Search results

1 – 10 of 14
Article
Publication date: 4 August 2021

Nehad Magdy and Sameh Gafar

The purpose of this research paper is to study a comparison between two dosimetry systems, both of them based on basic violet dye (BV).

Abstract

Purpose

The purpose of this research paper is to study a comparison between two dosimetry systems, both of them based on basic violet dye (BV).

Design/methodology/approach

The first system depends on (BV) (incorporating polyvinyl alcohol) as a thin-film dosimeter. The second system also relies on (BV) as a solution dosimeter, which is more sensitive to gamma rays. The two prepared film/solutions have a considerable signal that decreases upon irradiation and the strength of the signal decreases with increasing radiation dose.

Findings

The gamma ray absorbed dose for these dosimeters was found to be up to 35 kGy for films and 1 kGy for the liquid phase. All dosimetric characteristics as radiation chemical yield, additive substance, dose-response function, radiation sensitivity, also before and after-irradiation stability under various conditions were considered.

Practical implications

It is expected the vital role of gamma radiation on this dye in its two forms or two media. This reveals their wide applications in the field of gamma irradiation processing.

Originality/value

These two dosimetry systems which depend upon the same dye are safe to handle, inexpensive, available raw materials and can be applied in various dosimetry applications as mentioned above.

Details

Pigment & Resin Technology, vol. 51 no. 2
Type: Research Article
ISSN: 0369-9420

Keywords

Article
Publication date: 29 September 2020

Awad AL Zahrany, Khalid Rabaeh, Molham Eyadeh and Ahmed Basfar

The purpose of this paper is to present a radiochromic film dosimeter containing polyvinyl alcohol (PVA) matrix and various concentrations of methyl red (MR) dye for high dose…

Abstract

Purpose

The purpose of this paper is to present a radiochromic film dosimeter containing polyvinyl alcohol (PVA) matrix and various concentrations of methyl red (MR) dye for high dose measurements.

Design/methodology/approach

The MR-PVA films were exposed to irradiation up to 60 kGy using 60Co source of gamma ray. The ultraviolet and visible regions (UV/VIS) spectrophotometry were used to examine the optical density of pre-and post-irradiated dosimeters at 424 nm.

Findings

The dose sensitivity of MR-PVA films increases significantly with increasing MR dye concentrations in the dose range of 5 to 60 kGy. The impact of relative humidity, irradiation temperature, dose rate and the stability of the films has been analyzed. The overall uncertainty of the MR-PVA film dosimeter is 6.12% (Double Standard-deviation, 95% confidence level).

Practical implications

It was found that the MR-PVA films may be used as high dose dosimeter with an acceptable overall uncertainty in routine industrial radiation processing.

Originality/value

The color bleaching of irradiated MR-PVA films in terms of specific absorbance curves increases significantly with increasing absorbed dose up to 60 kGy.

Details

Pigment & Resin Technology, vol. 50 no. 2
Type: Research Article
ISSN: 0369-9420

Keywords

Article
Publication date: 27 February 2020

Khalid Rabaeh and Ahmed Basfar

The purpose of this paper is to propose a new dithizone solution dosimeter for high radiation applications such as polymers applications and food irradiation.

Abstract

Purpose

The purpose of this paper is to propose a new dithizone solution dosimeter for high radiation applications such as polymers applications and food irradiation.

Design/methodology/approach

Gamma-rays cell of Co-60 source with 8.4 kGy/h dose rate was used to irradiate the dithizone solutions at different irradiation temperatures. The optical measurements of unirradiated and irradiated dithizone dye solution dosimeters were performed using a UV/VIS spectrophotometer at absorption peaks of 421 and 515 nm.

Findings

The new dosimeter improved significantly with the increase of dithizone dye concentrations from 0.025 to 0.1 mM. The dosimeter shows a perfect pre- and post-irradiation stability after irradiation for five days. Because of irradiation temperature dependence, the dithizone solution dosimeter should be corrected under actual processing conditions.

Practical implications

Dosimetry is a key point in quality control of radiation processing to assure that uniform and correct radiation doses are delivered to a region of interest. Therefore, this study introduces a dithizone solution dosimeter for high-dose radiation applications such as food irradiation, polymers applications and agriculture.

