Search results

1 – 10 of 141
Open Access
Article
Publication date: 6 March 2024

Chuloh Jung, Muhammad Azzam Ismail, Mohammad Arar and Nahla AlQassimi

This study aims to evaluate the efficiency of various techniques for enhancing indoor air quality (IAQ) in construction. It analyzed the alterations in the concentration of indoor

Abstract

Purpose

This study aims to evaluate the efficiency of various techniques for enhancing indoor air quality (IAQ) in construction. It analyzed the alterations in the concentration of indoor air pollutants over time for each product employed in controlling pollution sources and removing it, which included eco-friendly substances and adsorbents. The study will provide more precise and dependable data on the effectiveness of these control methods, ultimately supporting the creation of more efficient and sustainable approaches for managing indoor air pollution in buildings.

Design/methodology/approach

The research investigates the impact of eco-friendly materials and adsorbents on improving indoor air quality (IAQ) in Dubai's tall apartment buildings. Field experiments were conducted in six units of The Gate Tower, comparing the IAQ of three units built with “excellent” grade eco-friendly materials with three built with “good” grade materials. Another experiment evaluated two adsorbent products (H and Z) in the Majestic Tower over six months. Results indicate that “excellent” grade materials significantly reduced toluene emissions. Adsorbent product Z showed promising results in pollutant reduction, but there is concern about the long-term behavior of adsorbed chemicals. The study emphasizes further research on household pollutant management.

Findings

The research studied the effects of eco-friendly materials and adsorbents on indoor air quality in Dubai's new apartments. It found that apartments using “excellent” eco-friendly materials had significantly better air quality, particularly reduced toluene concentrations, compared to those using “good” materials. However, high formaldehyde (HCHO) emissions were observed from wood products. While certain construction materials led to increased ethylbenzene and xylene levels, adsorbent product Z showed promise in reducing pollutants. Yet, there is a potential concern about the long-term rerelease of these trapped chemicals. The study emphasizes the need for ongoing research in indoor pollutant management.

Research limitations/implications

The research, while extensive, faced limitations in assessing the long-term behavior of adsorbed chemicals, particularly the potential for rereleasing trapped pollutants over time. Despite the study spanning a considerable period, indoor air pollutant concentrations in target households did not stabilize, making it challenging to determine definitive improvement effects and reduction rates among products. Comparisons were primarily relative between target units, and the rapid rise in pollutants during furniture introduction warrants further examination. Consequently, while the research provides essential insights, it underscores the need for more prolonged and comprehensive evaluations to fully understand the materials' and adsorbents' impacts on indoor air quality.

Practical implications

The research underscores the importance of choosing eco-friendly materials in new apartment constructions for better IAQ. Specifically, using “excellent” graded materials can significantly reduce harmful pollutants like toluene. However, the study also highlights that certain construction activities, such as introducing furniture, can rapidly elevate pollutant levels. Moreover, while adsorbents like product Z showed promise in reducing pollutants, there is potential for adsorbed chemicals to be rereleased over time. For practical implementation, prioritizing higher-grade eco-friendly materials and further investigation into furniture emissions and long-term behavior of adsorbents can lead to healthier indoor environments in newly built apartments.

Originality/value

The research offers a unique empirical assessment of eco-friendly materials' impact on indoor air quality within Dubai's rapidly constructed apartment buildings. Through field experiments, it directly compares different material grades, providing concrete data on pollutant levels in newly built environments. Additionally, it explores the efficacy of specific adsorbents, which is of high value to the construction and public health sectors. The findings shed light on how construction choices can influence indoor air pollution, offering valuable insights to builders, policymakers and residents aiming to promote public health and safety in urban living spaces.

Details

Smart and Sustainable Built Environment, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2046-6099

Keywords

Open Access
Article
Publication date: 5 August 2021

Ulrika Uotila, Arto Saari, Juha-Matti Kalevi Junnonen and Lari Eskola

Poor indoor air quality in schools is a worldwide challenge that poses health risks to pupils and teachers. A possible response to this problem is to modify ventilation…

2508

Abstract

Purpose

Poor indoor air quality in schools is a worldwide challenge that poses health risks to pupils and teachers. A possible response to this problem is to modify ventilation. Therefore, the purpose of this paper is to pilot a process of generating alternatives for ventilation redesign, in an early project phase, for a school to be refurbished. Here, severe problems in indoor air quality have been found in the school.

