Search results

1 – 10 of 821
Article
Publication date: 25 July 2023

Rasha Adel, Naglaa Megahed, Asmaa M. Hassan and Merhan Shahda

Passive design strategies contribute to improving indoor comfort conditions and reducing buildings' energy consumption. For several years, courtyards have received wide attention…

Abstract

Purpose

Passive design strategies contribute to improving indoor comfort conditions and reducing buildings' energy consumption. For several years, courtyards have received wide attention from researchers because of their significant role in reducing energy demand. However, the abundance of multi-story buildings and the courtyards' incompatibility with them, the courtyard is currently limited. Therefore, it is necessary to search for alternatives. This paper aims to bridge the gaps in previous limited studies considering skycourt as a passive alternative on the vertical plane of the facades in contrast to the courtyard.

Design/methodology/approach

This research presents an overview and a bibliometric analysis of the evolution of the courtyard to the skycourt via VOSviewer software and the bibliometrix R package.

Findings

The research provided various concepts related to skycourt as a promising passive design strategy, which can be suitable for multi-story buildings, starting with its evolution, characteristics, configurations, benefits, and challenges.

Practical implications

The findings can urge designers, researchers and policymakers to incorporate such an important passive alternative.

Social implications

Researchers, instructors, educational specialists, faculty members, and decision-makers can provide design motivation for skycourt in buildings, in addition to achieving awareness about skycourt and its significant benefits and its role as an important passive design strategy.

Originality/value

The research highlights the possibilities of the skycourt and its role as a passive design element as an extension of the courtyard in addition to identifying design indicators that help designers determine the appropriate designs.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 22 August 2023

Xian Yun Tan, Norhayati Mahyuddin, Syahrul Nizam Kamaruzzaman, Norhayati Mat Wajid and Abdul Murad Zainal Abidin

Commercial buildings, which include office buildings, are one of the three major energy-consuming sectors, alongside industrial and transportation sectors. The vast increase in…

Abstract

Purpose

Commercial buildings, which include office buildings, are one of the three major energy-consuming sectors, alongside industrial and transportation sectors. The vast increase in the number of buildings is a positive sign of the rapid development of Malaysia. However, most Malaysian government office buildings tend to consume energy inefficiently due to lack of energy optimization. Most of the previous studies focused on the performance of green buildings in fulfilling the green development guidelines. As such, it is essential to study the energy performance of existing government office buildings that were constructed before most energy-efficient standards were implemented to mitigate energy wastage due to the lack of energy optimization. This study aims to analyse the energy performance of existing non-green Malaysian government office buildings and the factors that influence building energy consumption, as well as to evaluate the efficacy of the existing energy conservation measures.

Design/methodology/approach

This study was conducted by a literature review and case study. The chosen buildings are six government office building blocks located in Kuala Lumpur, the capital city of Malaysia. In this study, a literature review has been conducted on the common factors affecting energy consumption in office buildings. The energy consumption data of the buildings were collected to calculate the building energy intensity (BEI). The BEI was compared to the MS1525:2019 and GBI benchmarks to evaluate energy performance. SketchUp software was utilized to illustrate the solar radiation and sun path diagram of the case study buildings. Finally, recommendations were derived for retrofit strategies based on non-design factors and passive design factors.

Findings

In typical government office buildings, the air-conditioning system consumed the most energy at 65.5%, followed by lighting system at 22.6%, and the remaining 11.9% was contributed by office appliances. The energy performance of the case study buildings is considered as satisfactory as the BEI did not exceed the MS1525:2019 benchmark of 200 kWh/m2/year. The E Block recorded the highest BEI of 183.12 kWh/m2/year in 2020 due to its north-east orientation which is exposed to the most solar radiation. Besides, E Block consists of rooms that can accommodate large number of occupants. As such, non-design factors which include higher occupancy rate and higher cooling demand due to high outdoor temperature leads to higher energy consumption. By considering passive design features such as building orientation and building envelope thermal properties, energy consumption can be reduced significantly.

