Search results

1 – 4 of 4
Article
Publication date: 19 March 2019

Muhammad Izzuddin Abd Samad, Muhamad Ramdzan Buyong, Shyong Siow Kim and Burhanuddin Yeop Majlis

The purpose of this paper is to use a particle velocity measurement technique on a tapered microelectrode device via changes of an applied voltage, which is an enhancement of the…

Abstract

Purpose

The purpose of this paper is to use a particle velocity measurement technique on a tapered microelectrode device via changes of an applied voltage, which is an enhancement of the electric field density in influencing the dipole moment particles. Polystyrene microbeads (PM) have used to determine the responses of the dielectrophoresis (DEP) voltage based on the particle velocity technique.

Design/methodology/approach

Analytical modelling was used to simulate the particles’ polarization and their velocity based on the Clausius–Mossotti Factor (CMF) equation. The electric field intensity and DEP forces were simulated through the COMSOL numerical study of the variation of applied voltages such as 5 V p-p, 7 V p-p and 10 V p-p. Experimentally, the particle velocity on a tapered DEP response was quantified via the particle travelling distance over a time interval through a high-speed camera adapted to a high-precision non-contact depth measuring microscope.

Findings

The result of the particle velocity was found to increase, and the applied voltage has enhanced the particle trajectory on the tapered microelectrode, which confirmed its dependency on the electric field intensity at the top and bottom edges of the electrode. A higher magnitude of particle levitation was recorded with the highest particle velocity of 11.19 ± 4.43 µm/s at 1 MHz on 10 V p-p, compared to the lowest particle velocity with 0.62 ± 0.11 µm/s at 10 kHz on 7 V p-p.

Practical implications

This research can be applied for high throughout sensitivity and selectivity of particle manipulation in isolating and concentrating biological fluid for biomedical implications.

Originality/value

The comprehensive manipulation method based on the changes of the electrical potential of the tapered electrode was able to quantify the magnitude of the particle trajectory in accordance with the strong electric field density.

Details

Microelectronics International, vol. 36 no. 2
Type: Research Article
ISSN: 1356-5362

Keywords

Article
Publication date: 21 May 2019

Nurul Aida Farhana Othman, Sharidya Rahman, Sharifah Fatmadiana Wan Muhamad Hatta, Norhayati Soin, Brahim Benbakhti and Steven Duffy

To design and optimize the traditional aluminum gallium nitride/gallium nitride high electron mobility transistor (HEMT) device in achieving improved performance and current…

Abstract

Purpose

To design and optimize the traditional aluminum gallium nitride/gallium nitride high electron mobility transistor (HEMT) device in achieving improved performance and current handling capability using the Synopsys’ Sentaurus TCAD tool.

Design/methodology/approach

Varying material and physical considerations, specifically investigating the effects of graded barriers, spacer interlayer, material selection for the channel, as well as study of the effects in the physical dimensions of the HEMT, have been extensively carried out.

Findings

Critical figure-of-merits, specifically the DC characteristics, 2DEG concentrations and mobility of the heterostructure device, have been evaluated. Significant observations include enhancement of maximum current density by 63 per cent, whereas the electron concentration was found to propagate by 1,020 cm−3 in the channel.

Practical implications

This work aims to provide tactical optimization to traditional heterostructure field effect transistors, rendering its application as power amplifiers, Monolithic Microwave Integrated Circuit (MMICs) and Radar, which requires low noise performance and very high radio frequency design operations.

Originality/value

Analysis in covering the breadth and complexity of heterostructure devices has been carefully executed through extensive TCAD modeling, and the end structure obtained has been optimized to provide best performance.

Details

Microelectronics International, vol. 36 no. 2
Type: Research Article
ISSN: 1356-5362

Keywords

Article
Publication date: 21 November 2023

Lochan Singh and Vijay Singh Sharanagat

Nature and occurrence of food-borne pathogens in raw and processed food products evolved greatly in the past few years due to new modes of transmission and resistance build-up…

148

Abstract

Purpose

Nature and occurrence of food-borne pathogens in raw and processed food products evolved greatly in the past few years due to new modes of transmission and resistance build-up against sundry micro-/macro-environmental conditions. Assurance of food health and safety thus gained immense importance, for which bio-sensing technology proved very promising in the detection and quantification of food-borne pathogens. Considering the importance, different studies have been performed, and different biosensors have been developed. This study aims to summarize the different biosensors used for the deduction of food-borne pathogens.

Design/methodology/approach

The present review highlights different biosensors developed apropos to food matrices, factors governing their selection, their potential and applicability. The paper discusses some related key challenges and constraints and also focuses on the needs and future research prospects in this field.

Findings

The shift in consumers’ and industries’ perceptions directed the further approach to achieve portable, user and environmental friendly biosensing techniques. Despite of these developments, it was still observed that the comparison among the different biosensors and their categories proved tedious on a single platform; since the food matrices tested, pathogen detected or diagnosed, time of detection, etc., varied greatly and very few products have been commercially launched. Conclusively, a challenge lies in front of food scientists and researchers to maintain pace and develop techniques for efficiently catering to the needs of the food industry.

Research limitations/implications

Biosensors deduction limit varied with the food matrix, type of organism, material of biosensors’ surface, etc. The food matrix itself consists of complex substances, and various types of food are available in nature. Considering the diversity of food there is a need to develop a universal biosensor that can be used for all the food matrices for a pathogen. Further research is needed to develop a pathogen-specific biosensor that can be used for all the food products that may have accuracy to eliminate the traditional method of deduction.

Originality/value

The present paper summarized and categorized the different types of biosensors developed for food-borne pathogens.

Graphical abstract

Details

Nutrition & Food Science , vol. 54 no. 1
Type: Research Article
ISSN: 0034-6659

Keywords

Article
Publication date: 23 September 2020

Muhamad Ramdzan Buyong, Farhad Larki, Muhamad Ikhmal Hakimi Zainal, Abdelaziz Yousif Ahmed Almahi, Ahmad Ghadafi Ismail, Azrul Azlan Hamzah, Aminuddin Ahmad Kayani Kayani, Céline Elie Caille and Burhanuddin Yeop Majlis

This paper aims to present the capacitance characterization of tapered dielectrophoresis (DEP) microelectrodes as micro-electro-mechanical system sensor and actuator device. The…

Abstract

Purpose

This paper aims to present the capacitance characterization of tapered dielectrophoresis (DEP) microelectrodes as micro-electro-mechanical system sensor and actuator device. The application of DEP-on-a-chip (DOC) can be used to evaluate and correlate the capacitive sensing measurement at an actual position and end station of liquid suspended targeted particles by DEP force actuator manipulation.

Design/methodology/approach

The capability of both, sensing and manipulation was analysed based on capacitance changes corresponding to the particle positioning and stationing of the targeted particles at regions of interest. The mechanisms of DEP sensor and actuator, designed in DOC applications were energized by electric field of tapered DEP microelectrodes. The actual DEP forces behaviour has been also studied via quantitative analysis of capacitance measurement value and its correlation with qualitative analysis of positioning and stationing of targeted particles.

Findings

The significance of the present work is the ability of using tapered DEP microelectrodes in a closed mode system to simultaneously sense and vary the magnitude of manipulation.

Originality/value

The integration of DOC platform for contactless electrical-driven with selective detection and rapid manipulation can provide better efficiency in in situ selective biosensors or bio-detection and rapid bio-manipulation for DOC diagnostic and prognostic devices.

Details

Microelectronics International, vol. 37 no. 4
Type: Research Article
ISSN: 1356-5362

Keywords

1 – 4 of 4