Search results
1 – 10 of 295Feng Liang, Quanyong Xu and Ming Zhou
The purpose of this paper is to propose a quasi-three-dimensional (3D) thermohydrodynamic (THD) model for oil film bearings with non-Newtonian and temperature-viscosity effects…
Abstract
Purpose
The purpose of this paper is to propose a quasi-three-dimensional (3D) thermohydrodynamic (THD) model for oil film bearings with non-Newtonian and temperature-viscosity effects. Its performance factors, including precision and time consumption, are investigated.
Design/methodology/approach
Two-dimensional (2D), 3D and quasi-3D numerical models are built. The thermal and mechanical behaviors of two types of oil film bearings are simulated. All the results are compared with solutions of commercial ANSYS CFX.
Findings
The 2D THD model fails to predict the temperature and pressure field. The results of the quasi-3D THD model coincide well with those of the 3D THD model and CFX at any condition. Compared with the 3D THD model, the quasi-3D THD model can greatly reduce the CPU time consumption, especially at a high rotational speed.
Originality/value
This quasi-3D THD model is proposed in this paper for the first time. Transient mechanical and thermal analyses of high-speed rotor-bearing system are widely conducted using the traditional 3D THD model; however, the process is very time-consuming. The quasi-3D THD model can be an excellent alternative with high precision and fast simulation speed.
Details
Keywords
Sasa Mujovic, Slobodan Djukanovic, Vladan Radulovic and Vladimir A. Katic
Low power devices with switched-mode power supply represent harmonic generating apparatus in widespread use nowadays. The influence of personal computers (PCs), which affect the…
Abstract
Purpose
Low power devices with switched-mode power supply represent harmonic generating apparatus in widespread use nowadays. The influence of personal computers (PCs), which affect the supply voltage, is considered. Harmonic level due to simultaneous PC operation is quantified by the total harmonic distortion of input current (THD I ). The purpose of this paper is to propose a multi-parameter mathematical model for the THD I calculation. The model is convenient for practical engineering application.
Design/methodology/approach
The model is derived using the measured and simulated data. The model coefficients are obtained in the least squares sense.
Findings
Mathematical modeling of THD I is the least expensive and the most convenient solution for engineering application. The models proposed in the literature have many drawbacks, which motivated the authors to develop a more comprehensive solution. Grid stiffness, capacitance of PC power supply unit and PC cluster size represent the major parameters that affect THD I , and as such they are taken into account in the proposed model. The influence of other existing parameters from both line and load side is also discussed and the reasons for their omitting from the model are explained. The model considers various PC configurations within the cluster and it enables the THD I calculation for an arbitrary PC cluster size.
Practical implications
Due to its comprehensiveness and mathematical simplicity, the model is suitable for practical use, and its accuracy is verified through conducted measurements presented in the paper.
Originality/value
The proposed model is more comprehensive than the existing ones, and it overcomes their shortcomings. The THD I calculation is simplified to the level of applying basic arithmetic operations only, without jeopardizing the accuracy. The validity of the model is supported by additional measurements carried out in sites characterized by grid conditions quite different from that used for model developing.
Details
Keywords
A. Pérez‐Foguet, S. Oliete‐Josa and A. Saz‐Carranza
To show the key points of a development education program for engineering studies fitted within the framework of the human development paradigm.
Abstract
Purpose
To show the key points of a development education program for engineering studies fitted within the framework of the human development paradigm.
Design/methodology/approach
The bases of the concept of technology for human development are presented, and the relationship with development education analysed. Special attention is dedicated to the role of case studies in engineering courses. After that, the development education program pushed by the Civil Engineering School of Barcelona and Engineering without Borders is explained, focusing on two major contributions: two optional courses about international aid and development and nine classroom case studies about different technologies used in real co‐operation projects.
Findings
This work provides a conceptual basis for incorporating development education into engineering studies, a general overview of different activities promoted in Spanish technical universities and practical information about optional courses and classroom case studies.
Research limitations/implications
The proposal is based on the experience in Spanish engineering curricula (mostly in five‐year degrees). Some of the topics covered by the courses and the case studies can be better adapted at postgraduate level in three‐ or four‐year degrees.
Practical implications
It is shown that development education can be incorporated into engineering studies through different specific non‐expensive activities.
