Search results

1 – 10 of 222
Article
Publication date: 17 July 2020

Majid M.A. Kadhim

This paper is aimed at clarifying the behaviour of concrete-filled stainless steel tube (CFSST) slender columns. Based on the review of previous works, it can be found that the…

Abstract

Purpose

This paper is aimed at clarifying the behaviour of concrete-filled stainless steel tube (CFSST) slender columns. Based on the review of previous works, it can be found that the pieces of research on the behaviour of CFSST slender columns are very rare and the existing studies, to the author’s knowledge, have not covered this topic in greater depth. The purpose of this paper is to investigate the structural response and strength capacity of eccentric loaded long CFSST columns.

Design/methodology/approach

In this paper, a new finite element (FE) model is presented for predicting the nonlinear behaviour of CFSST slender columns under eccentric load. The FE model developed accounts for confinement influences of the concrete in-filled material. In addition, the initial local and overall geometric imperfections were introduced in the numerical model in addition to the inelastic response of stainless steel. The interaction between the stainless section and concrete in-filled was modelled using contact pair algorithm. The FE model was then verified against an experimental work presented in the literature. The ultimate strengths, axial load–lateral displacement and failure mode of CFSST slender columns predicted by the FE model were validated against corresponding experimental results.

Findings

The simulation results show that the improvement in the column strengths (compared to hollow section) is less significant when the composite columns have small width-to-thickness ratio. Finally, comparisons were made between the results obtained from FE simulation and those computed from the Eurocode 4 (EC4). It has been found that the EC4 predictions in most analysed cases are conservative for composite columns analysed under a combination of axial load and uniaxial or biaxial bending. However, the conservatism of the code is reduced with a higher slenderness ratio of the composite columns.

Practical implications

The simulation results throughout this research were compared with the corresponding Eurocode predictions.

Originality/value

This paper provides new findings about the structural behaviour of CFSST columns.

Details

World Journal of Engineering, vol. 17 no. 5
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 8 May 2018

M.M. Shahin, Mohammad Asaduzzaman Chowdhury, Md. Arefin Kowser, Uttam Kumar Debnath and M.H. Monir

The purposes of the present study are to ensure higher sustainability of journal bearings under different applied loads and to observe bearing performances such as elastic strain…

Abstract

Purpose

The purposes of the present study are to ensure higher sustainability of journal bearings under different applied loads and to observe bearing performances such as elastic strain, total deformation and stress formation.

Design/methodology/approach

A journal bearing test rig was used to determine the effect of the applied load on the bearing friction, film thickness, lubricant film pressure, etc. A steady-state analysis was performed to obtain the bearing performance.

Findings

An efficient aspect ratio (L/D) range was obtained to increase the durability or the stability of the bearing while the bearing is in the working condition by using SAE 5W-30 oil. The results from the study were compared with previous studies in which different types of oil and water, such as Newtonian fluid (NF), magnetorheological fluid (MRF) and nonmagnetorheological fluid (NMRF), were used as the lubricant. To ensure a preferable aspect ratio range (0.25-0.50), a computational fluid dynamics (CFD) analysis was conducted by ANSYS; the results show a lower elastic strain and deformation within the preferable aspect ratio (0.25-0.50) rather than a higher aspect ratio using the SAE 5W-30 oil.

Originality/value

It is expected that the findings of this study will contribute to the improvement of the bearing design and the bearing lubricating system.

Details

Industrial Lubrication and Tribology, vol. 70 no. 4
Type: Research Article
ISSN: 0036-8792

Keywords

Article
Publication date: 14 December 2021

Fuminobu Ozaki and Takumi Umemura

In this study, the bending strength, flexural buckling strength and collapse temperature of small steel specimens with rectangular cross-sections were examined by steady and…

Abstract

Purpose

In this study, the bending strength, flexural buckling strength and collapse temperature of small steel specimens with rectangular cross-sections were examined by steady and transient state tests with various heating and deformation rates.

Design/methodology/approach

The engineering stress and strain relationships for Japan industrial standard (JIS) SN400 B mild steels at elevated temperatures were obtained by coupon tests under three strain rates. A bending test using a simple supported small beam specimen was conducted to examine the effects of the deformation rates on the centre deflection under steady-state conditions and the heating rates under transient state conditions. Flexural buckling tests using the same cross-section specimen as that used in the bending test were conducted under steady-state and transient-state conditions.

