Search results

11 – 20 of over 4000
Article
Publication date: 1 March 1990

Elzbieta Marszalec and Janusz Marszalec

Integration of lasers and fibre optics into robotic systems provides new opportunities in sensing and material processing. Increased productivity and application of robots in…

Abstract

Integration of lasers and fibre optics into robotic systems provides new opportunities in sensing and material processing. Increased productivity and application of robots in hostile environments are other possibilities.

Details

Industrial Robot: An International Journal, vol. 17 no. 3
Type: Research Article
ISSN: 0143-991X

Article
Publication date: 1 December 2017

Shaoyi Xu, Fangfang Xing, Ruilin Wang, Wei Li, Yuqiao Wang and Xianghui Wang

At present, one of the key equipment in pillar industries is a large rotating machinery. Conducting regular health monitoring is important for ensuring safe operation of the large…

869

Abstract

Purpose

At present, one of the key equipment in pillar industries is a large rotating machinery. Conducting regular health monitoring is important for ensuring safe operation of the large rotating machinery. Because vibrations sensors play an important role in the workings of the rotating machinery, measuring its vibration signal is an important task in health monitoring. This paper aims to present these.

Design/methodology/approach

In this work, the contact vibration sensor and the non-contact vibration sensor have been discussed. These sensors consist of two types: the electric vibration sensor and the optical fiber vibration sensor. Their applications in the large rotating machinery for the purpose of health monitoring are summarized, and their advantages and disadvantages are also presented.

Findings

Compared with the electric vibration sensor, the optical fiber vibration sensor of large rotating machinery has unique advantages in health monitoring, such as provision of immunity against electromagnetic interference, requirement of less insulation and provision of long-distance signal transmission.

Originality/value

Both contact vibration sensor and non-contact vibration sensor have been discussed. Among them, the electric vibration sensor and the optical fiber vibration sensor are compared. Future research direction of the vibration sensors is presented.

Details

Sensor Review, vol. 38 no. 1
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 1 March 1994

Andrew G Rickman

A review of integrated optical circuit technologies [OIC] and theirrelevance to potential OIC sensor application. Describes the manufacture ofOICs and the varied range of material…

367

Abstract

A review of integrated optical circuit technologies [OIC] and their relevance to potential OIC sensor application. Describes the manufacture of OICs and the varied range of material technologies used. Active Silicon Integrated Optical Circuits have been developed which may have applications for many optical sensor and fibre optic sensor systems. Concludes however that silicon integrated optics will not enjoy large‐scale success until their manufacturing costs have been dramatically reduced.

Details

Sensor Review, vol. 14 no. 1
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 1 March 1998

Vincent A. Handerek

Optical fibre multiplexed sensors are used to make measurements at multiple, discrete locations, usually by sending optical signals between each measurement location and a…

668

Abstract

Optical fibre multiplexed sensors are used to make measurements at multiple, discrete locations, usually by sending optical signals between each measurement location and a conveniently positioned optical interrogation instrument. It is rapidly becoming practical to construct multiplexed optical fibre sensor arrays based on in‐fibre Bragg gratings. A Bragg grating can be produced in an optical fibre by writing a periodic variation in the refractive index of the fibre’s core along the axis, using ultra‐violet light. Multiplexing applications will appear ranging from the small scale, with only a few sensors, up to very large scales with hundreds of sensors.

Details

Sensor Review, vol. 18 no. 1
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 14 June 2013

Yage Zhan, Kan Gu, Hua Wu and Jun Luo

The on‐line concentration and temperature measurement of solutions is of great interest as a means of quality production control in many industrial processes, such as in food…

Abstract

Purpose

The on‐line concentration and temperature measurement of solutions is of great interest as a means of quality production control in many industrial processes, such as in food service industry, pharmaceuticals industry, chemical industry and environmental engineering, especially for harmful solutions or solutions that cannot be reached by the operator. This paper seeks to address these issues.

