Shufeng Li, Di Zhao and Yating Zhou

Concrete-filled steel tube structures are widely used for their high bearing capacity, good plasticity, good fire resistance and optimal seismic performance. In order to give full…

Abstract

Purpose

Concrete-filled steel tube structures are widely used for their high bearing capacity, good plasticity, good fire resistance and optimal seismic performance. In order to give full play to the advantages of concrete-filled steel tube, this paper proposes a prefabricated concrete-filled steel tube frame joint.

Design/methodology/approach

The concrete-filled steel tube column and beam are connected by high-strength bolted end-plate, and the steel bars in the concrete beam are welded vertically with the end-plates through the enlarged pier head. In addition, the finite element software ABAQUS is used numerically to study the seismic performance of the structure.

Findings

The ductility coefficient of the joint is in 1.72–6.82, and greater than 2.26 as a whole. The equivalent viscous damping coefficient of the joint is 0.13–3.03, indicating that the structure has good energy dissipation capacity.

Originality/value

The structure is convenient for construction and overcomes the shortcomings of the previous on-site welding and on-site concrete pouring. The high-strength bolted end-plate connection can effectively transfer the load, and each component can give play to its material characteristics.

Details

International Journal of Structural Integrity, vol. 13 no. 2
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 10 January 2018

Oliver Bahr

The purpose of this study is to gain a deeper understanding of the structural behaviour of fire-exposed unbraced composite frames. Designers to date paid little attention to…

Abstract

Purpose

The purpose of this study is to gain a deeper understanding of the structural behaviour of fire-exposed unbraced composite frames. Designers to date paid little attention to unbraced one-bay composite frames as structural system. There are two main reasons for this. First, codes lack simplified methods for the fire design of these frames due to their sway and the linked P-Δ effects when subjected to fire, which complicates the design. Second, it is demanding to construct external composite joints for the regarded one-bay frames. Thus, external joints in composite constructions are mostly constructed as steel joints. Nevertheless, these frames offer advantages. These include increased usable space and flexibility in the building’s use, large spans, fast construction times and inherent fire resistance.

Design/methodology/approach

To profit from these benefits, two different external semi-rigid composite joint were developed for the considered one-bay composite frames. The first solution based on concrete-filled steel tube columns and the second on concrete-filled double skin tube columns. Furthermore, a numerical model was established to study the fire performance of unbraced composite frames. The model was validated against four fire tests on isolated composite joints and two large-scale fire tests on unbraced composite frames.

Findings

Overall, the predictions of the numerical model were in good agreement with the test results. Thus, the numerical model is appropriate for further investigations on the fire performance of unbraced composite frames.

Originality/value

The sequence of construction results in significant stresses in the steel section, which creates difficulties in numerical modelling and may account for the relatively few studies carried out at room temperature. For the fire design, there was, to the best knowledge of the author, to date no numerical model available that was capable of considering the sequence of construction.

Details

Journal of Structural Fire Engineering, vol. 9 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 14 July 2020

Shufeng Li, Le Deng and Zhao Di

The purpose of this study is to put forward a high-strength bolt end-plate connection of prefabricated concrete beam-column joint and carry out the pseudo-static test.

Abstract

Purpose

The purpose of this study is to put forward a high-strength bolt end-plate connection of prefabricated concrete beam-column joint and carry out the pseudo-static test.

Design/methodology/approach

ABAQUS finite element software is used to study the fire resistance performance of high-strength bolt end-plate prefabricated joint. This mainly considers the influence of axial compression ratio, screw preload, end-plate thickness and steel hoop thickness.

Findings

The results show that the thickness of end-plate and steel hoop has a certain effect on the fire resistance. The change of screw preload has little effect on the fire resistance limit. Compared with the cast-in-place concrete beam-column joint, the deformation trend of column-beam end of the fabricated joint is basically the same as that of cast-in-place joint.

Originality/value

To study the mechanical performance of this kind of joint more comprehensively, the finite element software is used to study the prefabricated concrete beam-column joint with end-plates, and the effects of axial compression ratio, screw preload, end-plate thickness and steel hoop thickness on the fire resistance of joints are mainly considered.

Details

Journal of Structural Fire Engineering, vol. 11 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 8 June 2021

Shufeng Li, Zhang Jiaolei, Di Zhao and Le Deng

This study aims to further study the fire resistance of prefabricated concrete beam-column joints with end-plate connection. This paper aims to analyze the fire resistance of this…

Abstract

Purpose

This study aims to further study the fire resistance of prefabricated concrete beam-column joints with end-plate connection. This paper aims to analyze the fire resistance of this joint in prefabricated reinforced concrete frame structure (PRCS).