Findings

It was clarified that the bending strength and collapse temperature are evaluated by the full plastic moment using the effective strength when the strain is equal to 0.01 or 0.02 under fast strain rates (0.03 and 0.07 min–1). In contrast, the flexural buckling strength and collapse temperature are approximately evaluated by the buckling strength using the 0.002 offset yield strength under a slow strain rate (0.003 min–1).

Originality/value

Regarding both bending and flexural buckling strengths and collapse temperatures of steel members subjected to fire, the relationships among effects of steel strain rate for coupon test results, heating and deformation rates for the heated steel members were minutely investigated by the steady and transient-state tests at elevated temperatures.

Article
Publication date: 7 September 2023

Nor Salwani Hashim, Fatimah De’nan and Nurfarhah Naaim

Nowadays, residential buildings have become increasingly important due to the growing communities. The purpose of this study is to investigate the behavior of a steel structural…

Abstract

Purpose

Nowadays, residential buildings have become increasingly important due to the growing communities. The purpose of this study is to investigate the behavior of a steel structural framing system that incorporates lightweight load-bearing walls and slabs, and to compare the weight of materials used in cold-formed and hot-finished steel structural systems for affordable housing.

Design/methodology/approach

Four types of models consisting of 243 members were simulated. Model 1 is a cold-formed steel structural framing system, while Model 2 is a hot-finished steel structural framing system. Both Models 1 and 2 use lightweight wall panels and lightweight composite slabs. Models 3 and 4 are made with brick walls and precast reinforced concrete systems, respectively. These structures use different wall and slab materials, namely, brick walls and precast reinforced concrete. The analysis includes bending behavior, buckling resistance, shear resistance and torsional rotation analysis.

Findings

This study found that using thinner steel sections can increase the deflection value. Meanwhile, increasing member length and the ratio of slenderness will decrease buckling resistance. As the applied load increases, buckling deformation also increases. Furthermore, decreasing shear area causes a reduction in shear resistance. Thicker sections and the use of lightweight materials can decrease the torsional rotation value.

Originality/value

The weight comparison of the steel structures shows that Model 1, which is a cold-formed steel structure with lightweight wall panels and lightweight composite slabs, is the most suitable model due to its lightweight and affordability for housing. This model can also be used as a reference for the optimal design of modular structural framing using cold-formed steel materials in the field of civil engineering and as a promotional tool.

Details

World Journal of Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 11 January 2022

Abdelkadir Fellouh, Abdelkader Bougara, Paulo Piloto and Nourredine Benlakehal

Investigate the fire performance of eccentrically loaded concrete partially encased column (PEC), using the advanced calculation method (ANSYS 18.2, 2017) and the simple…

Abstract

Purpose

Investigate the fire performance of eccentrically loaded concrete partially encased column (PEC), using the advanced calculation method (ANSYS 18.2, 2017) and the simple calculation method in Annex G of Eurocode 4 (EN 1994-1-2, 2005). This work examines the influence of a range of parameters on fire behaviour of the composite column including: eccentricity loading, slenderness, reinforcement, fire rating and fire scenario. In this study, ISO-834 (ISO834-1, 1999) was used as fire source.

Design/methodology/approach

Currently, different methods of analysis used to assess the thermal behaviour of composite column exposed to fire. Analytical method named simplified calculation methods defined in European standard and numerical simulations named advanced calculation models are treated in this paper.

Findings

The load-bearing capacity of the composite column becomes very weak in the presence of the fire accident and eccentric loading, this recommends to avoid as much as possible eccentric loading during the design of construction building. The reinforcement has a slight influence on the temperature evolution; moreover, the reinforcement has a great contribution on the load capacity, especially in combined compression and bending. When only the two concrete sides are exposed to fire, the partially encased composite column presents a high load-bearing capacity value.

Originality/value

The use of a three-dimensional numerical model (ANSYS) allowed to describe easily the thermal behaviour of PEC columns under eccentric loading with the regard to the analytical method, which is based on three complex steps. In this study, the presence of the load eccentricity has found to have more effect on the load-bearing capacity than the slenderness of the composite column. Introducing a load eccentricity on the top of the column may have the same a reducing effect on the load-bearing capacity as the fire.