Originality/value

This study provided a comprehensive insight into the energy performance of Malaysian government office buildings, which were constructed before the energy-efficient standards being introduced. By calculating the BEI of six government office buildings, it is found that the energy performance of the case study buildings fulfils the MS1525 benchmark, and that all their BEIs are below 200 kWh/m2/year. Malaysia's hot and humid climate significantly affects a building's cooling load, and it is found the air-conditioning system is the major energy consumer of Malaysian government office buildings. This study discusses the efficacy of the energy-saving measures implemented in the case study buildings to optimize energy consumption. Recommendations were derived based on the non-design factors and passive design factors that affected the energy consumption of the case study building. It is envisioned that this study can provide practical strategies for retrofit interventions to reduce energy consumption in Malaysian office buildings as well as for office buildings that are in a similar climate.

Details

Open House International, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0168-2601

Keywords

Article
Publication date: 3 March 2022

Mahdiyeh Zaferanchi and Hatice Sozer

The amount of energy consumption of buildings has obtained international concern so the concept of zero energy building becomes a target for building designers. There are various…

Abstract

Purpose

The amount of energy consumption of buildings has obtained international concern so the concept of zero energy building becomes a target for building designers. There are various definitions and evaluation methods for efficient buildings. However, detailed research about the critical parameters that have a major effect through the operational time to reduce the energy consumption is not emphasized as this paper represents. The main aim of this study is to identify the effect of applicable interventions on energy consumption parameters with their sensitivity to each other to reach zero energy building. Relatedly, the cost of energy reduction is also determined.

Design/methodology/approach

Energy consumption parameters were defined as area lightings, space heating, space cooling, ventilation fans, pumps, auxiliary equipment and related miscellaneous equipment. The effect of each applied intervention on energy consumption was classified as high, medium, low, very low, no effect and negative effect by utilizing a sensitivity analysis. The base case's energy model is created by utilizing energy performance software such as e-Quest. Accordingly, energy performance improvement scenarios are developed by applying interventions such as lamp replacements, sensors, heat pumps and photovoltaic panels’ integration. Furthermore, sensitivity analyses of each intervention were developed for consumed energy and its cost.

Findings

Results indicated the electric consumption is more effective than gas consumption on primary energy and energy cost. Solar systems decline primary energy by 78.53%, lighting systems by 13.47% and heat pump by 5.48% in this building; therefore, integrating mentioned strategies could rise the improvement rate to 100%, in other words, zero amount of energy is using from the grid that means saving $ 5,750.39 in one year.

Research limitations/implications

The study can be applied to similar buildings. It is worthwhile to investigate suggested methods in diverse buildings with different functions and climates in future works.

Practical implications

This study aims to investigate of energy consumption of an educational building in the Mediterranean climate to convert an existing building into a zero energy building by saving energy and renewable sources. Subsequent purposes are analyzing the effect of each strategy on energy consumption and cost.

Originality/value

The novelty of this study is filling gaps in sensitivity analysis of energy consumption parameters by not only identifying their effect on overall energy consumption but also identifying their effect on each other. Some interventions may have a positive effect on overall consumption while having a negative effect on each other. Identifying this critical effect in detail not only further improves the energy performance, but also may affect the decision-making of the interventions.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 5 April 2024

Fateme Akhlaghinezhad, Amir Tabadkani, Hadi Bagheri Sabzevar, Nastaran Seyed Shafavi and Arman Nikkhah Dehnavi

Occupant behavior can lead to considerable uncertainties in thermal comfort and air quality within buildings. To tackle this challenge, the use of probabilistic controls to…

Abstract

Purpose

Occupant behavior can lead to considerable uncertainties in thermal comfort and air quality within buildings. To tackle this challenge, the use of probabilistic controls to simulate occupant behavior has emerged as a potential solution. This study seeks to analyze the performance of free-running households by examining adaptive thermal comfort and CO2 concentration, both crucial variables in indoor air quality. The investigation of indoor environment dynamics caused by the occupants' behavior, especially after the COVID-19 pandemic, became increasingly important. Specifically, it investigates 13 distinct window and shading control strategies in courtyard houses to identify the factors that prompt occupants to interact with shading and windows and determine which control approach effectively minimizes the performance gap.

Design/methodology/approach

This paper compares commonly used deterministic and probabilistic control functions and their effects on occupant comfort and indoor air quality in four zones surrounding a courtyard. The zones are differentiated by windows facing the courtyard. The study utilizes the energy management system (EMS) functionality of EnergyPlus within an algorithmic interface called Ladybug Tools. By modifying geometrical dimensions, orientation, window-to-wall ratio (WWR) and window operable fraction, a total of 465 cases are analyzed to identify effective control scenarios. According to the literature, these factors were selected because of their potential significant impact on occupants’ thermal comfort and indoor air quality, in addition to the natural ventilation flow rate. Additionally, the Random Forest algorithm is employed to estimate the individual impact of each control scenario on indoor thermal comfort and air quality metrics, including operative temperature and CO2 concentration.

