Search results

1 – 10 of over 4000
Article
Publication date: 10 February 2020

Dongping Zhao, Gangfeng Wang, Jizhuang Hui, Wei Hou and Richard David Evans

The assembly quality of complex products is pivotal to their lifecycle performance. Assembly precision analysis (APA) is an effective method used to check the feasibility and…

Abstract

Purpose

The assembly quality of complex products is pivotal to their lifecycle performance. Assembly precision analysis (APA) is an effective method used to check the feasibility and quality of assembly. However, there is still a need for a systematic approach to be developed for APA of kinematic mechanisms. To achieve more accurate analysis of kinematic assembly, this paper aims to propose a precision analysis method based on equivalence of the deviation source.

Design/methodology/approach

A unified deviation vector representation model is adopted by considering dimension deviation, geometric deviation, joint clearance and assembly deformation. Then, vector loops and vector equations are constructed, according to joint type and deviation propagation path. A combined method, using deviation accumulation and sensitivity modeling, is applied to solve the kinematic APA of complex products.

Findings

When using the presented method, geometric form deviation, joint clearance and assembly deformation are considered selectively during tolerance modeling. In particular, the proposed virtual link model and its orientation angle are developed to determine joint deviation. Finally, vector loops and vector equations are modeled to express deviation accumulation.

Originality/value

The proposed method provides a new means for the APA of complex products, considering joint clearance and assembly deformation while improving the accuracy of APA, as much as possible.

Details

Assembly Automation, vol. 40 no. 3
Type: Research Article
ISSN: 0144-5154

Keywords

Article
Publication date: 29 April 2019

Guozhi Li, Fuhai Zhang, Yili Fu and Shuguo Wang

The purpose of this paper is to propose an error model for serial robot kinematic calibration based on dual quaternions.

Abstract

Purpose

The purpose of this paper is to propose an error model for serial robot kinematic calibration based on dual quaternions.

Design/methodology/approach

The dual quaternions are the combination of dual-number theory and quaternion algebra, which means that they can represent spatial transformation. The dual quaternions can represent the screw displacement in a compact and efficient way, so that they are used for the kinematic analysis of serial robot. The error model proposed in this paper is derived from the forward kinematic equations via using dual quaternion algebra. The full pose measurements are considered to apply the error model to the serial robot by using Leica Geosystems Absolute Tracker (AT960) and tracker machine control (T-MAC) probe.

Findings

Two kinematic-parameter identification algorithms are derived from the proposed error model based on dual quaternions, and they can be used for serial robot calibration. The error model uses Denavit–Hartenberg (DH) notation in the kinematic analysis, so that it gives the intuitive geometrical meaning of the kinematic parameters. The absolute tracker system can measure the position and orientation of the end-effector (EE) simultaneously via using T-MAC.

Originality/value

The error model formulated by dual quaternion algebra contains all the basic geometrical parameters of serial robot during the kinematic calibration process. The vector of dual quaternion error can be used as an indicator to represent the trend of error change of robot’s EE between the nominal value and the actual value. The accuracy of the EE is improved after nearly 20 measurements in the experiment conduct on robot SDA5F. The simulation and experiment verify the effectiveness of the error model and the calibration algorithms.

Details

Industrial Robot: the international journal of robotics research and application, vol. 46 no. 2
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 20 December 2017

Dan Zhao, Yunbo Bi and Yinglin Ke

This paper aims to propose a united kinematic calibration method for a dual-machine system in automatic drilling and riveting. The method takes both absolute and relative pose…

Abstract

Purpose

This paper aims to propose a united kinematic calibration method for a dual-machine system in automatic drilling and riveting. The method takes both absolute and relative pose accuracy into account, which will largely influence the machining accuracy of the dual-machine system and assembly quality.

Design/methodology/approach

A comprehensive kinematic model of the dual-machine system is established by the superposition of sub-models with pose constraints, which involves base frame parameters, kinematic parameters and tool frame parameters. Based on the kinematic model and the actual pose error data measured by a laser tracker, the parameters of coordinated machines are identified by the Levenberg–Marquardt method as a multi-objective nonlinear optimization problem. The identified parameters of the coordinated machines will be used in the control system.

