Search results

1 – 10 of over 5000
Article
Publication date: 27 March 2020

Yu hui Fan, Pan pan Liu, Bo Shen, Kejian Ma, Bang Wu, Tianhong Zheng and Fang Yang

The reinforced concrete open-web sandwich slab is composed of upper rib, lower rib, surface plate and shear key and was applied to long-span structure crossing at 18–30 m. The…

Abstract

Purpose

The reinforced concrete open-web sandwich slab is composed of upper rib, lower rib, surface plate and shear key and was applied to long-span structure crossing at 18–30 m. The shear-bearing capacity of shear key, having vital effects on the slab’s bearing capacity, is analysed to present its calculation formula used for the engineering application of the slab.

Design/methodology/approach

The shear-bearing capacity of shear key is analysed by the strut-and-tie model and the benchmark model established by the finite element method. Furthermore, the design formula of its shear capacity is given by the parametric analysis of FEM to adjust the result of the strut-and-tie model, using multivariate linear regression analysis of these parameters.

Findings

The calculation result of the benchmark model is compared with those of the strut-and-tie model and the standard formula, which indicates that the result of the strut-and-tie model is closer to that of the benchmark model than that of the standard formula. Moreover, the parametric analysis of the finite element model indicates that the volume–stirrup ratio of the shear key and the compression strength of the concrete have lesser effect on the shear capacity compared with the longitudinal reinforcement ratio and the shear-to-span ratio of the shear key and the relative section height of the rib.

Originality/value

The shear capacity of the shear key is provided in the paper by combining the finite element method and the strut-and-tie model, which is different from the calculation of the shear key in local codes and Chinese code, based on the theory of short corbel and the experiment of member. Furthermore, the formula of the shear capacity could be employed in the design and construction of the RC open-web sandwich slab, mainly used in the public and industrial multi-story building with long span to save the dwindling land resource currently.

Details

International Journal of Structural Integrity, vol. 12 no. 2
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 19 September 2022

Jinliang Liu and Xincheng Su

The effects of failure mode and strain conditions of CFRP, concrete and stirrups on the shear capacity of reinforced beams bonded by geopolymer and epoxy are studied. In addition…

Abstract

Purpose

The effects of failure mode and strain conditions of CFRP, concrete and stirrups on the shear capacity of reinforced beams bonded by geopolymer and epoxy are studied. In addition, a prediction model of the ultimate bearing capacity of CFRP-shear-strengthened beams is proposed, which considers adhesive performance parameters adhesive performance parameter ßE and FRP width parameter ßw.

Design/methodology/approach

This paper presents an experimental study on ultimate bearing capacity of CFRP-shear-strengthened pre-cracked beams with geopolymer and epoxy resin, which considers parameters such as impregnated adhesives types and CFRP-strengthened scheme.

Findings

The failure modes of CFRP-strengthened beams bonded by geopolymer are the combination of the CFRP-concrete interface substrate failure and fracture failure of CFRP, and that of epoxy is the local substrate failures with small area. The ultimate load of CFRP-strengthened beams is directly affected by the failure modes. The ultimate bearing capacity of CFRP-strengthened beams with geopolymer is 91.4% of that of epoxy resin. Compared with ultimate bearing capacity of CFRP-strengthened beams with U-shaped, that of complete-wrapping increases by 2.5%. Moreover, the stirrup peak strain is reduced by more than 30% in CFRP-strengthened beams bonded with geopolymer and epoxy resin in comparison with the unstrengthened beam. The existing prediction model cannot accurately predict the CFRP shear capacity contribution of strengthened beams with different CFRP-strengthened schemes and adhesive properties. The estimated results are much lower than the test data, and the deviation is much larger than 20%.

Originality/value

Geopolymer alternative to epoxy as an adhesive is feasible and effective for CFRP reinforcement. Furthermore, the accuracy is improved by introducing parameters about adhesive properties based on the existing prediction model. The estimated results are in excellent agreement with the test data, and the deviation is controlled within −12.80%, and the model is suitable for predicting the shear capacity of FRP-strengthened beams with ßf = 90° in shear capacity database.

