Search results

1 – 2 of 2
Article
Publication date: 24 December 2020

Hongya Niu, Zhaoce Liu, Wei Hu, Wenjing Cheng, Mengren Li, Fanli Xue, Zhenxiao Wu, Jinxi Wang and Jingsen Fan

Severe airborne particulate pollution frequently occurs over the North China Plain (NCP) region in recent years. To better understand the characteristics of carbonaceous…

Abstract

Purpose

Severe airborne particulate pollution frequently occurs over the North China Plain (NCP) region in recent years. To better understand the characteristics of carbonaceous components in particulate matter (PM) over the NCP region.

Design/methodology/approach

PM samples were collected at a typical area affected by industrial emissions in Handan, in January 2016. The concentrations of organic carbon (OC) and elemental carbon (EC) in PM of different size ranges (i.e. PM2.5, PM10 and TSP) were measured. The concentrations of secondary organic carbon (SOC) were estimated by the EC tracer method.

Findings

The results show that the concentration of OC ranged from 14.9 μg m−3 to 108.4 μg m−3, and that of EC ranged from 4.0 μg m−3 to 19.4μg m−3, when PM2.5 changed from 58.0μg m−3 to 251.1μg m−3 during haze days, and the carbonaceous aerosols most distributed in PM2.5 rather than large fraction. The concentrations of OC and EC PM2.5 correlated better (r = 0.7) than in PM2.5−10 and PM>10, implying that primary emissions were dominant sources of OC and EC in PM2.5. The mean ratios of OC/EC in PM2.5, PM2.5–10 and PM>10 were 4.4 ± 2.1, 3.6 ± 0.9 and 1.9 ± 0.7, respectively. Based on estimation, SOC accounted for 16.3%, 22.0% and 9.1% in PM2.5, PM2.5–10 and PM>10 respectively.

Originality/value

The ratio of SOC/OC (48.2%) in PM2.5 was higher in Handan than those (28%–32%) in other megacities, e.g. Beijing, Tianjin and Shijiazhuang in the NCP, suggesting that the formation of SOC contributed significantly to OC. The mean mass absorption efficiencies of EC (MACEC) in PM10 and TSP were 3.4 m2 g−1 (1.9–6.6 m2 g−1) and 2.9 m2 g−1 (1.6–5.6 m2 g−1), respectively, both of which had similar variation patterns to those of OC/EC and SOC/OC.

Details

World Journal of Engineering, vol. 18 no. 2
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 7 September 2012

Michael V. Gangone, Matthew J. Whelan, Kerop D. Janoyan and Levon Minnetyan

The purpose of this paper is to further validate a wireless sensor system developed at Clarkson University for structural monitoring of highway bridges. The particular bridge…

Abstract

Purpose

The purpose of this paper is to further validate a wireless sensor system developed at Clarkson University for structural monitoring of highway bridges. The particular bridge monitored employs a fiber reinforced polymer (FRP) panel system which is fairly innovative in the field of civil engineering design. The superstructure was monitored on two separate occasions to determine a change in structural response and see how the structural system performs over time.

Design/methodology/approach

A series of wireless sensor units was deployed at various locations of the steel superstructure, to measure both the modal response from acceleration measurements as well as quasi‐static and dynamic strain response. Ambient and forced loading conditions were applied to measure the response. Data results were compared over two separate periods approximately nine months apart.

Findings

The first eight mode shapes were produced from output‐only system identification providing natural frequencies ranging from approximately 6 to 42 Hz. The strain response was monitored over two different testing periods to measure various performance characteristics. Neutral axis, distribution factor, impact factor and end fixity were determined. Results appeared to be different over the two testing periods. They indicate that the load rating of the superstructure decreased over the nine month period, possibly due to deterioration of the materials or composite action.

Research limitations/implications

The results from the two testing periods indicate that further testing needs to be completed to validate the change in response. It is difficult to say with certainty that the significant change in response is due to bridge deterioration and not other factors such as temperature effects on load rating. The sensor system, however, proved to provide high quality data and responses indicating its successful deployment for load testing and monitoring of highway infrastructure.

Originality/value

The paper provides a depiction of the change in structural behavior of a bridge superstructure using a wireless sensor system. The wireless system provided high‐rate data transmission in real time. Load testing at two different points in time, eight months apart, showed a significant change in bridge behavior. The paper provides a practical and actual physical load test and rating during these two periods for quantifiable change in response. It is shown that the wireless system is capable of infrastructure monitoring and that possible deterioration is expected with this particular bridge design. Additionally, the load testing occurred during different seasons, which could create cause for temperature effects in load rating. This can provide a basis for future performance monitoring techniques and structural health monitoring.

1 – 2 of 2