Findings

A new calibration method for the dual-machine system is developed, including a comprehensive kinematic model and an efficient parameter identification method. The experiment results show that with the proposed method, the pose accuracy of the dual-machine system was remarkably improved, especially the relative position and orientation errors.

Practical implications

This method has been used in an aircraft assembly project. The calibrated dual-machine system shows a good performance on system coordination and machining accuracy.

Originality/value

This paper proposes a new method with high accuracy and efficiency for the dual-machine system calibration. The research can be extended to multi-machine and multi-robot fields to improve the system precision.

Article
Publication date: 22 May 2023

Yujie Zhang, Jing Cui, Yang Li and Zhongyi Chu

This paper aims to address the issue of model discontinuity typically encountered in traditional Denavit-Hartenberg (DH) models. To achieve this, we propose the use of a local…

Abstract

Purpose

This paper aims to address the issue of model discontinuity typically encountered in traditional Denavit-Hartenberg (DH) models. To achieve this, we propose the use of a local Product of Exponentials (POE) approach. Additionally, a modified calibration model is presented which takes into account both kinematic errors and high-order joint-dependent kinematic errors. Both kinematic errors and high-order joint-dependent kinematic errors are analyzed to modify the model.

Design/methodology/approach

Robot positioning accuracy is critically important in high-speed and heavy-load manufacturing applications. One essential problem encountered in calibration of series robot is that the traditional methods only consider fitting kinematic errors, while ignoring joint-dependent kinematic errors.

Findings

Laguerre polynomials are chosen to fitting kinematic errors and high-order joint-dependent kinematic errors which can avoid the Runge phenomenon of curve fitting to a great extent. Levenberg–Marquard algorithm, which is insensitive to overparameterization and can effectively deal with redundant parameters, is used to quickly calibrate the modified model. Experiments on an EFFORT ER50 robot are implemented to validate the efficiency of the proposed method; compared with the Chebyshev polynomial calibration methods, the positioning accuracy is improved from 0.2301 to 0.2224 mm.

Originality/value

The results demonstrate the substantial improvement in the absolute positioning accuracy achieved by the proposed calibration methods on an industrial serial robot.

Details

Industrial Robot: the international journal of robotics research and application, vol. 50 no. 5
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 7 December 2018

Hua Liu, Weidong Zhu, Huiyue Dong and Yinglin Ke

This paper aims to propose a calibration model for kinematic parameters identification of serial robot to improve its positioning accuracy, which only requires position…

Abstract

Purpose

This paper aims to propose a calibration model for kinematic parameters identification of serial robot to improve its positioning accuracy, which only requires position measurement of the end-effector.

Design/methodology/approach

The proposed model is established based on local frame representation of the product of exponentials (local POE) formula, which integrates all kinematic errors into the twist coordinates errors; then they are identified with the tool frame’ position deviations simultaneously by an iterative least squares algorithm.

Findings

To verify the effectiveness of the proposed method, extensive simulations and calibration experiments have been conducted on a 4DOF SCARA robot and a 5DOF drilling machine, respectively. The results indicate that the proposed model outperforms the existing model in convergence, accuracy, robustness and efficiency; fewer measurements are needed to gain an acceptable identification result.

Practical implications

This calibration method has been applied to a variable-radius circumferential drilling machine. The machine’s positioning accuracy can be significantly improved from 11.153 initially to 0.301 mm, which is well in the tolerance (±0.5 mm) for fastener hole drilling in aircraft assembly.

Originality/value

An accurate and efficient kinematic calibration model has been proposed, which satisfies the completeness, continuity and minimality requirements. Due to generality, this model can be widely used for serial robot kinematic calibration with any combination of revolute and prismatic joints.