Design/methodology/approach

A high resolution all‐fiber multi‐parameter sensor system has been studied theoretically and experimentally. The sensor system can be used for on‐line monitoring of concentration and temperature simultaneously and dynamically. A combined long period fiber grating (CLPG) is used as the sensor head based on its resonance wavelength shifts being almost linearly with concentration and temperature, and also based on that the two applied resonance peaks have different concentration‐wavelength coefficients and different temperature‐wavelength coefficients. Two wavelength‐matched fiber Bragg gratings (FBGs) are used to convert resonance peak wavelengths of the CLPG into corresponding intensities for interrogation.

Findings

When the concentration and the temperature all fluctuate dynamically during experiments, a concentration resolution of 0.03 g/L has been achieved in the range of 0∼200 g/L, and a temperature resolution of 0.02C has been realized in the range of −20∼60C.

Originality/value

On‐line monitoring of concentration and temperature for solutions is a means of quality production control in biological, chemical and other many industrial processes, such as in food service industry, pharmaceuticals industry, chemical industry, and also in environmental engineering, especially for harmful solutions or solutions that cannot be reached by the operator. Optical fiber sensors have numerous advantages over traditional sensors, such as immunity to electromagnetic interference, higher stability and sensitivity, more easiness of multiplex, being competent for application in harsh environments, “smart structures” and on‐site measurements. Long period optical fiber grating sensor is the most appropriate sensor for multi‐parameter monitoring in the fields mentioned above, which has all the advantages of optical fiber sensor. Besides, optical fiber grating sensors can be used for monitoring more accurately because its signal is coded by wavelength. The all‐fiber sensor system is suitable for remote monitoring of many solutions, such as the solutions of NaCl, glucose, alcohol, and hydrocarbon.

Details

Sensor Review, vol. 33 no. 3
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 28 March 2008

S. O'Keeffe, C. Fitzpatrick, E. Lewis and A.I. Al‐Shamma'a

The purpose of this paper is to provide a detailed review of radiation dosimetry techniques based on optical fibre dosimeters. It presents a comprehensive bibliography of the…

2879

Abstract

Purpose

The purpose of this paper is to provide a detailed review of radiation dosimetry techniques based on optical fibre dosimeters. It presents a comprehensive bibliography of the current research activities in the area.

Design/methodology/approach

A range of published work on optical fibre radiation dosimeters are presented, with the merits and limitations discussed. Each radiation dosimetry technique is discussed in turn, providing examples of dosimeters using such techniques reviewed. The main focus is on gamma radiation although other radiation dosimeters are considered.

Findings

This paper provides information on the wide range of research activity into radiation dosimeters. The dose ranges of these dosimeters are presented, along with the advantages and disadvantages of different dosimetry techniques.

Originality/value

A comprehensive review of published research in the area of solid radiation dosimetry is presented in this paper. It provides an individual with a review of the various techniques used and most recent research in that field.

Details

Sensor Review, vol. 28 no. 2
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 18 January 2016

Jun Ni, Jifei Dong, Jingchao Zhang, Fangrong Pang, Weixing Cao and Yan Zhu

– The purpose of this paper is to improve the accuracy and signal-to-noise ratio (SN) of a crop nitrogen sensor.

Abstract

Purpose

The purpose of this paper is to improve the accuracy and signal-to-noise ratio (SN) of a crop nitrogen sensor.

Design/methodology/approach

The accuracy and wide adaptability of two spectral calibration methods for a crop nitrogen sensor based on standard reflectivity gray plates and standard detector, respectively, were compared.

Findings

The calibration method based on standard detector could significantly improve the measurement accuracy and the SN of this crop nitrogen sensor. When compared with the method based on standard gray plates, the measurement accuracy and the SN of the crop nitrogen sensor calibrated based on the standard detector method improved by 50 and 10 per cent, respectively.

Originality/value

This research analysed the calibration problems faced by the crop nitrogen sensor (type CGMD302) based on standard gray plates, and proposed a sensor calibration method based on a standard detector. Finally, the results of the two calibration methods were compared in terms of measurement accuracy and the SN of the crop nitrogen sensor.

Details

Sensor Review, vol. 36 no. 1
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 23 January 2009

Ruzairi Abdul Rahim, Chiam Kok Thiam, Jaysuman Pusppanathan and Yvette Shaan‐Li Susiapan

The purpose of this paper is to view the flow concentration of the flowing material in a pipeline conveyor.

Abstract

Purpose

The purpose of this paper is to view the flow concentration of the flowing material in a pipeline conveyor.

Design/methodology/approach

Optical tomography provides a method to view the cross sectional image of flowing materials in a pipeline conveyor. Important flow information such as flow concentration profile, flow velocity and mass flow rate can be obtained without the need to invade the process vessel. The utilization of powerful computer together with expensive data acquisition system (DAQ) as the processing device in optical tomography systems has always been a norm. However, the advancements in silicon fabrication technology nowadays allow the fabrication of powerful digital signal processors (DSP) at reasonable cost. This allows the technology to be applied in optical tomography system to reduce or even eliminate the need of personal computer and the DAQ. The DSP system was customized to control the data acquisition of 16 × 16 optical sensors (arranged in orthogonal projection) and 23 × 23 optical sensors (arranged in rectilinear projections). The data collected were used to reconstruct the cross sectional image of flowing materials inside the pipeline. In the developed system, the accuracy of the image reconstruction was increased by 12.5 per cent by using new hybrid image reconstruction algorithm.

Findings

The results proved that the data acquisition and image reconstruction algorithm is capable of acquiring accurate data to reconstruct cross sectional images with only little error compared to the expected measurements.

Originality/value

The DSP system was customized to control the data acquisition of 16 × 16 optical sensors (arranged in orthogonal projection) and 23 × 23 optical sensors (arranged in rectilinear projections).

Details

Sensor Review, vol. 29 no. 1
Type: Research Article
ISSN: 0260-2288

Keywords

Article
Publication date: 1 January 1989

Peter McGeehin

Optical sensor companies in the UK are getting together to organise their own research and development.

Abstract

Optical sensor companies in the UK are getting together to organise their own research and development.

Details

Sensor Review, vol. 9 no. 1
Type: Research Article
ISSN: 0260-2288

Article
Publication date: 3 February 2021

Xinjie Zhang, Fansen Kong, Zhiyuan Gu and Xiao Shen

FOV splicing optical remote sensing instruments have a strict requirement for the focal length consistency of the lens. In conventional optical-mechanical structure design, each…

Abstract

Purpose

FOV splicing optical remote sensing instruments have a strict requirement for the focal length consistency of the lens. In conventional optical-mechanical structure design, each optical element is equally distributed with high accuracy and everyone must have a high machining and assembly accuracy. For optical remote sensors with a large number of optical elements, this design brings great difficulties to lens manufacture and alignment.

Design/methodology/approach

Taking the relay lens in an optical remote sensing instrument with the field of view splicing as an example, errors of the system are redistributed to optical elements. Two optical elements, which have the greatest influence on modulation transfer function (MTF) of the system are mounted with high accuracy centering and the other elements are fixed by gland ring with common machining accuracy. The reduction ratio consistency difference among lenses is compensated by adjusting the optical spacing between the two elements.

Findings

Based on optical system simulation analysis, the optimized structure can compensate for the difference of reduction ratio among lens by grinding the washer thickness in the range of ±0.37 mm. The test data for the image quality of the lens show that the MTF value declined 0.043 within ±0.4 mm of space change between two barrels. The results indicate that the reduction ratio can be corrected by adjusting the washer thickness and the image quality will not obviously decline.

Originality/value

This paper confirms that this work is original and has not been published elsewhere nor is it currently under consideration for publication elsewhere. In this paper, the optimum structural design of the reduction relay lens for the field of view stitching applications is reported. The method of adjusting washer thickness is applied to compensate for the reduction ratio consistency difference of lenses. The optimized structure also greatly reduces the difficulty of lenses manufacture, alignment and improves the efficiency of assembly.

Details

Sensor Review, vol. 41 no. 1
Type: Research Article
ISSN: 0260-2288

Keywords

11 – 20 of over 4000