conditions.

Social implications

The use of geopolymer binder is a suitable ecological option to replace the cement binder. It is important to mention that nighttime comfort can be increased through passive strategies such as natural ventilation.

Originality/value

Most CEB material stabilization analyses including cement and geopolymer ones were mostly investigated at the laboratory scale and less at the building scale. Also, the influence of the binder rate on the thermal performance of buildings made of cement and geopolymer has not yet been assessed. This paper fills this gap of knowledge by assessing the impact of cement and geopolymer binder rates on the thermal comfort of CEB dwellings.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 4 November 2014

Meshack O. Efeoma and Ola Uduku

The purpose of this paper is to adduce the most appropriate thermal comfort assessment method for determining human thermal comfort and energy efficient temperature control in…

Abstract

Purpose

The purpose of this paper is to adduce the most appropriate thermal comfort assessment method for determining human thermal comfort and energy efficient temperature control in office buildings in tropical West Africa.

Design/methodology/approach

This paper examines the Adaptive Thermal Comfort Standard, from its research evolution to its contemporary use as an environmental design assessment Standard. It compares the adaptive component of ASHRAE Standard 55 and the European CEN/EN 15251. It begins by reviewing relevant literature and then produces a comparative analysis of the two standards, before suggesting the most appropriate Adaptive Thermal Comfort Standard for use in assessing conditions in tropical climate conditions. The suggested Standard was then used to analyse data collected from the author's pilot research into thermal conditions, in five office buildings situated in the city of Enugu, South Eastern Nigeria.

Findings

The paper provides insight as to why the ASHRAE adaptive model is more suitable for thermal comfort assessment of office buildings in the tropical West African climate. This was demonstrated by using the ASHRAE Thermal Comfort Standard to assess comfort conditions from pilot research study data collected on Nigerian office buildings by the author.

Originality/value

The paper compares the adaptive component of ASHRAE Standard 55 with CEN/EN 15251, and their different benefits for use in tropical climates. It suggested the need for further research studies and application of the ASHRAE Adaptive Thermal Comfort Standard in the tropical West African climate.

Article
Publication date: 7 June 2022

Funda Gençer and İlker Karadağ

The study aims to analyze both thermal and wind comfort conditions of a historical mosque's interior and outdoor spaces for the planning of further conservation decisions.

Abstract

Purpose

The study aims to analyze both thermal and wind comfort conditions of a historical mosque's interior and outdoor spaces for the planning of further conservation decisions.

Design/methodology/approach

The method is composed of two steps. First, thermal comfort analyses are conducted via Design-Builder Software. The predicted mean vote (PMV) and predicted percentage of dissatisfied indices were calculated and evaluated using the ASHRAE 55–2010 standard. Thermal comfort conditions are analyzed with the proposed three operations. Second, wind comfort analyses are conducted via computational fluid dynamics (CFD) software. Outdoor thermal comfort conditions are predicted by air temperature, mean radiant temperature, wind speed and relative humidity.

Findings

The (PMV) in the harim was calculated as −1.83 (cool) which corresponds to a predicted percentage of dissatisfaction (PPD) equal to 68.54%. Thermal comfort was provided by daytime and continuous operations; however, intermittent operations did not provide thermal comfort. The wind velocities around the mosque are well below the 5 m/s limit value for standing defined by NEN 8100 wind nuisance standard. Moreover, the limit value of 2.5 m/s for sitting was also satisfied with more than 80% of the semi-enclosed area around the entrance of the mosque. Last comer's hall remains in a slight cold stress range, the rest of the areas have no thermal stress.

Originality/value

This two-stage study creates a base for further improvements to provide comfort conditions in a historical building without interfering with its original features.

Details

Open House International, vol. 47 no. 3
Type: Research Article
ISSN: 0168-2601

Keywords

Open Access
Article
Publication date: 8 March 2021

Ga Yoon Choi, Hwan Sung Kim, Hyungkyoo Kim and Jae Seung Lee

In cities with high density, heat is often trapped between buildings which increases the frequency and intensity of heat events. Researchers have focused on developing strategies…

3168

Abstract

Purpose

In cities with high density, heat is often trapped between buildings which increases the frequency and intensity of heat events. Researchers have focused on developing strategies to mitigate the negative impacts of heat in cities. Adopting green infrastructure and cooling pavements are some of the many ways to promote thermal comfort against heat. The purpose of this study is to improve microclimate conditions and thermal comfort levels in high-density living conditions in Seoul, South Korea.

Design/methodology/approach

This study compares six design alternatives of an apartment complex with different paving and planting systems. It also examines the thermal outcome of the alternatives under normal and extreme heat conditions to suggest strategies to secure acceptable thermal comfort levels for the inhabitants. Each alternative is analyzed using ENVI-met, a software program that simulates microclimate conditions and thermal comfort features based on relationships among buildings, vegetation and pavements.

Findings

The results indicate that grass paving was more effective than stone paving in lowering air temperature and improving thermal comfort at the near-surface level. Coniferous trees were found to be more effective than broadleaf trees in reducing temperature. Thermal comfort levels were most improved when coniferous trees were planted in paired settings.

Practical implications

Landscape elements show promise for the improvement of thermal conditions because it is much easier to redesign landscape elements, such as paving or planting, than to change fixed urban elements like buildings and roads. The results identified the potential of landscape design for improving microclimate and thermal comfort in urban residential complexes.

Originality/value

The results contribute to the literature by examining the effect of tree species and layout on thermal comfort levels, which has been rarely investigated in previous studies.

