Search results

1 – 10 of 179
Article
Publication date: 11 January 2023

Nor Salwani Hashim and Fatimah De’nan

It is generally known that the perforated section such as the castellated section is good to sustain distributed loads but inadequate to sustain highly concentrated loads…

Abstract

Purpose

It is generally known that the perforated section such as the castellated section is good to sustain distributed loads but inadequate to sustain highly concentrated loads. Therefore, it is possible to design the opening in a different arrangement of web opening to achieve section efficiency, thus improving the strength and torsional behaviour of the section with web opening. This study aims to focus on the finite element analysis of I-beam with and without openings in steel section dominated to lateral-torsional buckling behaviour.

Design/methodology/approach

In this work, the analysis of different sizes, shapes and arrangements of web opening is performed by using LUSAS application to conduct numerical analysis on lateral-torsional buckling behaviour. This involves three diameter sizes of web opening, five types of opening shapes and two criteria of the model.

Findings

The section with c-hexagon web opening was placed about 200-mm centre to centre and 100-mm edge distance, contribute to 7.26% increase of buckling capacity. For the section with 150-mm centre to centre and 50-mm edge distance, the occurrence of local buckling contributes to decrease of lateral buckling section capacity to 19.943 kNm, where pure lateral-torsional buckling mostly occurred because of prevented section. Besides that, the web opening diameter was also analysed. The web crippling was observed because of the increase of opening diameter from 0.67 to 0.80 D.

Originality/value

This contributes to a decrease in buckling capacity as figured in the contour of the deformed shape. For Model 1, an increase of buckling capacity (31.46%) is observed when the opening diameter are changed from 0.67 to 0.80 D.

Details

World Journal of Engineering, vol. 21 no. 2
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 14 March 2019

Mohammad Zaman Kabir and Mehdi Parvizi

The purpose of this paper is to focus on the influences of residual stresses which were induced during roll-forming sections on lateral-torsional buckling of thin-walled…

Abstract

Purpose

The purpose of this paper is to focus on the influences of residual stresses which were induced during roll-forming sections on lateral-torsional buckling of thin-walled cold-formed steel channel and built-up I-sections beams. Built-up I section is made up of two back-to-back cold-formed channel beams. In this direction, at the primary stage, the roll-forming process of a channel section was simulated in ABAQUS environment and the accuracy of the result was verified with those existing experiments. Residual stresses and strains in both longitudinal and circumferential transverse directions were extracted and considered in the lateral-torsional buckling analysis under uniform end moments. The contribution of the current research is devoted to the numerical simulation of the rolling process in ABAQUS software enabling to restore the remaining stresses and strains for the buckling analysis in the identical software. The results showed that the residual stresses decrease considerably the lateral-torsional buckling strength as they have a major impact on short-span beams for channel sections and larger span for built-up I sections. The obtained moment capacity from the buckling analysis was compared to the predictions by American Iron and Steel Institute design code and it is found to be conservative.

Design/methodology/approach

This paper has explained a numerical study on the roll-forming process of a channel section and member moment capacities related to the lateral-torsional buckling of the rolled form channel and built-up I-sections beams under uniform bending about its major axis. It has also investigated the effects of residual stresses and strains on the behaviour of this buckling mode.

Findings

The residuals decrease the moment capacities of the channel beams and have major effect on shorter spans and also increase the local buckling strength of compression flange. But the residuals have major effect on larger spans for built-up I sections. It could be seen that the ratio of moment (with residuals and without residuals) for singly symmetric sections is more pronounced than doubly symmetric sections. So it is recommended to use doubly symmetric section of cold-formed section beams.

Originality/value

The incorporation of residual stresses and strains in the process of numerical simulation of rolled forming of cold-formed steel sections under end moments is the main contribution of the current work. The effect of residual stresses and strains on the lateral-torsional buckling is, for the first time, addressed in the paper.

Details

International Journal of Structural Integrity, vol. 10 no. 2
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 20 May 2022

Fatimah De´nan, Nor Salwani Hashim and Amarpreet Kaur Mahinder Singh

Due to the enormous increase in economic development, structural steel material gives an advantage for the construction of stadiums, factories, bridges and cities building design…

Abstract

Purpose

Due to the enormous increase in economic development, structural steel material gives an advantage for the construction of stadiums, factories, bridges and cities building design. The purpose of this study is to investigate the behaviour of bending, buckling and torsion for I-beam steel section with and without web opening using non-linear finite element analysis.