Details

Multidiscipline Modeling in Materials and Structures, vol. 18 no. 5
Type: Research Article
ISSN: 1573-6105

Keywords

Article
Publication date: 29 April 2021

Donia Salman, Rabab Allouzi and Nasim Shatarat

The main goal is to investigate the effect of size and location of opening and column size on the punching shear strength. Openings are often needed in order to install mechanical…

Abstract

Purpose

The main goal is to investigate the effect of size and location of opening and column size on the punching shear strength. Openings are often needed in order to install mechanical and electrical services. This process takes away part of the concrete volume which is responsible for resisting the shear forces and any unbalanced moment. Furthermore, the application of rectangular columns in flat slabs is commonly used in practice as they provide lateral stiffness to the building. They are also utilised in garages and multi-storey buildings where these elongated cross-sectional columns reduce the effective span length between adjacent columns.

Design/methodology/approach

This research is a numerical-based investigation that is calibrated based on a thirteen previously tested and numerically calibrated slab specimens with no openings. A parametric study is conducted in this study to consider the effect of other parameters, which are the size and location of opening and the rectangularity ratio of column in order to evaluate their effect on the punching shear capacity. A total of 156 models are developed to study these factors. Additionally, the predicted shear carrying capacity of the simulated slabs is calculated using the ACI318–19 and Eurocode (EC2-04) equation.

Findings

The presence of openings reduced the punching shear capacity. The small opening's location and orientation have almost no effect except for one slab. For slabs of large openings, the presence of openings reduced the punching capacity. The punching capacity is higher when the openings are farther from the column. The numerically obtained results of slabs with rectangular columns show lower punching capacity compared to slabs of squared columns with the same length of the punching shear control perimeter. The punching capacity for all slabs is predicted by ACI318–19 and Eurocode (EC2-04) and it is found that Eurocode (EC2-04) provided a closer estimation.

Originality/value

The slabs considered for calibration were reinforced with four different punching shear reinforcement configurations, namely; ordinary closed rectangular stirrups, rectangular spiral stirrups, advanced rectangular spiral stirrups and circular spiral. Generally, there has been limited research on concrete flat slabs with openings in comparison with other subjects related to structural engineering (Guan, 2009) and no research on punching shear with openings of slabs reinforced with these reinforcement schemes. The available research focussed on the effects of openings on the flexural behaviour of reinforced concrete slabs includes Casadei et al. (2003), Banu et al. (2012) and Elsayed et al. (2009). In addition, experimental tests that examined slabs supported on rectangular columns are very limited.

Details

International Journal of Structural Integrity, vol. 12 no. 4
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 13 June 2016

Mahmud M.S. Dwaikat

Different approaches, originally developed for ambient conditions, exist in current codes and standards for incorporating the effect of moment–shear (M–V) interaction on the…

Abstract

Purpose

Different approaches, originally developed for ambient conditions, exist in current codes and standards for incorporating the effect of moment–shear (M–V) interaction on the plastic-carrying capacity of wide-flanged (WF) steel sections. There is a lack of experimental and theoretical studies that address this issue under fire conditions.

Design/methodology/approach

The current paper presents a numerical study investigating the effect of fire exposure on the plastic M–V capacity curves of doubly symmetrical, WF, hot-rolled steel sections. Validated high-fidelity finite element (FE) models constructed via ANSYS are used to study the effect M–V interaction on the plastic capacity of WF sections. Also, a simplified plastic sectional analysis, intended to be used by engineering practitioners, is proposed for generating the plastic M–V interaction curves.

Findings

The study shows that the fire-induced non-uniform heating of the section plates affects the shape of the plastic M–V interaction capacity curves. Comparison of different methods against FE results shows that the method specified in the Eurocode is very conservative at room-temperature, but it turns out to be barely sufficiently conservative under fire conditions.

Originality/value

It is well noted that lack of fire tests on the M–V interaction, including the stability of the plates of steel sections under fire, make it difficult to reach a definite assessment on the effect of M–V interaction on the bearing capacity of steel beams.

