Search results

1 – 10 of 29
Article
Publication date: 5 December 2023

Shahe Liang, Zhiqiang Zhang and Aiqun Li

A new type of variable damping viscous damper is developed to meet the settings of different damping parameter values at different working stages. Its main principle and design…

Abstract

Purpose

A new type of variable damping viscous damper is developed to meet the settings of different damping parameter values at different working stages. Its main principle and design structure are introduced, and the two-stage and multi-stage controllable damping methods are proposed.

Design/methodology/approach

The theoretical calculation formulas of the damping force of power-law fluid variable damping viscous damper at elongated holes are derived, aiming to provide a theoretical basis for the development and application of variable damping viscous dampers. For the newly developed variable damping viscous damper, the dynamic equations for the seismic reduction system with variable damping viscous dampers under a multi-degree-of-freedom system are established. A feasible calculation and analysis method is proposed to derive the solution process of time history analysis. At the same time, a program is also developed using Matlab. The dynamic full-scale test of a two-stage variable damping viscous damper was conducted, demonstrating that the hysteresis curve is complete and the working condition is stable.

Findings

Through the calculation and analysis of examples, the results show that the seismic reduction effect of high and flexible buildings using the seismic reduction system with variable damping viscous dampers is significant. The program developed is used to analyze the seismic response of a broadcasting tower using a variable damping TMD system under large earthquakes. The results indicate that the installation of variable damping viscous dampers can effectively control the maximum inter-story displacement response of TMD water tanks and can effectively consume seismic energy.

Originality/value

This method can provide a guarantee for the safe and effective operation of TMD in wind and vibration control.

Details

International Journal of Structural Integrity, vol. 15 no. 1
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 2 January 2020

Haixu Yang, Feng Zhu, Haibiao Wang, Liang Yu and Ming Shi

The purpose of this paper is to describe the structure of nonlinear dampers and the dynamic equations, and nonlinear realization principles and optimize the parameters of…

Abstract

Purpose

The purpose of this paper is to describe the structure of nonlinear dampers and the dynamic equations, and nonlinear realization principles and optimize the parameters of nonlinear dampers. Using the finite element method to analyze the seismic performance of the frame structure with shock absorber.

Design/methodology/approach

The nonlinear shock absorber was installed in a six-storey reinforced concrete frame structure to study its seismic performance. The main structure was designed according to the eight degree seismic fortification intensity, and the time history dynamic analysis was carried out by Abaqus finite element software. EL-Centro, Taft and Wenchuan seismic record were selected to analyze the seismic response of the structure under different magnitudes and different acceleration peaks.

Findings

Through the principle study and parameter analysis of the nonlinear shock absorber, combined with the finite element simulation results, the shock absorption performance and shock absorption effect of the nonlinear energy sink (NES) nonlinear shock absorber are given as follows: first, the damping of the NES shock absorber is satisfied, and the linear spring stiffness and nonlinear stiffness of the shock absorber are based on the relationship k1=kn×kl2, so that the spring design length is fixed, and the linear stiffness of the shock absorber can be obtained. The nonlinear shock absorber has the characteristics of high rigidity and frequency bandwidth, so that the frequency is infinitely close to the frequency of the main structure, and when the mass of the shock absorber satisfies between 0.056 and 1, a good shock absorption effect can be obtained, and the reinforced concrete with the shock absorber is obtained. The frame structure can effectively reduce the seismic response, increase the natural vibration period of the structure and reduce the damage loss of the structure. Second, the spacer and each additional shock absorber have a small difference in shock absorption effect. After the shock absorber parameters are accurately calculated, the number of installations does not affect the shock absorption effect of the structure. Therefore, the shock absorber is properly constructed and accurately calculated. Parameters can reduce costs.

Originality/value

New shock absorbers reduce earthquake-induced damage to buildings.

Details

Multidiscipline Modeling in Materials and Structures, vol. 16 no. 4
Type: Research Article
ISSN: 1573-6105

Keywords

Article
Publication date: 29 September 2021

Gangling Hou, Yu Liu, Tao Wang, Binsheng Wang, Tianshu Song, Menghan Sun and Yong Li

An inter-story isolation structure (IIS) for AP1000 nuclear power plants (NPPs) is provided to resolve the conflict of seismic safety and the optimal location of air intakes.

Abstract

Purpose

An inter-story isolation structure (IIS) for AP1000 nuclear power plants (NPPs) is provided to resolve the conflict of seismic safety and the optimal location of air intakes.

