Indira Damarla, Venmathi M., Krishnakumar V. and Anbarasan P.

In this paper, a new front end converter (FEC) topology has been proposed for the switched reluctance (SR) motor drive. This study aims to present the performance analysis of…

Abstract

Purpose

In this paper, a new front end converter (FEC) topology has been proposed for the switched reluctance (SR) motor drive. This study aims to present the performance analysis of FEC-based SR motor drive using various types of control schemes like conventional proportional integral (PI) controller, fuzzy logic controller (FLC) and fuzzy-tuned proportional integral controller (Fuzzy-PI).

Design/methodology/approach

The proposed FEC-based SR motor drive with various control strategies is derived for the torque ripple minimization and speed control.

Findings

The steady state and the dynamic response of the FEC-based SR motor drive are analyzed using three different controllers under change in speed and loading conditions. The Fuzzy-PI-based control scheme improves the dynamic response of the system when compared with the FLC and the conventional PI controller.

Originality/value

The hardware prototype has been implemented for the FEC-based SR motor drive by using the Xilinx SPARTAN 6 FPGA processor. The experimental verification has been conducted and the results have been measured under steady state and dynamic conditions.

Details

Circuit World, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0305-6120

Keywords

Article
Publication date: 15 September 2023

Prabhakaran Koothu Kesavan, Umashankar Subramaniam and Dhafer Jaber Almakhles

This paper aims to present a cascaded pseudo derivative feedback (PDF) plus pseudo derivative feedback plus pseudo derivative feedforward (PDFF) controller for a permanent magnet…

Abstract

Purpose

This paper aims to present a cascaded pseudo derivative feedback (PDF) plus pseudo derivative feedback plus pseudo derivative feedforward (PDFF) controller for a permanent magnet synchronous motor (PMSM) to improve the transient response of the system.

Design/methodology/approach

Proportional integral (PI) plus PI controller and the proposed PDF plus PDFF controller are designed, stability analysis is performed using the extended root locus method, and the effect of the damping coefficient is also extensively studied to validate the robustness of the proposed controller.

Findings

When compared to a cascaded PI plus PI controller, the proposed control approach has a much shorter settling time for the entire system and a 50% reduction in overshoot in stator current under extensive variations in speed with load disturbance.

Originality/value

The proposed controller is programmed into an FPGA Altera Cyclone II and applied to a 1.5 kW laboratory prototype PMSM drive. The effectiveness of the proposed methods has been demonstrated experimentally throughout a wide variable speed range, from 0 to 157 rad/s at different load conditions.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. 42 no. 6
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 1 April 2022

Shrabani Sahu and Sasmita Behera

The wind turbine (WT) is a complex system subjected to wind disturbances. Because the aerodynamics is nonlinear, the control is thus challenging. For the variation of wind speed…

Abstract

Purpose

The wind turbine (WT) is a complex system subjected to wind disturbances. Because the aerodynamics is nonlinear, the control is thus challenging. For the variation of wind speed when rated power is delivered at rated wind speed, the power is limited to the rate by the pitching of the blades of the turbine. This paper aims to address pitch control with the WT benchmark model. The possible use of appropriate adaptive controller design that modifies the control action automatically identifying any change in system parameters is explored.

Design/methodology/approach

To deal with pitch control problem when wind speed exceeds the rated wind speed of the WT, six digital self-tuning controller (STC) with different structures such as proportional integral (PI), proportional derivative (PD), Dahlin’s, pole placement, deadbeat and Takahashi has been taken herein. The system model is identified as a second-order autoregressive exogenous (ARX) model by three techniques for comparison: recursive least square method (RLS), RLS with exponential forgetting and RLS with adaptive directional forgetting identification methods. A comparative study of three identification methods, six adaptive controllers with the conventional PI controller and sliding mode controller (SMC), are shown.

Findings

As per the results, the best improvement in control of the output power by pitching in full load region of benchmark model is achieved by self-tuning PD controller based on RLS with adaptive directional forgetting method. The adaptive control design has a future in WT control applications.

Originality/value

A comparative study of identification methods, six adaptive controllers with the conventional PI controller and SMC, are shown here. As per the results, the best improvement in control of the output power by pitching in the full load region of the benchmark model has been achieved by self-tuning PD controller. The best identification method or the system is RLS with an adaptive directional forgetting method. Instead of a step input response design for the controllers, the controller design has been carried out for the stochastic wind and the performance is adjudged by the normalized sum of square tracking error (NSSE) index. The validation of the proposed self-tuning PD controller has been shown in comparison to the conventional controller with Monte-Carlo analysis to handle model parameter alteration and erroneous measurement issues.

Details

World Journal of Engineering, vol. 20 no. 4
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 27 December 2022

Salma Jnayah and Adel Khedher

The direct torque control (DTC) of induction motor (IM) drive is featured by high ripples in the electromagnetic torque and stator flux profiles because they are controlled by two…

Abstract

Purpose

The direct torque control (DTC) of induction motor (IM) drive is featured by high ripples in the electromagnetic torque and stator flux profiles because they are controlled by two hysteresis regulators. Furthermore, the machine flux is not directly measurable. Hence, it is better to reconstitute it from the instantaneous electrical equations of the machine. Once the stator flux is estimated, we can guarantee a reliable sensorless DTC control. Thus, the purpose of this research work is to ensure fast response and full reference tracking of the IM under sensorless DTC strategy with desired dynamic behavior and low ripple levels.

Design/methodology/approach

In this work, an improved DTC strategy, which is DTC_SVM_3L, is suggested. The first step of the designed approach is to substitute the conventional inverter feeding the motor with a three-level inverter because it guarantees reduced switching losses, improved quality of voltage waveform and low-current total harmonic distortion rate. The second aim of this paper is to make the IM operate at a constant switching frequency by using the nearest three vectors-based space vector modulation (SVM) technique rather than hysteresis controllers. The third objective of this study is to conceive a sliding-mode stator flux observer, which can improve the control performances by using a sensorless algorithm to get an accurate estimation, and consequently, increase the reliability of the system and decrease the cost of using sensors. The stability of the proposed observer is demonstrated based on the Lyapunov theory. To overcome the load change disturbance in the proposed DTC control strategy, this paper exhibits a comparative assessment of four speed regulation methods: classical proportional and integral (PI) regulator, fuzzy logic PI controller, particle swarm optimization PI controller and backstepping regulator. The entire control algorithm was tested under different disturbances such as stator resistance and load torque variations.

Findings

It was ascertained that the IM, controlled with three-level inverter, exhibits good performances under the proposed DTC-SVM strategy based on a sliding-mode observer. The robustness of the suggested approach against parameter variations is also proved.

Originality/value

The theoretical development of the proposed control strategy is thoroughly described. Then, simulations using Matlab/Simulink software are launched to investigate the merits of the sensorless DTC-SVM command of three-level inverter-fed IM drive with different speed regulators.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering , vol. 42 no. 6
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 4 August 2022

Biranchi Narayan Kar, Paulson Samuel, Jatin Kumar Pradhan and Amit Mallick

This paper aims to present an improvement to the power quality of the grid by using a colliding body optimization (CBO) based proportional-integral (PI) compensated design for a…

Abstract

Purpose

This paper aims to present an improvement to the power quality of the grid by using a colliding body optimization (CBO) based proportional-integral (PI) compensated design for a grid-connected solar photovoltaic-fed brushless DC motor (BLDC)-driven water pumping system with a bidirectional power flow control. The system with bidirectional power flow allows driving the pump at full proportions uninterruptedly irrespective of the weather conditions and feeding a grid when water pumping is not required.

Design/methodology/approach

Here, power quality issue is taken care of by the optimal generation of the duty cycle of the voltage source converter. The duty cycle is optimally generated by optimal selection of the gains of the current controller (i.e. PI), with the CBO technique resulting in a nearly unity power factor as well as lower total harmonic distortion (THD) of input current. In the CBO technique, the gains of the PI controller are considered as agents and collide with each other to obtain the best value. The system is simulated using MATLAB/Simulink and validated in real time with OPAL RT simulator, OP5700.

Findings

It was found that the power quality of grid using the CBO technique has improved much better than the particle swarm optimization and Zeigler–Nichols approach. The bidirectional flow of control of VSC allowed for optimum resource utilization and full capacity of water pumping whatever may be weather conditions.

Originality/value

Improved power quality of grid by optimally generation of the duty cycle for the proposed system. A unit vector tamplate generation technique is used for bidirectional power transfer.

Article
Publication date: 14 February 2023

Martin Karlsson, Fredrik Bagge Carlson, Martin Holmstrand, Anders Robertsson, Jeroen De Backer, Luisa Quintino, Eurico Assuncao and Rolf Johansson

This study aims to enable robotic friction stir welding (FSW) in practice. The use of robots has hitherto been limited, because of the large contact forces necessary for FSW…

Abstract

Purpose

This study aims to enable robotic friction stir welding (FSW) in practice. The use of robots has hitherto been limited, because of the large contact forces necessary for FSW. These forces are detrimental for the position accuracy of the robot. In this context, it is not sufficient to rely on the robot’s internal sensors for positioning. This paper describes and evaluates a new method for overcoming this issue.

Design/methodology/approach

A closed-loop robot control system for seam-tracking control and force control, running and recording data in real-time operation, was developed. The complete system was experimentally verified. External position measurements were obtained from a laser seam tracker and deviations from the seam were compensated for, using feedback of the measurements to a position controller.

Findings

The proposed system was shown to be working well in overcoming position error. The system is flexible and reconfigurable for batch and short production runs. The welds were free of defects and had beneficial mechanical properties.

Research limitations/implications

In the experiments, the laser seam tracker was used both for control feedback and for performance evaluation. For evaluation, it would be better to use yet another external sensor for position measurements, providing ground truth.

Practical implications

These results imply that robotic FSW is practically realizable, with the accuracy requirements fulfilled.

Originality/value

The method proposed in this research yields very accurate seam tracking as compared to previous research. This accuracy, in turn, is crucial for the quality of the resulting material.

Details

Industrial Robot: the international journal of robotics research and application, vol. 50 no. 5
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 7 July 2023

Vinayambika S. Bhat, Thirunavukkarasu Indiran, Shanmuga Priya Selvanathan and Shreeranga Bhat

The purpose of this paper is to propose and validate a robust industrial control system. The aim is to design a Multivariable Proportional Integral controller that accommodates…

97

Abstract

Purpose

The purpose of this paper is to propose and validate a robust industrial control system. The aim is to design a Multivariable Proportional Integral controller that accommodates multiple responses while considering the process's control and noise parameters. In addition, this paper intended to develop a multidisciplinary approach by combining computational science, control engineering and statistical methodologies to ensure a resilient process with the best use of available resources.

Design/methodology/approach

Taguchi's robust design methodology and multi-response optimisation approaches are adopted to meet the research aims. Two-Input-Two-Output transfer function model of the distillation column system is investigated. In designing the control system, the Steady State Gain Matrix and process factors such as time constant (t) and time delay (?) are also used. The unique methodology is implemented and validated using the pilot plant's distillation column. To determine the robustness of the proposed control system, a simulation study, statistical analysis and real-time experimentation are conducted. In addition, the outcomes are compared to different control algorithms.

Findings

Research indicates that integral control parameters (Ki) affect outputs substantially more than proportional control parameters (Kp). The results of this paper show that control and noise parameters must be considered to make the control system robust. In addition, Taguchi's approach, in conjunction with multi-response optimisation, ensures robust controller design with optimal use of resources. Eventually, this research shows that the best outcomes for all the performance indices are achieved when Kp11 = 1.6859, Kp12 = −2.061, Kp21 = 3.1846, Kp22 = −1.2176, Ki11 = 1.0628, Ki12 = −1.2989, Ki21 = 2.454 and Ki22 = −0.7676.

Originality/value

This paper provides a step-by-step strategy for designing and validating a multi-response control system that accommodates controllable and uncontrollable parameters (noise parameters). The methodology can be used in any industrial Multi-Input-Multi-Output system to ensure process robustness. In addition, this paper proposes a multidisciplinary approach to industrial controller design that academics and industry can refine and improve.

Details

Journal of Engineering, Design and Technology , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 8 April 2022

Bhanu Prakash Saripalli, Gagan Singh and Sonika Singh

Non-linear power–voltage characteristics of solar cell and frequently changing output due to variation in solar irradiance caused by movement of clouds are the major issues need…

Abstract

Purpose

Non-linear power–voltage characteristics of solar cell and frequently changing output due to variation in solar irradiance caused by movement of clouds are the major issues need to be considered in photovoltaic (PV) penetration to maintain the power quality of the grid. It is important for a PV module to always function at its maximum available power point to increase the efficiency and to maintain the grid stability. A possible solution to mitigate these generation fluctuations is the use of an electric double-layer capacitor or supercapacitor energy storage device, which is an efficient storage device for power smoothing applications. This study aims to propose a power smoothing control approach to smoothen out the output power variations of a solar PV system using a supercapacitor energy storage device.

