1 – 10 of over 2000Karl Hollaus, Susanne Bauer, Michael Leumüller and Christian Türk
Cables are ubiquitous in electronic-based systems. Electromagnetic emission of cables and crosstalk between wires is an important issue in electromagnetic compatibility and is to…
Abstract
Purpose
Cables are ubiquitous in electronic-based systems. Electromagnetic emission of cables and crosstalk between wires is an important issue in electromagnetic compatibility and is to be minimized in the design phase. To facilitate the design, models of different complexity and accuracy, for instance, circuit models or finite element (FE) simulations, are used. The purpose of this study is to compare transmission line parameters obtained by measurements and simulations.
Design/methodology/approach
Transmission line parameters were determined by means of measurements in the frequency and time domain and by FE simulations in the frequency domain and compared. Finally, a Spice simulation with lumped elements was performed.
Findings
The determination of the effective permittivity of insulated wires seems to be a key issue in comparing measurements and simulations.
Originality/value
A space decomposition technique for a guided wave on an infinite configuration with constant cross-section has been introduced, where an analytic representation in the direction of propagation is used, and the transversal fields are approximated by FEs.
Details
Keywords
Johann Wilhelm and Werner Renhart
The purpose of this paper is to investigate an alternative to established hysteresis models.
Abstract
Purpose
The purpose of this paper is to investigate an alternative to established hysteresis models.
Design/methodology/approach
Different mathematical representations of the magnetic hysteresis are compared and some differences are briefly discussed. After this, the application of the T(x) function is presented and an inductor model is developed. Implementation details of the used transient circuit simulator code are further discussed. From real measurement results, parameters for the model are extracted. The results of the final simulation are finally discussed and compared to measurements.
Findings
The T(x) function possesses a fast mathematical formulation with very good accuracy. It is shown that this formulation is very well suited for an implementation in transient circuit simulator codes. Simulation results using the developed model are in very good agreement with measurements.
Research limitations/implications
For the purpose of this paper, only soft magnetic materials were considered. However, literature suggests, that the T(x) function can be extended to hard magnetic materials. Investigations on this topic are considered as future work.
Originality/value
While the mathematical background of the T(x) function is very well presented in the referenced papers, the application in a model of a real device is not very well discussed yet. The presented paper is directly applicable to typical problems in the field of power electronics.
Details
Keywords
Vahid Badeli, Sascha Ranftl, Gian Marco Melito, Alice Reinbacher-Köstinger, Wolfgang Von Der Linden, Katrin Ellermann and Oszkar Biro
This paper aims to introduce a non-invasive and convenient method to detect a life-threatening disease called aortic dissection. A Bayesian inference based on enhanced…
Abstract
Purpose
This paper aims to introduce a non-invasive and convenient method to detect a life-threatening disease called aortic dissection. A Bayesian inference based on enhanced multi-sensors impedance cardiography (ICG) method has been applied to classify signals from healthy and sick patients.
Design/methodology/approach
A 3D numerical model consisting of simplified organ geometries is used to simulate the electrical impedance changes in the ICG-relevant domain of the human torso. The Bayesian probability theory is used for detecting an aortic dissection, which provides information about the probabilities for both cases, a dissected and a healthy aorta. Thus, the reliability and the uncertainty of the disease identification are found by this method and may indicate further diagnostic clarification.
Findings
The Bayesian classification shows that the enhanced multi-sensors ICG is more reliable in detecting aortic dissection than conventional ICG. Bayesian probability theory allows a rigorous quantification of all uncertainties to draw reliable conclusions for the medical treatment of aortic dissection.
Originality/value
This paper presents a non-invasive and reliable method based on a numerical simulation that could be beneficial for the medical management of aortic dissection patients. With this method, clinicians would be able to monitor the patient’s status and make better decisions in the treatment procedure of each patient.
Details
Keywords
Abstract
Details
Keywords
Manuel E. Rademaker, Florian Schuberth and Theo K. Dijkstra
The purpose of this paper is to enhance consistent partial least squares (PLSc) to yield consistent parameter estimates for population models whose indicator blocks contain a…
Abstract
Purpose
The purpose of this paper is to enhance consistent partial least squares (PLSc) to yield consistent parameter estimates for population models whose indicator blocks contain a subset of correlated measurement errors.
Design/methodology/approach
Correction for attenuation as originally applied by PLSc is modified to include a priori assumptions on the structure of the measurement error correlations within blocks of indicators. To assess the efficacy of the modification, a Monte Carlo simulation is conducted.
Findings
In the presence of population measurement error correlation, estimated parameter bias is generally small for original and modified PLSc, with the latter outperforming the former for large sample sizes. In terms of the root mean squared error, the results are virtually identical for both original and modified PLSc. Only for relatively large sample sizes, high population measurement error correlation, and low population composite reliability are the increased standard errors associated with the modification outweighed by a smaller bias. These findings are regarded as initial evidence that original PLSc is comparatively robust with respect to misspecification of the structure of measurement error correlations within blocks of indicators.
Originality/value
Introducing and investigating a new approach to address measurement error correlation within blocks of indicators in PLSc, this paper contributes to the ongoing development and assessment of recent advancements in partial least squares path modeling.
Details
Keywords
Dennis Albert, Lukas Daniel Domenig, Philipp Schachinger, Klaus Roppert and Herwig Renner
The purpose of this paper is to investigate the applicability of a direct current (DC) hysteresis measurement on power transformer terminals for the subsequent hysteresis model…
Abstract
Purpose
The purpose of this paper is to investigate the applicability of a direct current (DC) hysteresis measurement on power transformer terminals for the subsequent hysteresis model parametrization in transformer grey box topology models.
