Search results

1 – 10 of over 5000
Article
Publication date: 7 January 2019

Chun-Lin Lu and Meng-Kao Yeh

Analysis of the thermal effects during the packaging process or in the actual operating environment is necessary to develop small monolithic integrated sensing chips with…

Abstract

Purpose

Analysis of the thermal effects during the packaging process or in the actual operating environment is necessary to develop small monolithic integrated sensing chips with heterogeneous integration. The use of multiple layers and various materials in monolithic integrated sensing chips addresses the coefficient of thermal expansion (CTE) mismatch issue. The purpose of this study is to focus on the residual stress analysis of the shielding electrode, which is a metal film that prevents pull-in of proof-mass during anodic bonding in microelectromechanical system (MEMS) chips with pressure sensors embedded in an accelerometer.

Design/methodology/approach

The finite element model of the chip was built by the commercial software ANSYS, and the residual stress was evaluated during the die attachment process for the shielding electrode. Various shielding electrode materials and a proposed design with a keep-out zone to reduce the residual stress are discussed, with a focus on the relationship between the geometric parameters of the chip and the residual stress for copper shielding electrodes of different thicknesses.

Findings

The results of the finite element analysis showed that the use of polysilicon as a shielding electrode in the proposed design generated the lowest residual stress because of its low CTE. The maximum stresses in both of in-plane and out-of-plane directions in the finite element model were reduced by keep-out zone design for the proposed design of the copper shielding electrode, and had 11 times reduction in out-of-plane direction especially, according to the nonlinear analysis as the stress concentration point in the shielding electrode moved. Moreover, the design with a thinner shielding electrode, thinner glass substrate and higher CTE of the glass substrate also lowered the maximum von Mises stress. On the other hand, the stress level during the operating temperature, without considering residual stress, overestimated up to five times in the proposed design.

Originality/value

In this study, valuable suggestions are proposed for the design of chips with pressure sensors embedded in accelerometers.

Details

Microelectronics International, vol. 36 no. 1
Type: Research Article
ISSN: 1356-5362

Keywords

Article
Publication date: 22 October 2019

Ravishanker Baliga, Sharat K. Rao, Raghuvir Pai, Satish B. Shenoy, Atmananda K. Hegde, Shubham Swaroop and Abhijeet Shetkar

The purpose of this paper is to investigate by means of finite element analysis (FEA), the effect of polyethylene insert thickness and implant material, under axial loading…

Abstract

Purpose

The purpose of this paper is to investigate by means of finite element analysis (FEA), the effect of polyethylene insert thickness and implant material, under axial loading following TKA.

Design/methodology/approach

The 3D geometric model of bone was processed using the CT scan data by MIMICS (3matic Inc.), package. Implant components were 3D scanned and subsequently 3D modeled using ANSYS Spaceclaim and meshed in Hypermesh (Altair Hyperworks). The assembled, meshed bone-implant model was then input to ABAQUS for FE simulations, considering axial loading.

Findings

Polyethylene insert thickness was found to have very little or no significance (p>0.05) on the mechanical performance, namely, stress, strain and stress shielding of bone-implant system. Implant material was found to have a very significant effect (p<0.05) on the performance parameters and greatly reduced the high stress zones up to 60 percent on the tibial flange region and periprosthetic region of tibia.

Originality/value

Very few FEA studies have been done considering a full bone with heterogeneous material properties, to save computational time. Moreover, four different polyethylene insert thickness with a metal-backed and all-poly tibial tray was considered as the variables affecting the bone-implant system response, under static axial loading. The authors believe that considering a full bone shall lead to more precise outcomes, in terms of the response of bone-implant system, namely, stress, strains and stress shielding in the periprosthetic region, to loading.

Details

Multidiscipline Modeling in Materials and Structures, vol. 16 no. 2
Type: Research Article
ISSN: 1573-6105

Keywords

Article
Publication date: 9 April 2018

Sunil Bhat and S. Narayanan

Behavior of mode I crack tip in fiber metal laminate (FML) differs from that in homogeneous or plain specimen made of metal used in the laminate due to the load transfer effect in…

60

Abstract

Purpose

Behavior of mode I crack tip in fiber metal laminate (FML) differs from that in homogeneous or plain specimen made of metal used in the laminate due to the load transfer effect in the laminate caused by property mismatch between dissimilar material layers. The purpose of this paper is to present a finite element investigation on the characteristics of crack tip in monotonically loaded and residually stressed FML.

