Search results
1 – 10 of 45Katarina Cvejin, Libu Manjakkal, Jan Kulawik, Krzysztof Zaraska and Dorota Szwagierczak
– This paper aims to investigate different properties of synthesized perovskite Sm0.9Sr0.1CoO3-δ and its potential for application in potentiometric oxygen sensors.
Abstract
Purpose
This paper aims to investigate different properties of synthesized perovskite Sm0.9Sr0.1CoO3-δ and its potential for application in potentiometric oxygen sensors.
Design/methodology/approach
The powder was obtained through solid-state reaction method and characterized by thermogravimetric/differential thermal analyzer and X-ray diffraction. It was used for both making a paste and pressing into rods for sintering. The prepared paste was deposited on alumina and yttria-stabilized zirconia substrates, by screen printing. Thick film conductivity, bulk conductivity and Seebeck coefficient of sintered rods were measured as a function of temperature. An oxygen concentration cell was fabricated with the screen-printed perovskite material as electrodes.
Findings
Electrical conductivity of the bulk sample and thick film increases with the increase in temperature, showing semiconductor-like behavior, which is also indicated by relatively high values of the measured Seebeck coefficient. Estimated values of the activation energy for conduction are found to be of the same magnitude as those reported in the literature for similar composition. An investigation of Nernstian behavior of the fabricated cell confirmed that Sm0.9Sr0.1CoO3-δ is a promising material for application in oxygen potentiometric sensors.
Originality/value
Gas sensor research is focused on the development of new sensitive materials. Although there is scarce information on SmCoO3-δ in the literature, it is mostly investigated for fuel cell applications. Results of this study imply that Sr-doped SmCoO3-δ is a good candidate material for oxygen potentiometric sensor.
Details
Keywords
Chinmay Roy, Aparna Ghosh and Suman Chatterjee
This paper aims to estimate the relationship between defect structure with gas concentration for use as a gas sensor. The change in defect concentration caused a shift in the…
Abstract
Purpose
This paper aims to estimate the relationship between defect structure with gas concentration for use as a gas sensor. The change in defect concentration caused a shift in the Fermi level, which in turn changed the surface potential, which is manifested as the potentiometric response of the sensing element.
Design/methodology/approach
A new theoretical concept based on defect chemistry and band structure was used to explain the experimental gas response of a sensor. The theoretically simulated response was compared with experimental results.
Findings
Understanding the origin of potentiometric response, through the generation of defects and a corresponding shift in Fermi level of sensing surface, by the adsorption of gas. Through this understanding, the design of a sensor with improved selectivity and stability to a gas can be achieved by the study of defect structure and subsequent band analysis.
Research limitations/implications
This paper provides information about various types of surface defects and numerical simulation of material with defect structure. The Fermi energy of the simulated value is correlated with the potentiometric sensor response.
Practical implications
Gas sensors are an integral part of vehicular and industrial pollution control. The theory developed shows the origin of response which can help in identifying the best sensing material and its optimum temperature of operation.
Social implications
Low-cost, reliable and highly sensitive gas sensors are highly demanded which is fulfilled by potentiometric sensors.
Originality/value
The operating principle of potentiometric sensors is analyzed through electron band structure analysis. With the change in measured gas concentration, the oxygen partial pressure changes. This results in a change in defect concentration in the sensing surface. Band structure analysis shows that change in defect concentration is associated with a shift in Fermi level. This is the origin of the potentiometric response.
Details
Keywords
Discusses intelligent materials, intelligent material‐based sensors, their transducing methods, and different kinds of transducers used with smart material‐based sensors. Assumes…
Abstract
Discusses intelligent materials, intelligent material‐based sensors, their transducing methods, and different kinds of transducers used with smart material‐based sensors. Assumes that the future of intelligent sensors will almost totally depend on intelligent chemistry and intelligent instrumentation. Molecular recognition will widen the horizons of smart systems with the help of VLSI‐based design and fabrication. Discusses different sensor mechanisms, such as ENFETs, immunoFETs, ISFETs and chemFETs and takes a detailed look at potentiometric, amperometric and optical biosensors.
Details
Keywords
Sari Lakkis, Rafic Younes, Yasser Alayli and Mohamad Sawan
This paper aims to give an overview about the state of the art and novel technologies used in gas sensing. It also discusses the miniaturization potential of some of these…
Abstract
Purpose
This paper aims to give an overview about the state of the art and novel technologies used in gas sensing. It also discusses the miniaturization potential of some of these technologies in a comparative way.
Design/methodology/approach
In this article, the authors state the most of the methods used in gas sensing discuss their advantages and disadvantages and at last the authors discuss the ability of their miniaturization comparing between them in terms of their sensing parameters like sensitivity, selectivity and cost.
Findings
In this article, the authors will try to cover most of the important methods used in gas sensing and their recent developments. The authors will also discuss their miniaturization potential trying to find the best candidate among the different types for the aim of miniaturization.
Originality/value
In this article, the authors will review most of the methods used in gas sensing and discuss their miniaturization potential delimiting the research to a certain type of technology or application.
Xingxing Li, Shixi You, Zengchang Fan, Guangjun Li and Li Fu
This review provides an overview of recent advances in electrochemical sensors for analyte detection in saliva, highlighting their potential applications in diagnostics and health…
Abstract
Purpose
This review provides an overview of recent advances in electrochemical sensors for analyte detection in saliva, highlighting their potential applications in diagnostics and health care. The purpose of this paper is to summarize the current state of the field, identify challenges and limitations and discuss future prospects for the development of saliva-based electrochemical sensors.
Design/methodology/approach
The paper reviews relevant literature and research articles to examine the latest developments in electrochemical sensing technologies for saliva analysis. It explores the use of various electrode materials, including carbon nanomaterial, metal nanoparticles and conducting polymers, as well as the integration of microfluidics, lab-on-a-chip (LOC) devices and wearable/implantable technologies. The design and fabrication methodologies used in these sensors are discussed, along with sample preparation techniques and biorecognition elements for enhancing sensor performance.
Findings
Electrochemical sensors for salivary analyte detection have demonstrated excellent potential for noninvasive, rapid and cost-effective diagnostics. Recent advancements have resulted in improved sensor selectivity, stability, sensitivity and compatibility with complex saliva samples. Integration with microfluidics and LOC technologies has shown promise in enhancing sensor efficiency and accuracy. In addition, wearable and implantable sensors enable continuous, real-time monitoring of salivary analytes, opening new avenues for personalized health care and disease management.
Originality/value
This review presents an up-to-date overview of electrochemical sensors for analyte detection in saliva, offering insights into their design, fabrication and performance. It highlights the originality and value of integrating electrochemical sensing with microfluidics, wearable/implantable technologies and point-of-care testing platforms. The review also identifies challenges and limitations, such as interference from other saliva components and the need for improved stability and reproducibility. Future prospects include the development of novel microfluidic devices, advanced materials and user-friendly diagnostic devices to unlock the full potential of saliva-based electrochemical sensing in clinical practice.
Details
Keywords
Thick‐film technology to implement passive elements, network and hybrid circuits has been widely used for four decades and its importance is still growing. While on one hand the…
Abstract
Thick‐film technology to implement passive elements, network and hybrid circuits has been widely used for four decades and its importance is still growing. While on one hand the technology has been improved to meet the requirements for more sophisticated circuits, on the other hand a better knowledge of its outstanding properties has promoted its application to a certain number of sometimes exotic devices, many of which are in the sensor and actuator area. This paper presents examples of a variety of applications to illustrate what thick film technology can offer outside the familiar area, and to stimulate the imagination of scientists towards possible new applications.
Pankaj Mandpe, Bala Prabhakar, Hunny Gupta and Pravin Shende
The present study aims to summarize different non-invasive techniques for continuous glucose monitoring (CGM) in diabetic patients using glucose-oxidase biosensors. In diabetic…
Abstract
Purpose
The present study aims to summarize different non-invasive techniques for continuous glucose monitoring (CGM) in diabetic patients using glucose-oxidase biosensors. In diabetic patients, the self-monitoring of blood glucose (BG) levels through minimally invasive techniques provides a quick method of measuring their BG concentration, unlike conventional laboratory measurements. The drawbacks of minimally invasive techniques include physical pain, anxiety and reduced patient compliance. To overcome these limitations, researchers shifted their attention towards the development of a pain-free and non-invasive glucose monitoring system, which showed encouraging results.
Design/methodology/approach
This study reviews the development of minimally and non-invasive method for continuous glucose level monitoring in diabetic or hyperglycemic patients. Specifically, glucose monitoring using non-invasive techniques, such as spectroscopy-based methods, polarimetry, fluorescence, electromagnetic variations, transdermal extraction-based methods and using body fluids, has been discussed. The various strategies adopted for improving the overall specificity and performance of biosensors are discussed.
Findings
In conclusion, the technology of glucose oxidase-based biosensors for glucose level monitoring is becoming a strong competitor, probably because of high specificity and selectivity, low cost and increased patient compliance. Many industries currently working in this field include Google, Novartis and Microsoft, which demonstrates the significance and strong market potential of self-monitored glucose-oxidase-based biosensors in the near future.
Originality/value
This review paper summarizes comprehensive strategies for continuous glucose monitoring (CGM) in diabetic patients using non-invasive glucose-oxidase biosensors. Non-invasive techniques received significant research interest because of high sensitivity and better patient compliance, unlike invasive ones. Although the results from these innovative devices require frequent calibration against direct BG data, they might be a preferable candidate for future CGM. However, the challenges associated with designing accurate level sensors to biomonitor BG data easily and painlessly needs to be addressed.
This article aims to review the different devices that are available for the in situ monitoring of analytes found in the marine environment.
Abstract
Purpose
This article aims to review the different devices that are available for the in situ monitoring of analytes found in the marine environment.
Design/methodology/approach
Following a short introduction to the topic, this paper discusses physical‐ and chemical‐based sensors, automatic analysers (flow injection, spectroscopic and spectrometric), electrochemical devices and biosensors.
Findings
A wide range of in situ monitoring systems (and associated deployment apparatus) for measuring concentrations of various analytes (e.g. nutrients, organic chemicals and metallic elements) have been developed in recent decades. Many of these systems are still at the laboratory or prototype stage and are yet to be fully developed into commercially available products. The harsh conditions often found in the marine environment can further limit the utility and application of these sensors. Further development work is needed; however, the need now is for field deployments, validation and inter‐calibration between sensors and other analytical measurement techniques.
Originality/value
This paper provides up‐to‐date information on in situ technologies that are available, either at the laboratory and prototype stages or commercially, and are suitable for deployment in the marine environment. Applications of these sensing systems are discussed together with their associated advantages and disadvantages over other existing water monitoring methods.
Details
Keywords
Sajad Pirsa and Fahime Purghorbani
In this study, an attempt has been made to collect the research that has been done on the construction and design of the H2O2 sensor. So far, many efforts have been made to…
Abstract
Purpose
In this study, an attempt has been made to collect the research that has been done on the construction and design of the H2O2 sensor. So far, many efforts have been made to quickly and sensitively determine H2O2 concentration based on different analytical principles. In this study, the importance of H2O2, its applications in various industries, especially the food industry, and the importance of measuring it with different techniques, especially portable sensors and on-site analysis, have been investigated and studied.
Design/methodology/approach
Hydrogen peroxide (H2O2) is a very simple molecule in nature, but due to its strong oxidizing and reducing properties, it has been widely used in the pharmaceutical, medical, environmental, mining, textile, paper, food production and chemical industries. Sensitive, rapid and continuous detection of H2O2 is of great importance in many systems for product quality control, health care, medical diagnostics, food safety and environmental protection.
Findings
Various methods have been developed and applied for the analysis of H2O2, such as fluorescence, colorimetry and electrochemistry, among them, the electrochemical technique due to its advantages in simple instrumentation, easy miniaturization, sensitivity and selectivity.
Originality/value
Monitoring the H2O2 concentration level is of practical importance for academic and industrial purposes. Edible oils are prone to oxidation during processing and storage, which may adversely affect oil quality and human health. Determination of peroxide value (PV) of edible oils is essential because PV is one of the most common quality parameters for monitoring lipid oxidation and oil quality control. The development of cheap, simple, fast, sensitive and selective H2O2 sensors is essential.
Details
Keywords
J.K. Atkinson, M. Glanc, M. Prakorbjanya, M. Sophocleous, R.P. Sion and E. Garcia‐Breijo
The purpose of this paper is to report thick film environmental and chemical sensor arrays designed for deployment in both subterranean and submerged aqueous applications.
Abstract
Purpose
The purpose of this paper is to report thick film environmental and chemical sensor arrays designed for deployment in both subterranean and submerged aqueous applications.
Design/methodology/approach
Various choices of materials for reference electrodes employed in these different applications have been evaluated and the responses of the different sensor types are compared and discussed.
Findings
Results indicate that the choice of binder materials is critical to the production of sensors capable of medium term deployment (e.g. several days) as the binders not only affect the tradeoff between hydration time and drift but also have a significant bearing on device sensitivity and stability. Sensor calibration is shown to remain an issue with long‐term deployments (e.g. several weeks) but this can be ameliorated in the medium term with the use of novel device fabrication and packaging techniques.
Originality/value
The reported results indicate that is possible through careful choice of materials and fabrication methods to achieve near stable thick film reference electrodes that are suitable for use in solid state chemical sensors in a variety of different application areas.
Details