Design/methodology/approach
Two transformer topology models with two different hysteresis models are used together with a DC hysteresis measurement via the power transformer terminals to parameterize the hysteresis models by means of an optimization. The calculated current waveform with the derived model in the transformer no-load condition is compared to the measured no-load current waveforms to validate the model.
Findings
The proposed DC hysteresis measurement via the power transformer terminals is suitable to parametrize two hysteresis models implemented in transformer topology models to calculate the no-load current waveforms.
Originality/value
Different approaches for the measurement and utilization of transformer terminal measurements for the hysteresis model parametrization are discussed in literature. The transformer topology models, derived with the presented approach, are able to reproduce the transformer no-load current waveform with acceptable accuracy.
Details
Keywords
Values of parameters such as temperature, humidity, number of plastic products and the location of plastic injection moulds are required to determine the efficiency of plastic…
Abstract
Purpose
Values of parameters such as temperature, humidity, number of plastic products and the location of plastic injection moulds are required to determine the efficiency of plastic injection moulds with a view to improving the quality of the outputs. This article determined the appropriate sensors for the measurement of these essential parameters in the most suitable form of representation of the data to aid a proficient analysis of the data.
Design/methodology/approach
The outputs of these sensors were obtained by connecting the sensors to the general-purpose input/output (GPIO) pins of a Raspberry Pi and writing a Python programme for the connected GPIO pins. The values of the outputs of these sensors were represented in a graphical form. The connection of the Raspberry Pi and the sensors were done with a full-sized breadboard and jumper wires. A computer-aided design (CAD) of the connections was produced using Fritzing software.
Findings
The appropriate sensors determined are MLX90614 infrared thermometer sensor, DHT11 humidity sensor, pixy2 vision sensor and Neo-6m GPS sensor. This study proposed that the sensors analytic system be applied on an industrial plastic injection mould to measure and display the various parameters of the injection moulds for the purpose of understanding and improving the performance of the injection mould
Originality/value
An electronic system that provides the continuous values of essential parameters of a plastic injection mould in operation.
Details
Keywords
Wael Amin Nasr El-Din, Mona Hassan Mohammed Ali, Gisma Ahmed Madani and Islam Omar Abdel Fattah
Sex and age estimation is important, particularly when information about the deceased is unavailable. There are limited radiological studies investigating side, sex and age…
Abstract
Purpose
Sex and age estimation is important, particularly when information about the deceased is unavailable. There are limited radiological studies investigating side, sex and age differences in normal ankle morphometric parameters. The authors’ goal was to evaluate different ankle joint morphometric measurements and document variations among Egyptians.
Design/methodology/approach
A prospective study was conducted throughout 23 months on 203 (100 males and 103 females) adult Egyptians, aged between 20-69 years old, who were referred for a plain x-ray of bilateral normal ankle joints.
Findings
Ankle parameters showed no statistical difference between both sides, except for tarsal width (TaW) which was significantly higher on right than left side (26.92 ± 2.66 vs 26.18 ± 2.65 mm). Males showed significantly higher morphometric values except for anteroposterior gap (APG) and talus height (TaH) which were significantly higher in females (2.29 ± 0.80 vs 1.80 ± 0.61 mm and 13.01 ± 1.68 vs 11.87 ± 1.91 mm, respectively). There was significant increase in tibial arc length, APG, distance of level of MTiTh from anterior limit of mortise, distance of level of MTiTh from vertex of mortise, sagittal distance between tibial and talar vertices and sagittal radius of trochlea tali arc in old age group compared to young one. A significant decrease in tibial width, malleolar width, TaW and TaH was noted in old age group compared to young one.
Originality/value
Ankle joints of both sides are mostly symmetrical; however, there are significant differences in most morphometric values due to sex and age factors. These findings may be essential during side, sex and age determination.
Details
Keywords
Aicha Gasmi, Marc Heran, Noureddine Elboughdiri, Lioua Kolsi, Djamel Ghernaout, Ahmed Hannachi and Alain Grasmick
The main purpose of this study resides essentially in the development of a new tool to quantify the biomass in the bioreactor operating under steady state conditions.
Abstract
Purpose
The main purpose of this study resides essentially in the development of a new tool to quantify the biomass in the bioreactor operating under steady state conditions.
Design/methodology/approach
Modeling is the most relevant tool for understanding the functioning of some complex processes such as biological wastewater treatment. A steady state model equation of activated sludge model 1 (ASM1) was developed, especially for autotrophic biomass (XBA) and for oxygen uptake rate (OUR). Furthermore, a respirometric measurement, under steady state and endogenous conditions, was used as a new tool for quantifying the viable biomass concentration in the bioreactor.
Findings
The developed steady state equations simplified the sensitivity analysis and allowed the autotrophic biomass (XBA) quantification. Indeed, the XBA concentration was approximately 212 mg COD/L and 454 mgCOD/L for SRT, equal to 20 and 40 d, respectively. Under the steady state condition, monitoring of endogenous OUR permitted biomass quantification in the bioreactor. Comparing XBA obtained by the steady state equation and respirometric tool indicated a percentage deviation of about 3 to 13%. Modeling bioreactor using GPS-X showed an excellent agreement between simulation and experimental measurements concerning the XBA evolution.
Originality/value
These results confirmed the importance of respirometric measurements as a simple and available tool for quantifying biomass.