Design/methodology/approach

First, the accuracy of the model is verified by using the test data. Based on this, a refined finite element model of PRCS structure with two stories and two spans is established. The influence of four working conditions with different fire floors (positions) and different axial compression ratios on the deformation, failure and fire resistance of PRCS structure are analyzed.

Findings

The results show that under the four working conditions, the fire resistance of the PRCS structure under Condition 1 and Condition 2 is smaller. It shows that the beam deformation develops slowly in PRCS structure under four kinds of fire positions, and the large displacement emerges 60 min later, which is poles apart from that of prefabricated beam column members. With the increase of the fire time, the material is damaged and deteriorated, which leads to the eccentricity of the axial load, so that the column top appears large lateral displacement. Under the Conditions 1 and 3, the lateral displacement of the column gradually decreases as the axial compression ratio rises.

Originality/value

It is found that there is a distinct lack of researching on the fire resistance of prefabricated joints, and the existed research studies are limited to the fire resistance of members. Thus, it is necessary to strengthen the first floor and side column design of prefabricated frame structure.

Details

Journal of Structural Fire Engineering, vol. 12 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 17 January 2022

Irindu Upasiri, Chaminda Konthesingha, Anura Nanayakkara, Keerthan Poologanathan, Gatheeshgar Perampalam and Dilini Perera

Light-Gauge Steel Frame (LSF) structures are popular in building construction due to their lightweight, easy erecting and constructability characteristics. However, due to steel

Abstract

Purpose

Light-Gauge Steel Frame (LSF) structures are popular in building construction due to their lightweight, easy erecting and constructability characteristics. However, due to steel lipped channel sections negative fire performance, cavity insulation materials are utilized in the LSF configuration to enhance its fire performance. The applicability of lightweight concrete filling as cavity insulation in LSF and its effect on the fire performance of LSF are investigated under realistic design fire exposure, and results are compared with standard fire exposure.

Design/methodology/approach

A Finite Element model (FEM) was developed to simulate the fire performance of Light Gauge Steel Frame (LSF) walls exposed to realistic design fires. The model was developed utilising Abaqus subroutine to incorporate temperature-dependent properties of the material based on the heating and cooling phases of the realistic design fire temperature. The developed model was validated with the available experimental results and incorporated into a parametric study to evaluate the fire performance of conventional LSF walls compared to LSF walls with lightweight concrete filling under standard and realistic fire exposures.

Findings

Novel FEM was developed incorporating temperature and phase (heating and cooling) dependent material properties in simulating the fire performance of structures exposed to realistic design fires. The validated FEM was utilised in the parametric study, and results exhibited that the LSF walls with lightweight concrete have shown better fire performance under insulation and load-bearing criteria in Eurocode parametric fire exposure. Foamed Concrete (FC) of 1,000 kg/m3 density showed best fire performance among lightweight concrete filling, followed by FC of 650 kg/m3 and Autoclaved Aerated Concrete (AAC) 600 kg/m3.

Research limitations/implications

The developed FEM is capable of investigating the insulation and load-bearing fire ratings of LSF walls. However, with the availability of the elevated temperature mechanical properties of the LSF wall, materials developed model could be further extended to simulate the complete fire behaviour.

Practical implications

LSF structures are popular in building construction due to their lightweight, easy erecting and constructability characteristics. However, due to steel-lipped channel sections negative fire performance, cavity insulation materials are utilised in the LSF configuration to enhance its fire performance. The lightweight concrete filling in LSF is a novel idea that could be practically implemented in the construction, which would enhance both fire performance and the mechanical performance of LSF walls.

Originality/value

Limited studies have investigated the fire performance of structural elements exposed to realistic design fires. Numerical models developed in those studies have considered a similar approach as models developed to simulate standard fire exposure. However, due to the heating phase and the cooling phase of the realistic design fires, the numerical model should incorporate both temperature and phase (heating and cooling phase) dependent properties, which was incorporated in this study and validated with the experimental results. Further lightweight concrete filling in LSF is a novel technique in which fire performance was investigated in this study.

Details

Journal of Structural Fire Engineering, vol. 13 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 14 June 2019

Abdurra’uf M. Gora, Jayaprakash Jaganathan, M.P. Anwar and H.Y. Leung

Advanced fibre-reinforced polymer (FRP) composites have been increasingly used over the past two decades for strengthening, upgrading and restoring degraded civil engineering…

Abstract

Purpose

Advanced fibre-reinforced polymer (FRP) composites have been increasingly used over the past two decades for strengthening, upgrading and restoring degraded civil engineering infrastructure. Substantial experimental investigations have been conducted in recent years to understand the compressive behaviour of FRP-confined concrete columns. A considerable number of confinement models to predict the compressive behaviour of FRP-strengthened concrete columns have been developed from the results of these experimental investigations. The purpose of this paper is to present a comprehensive review of experimental investigations and theoretical models of circular and non-circular concrete columns confined with FRP reinforcement.

Design/methodology/approach

The paper reviews previous experimental test results on circular and non-circular concrete columns confined with FRP reinforcement under concentric and eccentric loading conditions and highlights the behaviour and mechanics of FRP confinement in these columns. The paper also reviews existing confinement models for concrete columns confined with FRP composites in both circular and non-circular sections.

Findings

This paper demonstrates that the performance and effectiveness of FRP confinement in concrete columns have been extensively investigated and proven effective in enhancing the structural performance and ductility of strengthened columns. The strength and ductility enhancement depend on the number of FRP layers, concrete compressive strength, corner radius for non-circular columns and intensity of load eccentricity for eccentrically loaded columns. The impact of existing theoretical models and directions for future research are also presented.

Originality/value

Potential researchers will gain insight into existing experimental and theoretical studies and future research directions.

Details

World Journal of Engineering, vol. 16 no. 4
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 30 October 2019

Sheng-cai Li and Guo Lin

The purpose of this paper is to study the seismic performance of the energy-saving block and invisible multi-ribbed frame composite walls (EBIMFCW), changing the shear-span ratio…

Abstract

Purpose

The purpose of this paper is to study the seismic performance of the energy-saving block and invisible multi-ribbed frame composite walls (EBIMFCW), changing the shear-span ratio as the test parameter, the low-cycle reciprocating loading tests of six 1/2 scale wall models were carried out.

Design/methodology/approach

The test design method and analysis are used for the seismic performance of the EBIMFCW.

Findings

With the increase of shear-span ratio: the walls tend to occur bending failure even more, the initial stiffness of the wall decreases, the overall ductility of the wall is improved and the walls tend to occur bending failure.

Originality/value

The previous studies do not involve the seismic performance of EBIMFCW under different shear-span ratios. Therefore, the paper studies the hysteresis behavior, ductility, stiffness degradation and energy dissipation performance of EBIMFCW under different shear-span ratios.

Details

International Journal of Structural Integrity, vol. 11 no. 3
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 29 October 2020

Ting Luo, Xiaolong Xue, Yongtao Tan, Yuna Wang and Yuanxin Zhang

This paper aimed to introduce a systematic body of knowledge via a scientometric review, guiding the sustainable transition from conventional construction to prefabricated

1596

Abstract

Purpose

This paper aimed to introduce a systematic body of knowledge via a scientometric review, guiding the sustainable transition from conventional construction to prefabricated construction. The construction industry currently faces a challenge to balance sustainable development and the construction of new buildings. In this context, one of the most recent debates is prefabricated construction. As an emerging construction approach, although existing knowledge makes contributions to the implementation of prefabricated construction, there is a lack of a comprehensive and in-depth overview of the critical knowledge themes and gaps.

Design/methodology/approach

This study uses the scientometric analysis to review the state-of-the-art knowledge of prefabricated construction. It retrieved data from the Web of Science core collection database. CiteSpace software was used to conduct the analysis and visualization; three analysis methods identify the knowledge hotspots, knowledge domains and knowledge topics. Finally, according to integrating the hidden connections among results, a body of knowledge for prefabricated construction application can be inferred.

Findings

The results show that 120 knowledge hotspots, five critical knowledge domains and five prominent knowledge topics are vital for promoting implementation of prefabricated construction. Based on the afore analysis, a body of knowledge for prefabricated construction that can systematically cover a broad knowledge of prefabricated construction-related research and activities are integrated and proposed in this paper.

Originality/value

Body of knowledge systematically covers a broad knowledge of prefabricated construction applications and is vital to guide researchers and practitioners to conduct related research and activities, thereby promoting the sustainable transition to prefabricated construction implementation.

Details

Engineering, Construction and Architectural Management, vol. 28 no. 9
Type: Research Article
ISSN: 0969-9988

Keywords

Article
Publication date: 18 March 2024

Lifeng Wang, Fei Yu, Ziwang Xiao and Qi Wang

When the reinforced concrete beams are reinforced by bonding steel plates to the bottom, excessive use of steel plates will make the reinforced concrete beams become…

Abstract

Purpose

When the reinforced concrete beams are reinforced by bonding steel plates to the bottom, excessive use of steel plates will make the reinforced concrete beams become super-reinforced beams, and there are security risks in the actual use of super-reinforced beams. In order to avoid the occurrence of this situation, the purpose of this paper is to study the calculation method of the maximum number of bonded steel plates to reinforce reinforced concrete beams.

