Publication date: 18 March 2024

Lifeng Wang, Fei Yu, Ziwang Xiao and Qi Wang

When the reinforced concrete beams are reinforced by bonding steel plates to the bottom, excessive use of steel plates will make the reinforced concrete beams become super…

Abstract

Purpose

When the reinforced concrete beams are reinforced by bonding steel plates to the bottom, excessive use of steel plates will make the reinforced concrete beams become super-reinforced beams, and there are security risks in the actual use of super-reinforced beams. In order to avoid the occurrence of this situation, the purpose of this paper is to study the calculation method of the maximum number of bonded steel plates to reinforce reinforced concrete beams.

Design/methodology/approach

First of all, when establishing the limit failure state of the reinforced member, this paper comprehensively considers the role of the tensile steel bar and steel plate and takes the load effect before reinforcement as the negative contribution of the maximum number of bonded steel plates that can be used for reinforcement. Through the definition of the equivalent tensile strength, equivalent elastic modulus and equivalent yield strain of the tensile steel bar and steel plate, a method to determine the relative limit compression zone height of the reinforced member is obtained. Second, based on the maximum ratio of (reinforcement + steel plate), the relative limit compression zone height and the equivalent tensile strength of the tensile steel bar and steel plate of the reinforced member, the calculation method of the maximum number of bonded steel plates is derived. Then, the static load test of the test beam is carried out and the corresponding numerical model is established, and the reliability of the numerical model is verified by comparison. Finally, the accuracy of the calculation method of the maximum number of bonded steel plates is proved by the numerical model.

Findings

The numerical simulation results show that when the steel plate width is 800 mm and the thickness is 1–4 mm, the reinforced concrete beam has a delayed yield platform when it reaches the limit state, and the failure mode conforms to the basic stress characteristics of the balanced-reinforced beam. When the steel plate thickness is 5–8 mm, the sudden failure occurs without obvious warning when the reinforced concrete beam reaches the limit state. The failure mode conforms to the basic mechanical characteristics of the super-reinforced beam failure, and the bending moment of the beam failure depends only on the compressive strength of the concrete. The results of the calculation and analysis show that the maximum number of bonded steel plates for reinforced concrete beams in this experiment is 3,487 mm2. When the width of the steel plate is 800 mm, the maximum thickness of the steel plate can be 4.36 mm. That is, when the thickness of the steel plate, the reinforced concrete beam is still the balanced-reinforced beam. When the thickness of the steel plate, the reinforced concrete beam will become a super-reinforced beam after reinforcement. The calculation results are in good agreement with the numerical simulation results, which proves the accuracy of the calculation method.

Originality/value

This paper presents a method for calculating the maximum number of steel plates attached to the bottom of reinforced concrete beams. First, based on the experimental research, the failure mode of reinforced concrete beams with different number of steel plates is simulated by the numerical model, and then the result of the calculation method is compared with the result of the numerical simulation to ensure the accuracy of the calculation method of the maximum number of bonded steel plates. And the study does not require a large number of experimental samples, which has a certain economy. The research result can be used to control the number of steel plates in similar reinforcement designs.

Details

International Journal of Structural Integrity, vol. 15 no. 2
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 1 October 2003

H.Y. Leung and R.V. Balendran

Use of fibre‐reinforced polymer (FRP) composite rods, in lieu of steel rebars, as the main flexural reinforcements in reinforced concrete (RC) beams have recently been suggested…

2656

Abstract

Use of fibre‐reinforced polymer (FRP) composite rods, in lieu of steel rebars, as the main flexural reinforcements in reinforced concrete (RC) beams have recently been suggested by many researchers. However, the development of FRP RC beam design is still stagnant in the construction industry and this may be attributed to a number of reasons such as the high cost of FRP rods compared to steel rebars and the reduced member ductility due to the brittleness of FRP rods. To resolve these problems, one of the possible methods is to adopt both FRP rods and steel rebars to internally reinforce the concrete members. The effectiveness of this new reinforcing system remains problematic and continued research in this area is needed. An experimental study on the load‐deflection behaviour of concrete beams internally reinforced with glass fibre‐reinforced polymer (GFRP) rods and steel rebars was therefore conducted and some important findings are summarized in this paper.

Details

Structural Survey, vol. 21 no. 4
Type: Research Article
ISSN: 0263-080X

Keywords

Article
Publication date: 27 April 2022

Nadia Talbi, Aghiles Nekmouche, Mohand Ould Ouali, Naceur-Eddine Hannachi and Mohammed Naboussi Farsi

This paper aims to model the performances of frames structures by comparing the predictions of ordinary control concrete (CC) and concretes reinforced by fibers. Two types of steel

Abstract

Purpose

This paper aims to model the performances of frames structures by comparing the predictions of ordinary control concrete (CC) and concretes reinforced by fibers. Two types of steel fibers were used in this work, industrial steel fibers (ISF) and tire-reclaimed fibers obtained by cutting virgin steel tire-cord to 50 mm, noticed virgin steel fibers (VSF). In total, 3% of VSF are used. The results obtained in this paper clearly show the contribution of fibers in improving the global and local behavior of the frames structures. VSF gives the same or better overall behavior as the use of industrial fibers for the same percentage of fibers, with the advantage that VSF contributes to the protection of the environment and limit the wastage of steel.

Design/methodology/approach

This work was carried out using the commercial finite element code Abaqus/Explicit. The behavior of the different concretes used in this study was modeled by the concrete damage plasticity (CDP) constitutive law. The methodology adopted to complete this work consisted in identifying, by calibration of the available experimental results with the numerical predictions, the parameters of the corresponding CDP model for each of the concretes used in this work. To this end, the authors have successively identified the CDP parameters for the CC-V (control concrete used by Vecchio and Emara, 1992) used in frame structure (R + 1). Subsequently, the CDP parameters of the CC-T (control concrete used by Tlemat, 2004), the CVSF (concrete with virgin steel fibers) and the CISF-1 (concrete with industrial steel fibers type 1, ISF-1) are identified using the experimental results of beams under bending tests. Once the model parameters were determined for each concrete, the authors conducted a series of simulations to show the benefit of introducing claimed and industrial fibers in frame structure (R + 1) and (R + 2). This approach recommends the use of concrete reinforced with steel fibers, mainly 6% by mass of VSF and ISF-1, in place of ordinary concrete in new construction to increase the resistance of structures and contribute, if applicable, to the protection of the environment.

Findings

The main findings of this study can be summarized by: the strength and ductility of the frames structures made of concrete fiber are significantly increased. The use of tire-reclaimed steel fibers (VSF) gives the same or better overall behavior as the use of industrial fibers. In addition to their good mechanical contribution, the tire-reclaimed fibers contribute to the protection of the environment and limit the wastage of steel. The use of fibers reduces the cracking zones in concrete fiber frames structures. The usefulness of distinguishing the interstory displacement limits set by codes, in particular, uniform building code (UBC-97), for ordinary concretes and concrete reinforced with fibers is addressed.

Originality/value

The contribution of tire-reclaimed and industrial fibers on the strength and ductility of reinforced concrete-frames structures is addressed. The use of tire-reclaimed steel fibers gives the same or better overall behavior as the use of industrial fibers, the tire-reclaimed fibers having the advantage of contributing to the protection of the environment and limiting the wastage of steel. The paper also points to the usefulness of distinguishing the interstory displacement limits set by codes, in particular UBC-97, for ordinary concrete and concrete reinforced with fibers, in accordance to the predictions of the capacity curves.

Details

World Journal of Engineering, vol. 20 no. 5
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 28 March 2022

Konstantinos F. Koulouris and Charis Apostolopoulos

As it is widely known, corrosion constitutes a major deterioration factor for reinforced concrete (RC) structures which are located on coastal areas. This phenomenon combined with…

Abstract

Purpose

As it is widely known, corrosion constitutes a major deterioration factor for reinforced concrete (RC) structures which are located on coastal areas. This phenomenon combined with repeated loads, as earthquake events, negatively affects their service life. Moreover, microstructure of steel reinforcing bars has significant impact either on their corrosion resistance or on their fatigue life.

Design/methodology/approach

In the present manuscript an effort has been made to investigate the effect of corrosive factor on fatigue response for two types of steel reinforcement; Tempcore steel reinforcing bars and a new generation dual phase (DP) steel reinforcement.

Findings

The findings of this experimental study showed that DP steel reinforcement led to better results regarding its capacity to bear repeated loads to satisfactory degree after corrosion, although this type of steel has less stringent mechanical properties.

Originality/value

Additionally, a fatigue damage material indicator is proposed as a parameter that could rank material quality and its suitability for a certain application. The results of this investigation showed that the fatigue damage indicator can be used as an appropriate index in order to evaluate the overall performance of materials, in terms of strength and ductility capacity.

