Search results

1 – 10 of 41
Article
Publication date: 15 May 2018

Osama A.B. Hassan and Christopher Johansson

This paper aims to compare glued laminated timber and steel beams with respect to structural design, manufacturing and assembly costs and the amount of greenhouse gas emissions.

1350

Abstract

Purpose

This paper aims to compare glued laminated timber and steel beams with respect to structural design, manufacturing and assembly costs and the amount of greenhouse gas emissions.

Design/methodology/approach

This paper presents structural design requirements in conformance with EN 1993: Eurocode 5 and Eurocode 3. With the help of these standards, expressions are derived to evaluate the design criteria of the beams. Based on the results of life-cycle analysis, the economic properties and environmental impact of the two types of beam are investigated. In this paper, the effect of beam span on the design values, costs and carbon dioxide emissions is analysed when investigating aspects of the structural design, economy and environmental impact. Different cross-sections are chosen for this purpose.

Findings

The study shows that the glued laminated (abbreviated as “glulam”) beams have a smaller tendency to lateral torsional buckling than the steel beams, and that they can be cheaper. From an environmental point of view, glulam beams are the more environmentally friendly option of the two beam materials. Furthermore, glulam beams may have a direct positive effect on the environment, considering the carbon storage capacity of the wood. The disadvantage of glued wood is that larger dimensions are sometimes required.

Research limitations/implications

Wind load and the effect of second-order effects have not been considered when analysing the static design. Only straight beams have been studied. Furthermore, the dynamic design of the beams has not been investigated, and the bearing pressure capacity of the supports has not been analyzed. We have investigated timber beams with a rectangular cross-section, and steel beams of rolled I-sections, known as “HEA profiles”. The cost analysis is based mainly on the manufacturing and assembly costs prevalent on the Swedish market. The only environmental impact investigated has been the emission of greenhouse gases. The design calculations are based on the European standards Eurocode 5 and Eurocode 3.

Practical implications

To achieve sustainability in construction engineering, it is important to study the environmental and economic consequences of the building elements. By combining these two effects with the technical design of buildings made of steel and/or timber, the concept of sustainable development can be achieved in the long run.

Social implications

The study concerns sustainability of building structures, which is an important of the sustainable development of the society.

Originality/value

The paper contains new information and will be useful to researchers and civil engineers.

Details

Journal of Engineering, Design and Technology, vol. 16 no. 3
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 18 April 2018

Hitoshi Kinjo, Yusuke Katakura, Takeo Hirashima, Shuitsu Yusa and Kiyoshi Saito

This paper aims to discuss the fire performance of glulam timber beams based on their deflection behavior and load-bearing period, which were obtained from load-bearing fire tests…

Abstract

Purpose

This paper aims to discuss the fire performance of glulam timber beams based on their deflection behavior and load-bearing period, which were obtained from load-bearing fire tests under constant load conditions.

Design/methodology/approach

In this report, the fire performance, primarily deflection behavior and load-bearing period of glued laminated (glulam) timber beams will be discussed from the standpoint of load-bearing fire tests conducted during the cooling phase under constant load conditions. Then, based on the charring depth and the per section temperature transformation obtained from loading test results, the load-bearing capacity of the glulam timber beams will be discussed using the effective section method and the strength reduction factor, which will be calculated in accordance with the European standards for the design of timber structures (Eurocode 5).

Findings

In the cooling phase, the charring rate is decreases. However, as the temperature in the cross section rises, the deflection is increases. The failure mode was bending failure because of tensile failure of the lamina at the bottom of the beam. Moreover, a gap caused by shear failure in a growth ring in the beam cross-section in the vicinity of the centroid axis was observed. Shear failure was observed up until 1 to 3 h before end of heating. The calculated shear strength far exceeded the test results. Shear strength for elevated temperature of glued laminated timber is likely to decrease than the shear strength in Eurocode 5.