Design/methodology/approach

The effect of passive cooling system (PCS) is better with lower altitude of air intakes than that in the original design of AP1000 NPPs. Seismic performances of IIS NPPs, including the seismic responses, damping frequency bandwidth and seismic reduction robustness, are improved by combining the position of air intakes lower and the optimal design method.

Findings

Theoretical analysis and numerical simulation are illustrated that the seismic reduction failure of IIS NPPs is the lowest probability of occurrence when PCS has highest working efficiency.

Originality/value

The IIS NPPs can transfer the contradiction between PCS work efficiency and seismic safety of NPPs to the mutual promotion of them.

Details

Engineering Computations, vol. 39 no. 3
Type: Research Article
ISSN: 0264-4401

Keywords

Article
Publication date: 23 January 2020

Tanuja Singh, Megha Kalra and Anil Kumar Misra

The paper aims to focus on adjacent buildings response, equipped with damper, to analyze the vibration reduction in the nearby buildings. The nearby buildings were also equipped…

Abstract

Purpose

The paper aims to focus on adjacent buildings response, equipped with damper, to analyze the vibration reduction in the nearby buildings. The nearby buildings were also equipped with dampers. The occurrence of adjacent buildings with adequate or inadequate space in between is a common phenomenon. However, many a times not much attention is paid to provide or check gap adequacy or to connect the two buildings suitably to avoid pounding of two structures on each other. This study emphasizes the utility of providing a damper in between two adjacent buildings for better performance.

Design/methodology/approach

The two steel structures taken for study are prototype of two structures normally found in industrial structure such as power plant, where in one of boiler structure is often tall and braced and short structure of turbine building which is moment resistant, modeled in SAP. There could be similar such structures which are often connected to a platform or a walkway with a sliding end, so as not to transfer horizontal force to other structures. If the advantage of stiffness of tall braced structure is taken into account, shorter structure can be suitably connected to braced structure to transfer forces during seismic cases under nonlinear conditions, thereby avoiding pounding (incase gap is too less), reducing response and thus optimizing the section sizes. The structures were subjected to El Centro earthquake, to simulate MCE (which could be the other site TH scaled up as desired for real site PGA), and damper location and parameters were varied to find optimum value which offers reduced base shear, reduced top floor displacement and minimum inter story drift and highest energy absorption by fluid viscous dampers.

Findings

The findings show that taller structures, which are braced, have more stiffness; the effect of damper is more pronounced in reducing displacement of shorter moment resistant structure to the tune of 60%, with suitably defined Cd value which is found to be 600 KNs/m for the present study. Thus, advantage of stiffener structure is taken to leverage and reduce the displacement of shorter moment resistant structure in reducing its displacement under nonlinear conditions of seismic case.

Originality/value

This work shows the original findings, of the adjacent buildings response, equipped with damper, to analyze the vibration reduction on other buildings which were planned to be constructed nearby.

Details

Journal of Engineering, Design and Technology , vol. 18 no. 5
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 13 February 2020

Gangling Hou, Yu Liu, Meng Li, Menghan Sun, Feng Sun, Xiuyun Zhu, Rong Pan and Dongyu Zhang

In recent years, a new type of double-layered containment structure of nuclear power plant has been built in China, named ACP1000 NNP. This paper aims to propose a new method to…

Abstract

Purpose

In recent years, a new type of double-layered containment structure of nuclear power plant has been built in China, named ACP1000 NNP. This paper aims to propose a new method to mitigate the seismic responses of this type of the structure.

Design/methodology/approach

The new base isolation structure (BIS)- tuned mass damper (TMD) structure was proposed and implemented only by modifying the connection between various components of NPPs, and the application of this concept design in ACP1000 was skillfully realized.

Findings

The new structure adopts the combination of structural form and function, adopts appropriate amplification of the seismic response of the secondary component, possesses advantages in explicit damping mechanism, good damping effect, robustness of seismic structures, simple implementation process, etc., and meets the special seismic safety requirements of the NPPs.

Originality/value

This seismic and hazard mitigation and BIS-TMD structure can avoid the risk of ACP1000 accidents caused by horizontal earthquakes.

Details

Engineering Computations, vol. 37 no. 6
Type: Research Article
ISSN: 0264-4401

Keywords

Article
Publication date: 30 January 2019

Said Hicham Boukhalkhal, Abd Nacer Touati Ihaddoudène, Luis Filipe Da Costa Neves and Wafa Madi

The purpose of this paper is to investigate the static and dynamic inelastic response of rigid and semi-rigid connections of steel structures with concrete-filled steel tube…

146

Abstract

Purpose

The purpose of this paper is to investigate the static and dynamic inelastic response of rigid and semi-rigid connections of steel structures with concrete-filled steel tube (CFST) columns built in high seismic areas, and to compare it with those with open section columns.