Findings

The findings of the study confirmed that both deterministic and probabilistic window control algorithms were effective in reducing thermal discomfort hours, with reductions of 56.7 and 41.1%, respectively. Deterministic shading controls resulted in a reduction of 18.5%. Implementing the window control strategies led to a significant decrease of 87.8% in indoor CO2 concentration. The sensitivity analysis revealed that outdoor temperature exhibited the strongest positive correlation with indoor operative temperature while showing a negative correlation with indoor CO2 concentration. Furthermore, zone orientation and length were identified as the most influential design variables in achieving the desired performance outcomes.

Research limitations/implications

It’s important to acknowledge the limitations of this study. Firstly, the potential impact of air circulation through the central zone was not considered. Secondly, the investigated control scenarios may have different impacts on air-conditioned buildings, especially when considering energy consumption. Thirdly, the study heavily relied on simulation tools and algorithms, which may limit its real-world applicability. The accuracy of the simulations depends on the quality of the input data and the assumptions made in the models. Fourthly, the case study is hypothetical in nature to be able to compare different control scenarios and their implications. Lastly, the comparative analysis was limited to a specific climate, which may restrict the generalizability of the findings in different climates.

Originality/value

Occupant behavior represents a significant source of uncertainty, particularly during the early stages of design. This study aims to offer a comparative analysis of various deterministic and probabilistic control scenarios that are based on occupant behavior. The study evaluates the effectiveness and validity of these proposed control scenarios, providing valuable insights for design decision-making.

Details

Smart and Sustainable Built Environment, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2046-6099

Keywords

Article
Publication date: 18 April 2023

Sundus Shareef, Emad S. Mushtaha, Saleh Abu Dabous and Imad Alsyouf

This paper investigates thermal mass performance (TMP) in hot climates. The impact of using precast concrete (PC) as a core envelope with different insulation materials has been…

Abstract

Purpose

This paper investigates thermal mass performance (TMP) in hot climates. The impact of using precast concrete (PC) as a core envelope with different insulation materials has been studied. The aim is to find the effect of building mass with different weights on indoor energy consumption, specifically cooling load in hot climates.

Design/methodology/approach

This research adopted a case study and simulation methods to find out the efficiency of different mass performances in hot and humid climate conditions. Different scenarios of light, moderate and heavyweight mass using PC have been developed and simulated. The impact of these scenarios on indoor cooling load has been investigated using the integrated environment solution-virtual environment (IES-VE) software.

Findings

The results showed that adopting a moderate weight mass of two PC sheets and a cavity layer in between can reduce indoor air temperature by 1.17 °C; however, this type of mass may increase the cooling demand. On the other hand, it has been proven that adopting a heavyweight mass for building envelopes and increasing the insulation material has a significant impact on reducing the cooling load. Using a PC Sandwich panel and increasing the insulation material layers for external walls and thickness by 50 mm will reduce the cooling load by 15.8%. Therefore, the heavyweight mass is more efficient compared to lightweight and moderate mass in hot, humid climate areas such as the UAE, in spite of the positive indoor TMP that can be provided by the lightweight mass in reducing the indoor air temperature in the summer season.

Originality/value

This research contributes to the thermal mass concept as one of these strategies that have recently been adopted to optimize the thermal performance of buildings and developments. Efficient TMP can have a massive impact on reducing energy consumption. However, less work has investigated TMP in hot and humid climate conditions. Furthermore, the impact of the PC on indoor thermal performance within hot climate areas has not been studied yet. The findings of this study on TMP in the summer season can be generated in all hot climate zones, and investigating the TMP in other seasons can be extended in future studies.