Details

Journal of Structural Fire Engineering, vol. 7 no. 2
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 25 February 2022

Mojtaba Labibzadeh, Mohsen Bagheri, Abdolghafour Khademalrasoul and Khandaker M.A. Hossain

This paper aims to study, the effects of opening shape, size and position as well as the aspect (height-to-length) ratio on the shear capacity, stiffness, ductility and energy…

Abstract

Purpose

This paper aims to study, the effects of opening shape, size and position as well as the aspect (height-to-length) ratio on the shear capacity, stiffness, ductility and energy dissipation capacity of triple-skin profiled steel-concrete composite shear wall (TSCSW) and investigate and compare them to those of concrete-stiffened steel plate shear walls (CSPSW). Two kinds of opening, circular and square, with different sizes and positions and two aspect ratios of 1:1 and 3:1 are considered in the simulations.

Design/methodology/approach

This study presents a novel TSCSW and compares its behavior with the existing CSPSW under the effect of monotonic and cyclic loadings. TSCSW is composed of three corrugated steel plates filled with concrete. The two external side plates are connected to the concrete core by means of several intermediate fasteners and the third one is an inner steel plate embedded within the concrete panel. The internal plate is a buckling restrained plate surrounded by concrete. This is the main superiority of TSCSW over other kinds of existing composite shear walls.

Findings

The results show that the shear capacity and the energy dissipation capacity of the proposed composite wall, TSCSW, are respectively about 16 and 12% higher than those of CSPSW when there is no opening. If an opening is considered in the wall, as the size of the opening is increased, the shear capacity, stiffness, ductility and absorbed energy of the two walls are decreased similarly. The destructive effect of square openings on the performance of the walls is more than that of circular openings.

Originality/value

This is an original work.

Details

International Journal of Structural Integrity, vol. 13 no. 3
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 1 October 2018

Jiawei Wang, Jinliang Liu, Guanhua Zhang and Yanmin Jia

The calculation of the shear capacity of inclined section for prestressed reinforced concrete beams is an important topic in the design of concrete members. The purpose of this…

Abstract

Purpose

The calculation of the shear capacity of inclined section for prestressed reinforced concrete beams is an important topic in the design of concrete members. The purpose of this paper, based on the truss-arch model, is to analyze the shear mechanism in prestressed reinforced concrete beams and establish the calculation formula for shear capacity.

Design/methodology/approach

Considering the effect of the prestressed reinforcement axial force on the angle of the diagonal struts and regression coefficient of softening cocalculation of shear capacity is established. According to the shape of the cracks of prestressed reinforced concrete beams under shear compression failure, the tie-arch model for the calculation of shear capacity is established. Shear-failure-test beam results are collected to verify the established formula for shear bearing capacity.

Findings

Through theoretical analysis and experimental beam verification, it is confirmed in this study that the truss-arch model can be used to analyze the shear mechanism of prestressed reinforced concrete members accurately. The calculation formula for the angle of the diagonal struts chosen by considering the effect of prestress is accurate. The relationship between the softening coefficient of concrete and strength of concrete that is established is correct. Considering the effect of the destruction of beam shear plasticity of the concrete on the surface crack shape, the tie-arch model, which is established where the arch axis is parabolic, is applicable.

Originality/value

The formula for shear capacity of prestressed reinforced concrete beams based on this theoretical model can guarantee the effectiveness of the calculation results when the structural properties vary significantly. Engineers can calculate the parameters of prestressed reinforced concrete beams by using the shear capacity calculation formula proposed in this paper.

Details

International Journal of Structural Integrity, vol. 9 no. 5
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 30 October 2019

Sheng-cai Li and Guo Lin

The purpose of this paper is to study the seismic performance of the energy-saving block and invisible multi-ribbed frame composite walls (EBIMFCW), changing the shear-span ratio…

Abstract

Purpose

The purpose of this paper is to study the seismic performance of the energy-saving block and invisible multi-ribbed frame composite walls (EBIMFCW), changing the shear-span ratio as the test parameter, the low-cycle reciprocating loading tests of six 1/2 scale wall models were carried out.

Design/methodology/approach

The test design method and analysis are used for the seismic performance of the EBIMFCW.