Design/methodology/approach

The control model was simulated via LUSAS software with the four main parameters which included opening size, layout, shape and orientation. The analysis used a constant beam span which is 3.5 m while the edge distance from the centre of the opening to the edge of the beam is kept constant at 250 mm at each end.

Findings

The analysis results show that the optimum opening size obtained is 0.65 D while optimum layout of opening is Layout 1 with nine web openings. Under bending behaviour, steel section with octagon shapes of web opening shows the highest yield load, yield moment and thus highest structural efficiency as compared to other shapes of openings. Besides, square shape of web opening has the highest structural efficiency under buckling behaviour. The lower buckling load and buckling moment contribute to the higher structural efficiency.

Originality/value

Further, the square web opening with counter clockwise has the highest structural efficiency under torsion behaviour.

Details

World Journal of Engineering, vol. 20 no. 6
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 28 April 2023

Fatimah De’nan, Nor Salwani Hashim and Ngo Siew Ting

Recently, this steel section has found increasing popularity in residential, industrial and commercial buildings with their high load-carrying capacity due to the nature of high…

Abstract

Purpose

Recently, this steel section has found increasing popularity in residential, industrial and commercial buildings with their high load-carrying capacity due to the nature of high strength to weight ratio properties. However, the rise on the price of steel section should be more emphasized; therefore, the optimization in steel section design is needed to overcome the issue of material cost. As such, tapered steel sections save on material use, while the introduction of web openings allows the placement of mechanical and electrical services, plumbing and also aesthetic design considerations.

Design/methodology/approach

The purpose of this study is to investigate the lateral torsional buckling behavior of a tapered steel section with an ellipse-shaped opening by analyzing its structural parameters. To achieve this, the finite element analysis (FEA) of the section is modeled using LUSAS software, which allows for a detailed analysis of the section's behavior under varying loads and conditions. It involves the variation in web opening size, opening layout, opening rotation angle and the tapering ratio. Eigenvalue buckling analysis is adopted to know the parametric effects of each 108 model. The size of opening varies from 0.2 to 0.5 d of the total depth where the opening located. There are three type of layouts applied in this study, which are the layouts A, B and C. There are three types of rotation angles for the ellipse-shaped opening, including the non-rotated vertical opening and two additional types formed by rotating the opening 45 degrees clockwise and counterclockwise around the center-point of the ellipse. A fixed-free boundary condition was applied, resulting in a simulation of a cantilever beam. The models are fixed at one end with a larger depth, and free at the other end with a smaller depth. Loading condition is an application of 10 kN/m uniform distributed load in the direction of gravity along the mid-span of the top flange.

Findings

It is observed that the model 82 with Layout A, tapering ratio 0.3, opening size 0.5 d and opening rotated in 45 degree anti-clockwise direction results in the highest structural efficiency among the 108 models. Therefore, the buckling moment of model 82 is 1,013.08 kNm with structural efficiency of 481.26, which shows an increase of 3.17% compared to the controlled model.

Originality/value

The FEA results shows a significant increase in ductility and stiffness of the tapered steel section with elipse shape opening and consequently changes in the behaviour of yield point.

Details

World Journal of Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 23 September 2020

Fatimah De'nan, Nor Salwani Hashim and Lim Cheng Kuan

Tapered section can resist maximum stress at a single location while the stresses are considerably lower at the rest of the member; therefore, it could have higher structural…

Abstract

Purpose

Tapered section can resist maximum stress at a single location while the stresses are considerably lower at the rest of the member; therefore, it could have higher structural efficiency compared to conventional section. It could also satisfy functional requirements while reducing weight and cost in many fields of civil construction. Perforation in the steel section also eases the integration of Mechanical and Electrical (M&E) services such as ventilation pipes and electrical cables within the structural depths of the beam. In this analysis, the structural efficiency of tapered steel section with perforation under lateral-torsional buckling behaviour is investigated.

Design/methodology/approach

A total of 81 models are analysed using LUSAS software and five variables are investigated which involved perforation sizes, perforation shapes, perforation layout, tapering ratio and flange and Web thickness. Buckling moment is obtained from the analysis results in LUSAS software, while self-weight and structural efficiency are manually calculated.