Design/methodology/approach

Crack tip characteristics are assessed by: the sizes of various zones that form at the tip; and crack tip energy release rates. The same are found by modeling two types of Glare laminates under monotonic tension with different crack orientations in SSY regime – Type I and Type II. Residual stresses are externally introduced in the models. Delaminations are modeled by cohesive elements. Crack tip zone sizes are measured from finite element solutions. Values of J integrals are computed over cyclic paths near the crack tips. Identically cracked and loaded plain aluminum alloy specimens are also modeled for comparison.

Findings

The sizes of crack tip zones in Glare laminates are found to be different than those in plain specimens. Process zone is observed to form at crack tip in Type I laminate whereas it does not develop in Type II laminate, the reverse being true in plain specimens. Values of J integrals near crack tips are also found to deviate from those in plain specimens, higher in Type I laminate due to crack tip stress amplification and lower in Type II laminate due to stress reduction. Crack orientation decides the amplification or shielding effect in the laminate.

Research limitations/implications

There is scope for validating the numerical results reported in the paper by theoretical models.

Practical implications

The method to quantify crack tip shielding and amplification is presented that shall be useful in checking the structural integrity/safety of the laminate during actual service conditions.

Originality/value

Shielding and amplification effects are explicitly described and illustrated in the paper. Suitability of using J integrals over paths crossing non-homogeneous and property mismatched material layers is tested. Use of cohesive zone method that is readily applicable in finite element procedures and is relatively simple, fast and reasonably accurate is also demonstrated.

Details

International Journal of Structural Integrity, vol. 9 no. 2
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 4 September 2019

Intan Najwa Humaira Mohamed Haneef, Norhashimah Shaffiar, Yose Fachmi Buys and Abdul Malek Abd. Hamid

The internal fixation plate of bone fractures by using polylactic acid (PLA) has attracted the attention of many researchers, as it is biodegradable and biocompatible to the human…

Abstract

Purpose

The internal fixation plate of bone fractures by using polylactic acid (PLA) has attracted the attention of many researchers, as it is biodegradable and biocompatible to the human body. However, its brittleness has led to implant fracture. On the contrary, polypropylene carbonate (PPC), which is also biodegradable and biocompatible, has an excellent elongation at break. The purpose of this paper is to compare the PLA fixation plate with the new fixation plate made up of PLA/PPC blends by using finite element analysis (FEA).

Design/methodology/approach

The mandible bone from CT data set and fixation plate was designed by using the MIMICS, Amira and Solidworks softwares. Abaqus software was used for FEA of PLA/PPC fixation plate applied on the fractured mandible bone. A model of mandibular bone with a fracture in the body was subjected to incisor load. The analysis was run to determine the von Mises stress, elongation of the fixation plate and the displacement of the fractured gap of PLA/PPC blends fixation plate.

Findings

The von Mises stress predicted that all the blend compositions were safe to be used as a fixation plate since the stress values were less than the yield strength. In addition, the stress value of the fixation plate was gradually decreased up to 20 percent when the amount of PPC increased to 30 percent. This indicates that the stress shielding effect was successfully reduced. The elongation of the fixation plate was gradually increased from 11.54 to 12.55 µm as the amount of PPC in the blends increased from 0 to 30 percent, thereby illustrating that the flexibility of the fixation plate was improved by the addition of PPC. Finally, the measured displacement of the fractured gap for all compositions of PLA/PPC blends fixation plate is less than 150 µm, which proves the likely success of fracture fixation by using the PLA/PPC blends.

Research limitations/implications

An optimum solution of PLA/PPC blends and another new material such as compatibilizer need to be introduced in the blends in order to improve the performance of PLA/PPC blends as a new material for a fixation plate. Besides, by using the same method of producing PLA/PPC blends, longer durations for in vitro degradation of PLA/PPC blends are essential to further understand the degradation behavior of the blends applied in the human body. Finally, it is also important to further test the mechanical strength of PLA/PPC blends during the degradation period to know the current strength of the implant in the healing process of the bone.

Practical implications

PLA fixation plate and screw can commercially be used in CMF surgery since they reduce cost because of the elimination of secondary surgery to remove the fixation plate and screw after the healing process.