Originality/value

Ionizing radiation interacted with the ethanol solvent, resulting in the formation of free radicals, then these free radicals interacted with the dithizone molecule and changed the dye color from yellow to orange.

Details

Pigment & Resin Technology, vol. 49 no. 4
Type: Research Article
ISSN: 0369-9420

Keywords

Article
Publication date: 28 March 2008

S. O'Keeffe, C. Fitzpatrick, E. Lewis and A.I. Al‐Shamma'a

The purpose of this paper is to provide a detailed review of radiation dosimetry techniques based on optical fibre dosimeters. It presents a comprehensive bibliography of the…

2879

Abstract

Purpose

The purpose of this paper is to provide a detailed review of radiation dosimetry techniques based on optical fibre dosimeters. It presents a comprehensive bibliography of the current research activities in the area.

Design/methodology/approach

A range of published work on optical fibre radiation dosimeters are presented, with the merits and limitations discussed. Each radiation dosimetry technique is discussed in turn, providing examples of dosimeters using such techniques reviewed. The main focus is on gamma radiation although other radiation dosimeters are considered.

Findings

This paper provides information on the wide range of research activity into radiation dosimeters. The dose ranges of these dosimeters are presented, along with the advantages and disadvantages of different dosimetry techniques.

Originality/value

A comprehensive review of published research in the area of solid radiation dosimetry is presented in this paper. It provides an individual with a review of the various techniques used and most recent research in that field.

Details

Sensor Review, vol. 28 no. 2
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 3 October 2019

Sameh Mohamed Gafar and Nehad Magdy Abdel-Kader

The purpose of this paper is to study the effect of gamma-rays on murexide (Mx) dye and its possible use as radiation dosimeters in two different dosimetry systems. The first…

Abstract

Purpose

The purpose of this paper is to study the effect of gamma-rays on murexide (Mx) dye and its possible use as radiation dosimeters in two different dosimetry systems. The first system depends on the Mx dye as a liquid dosimeter. The second dosimetry system depends also on the same dye but as in a gel form, which is more sensitive to gamma-rays.

Design/methodology/approach

The prepared Mx (solutions/gels) have a considerable two peaks at 324 and 521 nm that upon irradiation, the intensity of these peaks decreases with the increasing radiation dose.

Findings

The gamma-ray absorbed dose for these dosimeters was found to be up to 2 kGy for the solution samples and 40 Gy for the gels. Radiation chemical yield, dose response function, radiation sensitivity and before and after-irradiation stability under various conditions were discussed and studied.

Practical implications

It is expected that the radiolysis of the Mx dye can be used as radiation dosimeters in two different dosimetry systems; liquid and gel dosimeters. This can be applied in a wide range of gamma radiation practical industrial applications in water treatment, food irradiation dosimeters, radiotherapy and fresh food irradiation and seed production.

Originality/value

Both of the prepared Mx dyes, either as solutions or gel samples, can be facilely prepared from commercially, cheap, safe, available chemicals and suitable for useful applied Mx solutions and gels radiation dosimeters.

Details

Pigment & Resin Technology, vol. 48 no. 6
Type: Research Article
ISSN: 0369-9420

Keywords

Article
Publication date: 23 August 2021

Mohamad Bekhit, Essam Fahim and Asmaa Sobhy

The purpose of this paper is to fall light on the possibility of using the biopolymer chitosan in gamma dose monitoring.

140

Abstract

Purpose

The purpose of this paper is to fall light on the possibility of using the biopolymer chitosan in gamma dose monitoring.

Design/methodology/approach

The chitosan films were irradiated to gamma rays in the range starting from 10 to 120 kGy at a dose rate of 1.4 kGy/h using 60Co gamma source. The ultra violet and visible (UV/Vis) spectrophotometry were used to examine the optical properties of chitosan film. Also, Fourier transform infrared (FTIR) analysis was used to detect and trace any change in structural bands that may take place upon irradiation.