Findings

Perforation size of 0.75 D has the highest structural efficiency, although it can withstand a smaller buckling load. This is due to its lower self-weight compared to other perforation sizes. The square perforation shape also has the highest structural efficiency compared to circular perforation and diamond perforation. An increment of percentage in structural efficiency of the square perforation shape with 0.75 D is the highest at 3.07%. The circular perforation shape with 0.75 D (Open-Open-Open perforation layout) has the highest increment of percentage in structural efficiency which is 2.37%. The tapering ratio of 0.3 is the most efficient and an increment of percentage in structural efficiency is 114.36%. The flange thickness of 0.02 m and Web thickness of 0.015 m has the highest structural efficiency at 45.756 and 29.171, respectively.

Originality/value

In conclusion, a section should be able to resist the large buckling moment and has a lower self-weight to achieve high structural efficiency.

Details

World Journal of Engineering, vol. 17 no. 6
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 12 December 2016

Flávio Arrais, Nuno Lopes and Paulo Vila Real

Steel beams composed of cold-formed sections are common in buildings because of their lightness and ability to support large spans. However, the instability phenomena associated…

Abstract

Purpose

Steel beams composed of cold-formed sections are common in buildings because of their lightness and ability to support large spans. However, the instability phenomena associated to these members are not completely understood in fire situation. Thus, the purpose of this study is to analyse the behaviour of beams composed of cold-formed lipped channel sections at elevated temperatures.

Design/methodology/approach

A numerical analysis is made, applying the finite element program SAFIR, on the behaviour of simply supported cold formed steel beams at elevated temperatures. A parametric study, considering several cross-sections with different slenderness’s values, steel grades and bending diagrams, is presented. The obtained numerical results are compared with the design bending resistances determined from Eurocode 3 Part 1-2 and its French National Annex (FN Annex).

Findings

The current design expressions revealed to be too conservative when compared with the obtained numerical results. It was possible to observe that the FN Annex is less conservative than the Annex E, the first having a better agreement with the numerical results.

Originality/value

Following the previous comparisons, new fire design formulae are tested. This new methodology, which introduces minimum changes in the existing formulae, provides safety and accuracy at the same time when compared to the numerical results, considering the occurrence of local, distortional and lateral torsional buckling phenomena in these members at elevated temperatures.

Details

Journal of Structural Fire Engineering, vol. 7 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 10 July 2023

Fatimah De’nan, Chong Shek Wai and Nor Salwani Hashim

Various designs of corrugated webs include trapezoidal, sinusoidal, triangular and rectangular profiles. The increasing use of curved plates has prompted the creation of…

Abstract

Purpose

Various designs of corrugated webs include trapezoidal, sinusoidal, triangular and rectangular profiles. The increasing use of curved plates has prompted the creation of I-sections made of steel with a corrugated web design. This study aims to examine the effectiveness of an I-beam steel section that features a perforated-triangular web profile.

Design/methodology/approach

In the current study, finite element analysis was conducted on corrugated-perforated steel I-sections using ANSYS software. The study focused on inspecting the design of the perforations, including their shape (circle, square, hexagon, diamond and octagon), size of perforations (80 mm, 100 mm and 120 mm) and layout (the position of web perforation), as well as examining the geometric properties of the section in term of bending, lateral torsional buckling, torsion and shear behavior.

Findings

The study revealed that perforations with diamond, circle and hexagon shapes exhibit good performance, whereas the square shape performs poorly. Moreover, the steel section’s performance decreases with an increase in perforation size, regardless of loading conditions. In addition, the shape of the web perforations can also influence its stress distribution. For example, diamond-shaped perforations have been found to perform better than square-shaped perforations in terms of stress distribution and overall performance. This was because of their ability to distribute stress more evenly and provide greater support to the surrounding material. The diagonal alignment of the diamond shape aligns with principal stress directions, allowing for efficient load transfer and reduced stress concentrations. Additionally, diamond-shaped perforations offer a larger effective area, better shear transfer and improved strain redistribution, resulting in enhanced structural integrity and increased load-carrying capacity.

Originality/value

Hence, the presence of lateral-torsional buckling and torsional loading conditions significantly impacts the performance of corrugated-perforated steel I-sections.

Details

World Journal of Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1708-5284

Keywords

Article
Publication date: 28 June 2021

Flávio Arrais, Nuno Lopes and Paulo Vila Real

Sigma cross-section profiles are often chosen for their lightness and ability to support large spans, offering a favourable bending resistance. However, they are more susceptible…

Abstract

Purpose

Sigma cross-section profiles are often chosen for their lightness and ability to support large spans, offering a favourable bending resistance. However, they are more susceptible to local, distortional and lateral-torsional buckling, as possible failure modes when compared to common I-sections and hollow cross-sections. However, the instability phenomena associated to these members are not completely understood in fire situation. Therefore, the purpose of this study is to analyse the behaviour of beams composed of cold-formed sigma sections at elevated temperatures.