Details

Journal of Structural Fire Engineering, vol. 13 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 10 November 2023

Varun Sabu Sam, M.S. Adarsh, Garry Robson Lyngdoh, Garry Wegara K. Marak, N. Anand, Khalifa Al-Jabri and Diana Andrushia

The capability of steel columns to support their design loads is highly affected by the time of exposure and temperature magnitude, which causes deterioration of mechanical…

Abstract

Purpose

The capability of steel columns to support their design loads is highly affected by the time of exposure and temperature magnitude, which causes deterioration of mechanical properties of steel under fire conditions. It is known that structural steel loses strength and stiffness as temperature increases, particularly above 400 °C. The duration of time in which steel is exposed to high temperatures also has an impact on how much strength it loses. The time-dependent response of steel is critical when estimating load carrying capacity of steel columns exposed to fire. Thus, investigating the structural response of cold-formed steel (CFS) columns is gaining more interest due to the nature of such structural elements.

Design/methodology/approach

In this study, experiments were conducted on two CFS configurations: back-to-back (B-B) channel and toe-to-toe (T-T) channel sections. All CFS column specimens were exposed to different temperatures following the standard fire curve and cooled by air or water. A total of 14 tests were conducted to evaluate the capacity of the CFS sections. The axial resistance and yield deformation were noted for both section types at elevated temperatures. The CFS column sections were modelled to simulate the section's behaviour under various temperature exposures using the general-purpose finite element (FE) program ABAQUS. The results from FE modelling agreed well with the experimental results. Ultimate load of experiment and finite element model (FEM) are compared with each other. The difference in percentage and ratio between both are presented.

Findings

The results showed that B-B configuration showed better performance for all the investigated parameters than T-T sections. A noticeable loss in the ultimate strength of 34.5 and 65.6% was observed at 90 min (986℃) for B-B specimens cooled using air and water, respectively. However, the reduction was 29.9 and 46% in the T-T configuration, respectively.

Originality/value

This research paper focusses on assessing the buckling strength of heated CFS sections to analyse the mode of failure of CFS sections with B-B and T-T design configurations under the effect of elevated temperature.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 1 August 1944

R.H. Grundy

TO check the suitability of a given strut cross‐section, for a given length and safe concentric working load, is a simple matter provided that a working stress curve or formula is…

Abstract

TO check the suitability of a given strut cross‐section, for a given length and safe concentric working load, is a simple matter provided that a working stress curve or formula is available, but the reverse process of obtaining a suitable cross‐section, for a given length and load is under normal circumstances a tedious trial and error task, unless comprehensive tables of the properties of the required section arc available. The author's method permits a very close first approximation to be obtained, which is frequently sufficiently accurate to enable the required cross‐section to be laid out without further trial.

Details

Aircraft Engineering and Aerospace Technology, vol. 16 no. 8
Type: Research Article
ISSN: 0002-2667

Open Access
Article
Publication date: 7 October 2022

Hüseyin Emre Ilgın

To date, there are no studies in the literature that provide a comprehensive understanding of the interrelationships between the slenderness ratio and the main design criteria in…

2039

Abstract

Purpose

To date, there are no studies in the literature that provide a comprehensive understanding of the interrelationships between the slenderness ratio and the main design criteria in supertall towers (=300 m). In this paper, this important issue was explored using detailed data collected from 75 cases.

Design/methodology/approach

This paper was carried out with a comprehensive literature review including the database of the Council on Tall Buildings and Urban Habitat(CTBUH) (CTBUH, 2022), peer-reviewed journals, MSc theses and PhD dissertations, conference proceedings, fact sheets, architectural and structural magazines and other Internet sources. In this study, the case study method was also used to gather and consolidate information about supertall towers to analyze the interrelationships. Cases were 75 supertall buildings in various countries [44 from Asia (37 from China), 16 from the Middle East (6 from Dubai, the United Arab Emirates), 11 from the United States of America and 3 from Russia, 1 from the UK].

Findings

The paper's findings highlighted as follows: (1) for buildings in the height range of 300–399 m, the slenderness ratio was usually between 7 and 7.9 and megatall towers were frequently built at a slenderness ratio of 10–15; (2) the median slenderness ratio of buildings in the 400–599 m height ranges was around 8.6; (3) a trend towards supertall slender buildings (=8) was observed in Asia, the Middle East and North America; (4) residential, office and mixed-use towers had a median slenderness ratio of over 7.5; (5) all building forms were utilized in the construction of slender towers (>8); (6) the medium slenderness ratio was around 8 for supertall buildings constructed with outriggered frame and tube systems; (7) especially concrete towers reached values pushing the limits of slenderness (>10) and (8) since the number of some supertall building groups (e.g. steel towers) was not sufficient, establishing a scientific relationship between aspect ratio and related design criteria was not possible.