Details

International Journal of Structural Integrity, vol. 13 no. 4
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 9 April 2024

Long Liu, Lifeng Wang and Ziwang Xiao

The combination of an Engineered Cementitious Composite (ECC) layer and steel plate to reinforce RC beams (ESRB) is a new strengthening method. The ESRB was proposed based on the…

Abstract

Purpose

The combination of an Engineered Cementitious Composite (ECC) layer and steel plate to reinforce RC beams (ESRB) is a new strengthening method. The ESRB was proposed based on the steel plate at the bottom of RC beams, aiming to solve the problem of over-reinforced RC beams and improve the bearing capacity of RC beams without affecting their ductility.

Design/methodology/approach

In this paper, the finite element model of ESRB was established by ABAQUS. The results were compared with the experimental results of ESRB in previous studies and the reliability of the finite element model was verified. On this basis, parameters such as the width of the steel plate, thickness of the ECC layer, damage degree of the original beam and cross-sectional area of longitudinal tensile rebar were analyzed by the verified finite element model. Based on the load–deflection curve of ESRB, ESRB was discussed in terms of ultimate bearing capacity and ductility.

Findings

The results demonstrate that when the width of the steel plate increases, the ultimate load of ESRB increases to 133.22 kN by 11.58% as well as the ductility index increases to 2.39. With the increase of the damage degree of the original beam, the ultimate load of ESRB decreases by 23.7%–91.09 kN and the ductility index decreases to 1.90. With the enhancement of the cross-sectional area of longitudinal tensile rebar, the ultimate bearing capacity of ESRB increases to 126.75 kN by 6.2% and the ductility index elevates to 2.30. Finally, a calculation model for predicting the flexural capacity of ESRB is proposed. The calculated results of the model are in line with the experimental results.

Originality/value

Based on the comparative analysis of the test results and numerical simulation results of 11 test beams, this investigation verified the accuracy and reliability of the finite element simulation from the aspects of load–deflection curve, characteristic load and failure mode. Furthermore, based on load–deflection curve, the effects of steel plate width, ECC layer thickness, damage degree of the original beam and cross-sectional area of longitudinal tensile rebar on the ultimate bearing capacity and ductility of ESRB were discussed. Finally, a simplified method was put forward to further verify the effectiveness of ESRB through analytical calculation.

Details

International Journal of Structural Integrity, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 24 May 2013

Ch. Alk. Apostolopoulos and Vassilios Kappatos

The corrosion of reinforcing steel bars reduces significantly the life and durability of concrete structures. This critical concern causes great losses to the economy and…

Abstract

Purpose

The corrosion of reinforcing steel bars reduces significantly the life and durability of concrete structures. This critical concern causes great losses to the economy and industry. The purpose of this paper is to estimate the effects of corrosion on the tensile mechanical properties of embedded steel bars B500c in concrete.

Design/methodology/approach

The concept is based on the curve fitting modelling, as well the mathematical correlation of the tensile mechanical properties between corroded bare and corroded embedded steel bars. In order to achieve this, extensive experiments were carried out on both bare (Ø8, 10, 12, 16 and 18 mm) and embedded (Ø8 mm) steel bars B500c, which were subjected to artificially accelerated corrosive conditions in a chloride‐rich atmosphere for several exposure times.

Findings

The research results show that the estimation method is available and effective in simulating the tensile mechanical behaviour of corroded reinforcing steel bars B500c.

Originality/value

As far as is known, this is the first time that an advanced data processing technique has been employed to try to find the mathematical correlation of the existing corrosion damage on the residual tensile properties between bare and embedded steel bars. It is argued that these models can be developed in order to reduce the need for expensive experimental investigation in materials.

Details

International Journal of Structural Integrity, vol. 4 no. 2
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 5 February 2018

Charis Apostolopoulos, George Konstantopoulos and Konstantinos Koulouris

Structures in seismic areas, during their service lifetime, are subjected to numerous seismic loads that certainly affect their structural integrity. The degradation of these…

Abstract

Purpose

Structures in seismic areas, during their service lifetime, are subjected to numerous seismic loads that certainly affect their structural integrity. The degradation of these structures, to a great extent, depends on the scale of seismic events, the steel mechanical performance on reversal loads and its resistance to corrosion phenomena. The paper aims to discuss these issues.

Design/methodology/approach

Based on the experimental results of seismic steel behavior S400 (BSt III), which was widely used in the past years, a prediction study of seismic steel behavior was conducted in the current study. This prediction on behavior of both reference and corroded steel was succeeded through a simulation of experimental low cycle fatigue conditions (LCF – strain controlled).

Findings

At the same time, the present study analyses fatigue factors (ef, a, fSR, ed, ep, R, b) that define their inelastic relation between tension – strain and a prediction model on behavior of both reference and corroded steel rebar, in seismic loads conditions (LCF), is proposed.

Originality/value

Moreover, this study dealt with the synergy of corrosion factor and the existence of superficial ribs (ribbed and smoothed) in seismic behavior of steel bar S400 (BSt420). The S-N curves that are exported can be resulted in a first attempt of prediction of anti-seismic behavior on reinforced concrete structures with this the same steel class.

Details

International Journal of Structural Integrity, vol. 9 no. 1
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 1 January 2014

Guofu Qiao, Yi Hong, Tiejun Liu and Jinping Ou

The aim of this paper was to investigate the passive corrosion control and active corrosion protective effect of the reinforced concrete structures by electrochemical chloride…

Abstract

Purpose

The aim of this paper was to investigate the passive corrosion control and active corrosion protective effect of the reinforced concrete structures by electrochemical chloride removal (ECR) method and inhibitors approach, respectively.

Design/methodology/approach

The concentration of aggressive chloride ion distributed from the reinforcing steel to the surface of the concrete cover was analyzed during the ECR processes. Besides, the half-cell potential, the concrete resistance R c , the polarization resistance R p and the capacitance of double layer C dl of the steel/concrete system were used to characterize the electrochemical performance of the concrete prisms.

Findings

The effectiveness of ECR could be enhanced by increasing the amplitude of potential or prolonging the time. Inhibitor SBT-ZX(I) could successfully prevent the corrosion development of the reinforcing steel in concrete.

Originality/value

The research provides the scientific basis for the practical application of ECR and inhibitors in the field.

Details

Anti-Corrosion Methods and Materials, vol. 61 no. 1
Type: Research Article
ISSN: 0003-5599

Keywords

Article
Publication date: 1 July 1992

Adel El‐Kurdey and Ashraf Y. Hosny

The corrosion of reinforcing steel is considered the most critical problem for the durability of reinforced concrete structures. This study shows the experimental results of the…

Abstract

The corrosion of reinforcing steel is considered the most critical problem for the durability of reinforced concrete structures. This study shows the experimental results of the corrosion of steel bars in mortar, using an accelerated test. The results indicate that increasing water/cement ratios accelerate the corrosion of reinforcing steel. In addition, increasing curing times decrease steel corrosion rates. The results also show that the cover to bar diameter ratio plays a significant role in determining the corrosion intensity. For the same cover thickness, the corrosion intensity increases as the steel bar diameter increases.

Details

Anti-Corrosion Methods and Materials, vol. 39 no. 7
Type: Research Article
ISSN: 0003-5599

Article
Publication date: 1 August 2006

A.E. Richardson and C. Fallow

To evaluate manufacturers' claims that structural polypropylene fibres provide satisfactory crack control reinforcement and compare the findings against steel fabric used as crack…

Abstract

Purpose

To evaluate manufacturers' claims that structural polypropylene fibres provide satisfactory crack control reinforcement and compare the findings against steel fabric used as crack control in screeds where tensile forces are likely to occur.

Design/methodology/approach

The procedure used to provide load, deflection data, toughness indices and residual strength factors was compliant with ASTM C1018‐97 and in part ASTM C78‐02 to define first crack toughness and first crack strength.

Findings

A142 steel fabric reinforcement as used in screeds was more effective in producing toughness and residual strength when directly compared with the performance of structural polypropylene fibre reinforced concrete. Where polypropylene fibre reinforced concrete did have an advantage over the steel reinforced concrete was when I20 was exceeded and the deflection and crack width was excessive. Steel fabric tended to fail and/or the screed material failed either prior to or in excess of I20, whereas the fibre reinforced concrete held together albeit at a very much reduced load transfer when compared with steel fabric.

Practical implications

If the forces to be encountered through expansion or contraction are small, then, due to the small distances between the fibres redistributing the stress and minimising the cracks within the concrete matrix, polypropylene fibres may be suitable for crack control when directly compared with A142 fabric reinforcement. The use of fibres has benefits to the floor screed companies, using screed‐laying machines as the process avoids laying steel on which the screed machine will have to operate.

Originality/value

There is a general lack of research coverage examining crack control in screed floor finishing materials.

Details

Structural Survey, vol. 24 no. 4
Type: Research Article
ISSN: 0263-080X

Keywords