Design/methodology/approach

This study presents a numerical analysis, using advanced methods by applying the finite element software SAFIR. A numerical analysis of the behaviour of simply supported cold-formed sigma beams in the case of fire is presented considering different cross-section slenderness values, elevated temperatures, steel grades and bending moment diagrams. Comparisons are made between the obtained numerically ultimate bending capacities and the design bending resistances from Eurocode 3 Part 1–2 rules and its respective French National Annex (FN Annex).

Findings

The current design expressions revealed to be over conservative when compared with the obtained numerical results. It was possible to observe that the FN Annex is less conservative than the general prescriptions, the first having a better agreement with the numerical results.

Originality/value

Following the previous comparisons, new fire design formulae are analysed. This new methodology, which introduces minimum changes in the existing formulae, provides at the same time safety and accuracy when compared to the numerical results, considering the occurrence of local, distortional and lateral-torsional buckling phenomena in these members at elevated temperatures.

Details

Journal of Structural Fire Engineering, vol. 12 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 16 August 2019

Carlos Couto, Élio Maia, Paulo Vila Real and Nuno Lopes

The purpose of this paper is to assess whether the adaptation to fire of current proposals/design methodologies at normal temperature is capable of producing accurate predictions…

Abstract

Purpose

The purpose of this paper is to assess whether the adaptation to fire of current proposals/design methodologies at normal temperature is capable of producing accurate predictions of resistance for the out-of-plane stability of tapered beams.

Design/methodology/approach

The adaptation of these methodologies to fire has been done by accounting for the reduction in steel material properties with the temperature. Results were then compared to FEM calculations by performing GMNIA analyses to determine the ultimate strength of the numerical models and to ascertain the validity and accuracy of the adapted methodologies.

Findings

Although all methodologies produce safe results at normal temperatures, only the general method is recommended for the safety verification at elevated temperatures, although the data points were overly conservative. This investigation demonstrates the need of proper and accurate design methods for tapered beams at elevated temperatures, which should be the subject of future developments.

Research limitations/implications

The research in this paper is limited to the adaptation of existing room temperature design methods to fire. Therefore, possible assumptions made during the conception of the initial formulae, which may be valid exclusively for 20ºC, may have been disregarded.

Originality/value

For the time being, design methodologies for the safety check of tapered beams for the case of fire are inexistent. This paper investigates the adaptation of existing room temperature design to the fire situation by providing insights on their accuracy level, as well as on how to proceed. Finally, a safe design methodology for tapered beams in case of fire is provided until improved design methods are developed.

Details

Journal of Structural Fire Engineering, vol. 10 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 12 December 2016

Luis Laím and João Paulo C. Rodrigues

This paper is mainly aimed at the structural performance of compound cold-formed galvanised steel beams under fire conditions based on the results of a large programme of…

Abstract

Purpose

This paper is mainly aimed at the structural performance of compound cold-formed galvanised steel beams under fire conditions based on the results of a large programme of experimental tests and numerical simulations. The main objective of this research was to assess the critical temperature and time of the studied beams. Other important goals of this research work were to investigate the influence of the cross-sections (C, lipped-I, R and 2R beams) and, above all, of the axial restraint (0, 0.45, 3, 7.5, 15, 30, ∞ kN/mm) to the thermal elongation of the beam and the rotational restraint at beam supports (0, 15, 80, 150, 300, 1,200 and ∞ kN.m/rad) on the fire resistance of this kind of beams.

Design/methodology/approach

This paper still provides details of the simulation methodology for achieving numerical stability and faithful representation of detailed structural behaviour and compares the simulation and experimental results, including beam failure modes, measured beam axial forces and beam mid-span deflections.

Findings

Good agreement between Abaqus simulations and experimental observations confirms that the finite element models developed with the Abaqus/standard solver are suitable for predicting the structural fire behaviour of restrained cold-formed steel beams.

Originality/value

The results showed above all that the effect of the stiffness of the surrounding structure seems to decrease with the increasing slenderness of the beams.

Details

Journal of Structural Fire Engineering, vol. 7 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords