Search results

1 – 10 of 252
Article
Publication date: 5 August 2022

Oti Amankwah, Weng-Wai Choong and Naana Amakie Boakye-Agyeman

Although the quality of health-care infrastructure and equipment influences patient’s overall health-care experience, health-care infrastructure and equipment are not always…

Abstract

Purpose

Although the quality of health-care infrastructure and equipment influences patient’s overall health-care experience, health-care infrastructure and equipment are not always managed and maintained with the attention required. This is due mainly to the complexity of health-care infrastructure and equipment and shortage of maintenance budget. This study aims to determine if patient’s satisfaction of core health-care business is mediated by the quality of health-care infrastructure and equipment.

Design/methodology/approach

This cross-sectional study comprises 622 adult patients at the Physician OPD and Polyclinic of Komfo Anokye Teaching hospital, Tamale Teaching hospital and Cape Coast Teaching hospital in Ghana. Structural equation model Smart PLS was used to analyse the data.

Findings

The study results showed that the quality of health-care infrastructure and equipment has a positive significant influence (mediation) on the relationship between health-care delivery and patient’s satisfaction as well as the relationship between adequacy of health-care resources and patient’s satisfaction. However, it was shown not to have a positive significant influence (mediation) on the relationship between quality of health-care personnel and patients’ satisfaction as well as health-care administrative process and patient’s satisfaction.

Research limitations/implications

First, the study findings are centred on cross-sectional data, which capture the opinion of the patients at a specific time period instead of over a period of time. Consequently, in future, though difficult to achieve, a longitudinal study can be piloted to provide more insight. Second, the data was collected from only one country (Ghana); thus, the ability to generalise the results may be a challenge.

Practical implications

The implication of this study is that there is the need to prudently maintain hospital infrastructure and equipment in good working condition as it has a positive effect on patients’ satisfaction of their overall health-care experience.

Originality/value

Most studies have concentrated on patient’s health-care experience. This study extends the knowledge of patient’s health-care experience by determining the mediating role of quality of health-care infrastructure and equipment on the relationship between patient’s satisfaction and core health-care business. There are limited studies of such nature in Ghana. Therefore, this study will provide invaluable empirical data for the health-care sector of a developing African country.

Details

Journal of Facilities Management , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1472-5967

Keywords

Article
Publication date: 30 October 2023

Oluseyi Julius Adebowale and Justus Ngala Agumba

The United Nations has demonstrated a commitment to preserving the ecosystem through its 2030 sustainable development goals agenda. One crucial objective of these goals is to…

Abstract

Purpose

The United Nations has demonstrated a commitment to preserving the ecosystem through its 2030 sustainable development goals agenda. One crucial objective of these goals is to promote a healthy ecosystem and discourage practices that harm it. Building materials production significantly contributes to the emissions of greenhouse gases. This poses a threat to the ecosystem and prompts a growing demand for sustainable building materials (SBMs). The purpose of this study is to investigate SBMs to determine their utilization in construction operations and the potential impact their application could have on construction productivity.

Design/methodology/approach

A systematic review of the existing literature in the field of SBMs was conducted for the study. The search strings used were “sustainable” AND (“building” OR “construction”) AND “materials” AND “productivity”. A total of 146 articles were obtained from the Scopus database and reviewed.

Findings

Bio-based, cementitious and phase change materials were the main categories of SBMs. Materials in these categories have the potential to substantially contribute to sustainability in the construction sector. However, challenges such as availability, cost, expertise, awareness, social acceptance and resistance to innovation must be addressed to promote the increased utilization of SBMs and enhance construction productivity.

Originality/value

Many studies have explored SBMs, but there is a dearth of studies that address productivity in the context of SBMs, which leaves a gap in understanding. This study addresses this gap by drawing on existing studies to determine the potential implications that using SBMs could have on construction productivity.

