Search results

1 – 10 of 96
Article
Publication date: 17 October 2018

Stephen Loh Tangwe and Michael Simon

The purpose of this paper is fourfold: to experimentally determine the standby thermal energy losses in various hot water cylinders in both scenarios, without isotherm blanket…

Abstract

Purpose

The purpose of this paper is fourfold: to experimentally determine the standby thermal energy losses in various hot water cylinders in both scenarios, without isotherm blanket installation and with isotherm blanket installation; to analytically evaluate the performance of either the geyser, split- or integrated-type ASHP water heaters based on the number of heating up cycles and total electrical energy consumptions over a 24-h period without isotherm blankets and with isotherm blankets installed; to demonstrate the impact of the electrical energy factors of the split- and integrated-type ASHP water heaters under both the scenarios (without and with the isotherm blankets installed); and to use statistical tests (one way ANOVA and multiple comparison procedure tests) to verify whether any significant difference in the standby thermal energy losses occurred for each of the heating devices under both the scenarios.

Design/methodology/approach

The methodology was divided into monitoring of the performance of the electrical energy consumptions and ambient conditions of the hot water heating technologies without isotherm blanket installation and with isotherm blanket installation.

Findings

The results reveal that the average standby thermal energy loss of the geyser without the installation of an isotherm blanket was 2.5 kWh. And this standby loss can be reduced to over 18.5 per cent by just installing a 40-mm thick isotherm blanket on the tank. The statistical tests show a significant mean difference in the group electrical energy consumed to compensate for the standby losses under both scenarios. In contrast, the average standby thermal energy losses for the split- and integrated-type ASHP water heaters were 1.33 kWh and 0.92 kWh, respectively. There was a reduction of 15.5 per cent and 3.5 per cent in the electrical energy consumed in compensating for standby losses for both the split and integrated types, respectively, but there was no significant mean difference in the standby losses under both scenarios for the two systems. Again, without any loss of generality, the electrical energy factor of both the ASHP water heaters decreased upon installation of the isotherm blanks.

Research limitations/implications

The experiments were conducted only for a 150-L geyser and 150-L split- and integrated-type ASHP water heaters. The category of the different types of ASHP water heaters was limited to one because of the cost implication.

Practical implications

The experiments were not conducted with various hot water storage tanks installed in different positions (roof, inside or outside of a building wall, etc.) so that actual real-life observations could be obtained. The challenges of easy disassembling and deployment of systems and DAS to different positions were also a real concern.

Social implications

The findings can help homeowners and ESCO in deciding whether to install isotherm blankets on storage tanks of ASHP water heaters on the basis of the impact of standby losses and its potential viability.

Originality/value

The experimental design and methodology are the first of its kind to be conducted in South Africa. The results and interpretation were obtained from original data collected from a set of experiments conducted. The findings also show that the installation of isotherm blanket on an electric geyser can result in a significant mean reduction in the standby losses. In contrast, an installation of the isotherm blankets on the storage tanks of ASHP water heaters can reduce the standby losses, but there exists no significant mean difference.

Details

Journal of Engineering, Design and Technology, vol. 16 no. 5
Type: Research Article
ISSN: 1726-0531

Keywords

Book part
Publication date: 5 June 2023

Mehdi Ebrahimi, David S-K. Ting and Rupp Carriveau

Sustainable development calls for a larger share of intermittent renewable energy. To mitigate this intermittency, Compressed Air Energy Storage (CAES) technology was introduced…

Abstract

Sustainable development calls for a larger share of intermittent renewable energy. To mitigate this intermittency, Compressed Air Energy Storage (CAES) technology was introduced. This technology can be made more sustainable by recovering the heat of the compression phase and reusing it during the discharge phase, resulting in an adiabatic CAES without the need for burning of fossil fuels. The key process parameters of CAES are temperature, pressure ratios, and the mass flow rates of air and thermal fluids. The variation in these parameters during the charge and discharge phases significantly influences the performance of CAES plants. In this chapter, the transient thermodynamic behavior of the system under various operating conditions is analyzed and the impact of heat recovery on the discharge phase energy efficiency, power generation, and CO2 emissions is studied. Simulations are carried out over the air pressure range from 2,500 to 7,000 kPa for a 65 MW system over a five-hour discharge duration. It is also assumed that the heat loss in the air storage and the hot thermal fluid tank is insignificant and standby duration does not impact the status of the system. This result shows that the system exergy and the generated power are more sensitive to pressure change at higher pressures. This work also reveals that every 10°C increase on the temperature of the stored air can lead to a 0.83% improvement in the energy efficiency. The result of the transient thermodynamic model is used to estimate the reduction in CO2 emissions in CAES systems. According to the obtained result, a 65 MW ACAES plant can reduce about 17,794 tons of CO2 emission per year compared to a traditional CAES system with the same capacity.

Article
Publication date: 28 March 2019

Vahid Amir, Shahram Jadid and Mehdi Ehsan

Microgrids are inclined to use renewable energy resources within the availability limits. In conventional studies, energy interchange among microgrids was not considered because…

Abstract

Purpose

Microgrids are inclined to use renewable energy resources within the availability limits. In conventional studies, energy interchange among microgrids was not considered because of one-directional power flows. Hence, this paper aims to study the optimal day-ahead energy scheduling of a centralized networked multi-carrier microgrid (NMCMG). The energy scheduling faces new challenges by inclusion of responsive loads, integration of renewable sources (wind and solar) and interaction of multi-carrier microgrids (MCMGs).

Design/methodology/approach

The optimization model is formulated as a mixed integer nonlinear programing and is solved using GAMS software. Numerical simulations are performed on a system with three MCMGs, including combined heat and power, photovoltaic arrays, wind turbines and energy storages to fulfill the required electrical and thermal load demands. In the proposed system, the MCMGs are in grid-connected mode to exchange power when required.

Findings

The proposed model is capable of minimizing the system costs by using a novel demand side management model and integrating the multiple-energy infrastructure, as well as handling the energy management of the network. Furthermore, the novel demand side management model gives more accurate optimal results. The operational performance and total cost of the NMCMG in simultaneous operation of multiple carriers has been effectively improved.

Originality/value

Introduction and modeling of the multiple energy demands within the MCMG. A novel time- and incentive-based demand side management, characterized by shifting techniques, is applied to reshape the load curve, as well as for preventing the excessive use of energy in peak hours. This paper analyzes the need to study how inclusion of multiple energy infrastructure integration and responsive load can impact the future distribution network costs.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. 38 no. 2
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 1 November 1979

Energy costs now dictate that heating and ventilation systems must be controlled to the closest possible degree. Technology — particularly in the form of computers — imposes its…

Abstract

Energy costs now dictate that heating and ventilation systems must be controlled to the closest possible degree. Technology — particularly in the form of computers — imposes its own demands for ‘clean air’ working and constant power. And there are stringent provisions to be met under the health and safety laws. Together, these factors have created a buoyant market for equipment suppliers.

Details

Industrial Management, vol. 79 no. 11
Type: Research Article
ISSN: 0007-6929

Article
Publication date: 7 September 2015

Nelson Soares, Luísa Dias Pereira, João Ferreira, Pedro Conceição and Patrícia Pereira da Silva

This paper aims to propose an energy efficiency plan (with technical and behavioural improvement measures) for a Portuguese higher education building – the Teaching Building of…

2039

Abstract

Purpose

This paper aims to propose an energy efficiency plan (with technical and behavioural improvement measures) for a Portuguese higher education building – the Teaching Building of the Faculty of Economics of the University of Coimbra (FEUC).

Design/methodology/approach

The study was developed in the context of both the “Green Campus – Challenge for Energy Efficiency in Higher Education” and the Energy for Sustainability Initiative of the University of Coimbra, Portugal. An energy audit was conducted based on the analysis of the energy consumption profiles. A monitoring campaign was carried out to measure and disaggregate the electricity consumption. The consumption of natural gas and water were also assessed. The building envelope and the heating and lighting systems were also evaluated. Some patterns of energy-environmental behaviours of the academic community were investigated through a Web-based survey.

Findings

The energy efficiency plan contemplates short-term tangible/intangible actions. It also considers the investment and payback period of the tangible measures. The implementation of three improvement measures in the lighting system would lead to a consumption reduction of about 26,123 kWh/year, avoiding the emission of 3,704 KgCO2/year, for an initial cost of 9,920 (payback period of 3.7 years).

Research limitations/implications

Results are restricted to the case study and there are limitations in their generalisation outside of their context. However, they show some broadly implications and trends that have relevance for the higher education sector. This paper highlights the importance of engaging students, faculty and technical staff for working together on the assessment of the energy efficiency of the buildings where they study and work.

Social implications

The higher education sector holds important functions in educating the next generation of professionals for a sustainable culture. The categories of activities described in this paper are good examples of what can be done within the academic community for acting towards sustainability. The results also pointed out that making users aware of their energy consumption is a priority towards the energy efficiency in higher education buildings.

Originality/value

Reductions on energy consumption are expected if the energy efficiency plan would be implemented. The results of the behavioural study were presented to the FEUC’s board of directors to be integrated in the “Good Practices Manual on Water and Energy Management”.

Details

International Journal of Sustainability in Higher Education, vol. 16 no. 5
Type: Research Article
ISSN: 1467-6370

Keywords

Article
Publication date: 7 November 2022

Rajamohana Kuselan and Venkatesan Sundharajan

This study aims to extend the driving range by on-board charging with use of photovoltaic (PV) source, avoiding the dependency on the grid supply and energy storage system in…

Abstract

Purpose

This study aims to extend the driving range by on-board charging with use of photovoltaic (PV) source, avoiding the dependency on the grid supply and energy storage system in addition to that reduce the conversion complexity influenced on converter section of electric vehicle (EV) system.

Design/methodology/approach

This paper proposed a PV fed integrated converter topology called integrated single-input multi-output (I-SIMO) converter with enriched error tolerant fuzzy logic controller (EET-FLC) based control technique to regulate the speed of brushless direct current motor drive. I-SIMO converter provides both direct current (DC) and alternating current (AC) outputs from a single DC input source depending on the operation mode. It comprises two modes of operation, act as DC–DC converter in vehicle standby mode and DC–AC converter in vehicles driving mode.

Findings

The use of PV panels in the vehicle helps to reduce dependence of grid supply as well as vehicle’s batteries. The proposed topology has to remove the multiple power conversion stages in EV system, reduce components count and provide dual outputs for enhancement of performance of EV system.

Originality/value

The proposed topology leads to reduction of switching losses and stresses across the components of the converter and provides reduction in system complexity and overall expenditure. So, it enhances the converter reliability and also improves the efficiency. The converter provides ripple-free output voltage under dynamic load condition. The performance of EET-FLC is studied by taking various performance measures such as rise time, peak time, settling time and peak overshoot and compared with conventional control designs.

Article
Publication date: 4 November 2020

Ayda Montaser Koohsari and Shahin Heidari

The purpose of this paper is to determine the approximate window-to-wall ratio (WWR), window width-to-height ratio (WHR) and sill level for a room in Rasht–Gilan province and to…

Abstract

Purpose

The purpose of this paper is to determine the approximate window-to-wall ratio (WWR), window width-to-height ratio (WHR) and sill level for a room in Rasht–Gilan province and to present an optimal window in each of the WWR ranges providing the minimum energy consumption by integrating artificial lighting and thermal analyses, whilst maintaining internal comfort conditions using dynamic evaluation.

Design/methodology/approach

The process of modelling has four main steps: 1 – defining the building's features and requirements, 2 – validating input weather file data by on-site measurement, 3 – determining input parameters for the lighting and thermal analysis and 4 – clarifying variable parameters and fitness function for the optimization algorithm. Also, the survey study is performed in a daylit office room, in which 30 employees are employed to answer the questions in three different times of a day. In this process, the impact of daylight on their visual comfort is surveyed in 1,350 different illuminance levels which are manually recorded.

Findings

The range of useful daylight illuminance (UDI) values is determined as 200–1,000 lux. The optimum range of WWRs in the case study is 15%–25%. Also, due to the appropriate window height, electric lighting could be decreased by 40%.

Originality/value

Thermal and lighting performance in buildings is the relation of facade characteristics to environmental sustainability. Recent studies focussed on optimizing WWR and window characteristics considering thermal comfort and energy analyses. However, architects need freedom for designing façade and making decisions in their first sketches. Thus a guideline for optimum window conditions in each WWR is required. Also, considering occupants' behaviour in practical buildings, the visual comfort investigation is a gap in WWR optimization.

Details

Built Environment Project and Asset Management, vol. 11 no. 4
Type: Research Article
ISSN: 2044-124X

Keywords

Open Access
Article
Publication date: 5 April 2023

Shan Chen, Yuandi Wang, Hongping Du and Zhiyu Cui

Although the tasks of managing carbon peaks and achieving carbon neutrality in China are arduous, they are also of great significance, which highlights China’s determination and…

Abstract

Purpose

Although the tasks of managing carbon peaks and achieving carbon neutrality in China are arduous, they are also of great significance, which highlights China’s determination and courage in dealing with climate change. The power industry is not only a major source of carbon emissions but also an important area for carbon emission reduction. Thus, against the backdrop of carbon neutrality, understanding the development status of China’s power industry guided by the carbon neutrality background is important because it largely determines the completeness of China’s carbon reduction promises to the world. This study aims to review China’s achievements in carbon reduction in the electric industry, its causes and future policy highlights.

Design/methodology/approach

The methods used in this study include descriptive analyses based on official statistics, government documents and reports.

Findings

The research results show that, after years of development, the power industry has achieved positive results in low-carbon provisions and in the electrification of consumption, and carbon emission intensity has continued to decline. Policy initiatives play a key role in this process, including, but not limited to, technology innovations, low-carbon power replacement and supported policies for low-carbon transformation toward low-carbon economies.

Originality/value

This study provides a full picture of China’s power industry against the backdrop of low-carbon development, which could be used as a benchmark for other countries engaging in the same processes. Moreover, a careful review of China’s development status may offer profound implications for policymaking both for China and for other governments across the globe.

Details

International Journal of Climate Change Strategies and Management, vol. 15 no. 2
Type: Research Article
ISSN: 1756-8692

Keywords

Article
Publication date: 21 January 2019

Stephen loh Tangwe and Michael Simon

This paper aims to compute demand, consumption and other avoidance saving by replacing existing geysers with split and integrated type air source heat pump (ASHP) water heaters…

Abstract

Purpose

This paper aims to compute demand, consumption and other avoidance saving by replacing existing geysers with split and integrated type air source heat pump (ASHP) water heaters, to prove the potential of both ASHP water heaters in both winter and summer by virtue of their coefficient of performance (COP) during the vapour compression refrigeration cycles and to demonstrate that despite the viability of both split and integrated ASHP system, the latter exhibits a better performance in terms of its COP and achievable savings and load factor.

Design/methodology/approach

This research emphasised the use of the data acquisition system housing various temperature sensors, power metres, flow metre, ambient temperature and relative humidity sensor to determine electrical energy consumption and useful thermal energy gained by the hot water in a geyser and storage tanks of residential ASHP water heaters. The load factors, average power and electrical energy consumptions for the 150 L high-pressure geyser, a 150 L split and integrated type ASHP water heaters were evaluated based on the controlled volume (150, 50 and 100 L) of daily hot water drawn off.

Findings

The results depicted that the average electrical energy consumed and load factors of the summer months for the geyser, split and integrated type ASHP water heaters were 312.3, 111.7 and 121.1 kWh and 17.9, 10.2 and 16.7 per cent, respectively. Finally, the simple payback period for both the split and integrated type ASHP water heaters were determined to be 3.9 and 5.2 years, respectively. By the application of the Eskom’s projected tariff hikes over the years, the payback periods for the split and integrated ASHP water heaters could be reduced to 3.3 and 4.1 years, respectively.

Research limitations/implications

The experiments were conducted in a controlled outdoor research facility as it was going to be of great challenge in conducting both experiments simultaneously in a specific home. The category of the different types of ASHP water heaters was limited to one due to the cost implication. The experiment was also conducted at a single location, which is not a full representation of all the ambient conditions of the different regions of South Africa.

Practical implications

The experiments were done with a specific controlled volume of hot water drawn off from each of the three hot water heating devices. The experiments was structuring controlled to a specific volume of hot water drawn off and at specific period of the day and hence to not cater for random drawers and intermittent drawn off.

Social implications

The findings help to assure homeowners that irrespective of the type of ASHP water heaters installed in their residence, they can be guarantee of year-round performance and a favourable payback period provided their hot water consumption is over 200 L per day. Also, although the split type ASHP water heater performed better than the integrated system the cost of installation and maintenance will be higher in a split type in comparison to the integrated type. Finally, by successful implementation of either of the ASHP water heaters the home owner can substantially save of his hot water bill.

Originality/value

The experimental design and methodology is the first of its kind to be conducted in South Africa. The results and interpretation were obtained from original data collected from the set of experiments conducted. Also, the authors are able to show that the introduction of back up element in an ASHP unit to run simultaneously with the vapour compression refrigeration cycles of the ASHP can reduce the COP of the overall system.

Details

Journal of Engineering, Design and Technology, vol. 17 no. 2
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 3 October 2016

Ganesh S. Warkhade, A. Veeresh Babu, Santosh Mane and Katam Ganesh Babu

Solar energy varies with time, intermittent; an accumulator unit is required to attach with collectors to collect energy for use when the sunshine is not available. This paper…

Abstract

Purpose

Solar energy varies with time, intermittent; an accumulator unit is required to attach with collectors to collect energy for use when the sunshine is not available. This paper aims to design a system for storing the solar sensible heat thermal energy.

Design/methodology/approach

This paper presents the design and experimental evaluation of sensible heat thermal energy storage (TES) system for its energy storage performance by varying the air flow rate and packing material shape. Heat transfer fluid as air and solid concrete material of high density of different shapes were used for storage.

Findings

This paper presents the evaluation of data of number of experimental observations on the system. It was found that charging/discharging was based on the shape of the material and void fraction.

Originality/value

This paper provides the data for designing the TES, considering the concrete as storage material and shape of material for optimizing the system.

Details

World Journal of Engineering, vol. 13 no. 5
Type: Research Article
ISSN: 1708-5284

Keywords

1 – 10 of 96