Article
Publication date: 4 March 2020

Eva Lubloy

The aim of the research was to investigate the effect of concrete strength on the fire resistance of structures. At first, it may seem contradictory that higher concrete strengths…

Abstract

Purpose

The aim of the research was to investigate the effect of concrete strength on the fire resistance of structures. At first, it may seem contradictory that higher concrete strengths can decrease the fire resistance of building structures. However, if the strength of the concrete exceeds a maximum value, the risk of spalling (the detachment of the concrete surface) significantly.

Design/methodology/approach

Prefabricated structural elements are often produced with higher strength. The higher concrete strengths generally do not cause a reduction in the load bearing capacity, but it can have serious consequences in case of structural fire design. Results of two prefabricated elements, namely, one slab (TT shaped panel) and one single layer wall panel, were examined. Results of the specimen with the originally designed composition and a specimen with modified concrete composition were examined, were polymer fibres were added to prevent spalling.

Findings

As a result of the experiments, more strict regulations in the standards the author is suggested including more strict regulations in the standards. It has been proved that to ensure the fire safety of the reinforced concrete structures, it is required after polymer fibres even in lower concrete strength class than prescribed by the standard. In addition, during the classification and evaluation of structures, it is advisable to introduce an upper limit of allowed concrete strength for fire safety reasons.

Originality/value

As a result of the experiments, the author suggests including more strict regulations in the standards. It has been proved that to ensure the fire safety of the reinforced concrete structures, it is necessary to require the addition of polymer fibres even in lower concrete strength class than prescribed by the standard. In addition, during the classification and evaluation of structures, it is advisable to introduce an upper limit of allowed concrete strength for fire safety reasons.

Details

Journal of Structural Fire Engineering, vol. 11 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 30 May 2023

Renato Silva Nicoletti, Tawan Oliveira, Alex Sander Clemente de Souza and Silvana De Nardin

In the analysis of structures in a fire situation by simplified and analytical methods, one assumption is that the fire resistance time is greater than or equal to the required…

Abstract

Purpose

In the analysis of structures in a fire situation by simplified and analytical methods, one assumption is that the fire resistance time is greater than or equal to the required fire resistance time. Among the methodologies involving the fire resistance time, the most used is the tabular method, which associates fire resistance time values to structural elements based on minimum dimensions of the cross section. The tabular method is widely accepted by the technical-scientific community due to the fact that it is safe and practical. However, its main criticism is that it results in lower fire resistance times than advanced thermal and thermostructural analysis methods. The objective of this study was to evaluate the fire resistance time of reinforced concrete beams and compare it with the required fire resistance time recommended by the tabular method of NBR 15200 (ABNT, 2012).

Design/methodology/approach

The fire resistance time and required fire resistance time of reinforced concrete beams were evaluated using, respectively, numerical models developed based on the finite element method and the tabular method of NBR 15200 (ABNT, 2012). The influence of the following parameters was investigated: longitudinal reinforcement cover, characteristic compressive strength of concrete, beam height, longitudinal reinforcement area and arrangement of steel bars.

Findings

Among the evaluated parameters, the covering of the longitudinal reinforcement proved to be more relevant for the fire resistance time, justifying that the tabular method of NBR 15200 (ABNT, 2012) being strongly and directly influenced by this parameter. In turn, more resistant concretes, higher beams and higher steel grades have lower fire resistance time values. This is because beams in these conditions have greater resistance capacity at room temperature and, consequently, are subject to external stresses of greater magnitude. In some cases, the fire resistance time was even lower than the required fire resistance time prescribed by NBR 15200 (ABNT, 2012). Both the fire resistance time and the required fire resistance time were not influenced by the arrangement of the longitudinal reinforcements.

Originality/value

The present paper innovates by demonstrating the influence of other important design variables on the required fire resistance time of the NBR 15200 (ABNT, 2012). Among several conclusions, it was found that the load level to which the structural elements are subjected considerably affects their fire resistance time. For this reason, it was recommended that the methods for calculating the required fire resistance time consider the load level. In addition, the article quantifies the security degree of the tabular method and exposes some situations for which the tabular method proved to be unsafe. Moreover, in all the models analyzed, the relationship between the span and the vertical deflection associated with the failure of the beams in a fire situation was determined. With this, a span over average deflection relationship was presented in which beams in fire situations fail.

Details

Journal of Structural Fire Engineering, vol. 15 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 7 July 2017

Kristian Hertz, Luisa Giuliani and Lars Schiøtt Sørensen

Prefabricated extruded hollow-core slabs are preferred building components for floor structures in several countries. It is therefore important to be able to document the fire

Abstract

Purpose

Prefabricated extruded hollow-core slabs are preferred building components for floor structures in several countries. It is therefore important to be able to document the fire resistance of these slabs proving fulfilment of standard fire resistance requirements of 60 and 120 min found in most national building regulations. The paper aims to present a detailed analysis of the mechanisms responsible for the loss of load-bearing capacity of hollow-core slabs when exposed to fire.