Social implications

It is hoped that the advantages of this research will ensure the market of PLA product to continue expanding in medical application.

Originality/value

This study is one of the alternative ways for the biomedical researchers to improve the elongation break of PLA. Currently, many researchers focus on polymeric materials such as PLA, poly(glycolic) acid and polydioxanone blends, which were extensively being used in CMF surgery. However, the work on PLA/PPC blends to be used as one of the materials for the CMF fixation plate is very limited, if any. PPC, the proposed material for this research, will improve the mechanical performance of PLA fixation plate and screw to become more sustainable and flexible when applied on human mandible bone.

Details

International Journal of Structural Integrity, vol. 10 no. 5
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 23 August 2013

Deepayan Gope, Prakash Chandra Gope and Aruna Thakur

This paper aims to deal with the study of interaction between multiple cracks in an aluminum alloy under static loading. Self-similar as well as non-self-similar crack growth has…

Abstract

Purpose

This paper aims to deal with the study of interaction between multiple cracks in an aluminum alloy under static loading. Self-similar as well as non-self-similar crack growth has been observed which depends on the relative crack positions defined by crack offset distance and crack tip distance. On the basis of experimental observations, the conditions for crack coalescence, crack shielding, crack interaction, crack initiation, etc. are discussed with respect to crack position parameters. Considering crack tip distance, crack offset distance, crack size and crack inclination with loading axis as input parameter and crack initiation direction as output parameter, an artificial neural network (ANN) model is developed. The model results were then compared with the experimental results. It was observed that the model predicts the crack initiation direction under monotonic loading within a scatter band of ±0.5°.

Design/methodology/approach

The study is based on the experimental observations. Growth studies are made from the growth initiation from two cracks in a rectangular aluminium plate under static loading. The present study is focused on the influence of crack position defined by crack offset distance and crack tip distance on growth direction. In addition to this, ANN has been used to predict crack growth direction in multiple crack geometry under static loading. The predicted results have been compared with the experimental data.

Findings

The influence of the interaction between multiple cracks on crack extension angle greatly depends on the relative position of cracks defined by crack tip distance S, crack offset distance H and crack inclinations with respect to loading direction. The intensity of the crack interaction can be described according to degree of crack extension angle and relative crack position factors. It is also observed that the progress of the outer and inner crack tip direction is different which mainly depends on the relative crack position.

Research limitations/implications

It is limited to static loading only. Under fatigue loading findings may differ.

Practical implications

It is important to investigate the growth behaviour under multiple cracks and also to know the effect of crack statistics on the growth behaviour to estimate the component life. The study also focused on the development of a high quality predictive method.

Originality/value

The results show trends that vary with crack geometry condition and the ANN and empirical solution provides a possible solution to assess crack initiation angle under multiple crack geometry.

Details

International Journal of Structural Integrity, vol. 4 no. 3
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 13 May 2020

Ruslizam Daud, Xu Wenzhao, Ishak Ibrahim, Nur Saifullah Kamarrudin, Khairul Salleh Basaruddin, Fauziah Mat and Rohaizar Ismail

Miniplate shapes determine the fixation stability to promote best healing and osseointegration process of mandibular fracture. In clinical treatment, the common method used two…

Abstract

Purpose

Miniplate shapes determine the fixation stability to promote best healing and osseointegration process of mandibular fracture. In clinical treatment, the common method used two straight-type miniplate or I-shape miniplate; sometimes this method is not stable enough or limited by the fracture geometry and caused high risk of failure due to screw loosening. This paper aims to investigate a new type of miniplate called V-shape miniplate design as an alternative to the standard straight plate based on total displacement, von Mises stress, stress transfer parameter (STP) and strain energy density transfer parameters (SEDPTs) for two types of bite force condition, which is cutting and chewing condition.

Design/methodology/approach

The 3D fixation models were constructed and the finite element (FE) simulation is based on the two-bite force load that ranges from 50 to 700 N based on cutting and chewing bite force condition using ANSYS Workbench 19.2.

Findings

In result comparison, the maximum loading of the V-shape miniplate can reduce deformation by 5.9%, reduce stress by 0.58% reduce strain by 8.1% in cutting condition while reducing deformation by 6.43%, reduce stress by 15.25%, reduce strain by 10.1% in chewing condition. To assess the stress transfer behavior of miniplates fixations to the mandibular bone, the STP and SEDPT were evaluated at the normal cortex screw and the locking head screw. In the simulation, the locking head screw is vertical to the bone structure while the cortex screw is 95 degrees to the bone structure, as a result, the STP value for locking head screw is 1.0073 while in cortex screw is 0.7408.