Details

Engineering, Construction and Architectural Management, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0969-9988

Keywords

Article
Publication date: 26 January 2024

Débora Domingo-Calabuig, Javier Rivera-Linares, Laura Lizondo-Sevilla and José Luis Alapont-Ramón

City planning and construction have embraced circular economy principles, converting them into various indicators. Particularly in the European context, the question “what…

Abstract

Purpose

City planning and construction have embraced circular economy principles, converting them into various indicators. Particularly in the European context, the question “what architecture for circularity?” is answered with policies focusing on techniques, materials and disassembling construction. This paper analyzes a new approach to sustainable design and explores the concept of Km0 architecture. The objective is to demonstrate the design strategies of a contemporary architecture based on local resources and knowledge, an architecture that works with the shortest possible loop in circularity, i.e. with the cycle that consumes the least amount of energy.

Design/methodology/approach

The paper presents two ways of understanding sustainability in architecture: the first as a result of policies and the second associated with the design and innovative-based New European Bauhaus initiative. Within the scope of this last understanding, the authors analyze three cases on the Spanish Mediterranean coast that have recently received media attention and prominence. The selection responds to a specific climate adaption through a certain typological and functional diversity of the works.

Findings

The studied cases exhibit a more equitable and cost-effective circularity based on the time factor, have long life-cycle designs and serve as repositories of cultural identity. Km0 architecture reduces emissions using local resources and mitigates environmental conditions by combining traditional and modern design strategies.

Originality/value

This paper fulfills an identified need to study the local understandings of the built environment that would ensure a more fair and inclusive European green transformation.

Details

Open House International, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0168-2601

Keywords

Article
Publication date: 1 September 2023

Dinçer Aydın and Şule Yılmaz Erten

The buildings should be designed by respecting the environmental and climatic conditions they are in and their orientation. Then, the characteristics of the building envelope (BE…

159

Abstract

Purpose

The buildings should be designed by respecting the environmental and climatic conditions they are in and their orientation. Then, the characteristics of the building envelope (BE) play an important role in building energy consumption and user comfort. In fact, the type and material of glazing is one of the crucial parameters for BE. The transparency ratio of BE also determines the façade performance. The aim of this study is to analyze the different renovation scenarios for BE with high transparency of an educational building (EB) in hot summer weather to obtain indoor thermal comfort (ITC) for users.

Design/methodology/approach

The methodology includes thorough measurement of existing ITC using TESTO-440 and simulation of each retrofit scenario using DesignBuilder building energy modeling (BEM) simulation software with Energyplus to determine optimal thermal comfort. Since the study focuses on the impact of the transparent BE on summer ITC, four main scenarios, naturally ventilated (NV) façade, film-coated glass façade, replacement of glazing with opaque units, sun-controlled façade with overhang and solar shading, were simulated. The results were analyzed comparatively on both performance and cost to find the best renovation solutions.

Findings

A total of 7 different renovation scenarios were tested. Simulation results show that passive systems such as NV have limited contribution to indoor air temperature (IAT) improvement, achieving only a 4 °C reduction while offering the lowest cost. A film coating resulted in a reduction of 3–6 °C, but these applications have the highest cost and least impact on ITC. It was found that exterior coating leads to better results in film coating. Preventing and limiting the increase in IAT was achieved by reducing the transparency ratio of BE. The best results were obtained in these scenarios, and it was possible to reduce IAT by more than 10 °C. The best performance/cost value were also obtained by decreasing transparency ratio of roof and sun control.

Research limitations/implications

Since the high transparency ratio has a negative impact on summer comfort, especially in hot climate zones, summer ITC was prioritized in the renovation solutions for the case building.

Originality/value

The study’s findings present a range of solutions for improving the ITC of highly transparent buildings. The solutions can help building managers see the differences in renovation costs and their impacts on ITC to decrease the cooling load of the existing buildings.

Details

Open House International, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0168-2601

Keywords

Article
Publication date: 18 January 2024

Nor Nazihah Chuweni, Nurul Sahida Fauzi, Asmma Che Kasim, Sekar Mayangsari and Nurhastuty Kesumo Wardhani

Sustainability represents innovative elements in determining the profitability of real estate investments, among other factors, including the green component in real estate…

Abstract

Purpose

Sustainability represents innovative elements in determining the profitability of real estate investments, among other factors, including the green component in real estate. Evidence from the literature has pointed out that incorporating green features into residential buildings can reduce operational costs and increase the building’s value. Although green real estate is considered the future trend of choice, it is still being determined whether prospective buyers are willing to accept the extra cost of green residential investment. Therefore, this study aims to investigate the effect of housing attributes and green certification on residential real estate prices.