Details

Journal of Engineering, Design and Technology , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 9 June 2023

Sidney Newton, Phillippa Carnemolla and Simon Darcy

The provision of an accessible and inclusive built environment is both a common regulatory requirement for architects and facilities managers, and a critical issue of equitable…

Abstract

Purpose

The provision of an accessible and inclusive built environment is both a common regulatory requirement for architects and facilities managers, and a critical issue of equitable access for people with disability. Post Occupancy Evaluation (POE) is key to ensuring appropriate building accessibility is provided and maintained. Improved Building Information Modelling (BIM) integration with Facilities Management (FM) will enable more effective POE over time. This study aims to define and demonstrate the practicability and utility of a particular configuration of emerging BIM and related digital technologies, applied in the field.

Design/methodology/approach

A field study approach is applied to investigate the practicability and utility of the technology configuration and POE procedures. A proposed technology configuration is applied to evaluate 21 accessible bathrooms across three university buildings in Sydney, Australia. First, a checklist of technical functionality for a POE of accessible bathrooms particular to the field study FM context is established. The checklist is based on a review of recent literature, relevant standards, best practice guidelines, expert opinions, and the organisational requirements. Then, a technical and procedural approach to POE and BIM integration with FM is defined and applied in the field. Finally, a quantitative analysis of the results is presented and discussed relative to both the particular and general FM contexts.

Findings

The use of low-cost BIM and related technologies can usefully be applied in the field to promote a more progressive integration of BIM with FM and provide enhanced baseline models for ongoing POE. A rudimentary risk assessment of key accessible bathroom features (in the context of this field study) identified that the Toilet: toilet rolls location is unsatisfactory across all bathrooms surveyed and represents an immediate and high-risk failing. Other high-risk issues highlighted in this study included: Approach: access; Entrance: door fittings and security; and Layout: hazards.

Practical implications

This study offers a blue-print for building practitioners to adopt and progressively integrate low-cost BIM and related technologies with extant FM systems. The study also promotes an improved approach to effective POE practice in general, and to the assessment of accessible bathrooms in particular.

Originality/value

Recent reviews highlight key barriers to BIM integration with FM and significant limitations to current POE practice. Proposals for BIM integration with FM tend to focus on the comprehensive use of BIM. This study demonstrates the practicability and utility of a more progressive approach to BIM adoption and integration with FM in general. The study is also novel in that it shows how low-cost BIM and related technologies can be used as a baseline reference for ongoing POE. Building practitioners can adopt and adapt the technology configuration and approach to support a range of POE applications. This field study has identified immediate and high-risk potential failings of the accessible bathrooms provided on one university campus in Sydney, Australia.

Details

Smart and Sustainable Built Environment, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2046-6099

Keywords

Article
Publication date: 21 February 2024

Nehal Elshaboury, Tarek Zayed and Eslam Mohammed Abdelkader

Water pipes degrade over time for a variety of pipe-related, soil-related, operational, and environmental factors. Hence, municipalities are necessitated to implement effective…

Abstract

Purpose

Water pipes degrade over time for a variety of pipe-related, soil-related, operational, and environmental factors. Hence, municipalities are necessitated to implement effective maintenance and rehabilitation strategies for water pipes based on reliable deterioration models and cost-effective inspection programs. In the light of foregoing, the paramount objective of this research study is to develop condition assessment and deterioration prediction models for saltwater pipes in Hong Kong.

Design/methodology/approach

As a perquisite to the development of condition assessment models, spherical fuzzy analytic hierarchy process (SFAHP) is harnessed to analyze the relative importance weights of deterioration factors. Afterward, the relative importance weights of deterioration factors coupled with their effective values are leveraged using the measurement of alternatives and ranking according to the compromise solution (MARCOS) algorithm to analyze the performance condition of water pipes. A condition rating system is then designed counting on the generalized entropy-based probabilistic fuzzy C means (GEPFCM) algorithm. A set of fourth order multiple regression functions are constructed to capture the degradation trends in condition of pipelines overtime covering their disparate characteristics.

Findings

Analytical results demonstrated that the top five influential deterioration factors comprise age, material, traffic, soil corrosivity and material. In addition, it was derived that developed deterioration models accomplished correlation coefficient, mean absolute error and root mean squared error of 0.8, 1.33 and 1.39, respectively.