Findings

Increase in optical density of the chitosan film was recorded at 298 nm that correlated with increasing in the absorbed doses. Change in color of the film from pale yellow to denser yellow was detected upon increasing the absorbed doses. The close investigation for UV/Vis and FTIR analysis nominates the chitosan film to be used as a label-dosimeter in the range of 10–120 kGy depending on chitosan concentrations. The chitosan film has an excellent stability in different environmental conditions with ±3.7% uncertainty in measurements (2σ, approximately equal to a 95% confidence level).

Research limitations/implications

Chitosan film may be used as a medium and high-dose monitor with an acceptable overall uncertainty in routine radiation processing

Originality/value

The useful dose range from 10 to 80 kGy was detected for different concentrations of chitosan (0.5, 1, 1.5 Wt%) that correlated with increasing the absorbed dose, which is assigned to the linear parts in the target response curves. For the dose range 10–120 kGy, the film may be used as label dosimeter with detected color change from pale yellow to dense yellow.

Details

Pigment & Resin Technology, vol. 51 no. 5
Type: Research Article
ISSN: 0369-9420

Keywords

Article
Publication date: 1 April 1995

R. Rahman, A.K.M.M. Haque and S. Sumar

Reviews the various physical methods available for the detection ofirradiated foods in the areas of: measuring changes in physicalproperties; luminescent detection; and electron…

337

Abstract

Reviews the various physical methods available for the detection of irradiated foods in the areas of: measuring changes in physical properties; luminescent detection; and electron spin resonance. Concludes that many of the techniques hold great potential as simple screening methods.

Details

Nutrition & Food Science, vol. 95 no. 2
Type: Research Article
ISSN: 0034-6659

Keywords

Article
Publication date: 1 January 1972

P.G. Garrett

Although the technique of electron curing has been well developed, there are very few suitable coatings available.

Abstract

Although the technique of electron curing has been well developed, there are very few suitable coatings available.

Details

Pigment & Resin Technology, vol. 1 no. 1
Type: Research Article
ISSN: 0369-9420

Article
Publication date: 29 March 2019

Xueqin Kang, Chi Yao and Shirong Ge

This paper aims to investigate the effect of simulated body fluid (SBF) on biodegradation and tribological properties of ultrahigh molecular weight polyethylene (UHMWPE) and…

Abstract

Purpose

This paper aims to investigate the effect of simulated body fluid (SBF) on biodegradation and tribological properties of ultrahigh molecular weight polyethylene (UHMWPE) and UHMWPE stabilized with α-tocopherol.

Design/methodology/approach

The samples of UHMWPE and UHMWPE stabilized with α-tocopherol were prepared by a hot-pressing method, and then immersed in SBF for one year. Tribological test was performed on a UMT-2 tribometer.

Findings

The crystallinity and tribological properties increased slightly after UHMWPE stabilized with α-tocopherol, whereas the O/C ration decreased slightly. The crystallinity and O/C ratio increased after all samples immersed in SBF for one year. This resulted in the deterioration of tribological properties and the wear mechanism change. The tribological properties change was smaller in UHMWPE stabilized with α-tocopherol than that in UHMWPE, because the oxidation resistance of UHMWPE was increased by α-tocopherol.

Originality/value

The results of the experimental studies demonstrated and compared the biodegradation behavior and tribological properties of UHMWPE, UHMWPE stabilized with α-tocopherol, and after they immersed in SBF for one year.

Details

Industrial Lubrication and Tribology, vol. 71 no. 3
Type: Research Article
ISSN: 0036-8792

Keywords

Article
Publication date: 1 April 1991

Cheryl Pellerin

More than 100 engineers and researchers from industry and from government and academic laboratories met in Pittsburgh, Pennsylvania, in September at the Fourth World Conference on…

Abstract

More than 100 engineers and researchers from industry and from government and academic laboratories met in Pittsburgh, Pennsylvania, in September at the Fourth World Conference on Robotics Research, sponsored by Robotics International of the Society of Manufacturing Engineers.

Details

Industrial Robot: An International Journal, vol. 18 no. 4
Type: Research Article
ISSN: 0143-991X

1 – 10 of 14