Originality/value
This work presents and puts in context the development education activities pushed coordinately between a non‐governmental organization and an engineering school. Thus, it can be of major interest for both teachers and workers of the international development field.
Details
Keywords
The purpose of this paper is to provide a T autotransformer based 12-pulse rectifier with passive harmonic reduction in more electric aircraft applications. The T autotransformer…
Abstract
Purpose
The purpose of this paper is to provide a T autotransformer based 12-pulse rectifier with passive harmonic reduction in more electric aircraft applications. The T autotransformer uses only two main windings which result in volume, space, size, weight and cost savings. Also, the proposed unconventional inter-phase transformer (UIPT) with a lower kVA rating (about 2.6% of the load power) compared to the conventional inter-phase transformer results in a more harmonic reduction.
Design/methodology/approach
To increase rating and reduce the cost and complexity of a multi-pulse rectifier, it is well known that the pulse number must be increased. In some practical cases, a 12-pulse rectifier (12PR) is suggested as a good solution considering its simple structure and low weight. But the 12PR cannot technically meet the standards of harmonic distortion requirements for some industrial applications, and therefore, they must be used with output filters. In this paper, a 12PR is suggested, which consists of a T autotransformer 12PR and a passive harmonic reduction (PHR) based on the UIPT at direct current (DC) link.
Findings
To show the advantage of this new combination over other solutions, simulation results are used, and then, a prototype is implemented to evaluate and verify the simulation results. The simulation and experimental test results show that the input current total harmonic distortion (THD) of the suggested 12PR with a PHR based on UIPT is less than 5%, which meets the IEEE 519 requirements. Also, it is shown that in comparison with other solutions, it is cost effective, and at the same time, its power factor is near unity, and its rating is 29.92% of the load rating. Therefore, it is obvious that the proposed rectifier is a practical solution for more electric aircrafts.
Originality/value
The contributions of this paper are summarized as follows. The suggested design uses a retrofit T autotransformer, which meets all technical constraints, and in comparison, with other options, has less rating, weight, volume and cost. In the suggested rectifier, a PHR based on UIPT at its dc link of 12PR is used, which has good technical capabilities and lower ratings. In the PHR based on UIPT, an IPT is used, which has an additional secondary winding and four diodes. This solution leads to a reduction in input current THD and conduction losses of diodes. In full load conditions, the input line current THD and power factor are 4% and 0.99, respectively. The THD is less than 5%, which satisfies IEEE-519 and DO-160G requirements.
Details
Keywords
Rajini V., Jassem M., Nagarajan V.S., Sreeya Galla N.V. Sai and Jeyapradha Rb
Industrial drives require appropriate control systems for reliable and efficient performance. With synchronous reluctance machines (SynRMs) slowly replacing the most commonly used…
Abstract
Purpose
Industrial drives require appropriate control systems for reliable and efficient performance. With synchronous reluctance machines (SynRMs) slowly replacing the most commonly used induction, switched reluctance and permanent magnet machines, it is essential that the drive and its control be properly selected for enhanced performance. But the major drawback of synchronous reluctance motor is the presence of high torque ripple as its design is characterized by large number of variables. The solutions to reduce torque ripple include design modifications, choice of proper power electronic inverter and PWM strategy. But little has been explored about the power electronic inverters suited for synchronous reluctance motor drive to minimize torque ripple inherently by obtaining a more sinusoidal voltage. The purpose of this paper is to elaborate on the potential multilevel inverter topologies applicable to SynRM drives used in solar pumping applications.
Design/methodology/approach
The most significant field-oriented control using maximum torque per ampere algorithm for maximizing the torque production is used for the control of SynRM. Simulation results carried out using Matlab/Simulink are presented to justify the choice of inverter and its control technique for SynRM.
Findings
The five-level inverter drive gives lesser core or iron losses in the SynRMin comparison to the three- and two-level inverters due to lower Id current ripple. The five-level inverter reduces the torque ripple of the SynRM significantly in comparison to the three- and two-level inverter fed SynRM drives. The phase disposition-PWM control method used for the inverter shows the least total harmonic distortion (THD) levels in output voltage compared with the other level shifted PWM techniques.
Originality/value
Among the available topologies, a fitting topology is proposed for use for the SynRM drive to have minimal THD, minimal current and torque ripple. Additionally, this paper presents various modulation techniques available for the selected drive system and reports on a suitable technique based on minimal THD of output voltage and hence minimal torque ripple.
Details
Keywords
Gorazd Štumberger, Bojan Štumberger, David Stojan, Željko Plantić, Klemen Deželak, Matjaž Čemažar and Drago Dolinar
Many authors reported the decrease of performances when electric machines and electromagnetic devices were supplied by pulse width modulated (PWM) voltages. However, these…
Abstract
Purpose
Many authors reported the decrease of performances when electric machines and electromagnetic devices were supplied by pulse width modulated (PWM) voltages. However, these statements are rarely supported by measurements performed under fair conditions. The aim of this paper is to compare the performances of a single‐phase transformer and a three‐phase permanent magnet synchronous motor (PMSM) supplied by sinusoidal and PWM voltages and to find a way to evaluate the decrease of performances when PWM voltages are applied.
Design/methodology/approach
In order to perform a fair comparison between performances of the tested objects supplied by sinusoidal and PWM voltages, an experimental system was built. It contains a single‐phase and a three‐phase linear rectifier for supply with sinusoidal voltages and an H‐bridge inverter and a three‐phase inverter for supply with PWM voltages. The tests and measurements were performed on a single‐phase transformer and three‐phase PMSM, where different constant loads and different modulation frequencies were used. The test conditions were identical for the supply by sinusoidal and PWM voltages. The measured data, used for the evaluation of performances, were the input and output power and the time behaviours of currents and voltages together with their THDs.
Findings
The results presented in the paper clearly show that the efficiency of the singe‐phase transformer and three‐phase PMSM decreases with the increasing level of voltage THD. To properly determine the THD of PWM voltage, the sampling frequencies above 1 MHz and special equipment are normally required. However, if the modulation frequency is not too high, also the current THD, which can be easily determined, can be used to evaluate the decrease of efficiency in the case of supply by PWM voltages.
Originality/value
The results presented in the paper clearly show that the efficiency of the singe‐phase transformer and three‐phase PMSM decreases with the increasing level of voltage THD.
Details
Keywords
Chinnaraj Gnanavel and Kumarasamy Vanchinathan
These implementations not only generate excessive voltage levels to enhance the quality of power but also include a detailed investigating of the various modulation methods and…
Abstract
Purpose
These implementations not only generate excessive voltage levels to enhance the quality of power but also include a detailed investigating of the various modulation methods and control schemes for multilevel inverter (MLI) topologies. Reduced harmonic modulation technology is used to produce 11-level output voltage with the production of renewable energy applications. The simulation is done in the MATLAB/Simulink for 11-level symmetric MLI and is correlated with the conventional inverter design.
Design/methodology/approach
This paper is focused on investigating the different types of asymmetric, symmetric and hybrid topologies and control methods used for the modular multilevel inverter (MMI) operation. Classical MLI configurations are affected by performance issues such as poor power quality, uneconomic structure and low efficiency.
Findings
The variations in both carrier and reference signals and their performance are analyzed for the proposed inverter topologies. The simulation result compares unipolar and bipolar pulse-width modulation (PWM) techniques with total harmonic distortion (THD) results. The solar-fed 11-level MMI is controlled using various modulation strategies, which are connected to marine emergency lighting loads. Various modulation techniques are used to control the solar-fed 11-level MMI, which is connected to marine emergency lighting loads. The entire hardware system is controlled by using SPARTAN 3A field programmable gate array (FPGA) board and the least harmonics are obtained by improving the power quality.
Originality/value
The simulation result compares unipolar and bipolar PWM techniques with THD results. Various modulation techniques are used to control the solar-fed 11-level MMI, which is connected to marine emergency lighting loads. The entire hardware system is controlled by a SPARTAN 3A field programmable gate array (FPGA) board, and the power quality is improved to achieve the lowest harmonics possible.
Details
Keywords
Cheng Xiong, Bo Xu, Yulong Jiang, Xiangyu Lu and Zhenqian Chen
This study aims to investigate the thermohydrodynamic (THD) and thermoelastohydrodynamic (TEHD) performance of an air-lubricated thrust bearing under different slip conditions…
Abstract
Purpose
This study aims to investigate the thermohydrodynamic (THD) and thermoelastohydrodynamic (TEHD) performance of an air-lubricated thrust bearing under different slip conditions, especially the slip length effect.