Design/methodology/approach

CFST columns are frequently used in moment resistant steel frames located in seismic areas due to their inherent advantages, including their ductility, energy absorption capacity as well as their high bearing capacity. The smart combination of steel and concrete makes it possible to benefit from the advantages of both components to the maximum. This research work presents the nonlinear dynamic response of moment resistant steel frames with CFST columns, with rigid or semi-rigid connections, built in high seismic areas, according to the Algerian seismic code RPA 99/2003, European EC8 and American FEMA 356 to show the nonlinear characteristics of this type of structures, and their advantages over steel frames with open section columns.

Findings

The paper presents the advantages of using CFST columns with rigid and semi-rigid connections on the seismic response of portal steel frames. A high performance level in terms of ductility, plastic hinges distribution and their order of appearance has been obtained. It also shows the low effect of seismic loading on the structural elements with CFST columns compared to structures with open section columns.

Originality/value

The investigation of the numerical results has shown the possibility of their use in the seismic areas for their adequate performance, and also with respect to the design limits specified in the seismic guidelines. In addition, this study represents a first step to develop seismic performance factors for steel structures with CFST columns in Algeria, where the Algerian code do not include a comprehensive specification for the composite steel structures.

Details

International Journal of Structural Integrity, vol. 10 no. 2
Type: Research Article
ISSN: 1757-9864

Keywords

Article
Publication date: 17 February 2022

Md. Habibur Rahman Sobuz, Md. Montaseer Meraz, Ayan Saha, Abu Sayed Mohammad Akid, Noor Md. Sadiqul Hasan, Mizanoor Rahman and Md. Abu Safayet

This study aims to present the variations of optimal seismic control of reinforced cement concrete (RCC) structure using different structural systems. Different third-dimensional…

Abstract

Purpose

This study aims to present the variations of optimal seismic control of reinforced cement concrete (RCC) structure using different structural systems. Different third-dimensional mathematical models are used to examine the responses of multistory flexibly connected frames subjected to earthquake excitations.

Design/methodology/approach

This paper examined a G + 50 multi-storied high-rise structure, which is analyzed using different combinations of moment resistant frames, shear walls, seismic outrigger systems and seismic dampers to observe the effectiveness during ground motion against soft soil conditions. The damping coefficients of added dampers, providing both upper and lower levels are taken into consideration. A finite element modeling and analysis is generated. Then the nature of the structure exposed to ground motion is captured with response spectrum analysis, using BNBC-2020 for four different seismic zones in Bangladesh.

Findings

The response of the structure is investigated according to the amplitude of the displacements, drifts, base shear, stiffness and torsion. The numerical results indicate that adding dampers at the base level can be the most effective against seismic control. However, placing an outrigger bracing system at the middle and top end with shear wall can be the most effective for controlling displacements and drifts.

Originality/value

The response of high-rise structures to seismic forces in Bangladesh’s soft soil conditions is examined at various levels in this study. This study is an original research which contributes to the knowledge to build earthquake resisting high-rises in Bangladesh.

Details

Journal of Engineering, Design and Technology , vol. 22 no. 3
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 6 February 2024

Farshid Rashidiyan, Seyed Rasoul Mirghaderi, Saeed Mohebbi and Sina Kavei

This research study focuses on investigating the seismic performance of non-straight beams in steel structures and exploring the mechanism by which plastic hinges are formed…

Abstract

Purpose

This research study focuses on investigating the seismic performance of non-straight beams in steel structures and exploring the mechanism by which plastic hinges are formed within these beams. The findings contribute to the understanding of their behaviour under seismic loads and offer insights into their potential for enhancing the lateral resistance of the structure. The abstract of the study highlights the significance of corners in structural plans, where non-coaxial columns, diagonal elements or beams deviating from a straight path are commonly observed. Typically, these non-straight beams are connected to the columns using pinned connections, despite their unknown seismic behaviour. Recognizing the importance of generating plastic hinges in special moment resisting frames and the lack of previous research on the involvement of these non-straight beams, this study aims to address this knowledge gap.