Originality/value

It can be argued that generated deterioration models can assist municipalities in formulating accurate and cost-effective maintenance, repair and rehabilitation programs.

Details

Engineering, Construction and Architectural Management, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0969-9988

Keywords

Article
Publication date: 9 December 2022

Marcus Vinicius Rosário da Silva, Marcelo Jasmim Meiriño, Julio Vieira Neto Vieira Neto and Sheila Walbe Ornstein

An interaction between emerging technologies (ETs) for facility management (FM) activities and stakeholder skills is necessary to promote the optimization of FM performance…

Abstract

Purpose

An interaction between emerging technologies (ETs) for facility management (FM) activities and stakeholder skills is necessary to promote the optimization of FM performance. Previous studies do not show strategies for the selection of ETs in FM considering the technological competencies of stakeholders. Thus, this study analyzes the interactions between ETs and FM from the perceptions of Brazilian professionals, identifying the most appropriate and effective technological solutions, based on a broad literature review.

Design/methodology/approach

The steps of the methodology are as follows: systematic literature review (SLR); detailing the ETs for FM; online questionnaire based on SLR findings; sample of Brazilian FM professionals; statistical treatment; and discussion.

Findings

Results indicate wireless sensor network, Internet of Thing, building information modeling and Big Data as ETs in FM with greater potential for optimization in the performance of FM activities, from survey respondents.

Research limitations/implications

The scope of possible findings may have been biased, considering the small number of research participants and current transformations resulting from the COVID-19 pandemic (e.g. changes to standard operating procedures).

Practical implications

The results ensure greater security to facility managers in the effective implementation of ETs in FM activities.

Originality/value

The research explores the published studies and the consultation with Brazilian FM professionals in the selection of ETs.

Details

Journal of Facilities Management , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1472-5967

Keywords

Article
Publication date: 28 December 2023

Cláudia Rafaela Saraiva de Melo Simões Nascimento, Adiel Teixeira de Almeida-Filho and Rachel Perez Palha

This paper proposes selecting a construction project portfolio in the context of a public institution, which makes it possible to assess quantitative and qualitative criteria…

Abstract

Purpose

This paper proposes selecting a construction project portfolio in the context of a public institution, which makes it possible to assess quantitative and qualitative criteria, thereby meeting the needs of the institution and the existing constraints.

Design/methodology/approach

The research design follows a framework using technique for order preference by similarity to ideal solution (TOPSIS) associated with integer linear programming.

Findings

The method involves a flow of assessments allowing criteria and weights to be elicited where outcomes are based on the experts' intra-criteria assessment of alternatives and decision-makers' inter-criteria assessment. This is of utmost interest to public organizations, where selections must result in benefits and lower costs, integrating the experts' technical and management perspectives.

Social implications

Public institutions are characterized by having limited financial and personnel resources for project development despite having a high demand for requests not associated with profits, making it essential to have a framework that enables using multiple criteria to better evaluate the benefits related to these decisions.

Originality/value

The main contributions of this article are: (1) the proposition of a framework for selecting construction project portfolios considering the organization's strategic needs; (2) identifying quantitative and qualitative assessment criteria for project selection; (3) integrating TOPSIS with an optimization process for selecting the construction project portfolios and (4) providing a structured decision process for selecting the portfolio that best represents the interests of the institution within its limited resources and personnel.

Details

Engineering, Construction and Architectural Management, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0969-9988

Keywords

Article
Publication date: 1 August 2023

M. Mary Victoria Florence and E. Priyadarshini

This study aims to propose the use of time series autoregressive integrated moving average (ARIMA) models to predict gas path performance in aero engines. The gas path is a…

82

Abstract

Purpose

This study aims to propose the use of time series autoregressive integrated moving average (ARIMA) models to predict gas path performance in aero engines. The gas path is a critical component of an aero engine and its performance is essential for safe and efficient operation of the engine.