Research limitations/implications

Meanwhile, the SEDPT value for locking head screw is 2.7574 and 1.8412 for cortex screw.

Practical implications

Clinically, V-shape miniplate has shown factual data that can be used for prototyping. STP and SEDTP values provide evidence of how fixation stability is better than I-shape miniplate.

Originality/value

In conclusion, the newly designed V-shape miniplate has overall better stability than the standard I-shape miniplate, and the locking head screw has the STP value closer to 1 than the standard cortex screw; it means the locking screw is better in reducing the stress shielding.

Details

International Journal of Structural Integrity, vol. 11 no. 4
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 7 November 2016

Pawel Zygmunt Witczak and Michal Swiatkowski

The purpose of this paper is to calculate forces created by the magnetic leakage field, which are directly applied to tank walls via magnetic shield.

Abstract

Purpose

The purpose of this paper is to calculate forces created by the magnetic leakage field, which are directly applied to tank walls via magnetic shield.

Design/methodology/approach

Electromagnetic and mechanical calculations use 3D finite element technology, both applied to materials having constant orthotropic properties. The magnetic solver uses harmonic excitation; the analysis of mechanical deflection is carried out in static conditions. Two types of forces are considered: magnetostatic surface forces and magnetostriction volumetric ones. In measurements, the laser scanning vibrometer was applied.

Findings

Electromagnetic calculations must use an FE mesh much denser than that for typical power loss analysis. The magnetic orthotropy of the shield material does not create any important effects and it may be omitted. Magnetostriction forces are similar in value to magnetostatic ones, but their influence on the shield deformation is negligible.

Research limitations/implications

The results obtained for the analysis of the displacement of elements of the tank wall are exemplary – they show the difference between magnetostatic and magnetostriction excitation only. The analysis of the vibration of the transformer tank must include the presence of the oil inside the tank.

Originality/value

The asymmetrical placement of magnetic shields against the transformer core creates the visible differences in the magnitudes of magnetostatic forces applied to particular shields. Therefore, the design of magnetic shielding should also include the vibrational point of view.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, vol. 35 no. 6
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 27 September 2021

Kashif Ishfaq, Mudassar Rehman, Ahmed Raza Khan and Yanen Wang

Human aging is becoming a common issue these days as it results in orthopaedic-related issues such as joints disorderness, bone-fracture. People with age = 60 years suffer more…

Abstract

Purpose

Human aging is becoming a common issue these days as it results in orthopaedic-related issues such as joints disorderness, bone-fracture. People with age = 60 years suffer more from these aforesaid issues. It is expected that these issues in human beings will ultimately reach 2.1 billion by 2050 worldwide. Furthermore, the increase in traffic accidents in young people throughout the world has significantly emerged the need for artificial implants. Their implantation can act as a substitute for fractured bones or disordered joints. Therefore, this study aims to focus on electron beam melted titanium (Ti)-based orthopaedic implants along with their recent trends in the field.

Design/methodology/approach

The main contents of this work include the basic theme and background of the metal-based additive manufacturing, different implant materials specifically Ti alloys and their classification based on crystallographic transus temperature (including α, metastable β, β and α + β phases), details of electron beam melting (EBM) concerning its process physics, various control variables and performance characteristics of EBMed Ti alloys in orthopaedic and orthodontic implants, applications of EBMed Ti alloys in various load-bearing implants, different challenges associated with the EBMed Ti-based implants along with their possible solutions. Recent trends and shortfalls have also been described at the end.

Findings

EBM is getting significant attention in medical implants because of its minor issues as compared to conventional fabrication practices such as Ti casting and possesses a significant research potential to fabricate various medical implants. The elastic modulus and strength of EBMed ß Ti-alloys such as 24Nb-4Zr-8Sn and Ti-33Nb-4Sn are superior compared to conventional Ti for orthopaedic implants. Beta Ti alloys processed by EBM have near bone elastic modulus (approximately 35–50 GPa) along with improved tribo-mechanical performance involving mechanical strength, wear and corrosion resistance, along with biocompatibility for implants.

