Search results

1 – 10 of 894
Article
Publication date: 1 February 1989

Bennett J. Price

Uninterruptible Power Supply (UPS) systems are typically designed to provide power to computers for five to thirty minutes after all utility company power has failed. In addition…

Abstract

Uninterruptible Power Supply (UPS) systems are typically designed to provide power to computers for five to thirty minutes after all utility company power has failed. In addition to providing blackout and brownout protection, many UPS systems also protect against spikes, surges, sags, and noise, and some also offer many of the features found in power distribution units (PDUs). The major components or subsystems of a typical UPS system are detailed, and a sample bid specification is appended. Three sidebars discuss UPSs and air conditioning, the maintenance bypass switch (MBS), and literature for further reading.

Details

Library Hi Tech, vol. 7 no. 2
Type: Research Article
ISSN: 0737-8831

Article
Publication date: 3 April 2023

Dangshu Wang, Jiaan Yi, Luwen Song, Xuan Deng, Xinxia Wang and Zhen Dong

This paper aims to solve the problems of large hard switching loss and unclear resonant parameter design in the existing inverter power supply topology.

Abstract

Purpose

This paper aims to solve the problems of large hard switching loss and unclear resonant parameter design in the existing inverter power supply topology.

Design/methodology/approach

This paper proposes a simple and reliable two-stage isolated inverter composed of series quasi-resonant push-pull and external freewheeling diode full-bridge inverter. The power supply topology is analyzed, the topology mode is analyzed, the mathematical model of the converter is established and the DC gain of the converter is deduced. The relationship between the load and the output gain of the resonant tank is presented, a new resonant parameter design method is proposed, and the parameter design of the resonant element of the converter is clarified.

Findings

The resonant components of the converter are designed according to the proposed resonant parameter design method, and the correctness of the method is verified by simulation and the development and testing of a 500 W experimental prototype. After experimental tests, the peak efficiency of the experimental prototype can reach 94%. Because the experimental prototype achieves soft switching, the heat generation of the switch is greatly reduced, so the heavy heat sink is removed, and the volume is reduced by about 30% compared with the traditional power supply, and the total harmonic distortion of the output voltage is about 2%.

Originality/value

The feasibility of the scheme is verified by experiments, which is of great significance for improving the efficiency of the inverter power supply and parameter optimization.

Details

Circuit World, vol. 50 no. 1
Type: Research Article
ISSN: 0305-6120

Keywords

Article
Publication date: 10 October 2022

Xiongmin Tang, Tianhong Jiang, Weizheng Chen, ZhiHong Lin, Zexin Zhou, Chen Yongquan and Miao Zhang

How to use a simple and classical topology to provide a high-efficiency excitation voltage for dielectric barrier discharge (DBD) loads is one of the primary problems to be solved…

Abstract

Purpose

How to use a simple and classical topology to provide a high-efficiency excitation voltage for dielectric barrier discharge (DBD) loads is one of the primary problems to be solved for DBD application fields.

Design/methodology/approach

To address the issue, a set of modes that can generate a high-efficiency pulse excitation voltage in a full-bridge inverter are adopted. With the set of modes, the unique equivalent circuit of DBD loads and the parasitic parameter of the step-up transformer can be fully used. Based on the set of modes, a control strategy for the full-bridge inverter is designed. To test the performance of the power supply, a simulation model is established and an experimental prototype is made with a DBD excimer lamp.

Findings

The simulation and experimental results show that not only a high-efficiency excitation voltage can be generated for the DBD load, but also the soft switching of all power switch is realized. Besides this, with the set of modes and the proposed control strategy, the inverter can operate in a high frequency. Compared with other types of power supplies, the power supply used in the paper can fully take advantage of the potential of the excimer lamp at the same input power.

Originality/value

This work considers that how to use a simple and classical topology to provide a high-efficiency excitation voltage for DBD loads is one of the primary problems to be solved for DBD application fields.

Details

Circuit World, vol. 49 no. 4
Type: Research Article
ISSN: 0305-6120

Keywords

Article
Publication date: 29 July 2021

Xingquan Wang, Xiuyuan Lu, Wei Chen, Fengpeng Wang, Jun Huang, Lingli Liu, Mengchao Li and Kui Lin

This paper aims to improve the general circuit of driving and protection based on insulated gate bipolar transistor (IGBT) in dielectric barrier discharge power supply by…

Abstract

Purpose

This paper aims to improve the general circuit of driving and protection based on insulated gate bipolar transistor (IGBT) in dielectric barrier discharge power supply by designing a novel half-bridge inverter circuit with discrete components.

Design/methodology/approach

With one SG3524 chip, the structure based on discrete components is used to design the IGBT drive circuit. The driving waveform is isolated and sent out by photo-coupler 6N137. The protection circuit is realized by Hall sensor directly detecting the main circuit current, supplemented by a few components, including diodes, resistors, capacitors and triodes. It improves the reliability of the protection circuit.

Findings

In the driving circuit, the phase difference of signals from two channels are 180°. Moreover, when the duty cycle is set at 40%, it can ensure sufficient pulse width modulation response time. In the protection circuit, when over-current occurs, an intermittent output signal is automatically sent out. Furthermore, the over-current response time can be controlled independently. The peak voltage can be adjusted continuously from 0 to 30 kV with its frequency from 8 to 25 kHz and the power output up to 150 W.

Originality/value

The novel circuit of driving and protection makes not only its structure simpler and easier to be realized but also key parameters, such as frequency, the duty cycle and the driving voltage, continuously adjustable. Moreover, the power supply is suitable for other discharges such as corona discharge and jet discharge.

Details

Circuit World, vol. 48 no. 4
Type: Research Article
ISSN: 0305-6120

Keywords

Article
Publication date: 25 June 2019

Piotr Krupski and Henryka Danuta Stryczewska

The research purpose of this paper is to confirm that internal overvoltages in the push–pull power inverter can be used to improve the discharge ignition in the gliding arc…

Abstract

Purpose

The research purpose of this paper is to confirm that internal overvoltages in the push–pull power inverter can be used to improve the discharge ignition in the gliding arc discharge (GAD) plasma reactor.

Design/methodology/approach

Investigations are based on the acquisition of voltage changes that occur together with the development of the discharge column and the imaging the GAD with the use of a high-speed camera.

Findings

The power supply has the distinctive feature of not having the switching overvoltages completely extinguished, as it is in typical push–pull inverters. The overvoltages still exist but only dangerous peaks are cut off. The remaining ones, of a dumped resonance character (Figure 3), are transferred to the secondary coil of the transformer. Correctly shaped overvoltages are used for ignition improvement in the GAD reactor.

Practical implications

GAD plasma reactors have many applications for pollution control, disinfection and sterilization of surfaces and for plasma deposition, surface functionalization, as well as in agricultural and medical treatment. Investigations prove the push–pull inverter’s advantages in comparison with the transformer-type power supply. Properly configured push–pull inverters have good ignition properties and control options, allowing to generate, desirable for many applications, homogeneous non-thermal plasma.

Originality/value

The idea of using switching overvoltages in transistors of push–pull switching-mode power supplies is new and has not been previously used to improve discharges ignition in a non-thermal plasma reactor.

Details

COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, vol. 38 no. 4
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 26 August 2014

Jonas Sjolte, Gaute Tjensvoll and Marta Molinas

The purpose of this paper is to describe the design and function of Fred. Olsen's wave energy converter (WEC) system Lifesaver with special focus on the stand-alone electrical…

Abstract

Purpose

The purpose of this paper is to describe the design and function of Fred. Olsen's wave energy converter (WEC) system Lifesaver with special focus on the stand-alone electrical system that is implemented for operation without grid-connection.

Design/methodology/approach

The paper focus on the detailed design of the DC-Link system that drives the industrial 400 VAC inverters and generators for the production system. The DC-Link is stabilized by an ultra capacitor bank and has no external source or grid-connection.

Findings

The system has been tested through extensive sea trials since April 2012 and has proved its function. Some results from real sea testing are presented.

Practical implications

This paper proves the viability of the specified design and may serve as a basis for the design if similar systems in the future.

Originality/value

This paper presents a WEC system that has proven successful operation through practical tests, and is therefore regarded as a high-value paper as there is limited experience on this subject.

Details

COMPEL: The International Journal for Computation and Mathematics in Electrical and Electronic Engineering, vol. 33 no. 5
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 29 March 2011

Kirubakaran Dhandapani and Rama Reddy Sathi

The purpose of this paper is to present, a novel boost‐active clamp bridge single stage high‐frequency zero voltage soft‐switching‐pulse width modulation (ZVS‐PWM) inverter, which…

Abstract

Purpose

The purpose of this paper is to present, a novel boost‐active clamp bridge single stage high‐frequency zero voltage soft‐switching‐pulse width modulation (ZVS‐PWM) inverter, which converts the utility frequency AC power into high‐frequency AC power with an embedded controller. This single stage high‐frequency inverter is composed of a single‐phase diode bridge rectifier, a non‐smoothing filter, a boost‐active clamp bridge type ZVS‐PWM high‐frequency inverter, and an induction‐heated load with planar type litz wire working coil assembly. Also, the paper discusses how to extend the soft‐switching operation ranges and improve power conversion efficiency.

Design/methodology/approach

The proposed converter is simulated and it is implemented using embedded controller.

Findings

It was found that the single stage high‐frequency induction heating (IH) inverter using boosted voltage function can eliminate the DC and low‐frequency components of the working coil current and reduce the power dissipation of the circuit components and switching devices.

Originality/value

The paper shows that the PWM HF inverter is preferred for IH, since it has reduced switching losses and switching stresses. The paper can be extended to PC‐based wireless control, which can be part of a distributed control system in major industrial heating systems.

Details

Journal of Engineering, Design and Technology, vol. 9 no. 1
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 5 May 2015

Branislav Dobrucky, Michal Frivaldsky and Juraj Koscelnik

Many electric circuits feature some type of non-linearity of their used devices. Non-linear resistors or inductors could be typical examples. Also, all semiconductor devices are…

Abstract

Purpose

Many electric circuits feature some type of non-linearity of their used devices. Non-linear resistors or inductors could be typical examples. Also, all semiconductor devices are in their nature non-linear ones. The simulation models are very important parts of the design of the devices in various fields of industry. Multiply (multiple) simulation, verified by the measurement on the physical sample, help to improve the converter design by understanding the current and voltage behavior of non-linear elements. The paper aims to discuss these issues.

Design/methodology/approach

Mathematical model of LCTLC inverter was made. Fictitious exciting function was applied on LCTLC inverter model. The non-linear inductance with the real core EFD model has been created and consequentially used for MatLab simulation experiments. MatLab and OrCAD/PSpice simulation results were compared with experimental measurements carried out on physical sample.

Findings

The authors have found how to simulate non-linear resonant circuits within mathematical apparatus using fictitious exciting function method. The authors provided comparisons between proposed simulation mathematical model and relevant physical sample. Multiply simulations can help to improve the converter design by understanding the current and voltage behavior of non-linear elements.

Research limitations/implications

The proposed method is applicable for simulation purposes. The only limitation is that MatLab model does not include hysteresis curve of the core, therefore it has to be modeled.

Practical implications

The design of power supplies (switched mode power supplies, UPS and resonant inverter).

Originality/value

Research in the area of behaviors of non-linear components in resonant circuits.

Details

COMPEL: The International Journal for Computation and Mathematics in Electrical and Electronic Engineering, vol. 34 no. 3
Type: Research Article
ISSN: 0332-1649

Keywords

Article
Publication date: 2 February 2024

Xiongmin Tang, Zexin Zhou, Yongquan Chen, ZhiHong Lin, Miao Zhang and Xuecong Li

Dielectric barrier discharge (DBD) is widely used in the treatment of skin disease, surface modification of material and other fields of electronics. The purpose of this paper is…

Abstract

Purpose

Dielectric barrier discharge (DBD) is widely used in the treatment of skin disease, surface modification of material and other fields of electronics. The purpose of this paper is to design a high-performance power supply with a compact structure for excimer lamps in electronics application.

Design/methodology/approach

To design a high-performance power supply with a compact structure remains a challenge for excimer lamps in electronics application, a current-source type power supply in a single stage with power factor correction (PFC) is proposed. It consists of an excitation voltage generation unit and a PFC unit. By planning the modes of the excitation voltage generation unit, a bipolar pulse excitation voltage with a high rising and falling rate is generated. And a high power factor (PF) on the AC side is achieved by the interaction of a non-controlled rectifier and two inductors.

Findings

The experimental results show that not only a high-frequency and high-voltage bipolar pulse excitation voltage with a high average rising and falling rate (7.51GV/s) is generated, but also a high PF (0.992) and a low total harmonic distortion (5.54%) is obtained. Besides, the soft-switching of all power switches is realized. Compared with the sinusoidal excitation power supply and the current-source power supply, the proposed power supply in this paper can take advantage of the potential of excimer lamps.

Originality/value

A new high-performance power supply with a compact structure for DBD type excimer lamps is proposed. The proposed power supply can work stably in a wide range of frequencies, and the smooth regulation of the discharge power of the excimer lamp can be achieved by changing the switching frequency. The ideal excitation can be generated, and the soft switching can be realized. These features make this power supply a key player in the outstanding performance of the DBD excimer lamps application.

Details

Circuit World, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0305-6120

Keywords

Article
Publication date: 26 June 2009

J.F. Wang, B. Chen, H.B. Chen and S.B. Chen

The purpose of this paper is to analyze the characteristics of sound during gas tungsten argon welding (GTAW), which is very important to effectively monitor the welding quality…

Abstract

Purpose

The purpose of this paper is to analyze the characteristics of sound during gas tungsten argon welding (GTAW), which is very important to effectively monitor the welding quality in future by using the information extracted from sound.

Design/methodology/approach

The hardware used in the experiment is described. Then the paper researches the influence of welding techniques (gas flow, welding speed, welding current, and arc length) on arc sound and the distribution of the welding sound field. Finally, the relation between welding power and sound are studied based on Fourier transforms and recursive least square methods.

Findings

The sound pressure is affected greatly by gas flow, arc length, and current; welding sound source obeys the dipole model; the sound can be better predicted when the three orders derivative of the welding power are combined together.

Originality/value

This paper provides a new insight into welding sound resource model and a detailed analysis of the influence of the welding sound caused by welding techniques.

Details

Sensor Review, vol. 29 no. 3
Type: Research Article
ISSN: 0260-2288

Keywords

1 – 10 of 894