Design/methodology/approach

The study analyzes a data set of gas path performance parameters obtained from a fleet of aero engines. The data is preprocessed and then fitted to ARIMA models to predict the future values of the gas path performance parameters. The performance of the ARIMA models is evaluated using various statistical metrics such as mean absolute error, mean squared error and root mean squared error. The results show that the ARIMA models can accurately predict the gas path performance parameters in aero engines.

Findings

The proposed methodology can be used for real-time monitoring and controlling the gas path performance parameters in aero engines, which can improve the safety and efficiency of the engines. Both the Box-Ljung test and the residual analysis were used to demonstrate that the models for both time series were adequate.

Research limitations/implications

To determine whether or not the two series were stationary, the Augmented Dickey–Fuller unit root test was used in this study. The first-order ARIMA models were selected based on the observed autocorrelation function and partial autocorrelation function.

Originality/value

Further, the authors find that the trend of predicted values and original values are similar and the error between them is small.

Details

Aircraft Engineering and Aerospace Technology, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1748-8842

Keywords

Article
Publication date: 6 October 2023

Hawa Ahmad, Suhaiza Ismail and Zamzulaila Zakaria

Drawing on institutional work (Lawrence and Suddaby, 2006; Lawrence et al., 2011), this study aims to explore how the concept of value for money (VFM) is understood in terms of…

Abstract

Purpose

Drawing on institutional work (Lawrence and Suddaby, 2006; Lawrence et al., 2011), this study aims to explore how the concept of value for money (VFM) is understood in terms of the private finance initiative (PFI) implementation in Malaysia.

Design/methodology/approach

In-depth interviews with 25 actors involved in the implementation of PFI projects at two public universities in Malaysia were conducted. The interviews focused on the ways in which participants in the projects make sense of VFM in their ongoing involvement with the projects. In addition, a review of publicly available documents was conducted to understand the ways in which the notion of VFM is reflected in the policies and procedures of the government. Data from the interviews and documents were analysed using thematic analysis.

Findings

It is found that the advocacy work of macro-level actors, as well as micro-level actors, has promoted PFI implementation to achieve VFM. However, to the micro-level actors, VFM is just a concept that carries different interpretations, depending on how PFI fits their everyday functional discourses. In addition, direct negotiation and lack of commercial appreciation are disruptive not only to the achievement of VFM but also to the public sector reform agenda of the country.

Originality/value

The present study contributes to the discourses on the concept of VFM that is assumed to be inherent in PFI. The findings are based on micro- and macro-level actors and cover both advocacy and disruption of VFM achievement.

Details

Journal of Accounting & Organizational Change, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1832-5912

Keywords

Article
Publication date: 22 August 2023

Xian Yun Tan, Norhayati Mahyuddin, Syahrul Nizam Kamaruzzaman, Norhayati Mat Wajid and Abdul Murad Zainal Abidin

Commercial buildings, which include office buildings, are one of the three major energy-consuming sectors, alongside industrial and transportation sectors. The vast increase in…

Abstract

Purpose

Commercial buildings, which include office buildings, are one of the three major energy-consuming sectors, alongside industrial and transportation sectors. The vast increase in the number of buildings is a positive sign of the rapid development of Malaysia. However, most Malaysian government office buildings tend to consume energy inefficiently due to lack of energy optimization. Most of the previous studies focused on the performance of green buildings in fulfilling the green development guidelines. As such, it is essential to study the energy performance of existing government office buildings that were constructed before most energy-efficient standards were implemented to mitigate energy wastage due to the lack of energy optimization. This study aims to analyse the energy performance of existing non-green Malaysian government office buildings and the factors that influence building energy consumption, as well as to evaluate the efficacy of the existing energy conservation measures.

Design/methodology/approach

This study was conducted by a literature review and case study. The chosen buildings are six government office building blocks located in Kuala Lumpur, the capital city of Malaysia. In this study, a literature review has been conducted on the common factors affecting energy consumption in office buildings. The energy consumption data of the buildings were collected to calculate the building energy intensity (BEI). The BEI was compared to the MS1525:2019 and GBI benchmarks to evaluate energy performance. SketchUp software was utilized to illustrate the solar radiation and sun path diagram of the case study buildings. Finally, recommendations were derived for retrofit strategies based on non-design factors and passive design factors.