Details

Industrial Robot: An International Journal, vol. 45 no. 5
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 8 September 2021

Yuezong Wang, Jinghui Liu, Mengfei Guo and LiuQIan Wang

A three-dimensional (3D) printing error simulation approach is proposed to analyze the influence of tilted vertical beams on the 3D printing accuracy. The purpose of this study is…

Abstract

Purpose

A three-dimensional (3D) printing error simulation approach is proposed to analyze the influence of tilted vertical beams on the 3D printing accuracy. The purpose of this study is to analyze the influence of such errors on printing accuracy and printing quality for delta-robot 3D printer.

Design/methodology/approach

First, the kinematic model of a delta-robot 3D printer with an ideal geometric structure is proposed by using vector analysis. Then, the normal kinematic model of a nonideal delta-robot 3D robot with tilted vertical beams is derived based on the above ideal kinematic model. Finally, a 3D printing error simulation approach is proposed to analyze the influence of tilted vertical beams on the 3D printing accuracy.

Findings

The results show that tilted vertical beams can indeed cause 3D printing errors and further influence the 3D printing quality of the final products and that the 3D printing errors of tilted vertical beams are related to the rotation angles of the tilted vertical beams. The larger the rotation angles of the tilted vertical beams are, the greater the geometric deformations of the printed structures.

Originality/value

Three vertical beams and six horizontal beams constitute the supporting parts of the frame of a delta-robot 3D printer. In this paper, the orientations of tilted vertical beams are shown to have a significant influence on 3D printing accuracy. However, the effect of tilted vertical beams on 3D printing accuracy is difficult to capture by instruments. To reveal the 3D printing error mechanisms under the condition of tilted vertical beams, the error generation mechanism and the quantitative influence of tilted vertical beams on 3D printing accuracy are studied by simulating the parallel motion mechanism of a delta-robot 3D printer with tilted vertical beams.

Details

Rapid Prototyping Journal, vol. 27 no. 9
Type: Research Article
ISSN: 1355-2546

Keywords

Article
Publication date: 8 April 2021

Wenmin Chu, Xiang Huang and Shuanggao Li

With the improvement of modern aircraft requirements for safety, long life and economy, higher quality aircraft assembly is needed. However, due to the manufacturing and assembly…

Abstract

Purpose

With the improvement of modern aircraft requirements for safety, long life and economy, higher quality aircraft assembly is needed. However, due to the manufacturing and assembly errors of the posture adjustment mechanism (PAM) used in the digital assembly of aircraft large component (ALC), the posture alignment accuracy of ALC is difficult to be guaranteed, and the posture adjustment stress is easy to be generated. Aiming at these problems, this paper aims to propose a calibration method of redundant actuated parallel mechanism (RAPM) for posture adjustment.

Design/methodology/approach

First, the kinematics model of the PAM is established, and the influence of the coupling relationship between the axes of the numerical control locators (NCL) is analyzed. Second, the calibration method based on force closed-loop feedback is used to calibrate each branch chain (BC) of the PAM, and the solution of kinematic parameters is optimized by Random Sample Consensus (RANSAC). Third, the uncertainty of kinematic calibration is analyzed by Monte Carlo method. Finally, a simulated posture adjustment system was built to calibrate the kinematics parameters of PAM, and the posture adjustment experiment was carried out according to the calibration results.

Findings

The experiment results show that the proposed calibration method can significantly improve the posture adjustment accuracy and greatly reduce the posture adjustment stress.

Originality/value

In this paper, a calibration method based on force feedback is proposed to avoid the deformation of NCL and bracket caused by redundant driving during the calibration process, and RANSAC method is used to reduce the influence of large random error on the calibration accuracy.

Details

Industrial Robot: the international journal of robotics research and application, vol. 48 no. 4
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 25 August 2021

Qiang Cao, Jianfeng Li and Mingjie Dong

The purpose of this paper is to evaluate three categories of four-degrees of freedom (4-DOFs) upper limb rehabilitation exoskeleton mechanisms from the perspective of relative…

Abstract

Purpose

The purpose of this paper is to evaluate three categories of four-degrees of freedom (4-DOFs) upper limb rehabilitation exoskeleton mechanisms from the perspective of relative movement offsets between the upper limb and the exoskeleton, so as to provide reference for the selection of exoskeleton mechanism configurations.