Design/methodology/approach
In this study, a new modified boundary slip model was established to investigate thrust bearing performance. The THD and TEHD bearing characteristic distribution was analyzed with fluid–thermal–structure interaction approach. The effect of the slip length on the bearing performance was studied using various bearing structure parameters.
Findings
The increased slip length changed the classical feature distribution of the film pressure and temperature. The sacrifice of the bearing load capacity effectively compensated for the aerodynamic thermal effect and friction torque under the slip condition. The TEHD model has a lower film pressure and load capacity than the THD model. However, it also has lower film temperature, lower friction torque and smaller Knudsen number (Kn).
Originality/value
The bearing THD and TEHD performances of the modified boundary slip model were compared with those of a traditional no-slip bearing. The results help to guide the selection of the bearing surface materials and processing technology of rotor and foil, so as to fully control the degree of slip and make use of it.
Details
Keywords
For direct torque controlled induction motor drives, an effective solution to eliminate harmonics is the use of multipulse alternating current (AC)-direct current (DC) converters…
Abstract
Purpose
For direct torque controlled induction motor drives, an effective solution to eliminate harmonics is the use of multipulse alternating current (AC)-direct current (DC) converters. Many researchers have used different configurations based on 24- and 30-pulse rectifications for improved power quality. However, the total harmonic distortion (THD) of AC mains current with these topology is more than 4 per cent when operating at a light load. For mitigating the THD problems observed in the input currents, Abdollahi propose 40-, 72- and 88-pulse AC-DC converters, while the power quality enhancement was the main concern. It is known that by increasing the number of pulses further results in reduction in current harmonics, but this is accompanied by an increase in cost and complexity. In this context, the purpose of this paper is to design a new delta/hexagon transformer based 36-pulse AC-DC converter for harmonic reduction without increasing the cost and complexity.
Design/methodology/approach
The proposed converter consists of two paralleled 18-pulse AC-DC converters involving a nine-phase shifted uncontrolled diode bridges with an interphase transformer circuit.
Findings
In this paper, the proposed scheme is simulated by matrix laboratory (MATLAB)/SIMULINK considering different loading scenarios. The simulation results show that the proposed scheme improves the power quality indices and satisfies the The Institute of Electrical and Electronics Engineers (IEEE)-519 requirements at the point of common coupling. Also, a laboratory prototype is implemented using the proposed design, and the experimental results confirm the simulation results under different loading conditions.
Originality/value
The proposed solution is a tradeoff among the pulse number, the transformer platform, the complexity of the scheme and the cost. The proposed scheme has an optimized configuration in this regard.
Details
Keywords
Kannan Chandrasekaran, Nalin Kant Mohanty and Selvarasu Ranganathan
Multilevel inverter (MLI) is a prevailing sensible alternative to two-level inverters that offer a high-quality output voltage waveform, wherein the multiple input direct current…
Abstract
Purpose
Multilevel inverter (MLI) is a prevailing sensible alternative to two-level inverters that offer a high-quality output voltage waveform, wherein the multiple input direct current (DC) levels are established by using isolated DC sources, batteries and renewable energy sources. The purpose of this paper is to develop MLI to offer lower total harmonic distortion (THD), higher output voltage levels and reduced switching components for high power applications.
Design/methodology/approach
In this paper, a new tapped sources stack succored modified HX bridge MLI (TSSSMHXBMLI) topology is proposed which includes two modules, such as tapped sources stack (TSS) and modified HX bridge inverter, which perform their function in a single stage. Also, this paper outlines the formulaic implementation of the multicarrier/sub-harmonic pulse width modulation (MCPWM/SHPWM) in a Xilinx Spartan3E-500 field programmable gate array (FPGA) is suitable for the developed MLI.
Findings
The feasibility of the suggested topology is well proved by both simulation and experiment results.
Practical implications
This paper examines a new topology of TSSSMHXBMLI with a view to minimize total count of switching components against basic MLI topologies. The operating sequence of the suggested TSSSMHXBMLI topology is verified with the simulation study followed by an experimental investigation.
Originality/value
The simulation and experimental results of suggested MLI topology reveals to obtain lower THD, higher output voltage levels and reduced switching components for high power applications.
Details