Originality/value

Advances in EBM have opened the gateway Ti alloys in the biomedical field explicitly ß-alloys because of their unique biocompatibility, bioactivity along with improved tribo-mechanical performance. Less significant work is available on the EBM of Ti alloys in orthopaedic and orthodontic implants. This study is directed solely on the EBM of medical Ti alloys in medical sectors to explore their different aspects for future research opportunities.

Article
Publication date: 1 October 2018

Kangjie Cheng, Yunfeng Liu, Chunyan Yao, Wenquan Zhao and Xu Xu

The purpose of this study is to obtain a titanium mandibular implant that possesses a personalized external shape for appearance recovery, a supporting structure for physiological…

450

Abstract

Purpose

The purpose of this study is to obtain a titanium mandibular implant that possesses a personalized external shape for appearance recovery, a supporting structure for physiological loading and numerous micro-pores for accelerating osseointegration.

Design/methodology/approach

A three-dimensional intact mandibular model of a beagle dog was created from cone-beam computerized tomography scans. A segment of the lower jaw bone was resected and replaced by a personalized implant with comprehensive structures including a customized external shape, supporting structures and micro-pores, which were designed by topology optimization. Then with FEM analysis, the stress, displacement distribution and compliance of the designed implant were compared with the non-optimized model. The weight of the optimized implant that was fabricated by SLM with titanium alloy powder was measured and contrasted with the predicted non-optimized model for evaluating the viability of the design.

Findings

The FEM results showed the peaks of von Mises stress and displacement on the optimized implant were much lower than those of the implant without optimization. With topology optimization, the compliance of the implant decreased significantly by 53.3 per cent, and a weight reduction of 37.2 per cent could be noticed.

Originality/value

A design strategy for personalized implant, with comprehensive structures and SLM as the fabrication method, has been developed and validated by taking a canine mandible as the case study. With comprehensive structures, the implant presented good biomechanical behaviors thanks to the most appropriate supporting structures obtained by optimal design. The topological optimal design combined with SLM printing proved to be an effective method for the design and fabrication of personalized implant with complex structures.

Details

Rapid Prototyping Journal, vol. 25 no. 2
Type: Research Article
ISSN: 1355-2546

Keywords

Article
Publication date: 20 October 2014

Palash Kumar Maji, Amit Jyoti Banerjee, Partha Sarathi Banerjee and Sankar Karmakar

The purpose of this paper was development of patient-specific femoral prosthesis using rapid prototyping (RP), a part of additive manufacturing (AM) technology, and comparison of…

1232

Abstract

Purpose

The purpose of this paper was development of patient-specific femoral prosthesis using rapid prototyping (RP), a part of additive manufacturing (AM) technology, and comparison of its merits or demerits over CNC machining route.

Design/methodology/approach

The customized femoral prosthesis was developed through computed tomography (CT)-3D CAD-RP-rapid tooling (RT)-investment casting (IC) route using a stereolithography apparatus (SLA-250) RP machine. A similar prosthesis was also developed through conventional CT-CAD-CAM-CNC, using RP models to check the fit before machining. The dimensional accuracy, surface finish, cost and time involvement were compared between these two routes.

Findings

In both the routes, RP had an important role in checking the fit. Through the conventional machining route, higher-dimensional accuracies and surface finish were achieved. On the contrary, RP route involved lesser time and cost, with rougher surface finish on the prosthesis surface and less internal shrinkage porosity. The rougher surface finish of the prosthesis is favourable for bone ingrowths after implantation and porosity reduce the effective stiffness of the prosthesis, leading to reduced stress shielding effect after implantation.

Research limitations/implications

As there is no AM machine for direct fabrication of metallic component like laser engineered net shaping and electron beam melting in our Institute, the metallic prosthesis was developed through RP-RT-IC route using the SLA-250 machine.

Practical implications

The patient-specific prosthesis always provides better fit and favourable stress distribution, leading to longer life of the prosthesis. The described RP route can be followed to develop the customized prosthesis at lower price within the shortest time.

Originality/value

The described methodology of customized prosthesis development through the AM route and its advantages are applicable for development of any metallic prostheses.

Details

Rapid Prototyping Journal, vol. 20 no. 6
Type: Research Article
ISSN: 1355-2546

Keywords

1 – 10 of over 5000