Findings

With the increase of shear-span ratio: the walls tend to occur bending failure even more, the initial stiffness of the wall decreases, the overall ductility of the wall is improved and the walls tend to occur bending failure.

Originality/value

The previous studies do not involve the seismic performance of EBIMFCW under different shear-span ratios. Therefore, the paper studies the hysteresis behavior, ductility, stiffness degradation and energy dissipation performance of EBIMFCW under different shear-span ratios.

Details

International Journal of Structural Integrity, vol. 11 no. 3
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 1 December 2002

H.Y. Leung

This paper aims to study the effect of external glass fibre reinforced polymer (GFRP) plates on the flexural and shear behaviour of structurally deficient reinforced concrete (RC…

Abstract

This paper aims to study the effect of external glass fibre reinforced polymer (GFRP) plates on the flexural and shear behaviour of structurally deficient reinforced concrete (RC) beams, a total of ten 180mm×250mm×2,500mm beams, including over‐designed, unplated under‐designed and plated under‐designed, were tested under four‐point bending condition. Experimental results indicate that the use of GFRP plates enhances the strength and deformation capacity of RC beams by altering their failure modes. Application of side plates on shear‐deficient RC beams appears to be more effective than using bottom plates on flexure‐deficient RC beams. However, without any improvement of concrete compressive capacity, additional shear capacities provided to the beams under the action of side plates increase the likelihood of beam failure by concrete crushing. Simultaneous use of bottom and side plates on flexural‐ and shear‐deficient RC beams may result in reduced deflection.

Details

Structural Survey, vol. 20 no. 5
Type: Research Article
ISSN: 0263-080X

Keywords

Article
Publication date: 1 June 2022

Fatimah De'nan, Nor Salwani Hashim and Xing Yong Sua

With the vast advancement of structural steel properties over the recent decades, structural steel has become the dominate material for the construction of bridges, stadiums…

Abstract

Purpose

With the vast advancement of structural steel properties over the recent decades, structural steel has become the dominate material for the construction of bridges, stadiums, factories and high rise buildings. This paper aims to present the study of structural behaviour and efficiency of tapered steel section with elliptical perforation under shear loading conditions.

Design/methodology/approach

The effect of various elliptical perforation configurations such as tapering ratio, perforation size, perforation orientation and perforation layout on the shear behaviour of tapered steel section has been investigated by using finite element method. A total of 112 models are simulated via LUSAS software.

Findings

It has been found that the most efficient model is the tapered steel section with tapering ratio of 0.3 and vertical elliptical perforation of 0.2 times the section depths which are arranged in Layout 3. The most efficient model has a shear efficiency of 1,094.35 kN, which is 4.12% less than the tapered steel section without perforation, but it could achieve a 0.32% of weight reduction.

Originality/value

The smaller tapering ratio and perforation size contributed to the higher shear buckling capacity and efficiency for the elliptical perforated tapered steel section.

Details

World Journal of Engineering, vol. 20 no. 6
Type: Research Article
ISSN: 1708-5284

Keywords

Open Access
Article
Publication date: 14 August 2017

Venkatesh Kodur and Mohannad Z. Naser

This purpose of this paper is to quantify the effect of local instability arising from high shear loading on response of steel girders subjected to fire conditions.

1487

Abstract

Purpose

This purpose of this paper is to quantify the effect of local instability arising from high shear loading on response of steel girders subjected to fire conditions.

Design/methodology/approach

A three-dimensional nonlinear finite element model able to evaluate behavior of fire-exposed steel girders is developed. This model, is capable of predicting fire response of steel girders taking into consideration flexural, shear and deflection limit states.

Findings

Results obtained from numerical studies show that shear capacity can degrade at a higher pace than flexural capacity under certain loading scenarios, and hence, failure can result from shear effects prior to attaining failure in flexural mode.

Originality/value

The developed model is unique and provides valuable insight (and information) to the fire response of typical hot-rolled steel girder subjected to high shear loading.

Details

PSU Research Review, vol. 1 no. 2
Type: Research Article
ISSN: 2399-1747

Keywords

1 – 10 of over 5000