Design/methodology/approach

The impact of the housing attribute and green certification in the residential sectors was assessed using a transaction data set comprising approximately 861 residential units sold in Selangor, Malaysia, between 2014 and 2022. Linear and quantile regression were used in this study by using SPSS software for a robust result.

Findings

The findings indicate that the market price of residential properties in Malaysia is influenced by housing attributes, transaction types and Green Building Index certification. The empirical evidence from this study suggests that green certification significantly affects the sales price of residential properties in Malaysia. The findings of this research will help investors identify measurable factors that affect the transaction prices of green-certified residential real estate. These identifications will facilitate the development of strategic plans aimed at achieving sustainable rates of return in the sustainable residential real estate market.

Practical implications

Specifically, this research will contribute to achieving area 4 of the 11th Malaysia Plan, which pertains to pursuing green growth for sustainability and resilience. This will be achieved by enhancing awareness among investors and homebuyers regarding the importance of green residential buildings in contributing to the environment, the economy and society.

Originality/value

The regression model for housing attributes and green certification on house price developed in this study could offer valuable benefits to support and advance Malaysia in realising its medium and long-term goals for green technology.

Details

International Journal of Housing Markets and Analysis, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1753-8270

Keywords

Article
Publication date: 23 October 2023

Francis O. Uzuegbunam, Fynecountry N. Aja and Eziyi O. Ibem

This research aims to investigate the influence of building design on the thermal comfort of occupants of naturally ventilated hospital (NVH) wards to identify the aspects with…

Abstract

Purpose

This research aims to investigate the influence of building design on the thermal comfort of occupants of naturally ventilated hospital (NVH) wards to identify the aspects with the most significant influence on the thermal comfort of hospital buildings during the hot-dry season in the hot-humid tropics of Southeast Nigeria.

Design/methodology/approach

Field measurements, physical observations and a questionnaire survey of 60 occupants of the wards of the Joint Presbyterian Hospital, Uburu in Ebonyi State, Nigeria were undertaken. The data were analysed using Humphreys' neutral temperature formula, descriptive statistics and multiple regression analysis.

Findings

The results revealed that the neutral temperature for the wards ranges from 26.2 °C to 29.9 °C, the thermal condition in the wards was not comfortable because it failed to meet the ASHRAE Standard 55 as only 65% of the occupants said the thermal condition was acceptable. The number and sizes of windows, building orientation, the presence of high-level windows and higher headroom significantly influenced the occupants' thermal comfort vote.

Practical implications

This research is valuable in estimating comfort temperature and identifying aspects that require attention in enhancing the capacity of NVH wards to effectively meet the thermal comfort needs of occupants in the hot-humid tropics of Southeast Nigeria and other regions that share similar climatic conditions.

Originality/value

To the best of the authors’ knowledge, this is the first study of this nature that provides valuable feedback for building design professionals on the performance of existing hospital buildings in meeting users' thermal comfort needs in the hot-dry season of the hot-humid tropics in Southeast Nigeria.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 16 May 2022

Olawale Olusoga and Olumuyiwa Adegun

The purpose of this study is to explore the perceptions of built environment professionals on the benefits and impediments limiting the widespread acceptance of vertical greening…

Abstract

Purpose

The purpose of this study is to explore the perceptions of built environment professionals on the benefits and impediments limiting the widespread acceptance of vertical greening systems (VGSs) in Lagos, Nigeria. This study contributes to the knowledge on the adoption of VGSs from the socio-technical dimension.

Design/methodology/approach

The study employed a survey method. An online questionnaire was used to obtain information from the respondents. The questionnaire was divided into four (4) sections. The first section focused on the socio-demographic variables while the second section addressed knowledge of VGSs, willingness to educate clients on the use of VGS and the possibility of VGS improving city image in Lagos. Section three (3) focused on the VGS benefits, subdivided into environmental, economic and aesthetic qualities and measured on a five-point Likert scale. Lastly, section four (4) concentrated on the impediments to the use of VGS in Lagos.

Findings

Professionals are willing to adopt the use of VGSs if their clients agree to the benefits it delivers to occupants, the environment and the building fabric.

Originality/value

This paper fulfills an identified need to study the perceptions of professionals toward VGSs patronage.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

1 – 10 of 821