Design/methodology/approach

This study examines the seismic behaviour and plastic hinge formation of non-straight beams in steel structures. Non-straight beams are beams that connect non-coaxial columns and diagonal elements, or deviate from a linear path. They are usually pinned to the columns, and their seismic contribution is unknown. A critical case with a 12-m non-straight beam is analysed using Abaqus software. Different models are created with varying cross-section shapes and connection types between the non-straight beams. The models are subjected to lateral monotonic and cyclic loads in one direction. The results show that non-straight beams increase the lateral stiffness, strength and energy dissipation of the models compared to disconnected beams that act as two cantilevers.

Findings

The analysis results reveal several key findings. The inclusion of non-straight beams in the models leads to increased lateral stiffness, strength and energy dissipation compared to the scenario where the beams are disconnected and act as two cantilever beams. Plastic hinges are formed at both ends of the non-straight beam when a 3% drift is reached, contributing to energy damping and introducing plasticity into the structure. These results strongly suggest that non-straight beams play a significant role in enhancing the lateral resistance of the system. Based on the seismic analysis results, this study recommends the utilization of non-straight beams in special moment frames due to the formation of plastic hinges within these beams and their effective participation in resisting lateral seismic loads. This research fills a critical gap in understanding the behaviour of non-straight beams and provides valuable insights for structural engineers involved in the design and analysis of steel structures.

Originality/value

The authors believe that this research will greatly contribute to the knowledge and understanding of the seismic performance of non-straight beams in steel structures.

Article
Publication date: 31 July 2020

Min Zhang and Huaying Pang

The purpose of this paper is to equip damping performance of frame structure with viscoelastic dampers connected to supports is studied, the influence of the damper supports and…

Abstract

Purpose

The purpose of this paper is to equip damping performance of frame structure with viscoelastic dampers connected to supports is studied, the influence of the damper supports and the damping parameters on the damping performance of the structure is analyzed, the practical economical arrangement of viscoelastic dampers on each floor is researched and the calculation method of the seismic effect of the damping structure is presented.

Design/methodology/approach

In this paper, Fourier transform is applied to the vibration equation of the structure equipped with viscoelastic dampers, the frequency domain solution of the vibration equation is solved and the time-domain solution of the equation is obtained by Fourier inverse transform, from which effects of the support coefficient and the relaxing time coefficient on the seismic response of the structure are analyzed.

Findings

The seismic effect of each floor and the bottom shear force of each vibration mode of a structure are analyzed, which indicates that the relaxing time coefficient of the damper should be controlled reasonably.

Originality/value

In this paper, the vibration equation is solved in the frequency domain for frame structure equipped with viscoelastic dampers. The time-domain solution of the equation is obtained by Fourier inverse transform, from which the seismic response of frame structure equipped with viscoelastic damper connected to supports is studied.

Details

Engineering Computations, vol. 38 no. 2
Type: Research Article
ISSN: 0264-4401

Keywords

Article
Publication date: 10 June 2022

Guodong Li, Wenhan Liu and Guangzhi Feng

Aiming at the characteristics of large stiffness, low ductility, and poor energy dissipation capacity of cross-laminated timber (CLT) shear wall, a method of opening vertical…

Abstract

Purpose

Aiming at the characteristics of large stiffness, low ductility, and poor energy dissipation capacity of cross-laminated timber (CLT) shear wall, a method of opening vertical joints and adding low-yield dampers in CLT shear wall is proposed to improve its energy dissipation capacity and ductility.

Design/methodology/approach

The finite element model of CLT shear walls with low-yield dampers and dampers assembly was established by ABAQUS. The structural shape of low-yield dampers that meet the requirements of vertical joints in CLT shear walls is studied by numerical analysis. The influence of the number and position of low-yield dampers on the energy dissipation of the shear wall system is studied.

Findings

The results show that the low-yield damper with diamond openings should be used in the CLT shear wall, and the energy dissipation effect is the best when the CLT shear wall is uniformly covered with low-yield dampers. After the uniform arrangement of four groups of low-yield steel dampers, the energy consumption of the CLT shear wall increases by 75.38%, and the ductility increases by 13.22%.

Originality/value

There are few studies on replacing connectors between shear walls with low-yield steel dampers, and rectangular soft steel dampers are prone to stress concentration and poor deformation capacity. Therefore, this paper establishes the model of perforated low-yield damper and CLT and makes numerical analysis to determine the opening form, geometric parameters of low-yield damper, and the optimal layout scheme in CLT shear wall.

Details

Multidiscipline Modeling in Materials and Structures, vol. 18 no. 3
Type: Research Article
ISSN: 1573-6105

Keywords

1 – 10 of 29