Design/methodology/approach

According to the configuration synthesis and optimum principles of 4-DOFs upper limb exoskeleton mechanisms, three categories of exoskeletons compatible with upper limb were proposed. From the perspective of human exoskeleton closed chain, through reasonable decomposition and kinematic characteristics analysis of passive connective joints, the kinematic equations of three categories exoskeletons were established and inverse position solution method were addressed. Subsequently, three indexes, which can represent the relative movement offsets of human–exoskeleton were defined.

Findings

Based on the presented position solution and evaluation indexes, the joint displacements and relative movement offsets of the three exoskeletons during eating movement were compared, on which the kinematic characteristics were investigated. The results indicated that the second category of exoskeleton was more suitable for upper limb rehabilitation than the other two categories.

Originality/value

This paper has a certain reference value for the selection of the 4-DOFs upper extremity rehabilitation exoskeleton mechanism configurations. The selected exoskeleton can ensure the safety and comfort of stroke patients with upper limb dyskinesia during rehabilitation training.

Details

Industrial Robot: the international journal of robotics research and application, vol. 49 no. 4
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 9 April 2021

Jinlei Zhuang, Ruifeng Li, Chuqing Cao, Yunfeng Gao, Ke Wang and Feiyang Wang

This paper aims to propose a measurement principle and a calibration method of measurement system integrated with serial robot and 3D camera to identify its parameters…

Abstract

Purpose

This paper aims to propose a measurement principle and a calibration method of measurement system integrated with serial robot and 3D camera to identify its parameters conveniently and achieve high measurement accuracy.

Design/methodology/approach

A stiffness and kinematic measurement principle of the integrated system is proposed, which considers the influence of robot weight and load weight on measurement accuracy. Then an error model is derived based on the principle that the coordinate of sphere center is invariant, which can simultaneously identify the parameters of joint stiffness, kinematic and hand-eye relationship. Further, considering the errors of the parameters to be calibrated and the measurement error of 3D camera, a method to generate calibration observation data is proposed to validate both calibration accuracy and parameter identification accuracy of calibration method.

Findings

Comparative simulations and experiments of conventional kinematic calibration method and the stiffness and kinematic calibration method proposed in this paper are conducted. The results of the simulations show that the proposed method is more accurate, and the identified values of angle parameters in modified Denavit and Hartenberg model are closer to their real values. Compared with the conventional calibration method in experiments, the proposed method decreases the maximum and mean errors by 19.9% and 13.4%, respectively.

Originality/value

A new measurement principle and a novel calibration method are proposed. The proposed method can simultaneously identify joint stiffness, kinematic and hand-eye parameters and obtain not only higher measurement accuracy but also higher parameter identification accuracy, which is suitable for on-site calibration.

Details

Industrial Robot: the international journal of robotics research and application, vol. 48 no. 4
Type: Research Article
ISSN: 0143-991X

Keywords

Article
Publication date: 1 June 2004

Nicolas Andreff, Pierre Renaud, Philippe Martinet and Franc¸ois Pierrot

Presents the kinematic calibration of an H4 parallel prototype robot using a vision‐based measuring device. Calibration is performed according to the inverse kinematic model…

Abstract

Presents the kinematic calibration of an H4 parallel prototype robot using a vision‐based measuring device. Calibration is performed according to the inverse kinematic model method, using first the design model then a model developed for calibration purpose. To do so, the end‐effector pose (i.e. position and orientation) has to be measured with the utmost accuracy. Thus, first the practical accuracy of the low‐cost vision‐based measuring system is evaluated to have a precision in the order of magnitude of 10μ_it;m and 10−3° for a 1,024×768 pixel CCD camera. Second, the prototype is calibrated using the easy‐to‐install vision system, yielding a final positioning accuracy of the end‐effector reduced from more than 1cm down to less than 0.5mm. Also provides a discussion on the use of such a method on commercial systems.

Details

Industrial Robot: An International Journal, vol. 31 no. 3
Type: Research Article
ISSN: 0143-991X

Keywords

1 – 10 of over 4000