Design/methodology/approach

Furthermore, it compares theoretical calculation and assessment according to the structural codes with data derived from a standard fire test and from a thorough examination of the comprehensive test documentation available on fire exposed hollow-core slabs.

Findings

Mechanisms for loss of load-bearing capacity are clarified, and evidence of the fire resistance is found.

Originality value

For the first time, the mechanisms responsible for loss of load-bearing capacity are identified, and test results and calculation approach are for the first time applied in accordance with each other for assessment of fire resistance of the structure.

Details

Journal of Structural Fire Engineering, vol. 8 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 27 November 2023

Maha Assad, Rami Hawileh, Ghada Karaki, Jamal Abdalla and M.Z. Naser

This research paper aims to investigate reinforced concrete (RC) walls' behaviour under fire and identify the thermal and mechanical factors that affect their performance.

Abstract

Purpose

This research paper aims to investigate reinforced concrete (RC) walls' behaviour under fire and identify the thermal and mechanical factors that affect their performance.

Design/methodology/approach

A three-dimensional (3D) finite element (FE) model is developed to predict the response of RC walls under fire and is validated through experimental tests on RC wall specimens subjected to fire conditions. The numerical model incorporates temperature-dependent properties of the constituent materials. Moreover, the validated model was used in a parametric study to inspect the effect of the fire scenario, reinforcement concrete cover, reinforcement ratio and configuration, and wall thickness on the thermal and structural behaviour of the walls subjected to fire.

Findings

The developed 3D FE model successfully predicted the response of experimentally tested RC walls under fire conditions. Results showed that the fire resistance of the walls was highly compromised under hydrocarbon fire. In addition, the minimum wall thickness specified by EC2 may not be sufficient to achieve the desired fire resistance under considered fire scenarios.

Originality/value

There is limited research on the performance of RC walls exposed to fire scenarios. The study contributed to the current state-of-the-art research on the behaviour of RC walls of different concrete types exposed to fire loading, and it also identified the factors affecting the fire resistance of RC walls. This guides the consideration and optimisation of design parameters to improve RC walls performance in the event of a fire.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 1 February 1985

Margaret Law

In this country, as well as in most others, the level of structural fire protection is set by the regulatory authorities, in terms of a specified fire resistance period. The…

Abstract

In this country, as well as in most others, the level of structural fire protection is set by the regulatory authorities, in terms of a specified fire resistance period. The engineer must demonstrate that each element of structure would survive for the required period if it were subjected to the standard fire resistance test of BS476. This is normally demonstrated by using tabular data, such as the deemed‐to‐satisfy tables in the Building Regulations, or by obtaining a report of a test of a replica of the particular element.

Details

Structural Survey, vol. 3 no. 2
Type: Research Article
ISSN: 0263-080X

Article
Publication date: 13 May 2014

Behrouz Behnam and Hamid Reza Ronagh

Post-earthquake fire (PEF) can lead to a rapid collapse of structures partially damaged by earthquake. As there is almost no established PEF provisions by codes and standards, PEF…

Abstract

Purpose

Post-earthquake fire (PEF) can lead to a rapid collapse of structures partially damaged by earthquake. As there is almost no established PEF provisions by codes and standards, PEF investigations are therefore needed for those buildings. The paper aims to discuss these issues.

Design/methodology/approach

A non-linear PEF analysis comprises three steps, which are the application of gravity loads, earthquake loads and then fire loads. As a fire generally initiates on one floor and then spreads to other floors, applying a sequential fire is more realistic than applying a concurrent fire on several floors. Hence, in this study, the fire is applied sequentially to the floors with a time delay.

Findings

The results indicate a substantial reduction in the resistance of the damaged frame when subjected to PEF. In addition, the results of applying the PEF sequentially is more realistic than the concurrent fire.

Research limitations/implications

It was better to perform an experimental test to have a better understanding of the issue.

Originality/value

PEF can potentially result in a catastrophe in areas located in seismic regions. Thus, investigating the effect of PEF on previously damaged structures is of importance.

Details

International Journal of Structural Integrity, vol. 5 no. 2
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 5 March 2021

Muhannad R. Alasiri and Mustafa Mahamid

Standard fire resistance curves such as ASTM E119 have been used for so long in structural fire practice. The issue with use of these curves that they do not represent real fire

Abstract

Purpose

Standard fire resistance curves such as ASTM E119 have been used for so long in structural fire practice. The issue with use of these curves that they do not represent real fire scenarios. As a result, the alternatives have been to either conduct experiments or find other tools to represent a real fire scenario. Therefore, the purpose of this paper is to understand the temperature effects resulted from a designed fire on steel beams and whether the standard fire curves represent a designed fire scenario.

Design/methodology/approach

Computational fluid dynamics (CFD) models were developed to simulate a designed fire scenario and to understand the structural responses on the beams under elevated temperatures. Consequently, the results obtained from the CFD models were compared with the results of three-dimensional (3D) non-linear finite element (FE) models developed by other researchers. The developed FE models were executed using a standard fire curve (ASTM E119). A parametric study including two case studies was conducted.

Findings

Results obtained from performing this study showed the importance of considering fire parameters such as fuel type and flame height during the thermal analysis compared to the standard fire curves, and this might lead to a non-conservative design as compared to the designed fire scenario. The studied cases showed that the steel beams experienced more degradation in their fire resistance at higher load levels under designed fires. Additionally, the models used the standard fire curves underestimated the temperatures at the early stages.

Originality/value

This paper shows results obtained by performing a comparison study of models used ASTM E119 curve and a designed fire scenario. The value of this study is to show the variability of using different fire scenarios; thus, more studies are required to see how temperature history curves can be used to represent real fire scenarios.

Details

Journal of Structural Fire Engineering, vol. 12 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 7 October 2021

Lisa Choe, Selvarajah Ramesh, Xu Dai, Matthew Hoehler and Matthew Bundy

The purpose of this paper is to report the first of four planned fire experiments on the 9.1 × 6.1 m steel composite floor assembly as part of the two-story steel framed building…

Abstract

Purpose

The purpose of this paper is to report the first of four planned fire experiments on the 9.1 × 6.1 m steel composite floor assembly as part of the two-story steel framed building constructed at the National Fire Research Laboratory.

Design/methodology/approach

The fire experiment was aimed to quantify the fire resistance and behavior of full-scale steel–concrete composite floor systems commonly built in the USA. The test floor assembly, designed and constructed for the 2-h fire resistance rating, was tested to failure under a natural gas fueled compartment fire and simultaneously applied mechanical loads.

Findings

Although the protected steel beams and girders achieved matching or superior performance compared to the prescribed limits of temperatures and displacements used in standard fire testing, the composite slab developed a central breach approximately at a half of the specified rating period. A minimum area of the shrinkage reinforcement (60 mm2/m) currently permitted in the US construction practice may be insufficient to maintain structural integrity of a full-scale composite floor system under the 2-h standard fire exposure.

Originality/value

This work was the first-of-kind fire experiment conducted in the USA to study the full system-level structural performance of a composite floor system subjected to compartment fire using natural gas as fuel to mimic a standard fire environment.

Details

Journal of Structural Fire Engineering, vol. 13 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 15 July 2022

Tulio Coelho, Sofia Diniz, Francisco Rodrigues and Ruben Van Coile

This paper aims to investigate the state of the art for the reliability evaluation of reinforced concrete beams in a fire situation. Special emphasis is placed on addressing which…

Abstract

Purpose

This paper aims to investigate the state of the art for the reliability evaluation of reinforced concrete beams in a fire situation. Special emphasis is placed on addressing which parameters were considered probabilistically or deterministically, the prescribed probabilistic models for the assumed stochastic variables, the treatment of the heat transfer mechanism, the quantification of the structural fire performance and the assumed target reliability levels.

Design/methodology/approach

Research papers were identified through a search on the Web of Science, Google Scholar and detailed searches within the journals Journal of Structural Fire Engineering, Fire Technology and Fire Safety Journal, supplemented with references known by the authors.

Findings

Considering the state-of-the-art review, gaps in the literature are identified related to (1) the probabilistic evaluation of shear capacity for standard fires and parametric fires, and bending capacity for parametric fires, (2) the absence of reference fragility curves for immediate design application/code calibration and (3) the specification of target safety levels for reliability-based design.

Originality/value

The lack of research papers gathering studies on the reliability of reinforced concrete beams in fire situation makes it difficult to further develop research in the area. The value of this work lies precisely in the collection of the basic information, making it possible to identify gaps to be addressed in future research and the suggestion of a research framework.

Details

Journal of Structural Fire Engineering, vol. 14 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 13 March 2017

Venkatesh Kodur, James Stein, Rustin Fike and Mahmood Tabbador

This paper aims to present an evaluation of comparative fire resistance on traditional and engineered wood joists used in the construction of floor systems in residential housing.

Abstract

Purpose

This paper aims to present an evaluation of comparative fire resistance on traditional and engineered wood joists used in the construction of floor systems in residential housing.

Design/methodology/approach

Fire resistance experiments were carried out on four types of wood joists, namely, traditional lumber, engineered I-joist, castellated I-joist and steel/wood hybrid joist, used in traditional and modern residential construction. The test variables included type of wood joist, support conditions and fire protection (insulation).

Findings

Results from these tests indicate that webs of engineered I-joists and castellated I-joists are highly susceptible to fire, and failure generally occurs through the burn-out of the web. In addition, engineered I-joists have much lower fire resistance than traditional solid joist lumber. The application of an intumescent coating on an engineered I-joist significantly enhances its fire resistance and yields a similar level of fire resistance as that of a traditional lumber joist.

Originality/value

The presented fire tests are unique and provide valuable insight (and information) to the behavior and response of four types of wood joists when subjected to gravity loading and fire conditions.

Details

Journal of Structural Fire Engineering, vol. 8 no. 1
Type: Research Article
ISSN: 2040-2317