Design/methodology/approach

First of all, when establishing the limit failure state of the reinforced member, this paper comprehensively considers the role of the tensile steel bar and steel plate and takes the load effect before reinforcement as the negative contribution of the maximum number of bonded steel plates that can be used for reinforcement. Through the definition of the equivalent tensile strength, equivalent elastic modulus and equivalent yield strain of the tensile steel bar and steel plate, a method to determine the relative limit compression zone height of the reinforced member is obtained. Second, based on the maximum ratio of (reinforcement + steel plate), the relative limit compression zone height and the equivalent tensile strength of the tensile steel bar and steel plate of the reinforced member, the calculation method of the maximum number of bonded steel plates is derived. Then, the static load test of the test beam is carried out and the corresponding numerical model is established, and the reliability of the numerical model is verified by comparison. Finally, the accuracy of the calculation method of the maximum number of bonded steel plates is proved by the numerical model.

Findings

The numerical simulation results show that when the steel plate width is 800 mm and the thickness is 1–4 mm, the reinforced concrete beam has a delayed yield platform when it reaches the limit state, and the failure mode conforms to the basic stress characteristics of the balanced-reinforced beam. When the steel plate thickness is 5–8 mm, the sudden failure occurs without obvious warning when the reinforced concrete beam reaches the limit state. The failure mode conforms to the basic mechanical characteristics of the super-reinforced beam failure, and the bending moment of the beam failure depends only on the compressive strength of the concrete. The results of the calculation and analysis show that the maximum number of bonded steel plates for reinforced concrete beams in this experiment is 3,487 mm2. When the width of the steel plate is 800 mm, the maximum thickness of the steel plate can be 4.36 mm. That is, when the thickness of the steel plate, the reinforced concrete beam is still the balanced-reinforced beam. When the thickness of the steel plate, the reinforced concrete beam will become a super-reinforced beam after reinforcement. The calculation results are in good agreement with the numerical simulation results, which proves the accuracy of the calculation method.

Originality/value

This paper presents a method for calculating the maximum number of steel plates attached to the bottom of reinforced concrete beams. First, based on the experimental research, the failure mode of reinforced concrete beams with different number of steel plates is simulated by the numerical model, and then the result of the calculation method is compared with the result of the numerical simulation to ensure the accuracy of the calculation method of the maximum number of bonded steel plates. And the study does not require a large number of experimental samples, which has a certain economy. The research result can be used to control the number of steel plates in similar reinforcement designs.

Details

International Journal of Structural Integrity, vol. 15 no. 2
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 11 May 2020

Arka Ghosh, David John Edwards, M. Reza Hosseini, Riyadh Al-Ameri, Jemal Abawajy and Wellington Didibhuku Thwala

This research paper adopts the fundamental tenets of advanced technologies in industry 4.0 to monitor the structural health of concrete beam members using cost-effective…

Abstract

Purpose

This research paper adopts the fundamental tenets of advanced technologies in industry 4.0 to monitor the structural health of concrete beam members using cost-effective non-destructive technologies. In so doing, the work illustrates how a coalescence of low-cost digital technologies can seamlessly integrate to solve practical construction problems.

Design/methodology/approach

A mixed philosophies epistemological design is adopted to implement the empirical quantitative analysis of “real-time” data collected via sensor-based technologies streamed through a Raspberry Pi and uploaded onto a cloud-based system. Data was analysed using a hybrid approach that combined both vibration-characteristic-based method and linear variable differential transducers (LVDT).

Findings

The research utilises a novel digital research approach for accurately detecting and recording the localisation of structural cracks in concrete beams. This non-destructive low-cost approach was shown to perform with a high degree of accuracy and precision, as verified by the LVDT measurements. This research is testament to the fact that as technological advancements progress at an exponential rate, the cost of implementation continues to reduce to produce higher-accuracy “mass-market” solutions for industry practitioners.

Originality/value

Accurate structural health monitoring of concrete structures necessitates expensive equipment, complex signal processing and skilled operator. The concrete industry is in dire need of a simple but reliable technique that can reduce the testing time, cost and complexity of maintenance of structures. This was the first experiment of its kind that seeks to develop an unconventional approach to solve the maintenance problem associated with concrete structures. This study merges industry 4.0 digital technologies with a novel low-cost and automated hybrid analysis for real-time structural health monitoring of concrete beams by fusing several multidisciplinary approaches into one integral technological configuration.

Details

International Journal of Building Pathology and Adaptation, vol. 39 no. 2
Type: Research Article
ISSN: 2398-4708

Keywords

1 – 10 of 10