Findings

In typical government office buildings, the air-conditioning system consumed the most energy at 65.5%, followed by lighting system at 22.6%, and the remaining 11.9% was contributed by office appliances. The energy performance of the case study buildings is considered as satisfactory as the BEI did not exceed the MS1525:2019 benchmark of 200 kWh/m2/year. The E Block recorded the highest BEI of 183.12 kWh/m2/year in 2020 due to its north-east orientation which is exposed to the most solar radiation. Besides, E Block consists of rooms that can accommodate large number of occupants. As such, non-design factors which include higher occupancy rate and higher cooling demand due to high outdoor temperature leads to higher energy consumption. By considering passive design features such as building orientation and building envelope thermal properties, energy consumption can be reduced significantly.

Originality/value

This study provided a comprehensive insight into the energy performance of Malaysian government office buildings, which were constructed before the energy-efficient standards being introduced. By calculating the BEI of six government office buildings, it is found that the energy performance of the case study buildings fulfils the MS1525 benchmark, and that all their BEIs are below 200 kWh/m2/year. Malaysia's hot and humid climate significantly affects a building's cooling load, and it is found the air-conditioning system is the major energy consumer of Malaysian government office buildings. This study discusses the efficacy of the energy-saving measures implemented in the case study buildings to optimize energy consumption. Recommendations were derived based on the non-design factors and passive design factors that affected the energy consumption of the case study building. It is envisioned that this study can provide practical strategies for retrofit interventions to reduce energy consumption in Malaysian office buildings as well as for office buildings that are in a similar climate.

Details

Open House International, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0168-2601

Keywords

Article
Publication date: 30 March 2023

Flora Bougiatioti, Eleni Alexandrou and Miltiadis Katsaros

Residential buildings in Greece constitute an important portion of the existing building stock. Furthermore, most of these buildings were built prior to the first Thermal…

Abstract

Purpose

Residential buildings in Greece constitute an important portion of the existing building stock. Furthermore, most of these buildings were built prior to the first Thermal Insulation Code of 1981. The article focuses on existing, typical residences built after 1920, which are found mostly in suburban areas and settlements all around Greece. The purpose of the research is to evaluate the effect of simple bioclimatic interventions focused on the improvement of their diurnal, inter-seasonal and annual thermal performance.

Design/methodology/approach

The applied strategies include application of thermal insulation in the building shell and openings, passive solar systems for the heating period and shading and natural ventilation for the summer period. The effect of the strategies is analysed with the use of building energy analysis. The simulation method was selected because it provides the possibility of parametric analysis and comparisons for different proposals in different orientations.

Findings

The results show that the increased thermal mass of the construction is the most decisive parameter of the thermal behaviour throughout the year.

Research limitations/implications

The typical residences under investigation are often found in urban and/or suburban surroundings. These mostly refer to free-standing buildings situated, which, in many cases, do not have the disadvantages and limitations that the geometrical characteristics of densely built urban locations impose on incident solar radiation (e.g. overshadowing during the winter) and air circulation (e.g. reduce natural ventilation during the summer). Nevertheless, even in these cases, the surrounding built environment may also have relevant negative effects, which were not taken under consideration and could be included in further, future research that will include the effect of various orientations, as well as of neighbouring buildings.

Practical implications

Existing residences built prior to the first Thermal Insulation Code (1981) form an important part of the building stock. Consequently their energy upgrade could contribute to significant conventional energy savings for heating and cooling, along with the inter-seasonal improvement of interior thermal comfort conditions.

Social implications

The proposed interventions can improve thermal comfort conditions and lead to a reduction of energy consumption for heating and cooling, which is an important step against energy poverty and the on-going energy crisis.

Originality/value

The proposed interventions only involve the building envelope and are simple with relatively low cost.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

1 – 10 of 252