Originality/value

Unlike other elements, a characteristic problem of timber elements is that their load-bearing capacity decreases as they are consumed in a fire, and their bearing capacities may continue to degrade even after the fuel in the room has been exhausted. Therefore, the structural fire performance of timber elements should be clarified during not only the heating phase but also the subsequent cooling phase. However, there are few reports on the load-bearing capacity of timber elements that take the cooling phase after a fire into consideration.

Details

Journal of Structural Fire Engineering, vol. 9 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 17 July 2017

Hirokazu Ohashi, Shinya Igarashi and Tsutomu Nagaoka

As forestry contributes to the reduction of greenhouse gases by CO2 fixation, in recent years, use of wood in buildings has attracted all over the world more attention. However…

Abstract

Purpose

As forestry contributes to the reduction of greenhouse gases by CO2 fixation, in recent years, use of wood in buildings has attracted all over the world more attention. However, construction of large wood structures is almost inexistent within urban areas in Japan. This is due to the Japanese law on fire protection of wood buildings in cities, which is considered very strict with severe requirements. This paper aims to present a research work relative to the development of one-hour fire-resistant wood structural elements for buildings in cities. The developed elements are composed of three layers made of laminated timber.

Design/methodology/approach

These wood structural elements, made of glued laminated timber with self-charring-stop, have sufficient fire resistance during and after a fire and comply with the strict Japanese standard for wood structural elements, which stipulates that such elements have to withstand the whole dead-load of concerned buildings after fire. To comply with such requirements, new elements of glued laminated timber with self-charring-stop layer were developed, and their performance was confirmed. Several fire-resistant tests conducted on columns, beams, column-beam joints, connections between beams and walls and beams with holes were carried out.

Findings

All tests proved that the elements have sufficient fire resistance. No damage was found out at the load-bearing part of the elements after testing. As the developed elements have two layers protecting the load-bearing part, the temperature in the load-bearing part could be retained below 260°C (carbonization temperature) and provide the elements with a sufficient fire resistance for 1 h.

Practical implications

These wood structural elements have already been applied in six projects, where large-size wooden buildings were constructed in urban areas in Japan.

Originality/value

The proposed structural elements use a novel technique. Every wooden element is composed of three layers made of glued laminated timber. The elements have a typical performance of self-charring-stop after fire without need for water of firefighters. More technologies related to these elements, including column-beam joints and beams with holes and effect of crack, were also developed to design and construct safe wooden buildings.

Details

Journal of Structural Fire Engineering, vol. 9 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 12 December 2016

H. Kinjo, T. Hirashima, S. Yusa, T. Horio and T. Matsumoto

Based on heating tests and load-bearing fire tests, this paper aims to discuss the charring rate, the temperature distribution in the section and the load-bearing capacity of…

Abstract

Purpose

Based on heating tests and load-bearing fire tests, this paper aims to discuss the charring rate, the temperature distribution in the section and the load-bearing capacity of structural glued laminated timber beams not only during the heating phase during a 1-h standard fire in accordance with ISO 834-1 but also during the cooling phase.

Design/methodology/approach

Heating tests were carried out to confirm the charring rate and the temperature distribution in the cross-section of the beams. Loading tests under fire conditions were carried out to obtain the load-deformation behavior (i.e. the stiffness, maximum load and ductility) of the beam.

Findings

The temperature at the centroid reached approximately 30°C after 1 h and then increased gradually until reaching 110-200°C after 4 h, during the cooling phase. The maximum load of the specimen exposed to a 1-h standard fire was reduced to approximately 30 per cent of that of the specimen at ambient temperature. The maximum load of the specimen exposed to a 1-h standard fire and 3 h of natural cooling in the furnace was reduced to approximately 14 per cent. In case of taking into consideration of the strength reduction at elevated temperature, the reduction ratio of the calculated bending resistance agreed with that of the test results during not only heating phase but also cooling phase.

Originality/value

The results of this study state that it is possible to study on strength reduction in cooling phase for end of heating, timber structural which has not been clarified. It is believed that it is possible to appropriately evaluate the fire performance, including the cooling phase of the timber structural.

Details

Journal of Structural Fire Engineering, vol. 7 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 30 September 2019

Adam Roman Petrycki and Osama (Sam) Salem

In fire condition, the time to failure of a timber connection is mainly reliant on the wood charring rate, the strength of the residual wood section, and the limiting temperature…

208

Abstract

Purpose

In fire condition, the time to failure of a timber connection is mainly reliant on the wood charring rate, the strength of the residual wood section, and the limiting temperature of the steel connectors involved in the connection. The purpose of this study is to experimentally investigate the effects of loaded bolt end distance, number of bolt rows, and the existence of perpendicular-to-wood grain reinforcement on the structural fire behavior of semi-rigid glued-laminated timber (glulam) beam-to-column connections that used steel bolts and concealed steel plate connectors.

Design/methodology/approach

In total, 16 beam-to-column connections, which were fabricated in wood-steel-wood bolted connection configurations, in eight large-scale sub-frame test assemblies were exposed to elevated temperatures that followed CAN/ULC-S101 standard time-temperature curve, while being subjected to monotonic loading. The beam-to-column connections of four of the eight test assemblies were reinforced perpendicular to the wood grain using self-tapping screws (STS). Fire tests were terminated upon achieving the failure criterion, which predominantly was dependent on the connection’s maximum allowed rotation.

Findings

Experimental results revealed that increasing the number of bolt rows from two to three, each of two bolts, increased the connection’s time to failure by a greater time increment than that achieved by increasing the bolt end distance from four- to five-times the bolt diameter. Also, the use of STS reinforcement increased the connection’s time to failure by greater time increments than those achieved by increasing the number of bolt rows or the bolt end distance.

Originality/value

The invaluable experimental data obtained from this study can be effectively used to provide insight and better understanding on how mass-timber glulam bolted connections can behave in fire condition. This can also help in further improving the existing design guidelines for mass-timber structures. Currently, beam-to-column wood connections are designed mainly as axially loaded connections with no guidelines available for determining the fire resistance of timber connections exerting any degree of moment-resisting capability.

Details

Journal of Structural Fire Engineering, vol. 14 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 20 January 2022

Milad Shabanian and Nicole Leo Braxtan

The purpose of this paper is to investigate the thermo-mechanical behavior of intermediate-size glued-laminated beam-to-girder assemblies connected with T-shaped slotted-in steel…

Abstract

Purpose

The purpose of this paper is to investigate the thermo-mechanical behavior of intermediate-size glued-laminated beam-to-girder assemblies connected with T-shaped slotted-in steel doweled connections at ambient temperature (AT), after and during non-standard fire exposure.

Design/methodology/approach

AT tests were performed using a universal testing machine (UTM) to evaluate the load-carrying capacity and failure modes of the assembly at room temperature. Post-fire-performance (PFP) tests were conducted to study the impact of 30-min and 60-min partial exposure to a non-standard fire on the residual strength of the assemblies. The assemblies were subject to fire in a custom-designed frame, then cooled and loaded to failure in the UTM. A fire-performance test was conducted to investigate the fire-resistance during non-standard fire exposure by simultaneously applying fire and mechanical load with the custom frame.

Findings

At AT, embedment failure of the dowels followed by brittle splitting failure were found to be the dominant failure modes in the beams. In the PFP tests, embedment failure and plastic bending of the dowels were the only observed failure modes. The residual strength of the assembly was reduced by 23.7% after 30-min and 47.8% after 60-min of fire exposure. Ductile embedment failure of the timber in contact with the dowels was the only failure mode observed during the fire-performance test, with the maximum rate of displacement at 57 min into the fire.

Originality/value

Data are presented for full-contact (no gap) connections in Glulam assemblies. PFP results are first to be published.

Article
Publication date: 5 January 2022

Oluwamuyiwa Okunrounmu, Osama (Sam) Salem and George Hadjisophocleous

The fire resistance of timber structures is heavily dependent on the fire behaviour of the connections between its structural elements. The experimental study presented in this…

Abstract

Purpose

The fire resistance of timber structures is heavily dependent on the fire behaviour of the connections between its structural elements. The experimental study presented in this paper aimed to investigate the fire performance of glued-laminated timber beam connections reinforced perpendicular-to-wood grain with self-tapping screws (STS).

Design/methodology/approach

Two full-size fire experiments were conducted on glulam beam-end connections loaded in flexure bending. Two connection configurations, each utilizing four steel bolts arranged in two different patterns, were reinforced perpendicular to wood grain using STS. The bolt heads and nuts and the steel plate top and bottom edges were fire protected using wood plugs and strips, respectively. Each connection configuration was loaded to 100% of the ultimate design load of the weakest unreinforced configuration. The test assemblies were exposed to elevated temperatures that followed the CAN/ULC-S101 standard fire time–temperature curve.

Findings

The experimental results show that the influence of the STS was significant as it prevented the occurrence of wood splitting and row shear-out and as a result, increased the fire resistance time of the connections. The time to failure of both connection configurations exceeded the minimum fire resistance rating specified as 45 min for combustible construction in applicable building codes.

Originality/value

The experimental data show the effectiveness of a simple fire protection system (i.e. wood plugs and strips) along with the utilization of STS on the rotational behaviour, charring rate, fire resistance time and failure mode of the proposed hybrid mass timber beam-end connection configurations.

Details

Journal of Structural Fire Engineering, vol. 13 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 19 October 2021

Tong Wang, Jing Di and Hongliang Zuo

In view of the defects of glued wood beams, a new composite member – reconstituted bamboo board reinforced glued wood beams is proposed to improve the bearing capacity of glued

Abstract

Purpose

In view of the defects of glued wood beams, a new composite member – reconstituted bamboo board reinforced glued wood beams is proposed to improve the bearing capacity of glued wood beams.

Design/methodology/approach

The bending test studied the ordinary glulam beams and the reinforced glulam beams with different layer numbers and different layer thicknesses by comparing with six kinds of glulam beams strengthened with bamboo scrimber and one kind of ordinary glulam beams and used the method of third-point stepwise loading on the glulam beams strengthened with bamboo scrimber.

Findings

The bamboo scrimber improved the bending behavior of the ordinary glulam beams. The 10 mm bamboo scrimber layer can meet the requirements of the maximum ultimate bending capacity and minimize the defects. So 10 mm bamboo scrimber layer was the optimal thickness. During the loading process, the strain change of the normal section of the reconstituted bamboo board reinforced glued wood beam basically conforms to the plane section assumption.

Originality/value

The bending rigidities of the glulam beams strengthened with bamboo scrimber increased up to 28.25%, 8.53% and 76.67%, and the ultimate bending capacity increased from 83.44% to 99.34% with the increase of the bamboo scrimber plate layers (the replacement rate). The ultimate bending capacities and the bending rigidities of the glulam beams strengthened with bamboo scrimber increased to 52.32%∼60.18% and 90.07%∼99.34% with the changing of the bamboo scrimber thicknesses from 7.1 mm to 25 mm.

Details

International Journal of Structural Integrity, vol. 13 no. 1
Type: Research Article
ISSN: 1757-9864

Keywords

Open Access
Article
Publication date: 7 December 2022

Milad Shabanian and Nicole Leo Braxtan

Thermomechanical behavior of intermediate-size beam-to-wall assemblies including Glulam-beams connected to cross-laminated timber (CLT) walls with T-shape steel doweled…

Abstract

Purpose

Thermomechanical behavior of intermediate-size beam-to-wall assemblies including Glulam-beams connected to cross-laminated timber (CLT) walls with T-shape steel doweled connections was investigated at ambient temperature (AT) and after and during non-standard fire exposure.