Design/methodology/approach

To extract the maximum possible power from a PV panel, there are several maximum power points tracking (MPPT) algorithms developed in literature. Fuzzy logic controller-MPPT method is used in this work as it is a very efficient and popular technique which responds quickly under varying ecological conditions, reduced computational complexity and does not depend on any system constraints. Fuzzy logic-based MPPT controller by Boost DC–DC converter is developed for operating the PV panels at available maximum power point. Fuzzy logic-proportional integral (PI) charge controller is implemented by Buck–Boost converter to provide the constant current and suitable voltage for supercapacitor and to achieve better power smoothing. PI charge controller is preferred in this work as it offers better outcomes and is very easy to implement.

Findings

Simulation results conclude that the proposed power smoothing control approach can efficiently smooth out the power variations under variable irradiance and temperature situations. To confirm the accurateness of the proposed system, it is validated for poly-crystalline PV module and comparison of results is done by using different case study with and without the use of an energy storage system under change in irradiance condition. The proposed system is developed and examined on MATLAB/Simulink environment.

Originality/value

The performance comparison between PV power output with and without the use of a supercapacitor energy storage device under different Case Studies shows that the improved performance in smoothing of power output was achieved with the use of a supercapacitor energy storage device.

Article
Publication date: 29 September 2022

Yifeng Zhu, Ziyang Zhang, Hailong Zhao and Shaoling Li

Five-level rectifiers have received widespread attention because of their excellent performance in high-voltage and high-power applications. Taking a five-level rectifier with…

Abstract

Purpose

Five-level rectifiers have received widespread attention because of their excellent performance in high-voltage and high-power applications. Taking a five-level rectifier with only four-IGBT for this study, a sliding mode predictive control (SMPC) algorithm is proposed to solve the problem of poor dynamic performance and poor anti-disturbance ability under the traditional model predictive control with the PI outer loop.

Design/methodology/approach

First, mathematical models under the two-phase stationary coordinate system and two-phase synchronous rotating coordinate system are established. Then, the design of the outer-loop sliding mode controller is completed by establishing the sliding mode surface and design approach rate. The design of the inner-loop model predictive controller was completed by discretizing the mathematical model equations. The modulation part uses a space vector modulation technique to generate the PWM wave.

Findings

The sliding mode predictive control strategy is compared with the control strategy with a PI outer loop and a model predictive inner loop. The proposed control strategy has a faster dynamic response and stronger anti-interference ability.

Originality/value

For the five-level rectifier, the advantages of fast dynamic influence and parameter insensitivity of sliding mode control are used in the voltage outer loop to replace the traditional PI control, and which is integrated with the model predictive control used in the current inner loop to form a novel control strategy with a faster dynamic response and stronger immunity to disturbances. This novel strategy is called sliding mode predictive control (SMC).

Details

Circuit World, vol. 50 no. 1
Type: Research Article
ISSN: 0305-6120

Keywords

Article
Publication date: 30 March 2022

Karthick R., Ramakrishnan C. and Sridhar S.

This paper aims to introduce the quasi impedance source inverter (qZSI)-based static compensator (STATCOM), which is incorporated into the hybrid distributed power generation…

Abstract

Purpose

This paper aims to introduce the quasi impedance source inverter (qZSI)-based static compensator (STATCOM), which is incorporated into the hybrid distributed power generation system for enhancement of power quality. The distributed power generation system includes the photovoltaic (PV), wind energy conversion system (WECS) and battery energy storage system.

Design/methodology/approach

The WECS is used by the self-excited induction generator (SEIG) and the flywheel energy storage system (FESS). To regulate its terminal voltage and frequency, the SEIG requires adjustable volt-ampere reactive (VAR). A combination of a STATCOM and a fixed condenser bank usually serves to satisfy the VAR demand. The maximum correntropy criterion-based adaptive filter technique (AFT) is proposed to control the qZSI-STATCOM and to guarantee that the voltage at the SEIG terminal is harmonic-free while providing non-linear three-phase and single-phase loads.

Findings

The coordinated operation of the suggested voltage control and flywheel control systems ensures that load voltage and frequency are retained in their respective values at very low harmonic distortions regardless of wind speed and load variation. The simulation and experimental studies are carried out under different load conditions to validate the efficiencies of the PV-assisted STATCOM.

Originality/value

To improve system stability and minimize total costs, extra load current sensors can also be avoided. This paper proposes to control the SEIG terminal voltage and harmonic elimination in the standalone WECS systems using maximum correntropy criterion-based AFT with a fuzzy logic controller.

1 – 10 of 85