Originality/value

To date, there are no studies in the literature that provide a comprehensive understanding of the interrelationships between the slenderness ratio and the main design criteria in supertall towers (=300 m). This important issue was explored using detailed data collected from 75 cases.

Details

International Journal of Building Pathology and Adaptation, vol. 41 no. 6
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 23 September 2020

Fatimah De'nan, Nor Salwani Hashim and Lim Cheng Kuan

Tapered section can resist maximum stress at a single location while the stresses are considerably lower at the rest of the member; therefore, it could have higher structural…

Abstract

Purpose

Tapered section can resist maximum stress at a single location while the stresses are considerably lower at the rest of the member; therefore, it could have higher structural efficiency compared to conventional section. It could also satisfy functional requirements while reducing weight and cost in many fields of civil construction. Perforation in the steel section also eases the integration of Mechanical and Electrical (M&E) services such as ventilation pipes and electrical cables within the structural depths of the beam. In this analysis, the structural efficiency of tapered steel section with perforation under lateral-torsional buckling behaviour is investigated.

Design/methodology/approach

A total of 81 models are analysed using LUSAS software and five variables are investigated which involved perforation sizes, perforation shapes, perforation layout, tapering ratio and flange and Web thickness. Buckling moment is obtained from the analysis results in LUSAS software, while self-weight and structural efficiency are manually calculated.

Findings

Perforation size of 0.75 D has the highest structural efficiency, although it can withstand a smaller buckling load. This is due to its lower self-weight compared to other perforation sizes. The square perforation shape also has the highest structural efficiency compared to circular perforation and diamond perforation. An increment of percentage in structural efficiency of the square perforation shape with 0.75 D is the highest at 3.07%. The circular perforation shape with 0.75 D (Open-Open-Open perforation layout) has the highest increment of percentage in structural efficiency which is 2.37%. The tapering ratio of 0.3 is the most efficient and an increment of percentage in structural efficiency is 114.36%. The flange thickness of 0.02 m and Web thickness of 0.015 m has the highest structural efficiency at 45.756 and 29.171, respectively.

Originality/value

In conclusion, a section should be able to resist the large buckling moment and has a lower self-weight to achieve high structural efficiency.

Details

World Journal of Engineering, vol. 17 no. 6
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 7 July 2023

Ala'aldin Al-Hassoun and Rabab Allouzi

Concrete-filled double skin steel tubes (CFDST) columns are taken more attention due to their ability to withstand high structural loads in structures such as high-rise buildings…

Abstract

Purpose

Concrete-filled double skin steel tubes (CFDST) columns are taken more attention due to their ability to withstand high structural loads in structures such as high-rise buildings, bridges' piers, offshore and marine structures. This paper is intended to improve the CFDST column's capacity without the need to increase the column's size to maintain its lightweight by filling it with self-compacted concrete (SCC) containing nanoclay (NC).

Design/methodology/approach

First, experimental investigation is conducted to select the optimal NC percentage that improves the mechanical properties. Different mixing method, mixture ingredients, cement content, and NC percentage are considered. Then, slender and short CFDST columns are tested for axial capacity to investigate the effect of adding the optimum NC percentage on column's capacity and failure mode.

Findings

The test results show that adding 3% NC by cement weight using dry mixing method to SCC is the optimum ratio. It is concluded that adding 3% NC by cement weight increased the CFDST column's capacity, especially the specimens with higher slenderness ratio. Moreover, it is concluded that more specimens should be tested under various geometric and reinforcement details.

Originality/value

Recently, CFDST tube columns solve many structural and architectural problems that engineers have encountered in traditional systems. Therefore, more studies are required to design high-performance columns capable of carrying complex loads with high efficiency since the traditional design could not achieve the required performance. Since concrete contributes to a large portion in the axial capacity of the CFDST columns, it is proposed to improve the CFDST column's capacity without the need to increase the column's size to maintain its lightweight by filling it with (SCC containing NC. Previous research has affirmed the effectiveness of employing nanoclay in the concrete's workability, durability, microstructures, and mechanical properties.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

1 – 10 of 222