Design/methodology/approach

Three AT tests were conducted to evaluate the load-carrying capacity and failure modes of the assembly at room temperature. Two post-fire performance (PFP) tests were performed to study the impact of 30-min (PFP30) and 60-min (PFP60) partial exposure to a non-standard fire on the residual strength of the assemblies. The assemblies were exposed to fire in a custom-designed frame, then cooled and loaded to failure. A fire performance (FP) test was conducted to study the fire resistance (FR) during non-standard fire exposure by simultaneously applying fire and a mechanical load equal to 65% of the AT load carrying capacity.

Findings

At AT, embedment failure of the dowels followed by splitting failure at the Glulam-beam and tensile failure of the epoxy between the layers of CLT-walls were the dominant failure modes. In both PFP tests, the plastic bending of the dowels was the only observed failure mode. The residual strength of the assembly was reduced 14% after 30 min and 37% after 60 min of fire exposure. During the FP test, embedment failure of timber in contact with the dowels was the only major failure mode, with the maximum rate of displacement at 51 min into the fire exposure.

Originality/value

This is the first time that the thermomechanical performance of such an assembly with a full-contact connection is presented.

Details

Journal of Structural Fire Engineering, vol. 14 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 2 May 2017

Rafael Castro-Triguero, Enrique Garcia-Macias, Erick Saavedra Flores, M.I. Friswell and Rafael Gallego

The purpose of this paper is to capture the actual structural behavior of the longest timber footbridge in Spain by means of a multi-scale model updating approach in conjunction…

Abstract

Purpose

The purpose of this paper is to capture the actual structural behavior of the longest timber footbridge in Spain by means of a multi-scale model updating approach in conjunction with ambient vibration tests.

Design/methodology/approach

In a first stage, a numerical pre-test analysis of the full bridge is performed, using standard beam-type finite elements with isotropic material properties. This approach offers a first structural model in which optimal sensor placement (OSP) methodologies are applied to improve the system identification process. In particular, the effective independence (EFI) method is used to determine the optimal locations of a set of sensors. Ambient vibration tests are conducted to determine experimentally the modal characteristics of the structure. The identified modal parameters are compared with those values obtained from this preliminary model. To improve the accuracy of the numerical predictions, the material response is modeled by means of a homogenization-based multi-scale computational approach. In a second stage, the structure is modeled by means of three-dimensional solid elements with the above material definition, capturing realistically the full orthotropic mechanical properties of wood. A genetic algorithm (GA) technique is adopted to calibrate the micromechanical parameters which are either not well-known or susceptible to considerable variations when measured experimentally.

Findings

An overall good agreement is found between the results of the updated numerical simulations and the corresponding experimental measurements. The longitudinal and transverse Young's moduli, sliding and rolling shear moduli, density and natural frequencies are computed by the present approach. The obtained results reveal the potential predictive capabilities of the present GA/multi-scale/experimental approach to capture accurately the actual behavior of complex materials and structures.

Originality/value

The uniqueness and importance of this structure leads to an intensive study of its structural behavior. Ambient vibration tests are carried out under environmental excitation. Extraction of modal parameters is obtained from output-only experimental data. The EFI methodology is applied for the OSP on a large-scale structure. Information coming from several length scales, from sub-micrometer dimensions to macroscopic scales, is included in the material definition. The strong differences found between the stiffness along the longitudinal and transverse directions of wood lumbers are incorporated in the structural model. A multi-scale model updating approach is carried out by means of a GA technique to calibrate the micromechanical parameters which are either not well-known or susceptible to considerable variations when measured experimentally.

Details

Engineering Computations, vol. 34 no. 3
Type: Research Article
ISSN: 0264-4401

Keywords

1 – 10 of 41