Details

International Journal of Climate Change Strategies and Management, vol. 13 no. 2
Type: Research Article
ISSN: 1756-8692

Keywords

Article
Publication date: 8 August 2016

Baharuddin Hamzah, Muhammad Taufik Ishak, Syarif Beddu and Mohammad Yoenus Osman

The purpose of this paper is to analyse thermal comfort and the thermal environment in naturally ventilated classrooms. Specifically, the aims of the study were to identify the…

Abstract

Purpose

The purpose of this paper is to analyse thermal comfort and the thermal environment in naturally ventilated classrooms. Specifically, the aims of the study were to identify the thermal environment and thermal comfort of respondents in naturally ventilated university classrooms and compare them with the ASHRAE and Indonesian National Standard (SNI); to check on whether the predicted mean vote (PMV) model is applicable or not for predicting the thermal comfort of occupants in naturally ventilated university classrooms; and to analyse the neutral temperature of occupants in the naturally ventilated university classrooms.

Design/methodology/approach

The study was carried out at the new campus of Faculty of Engineering, Hasanuddin University, Gowa campus. A number of field surveys, which measured thermal environments, namely, air temperature, mean radiant temperature (MRT), relative humidity, and air velocity, were carried out. The personal activity and clothing properties were also recorded. At the same time, respondents were asked to fill a questionnaire to obtain their thermal sensation votes (TSV) and thermal comfort votes (TCV), thermal preference, and thermal acceptance. A total of 118 respondents participated in the study. Before the survey was conducted, a brief explanation was provided to the participants to ensure that they understood the study objectives and also how to fill in the questionnaires.

Findings

The results indicated that the surveyed classrooms had higher thermal environments than those specified in the well-known ASHRAE standard and Indonesian National Standard (SNI). However, this condition did not make respondents feel uncomfortable because a large proportion of respondents voted within the comfort zone (+1, 0, and −1). The predictive mean vote using the PMV model was higher than the respondents’ votes either by TSV or by TCV. There was a huge difference between neutral temperature using operative temperature (To) and air temperature (Ta). This difference may have been because of the small value of MRT recorded in the measured classrooms.

Originality/value

The research shows that the use of the PMV model in predicting thermal comfort in the tropic region might be misleading. This is because PMV mostly overestimates the TSV and TCV of the respondents. People in the tropic region are more tolerant to a higher temperature. On the basis of this finding, there is a need to develop a new thermal comfort model for university classrooms that is particularly optimal for this tropical area.

Details

Structural Survey, vol. 34 no. 4/5
Type: Research Article
ISSN: 0263-080X

Keywords

Article
Publication date: 23 October 2023

Francis O. Uzuegbunam, Fynecountry N. Aja and Eziyi O. Ibem

This research aims to investigate the influence of building design on the thermal comfort of occupants of naturally ventilated hospital (NVH) wards to identify the aspects with…

Abstract

Purpose

This research aims to investigate the influence of building design on the thermal comfort of occupants of naturally ventilated hospital (NVH) wards to identify the aspects with the most significant influence on the thermal comfort of hospital buildings during the hot-dry season in the hot-humid tropics of Southeast Nigeria.

Design/methodology/approach

Field measurements, physical observations and a questionnaire survey of 60 occupants of the wards of the Joint Presbyterian Hospital, Uburu in Ebonyi State, Nigeria were undertaken. The data were analysed using Humphreys' neutral temperature formula, descriptive statistics and multiple regression analysis.

Findings

The results revealed that the neutral temperature for the wards ranges from 26.2 °C to 29.9 °C, the thermal condition in the wards was not comfortable because it failed to meet the ASHRAE Standard 55 as only 65% of the occupants said the thermal condition was acceptable. The number and sizes of windows, building orientation, the presence of high-level windows and higher headroom significantly influenced the occupants' thermal comfort vote.

Practical implications

This research is valuable in estimating comfort temperature and identifying aspects that require attention in enhancing the capacity of NVH wards to effectively meet the thermal comfort needs of occupants in the hot-humid tropics of Southeast Nigeria and other regions that share similar climatic conditions.

Originality/value

To the best of the authors’ knowledge, this is the first study of this nature that provides valuable feedback for building design professionals on the performance of existing hospital buildings in meeting users' thermal comfort needs in the hot-dry season of the hot-humid tropics in Southeast Nigeria.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 29 April 2021

Zul-Atfi Bin Ismail

Improper evaluation and information mismanagement concerning thermal comfort appears to negatively affect occupants' satisfaction and building energy consumption in precast…

Abstract

Purpose

Improper evaluation and information mismanagement concerning thermal comfort appears to negatively affect occupants' satisfaction and building energy consumption in precast concrete (PC) building contexts. Predictive models are particularly problematic in PC building construction projects where natural ventilation levels do not coincide with occupants' thermal comfort and thermal sensation specifications.

Design/methodology/approach

A systematic literature review is undertaken to explore the viability and benefits of a new ICT-based approach for meeting social and environmental objectives.

Findings

Sophisticated thermal comfort system solutions are essential for optimising thermal comfort and saving energy in PC building construction projects.

Originality/value

It is imperative that designers and manufacturers are kept up-to-date with the possibilities and potentials associated with new and nascent technologies so that building projects can meet key sustainability criteria.

Details

Engineering, Construction and Architectural Management, vol. 29 no. 3
Type: Research Article
ISSN: 0969-9988

Keywords

1 – 10 of over 2000