Design/methodology/approach

Ventilation redesign is investigated in a case study of a school, in which four alternative ventilation strategies are generated and evaluated. The analysis is mainly based on the data gathered from project meetings, site visits and the documents provided by ventilation and condition assessment consultants.

Findings

Four potential strategies to redesign ventilation in the case school are provided for decision-making in refurbishment in the early project phase. Moreover, the research presents several features to be considered when planning the ventilation strategy of an existing school, including the risk of alterations in air pressure through structures; the target number of pupils in classrooms; implementing and operating costs; and the size of the space that ventilation equipment requires.

Research limitations/implications

As this study focusses on the early project phase, it provides viewpoints to assist decision-making, but the final decision requires still more accurate calculations and simulations.

Originality/value

This study demonstrates the decision-making process of ventilation redesign of a school with indoor air problems and provides a set of features to be considered. Hence, it may be beneficial for building owners and municipal authorities who are engaged in planning a refurbishment of an existing building.

Details

Facilities , vol. 40 no. 15/16
Type: Research Article
ISSN: 0263-2772

Keywords

Open Access
Article
Publication date: 3 February 2023

Modupe Cecilia Mewomo, James Olaonipekun Toyin, Comfort Olubukola Iyiola and Olusola Raphael Aluko

The present shift and change in the human lifestyle across the world are undeniable. Currently, individuals spend a substantial amount of time indoors due to the global COVID-19…

2655

Abstract

Purpose

The present shift and change in the human lifestyle across the world are undeniable. Currently, individuals spend a substantial amount of time indoors due to the global COVID-19 pandemic that strikes the entire world. This change in human lifestyle has devastating effects on human health and productivity. As a result, the influence of indoor environmental quality (IEQ) on the health and productivity of building users becomes a critical field of research that requires immediate attention. As a result, the purpose of this study is to review the state-of-the-art literature by establishing a connection between the factors that influence health and productivity in any given indoor environment.

Design/methodology/approach

The methodology involves a thorough review of selected published journals from 1983 to 2021, and the result was analysed through content analysis. The search included journal articles, books and conference proceedings on the critical factors influencing IEQ and their impact on building occupants, which was sourced from different databases such as ScienceDirect, Taylor, GoogleScholar and Web of Science.

Findings

The findings from the 90 selected articles revealed four critical factors influencing the quality of the indoor environment and are categorised into; indoor air quality, indoor thermal comfort, visual comfort and acoustic comfort. The findings suggested that when developing a system for controlling the quality of the indoor environment, the indoor air quality, indoor thermal comfort, visual comfort and acoustic comfort should be taken into account.

Originality/value

The indoor environment deeply impacts the health of individuals in their living and work environments. Industry must have a moral responsibility to provide health facilities in which people and workers feel satisfies and give conditions for prosperity. Addressing these essential aspects will not only help the decision-making process of construction professionals but also encourages innovative construction techniques that will enhance the satisfaction, wellness and performance of building occupants.

Details

Journal of Engineering, Design and Technology , vol. 21 no. 2
Type: Research Article
ISSN: 1726-0531

Keywords

Open Access
Article
Publication date: 28 October 2021

Ben M. Roberts, David Allinson and Kevin J. Lomas

Accurate values for infiltration rate are important to reliably estimate heat losses from buildings. Infiltration rate is rarely measured directly, and instead is usually…

2086

Abstract

Purpose

Accurate values for infiltration rate are important to reliably estimate heat losses from buildings. Infiltration rate is rarely measured directly, and instead is usually estimated using algorithms or data from fan pressurisation tests. However, there is growing evidence that the commonly used methods for estimating infiltration rate are inaccurate in UK dwellings. Furthermore, most prior research was conducted during the winter season or relies on single measurements in each dwelling. Infiltration rates also affect the likelihood and severity of summertime overheating. The purpose of this work is to measure infiltration rates in summer, to compare this to different infiltration estimation methods, and to quantify the differences.

Design/methodology/approach

Fifteen whole house tracer gas tests were undertaken in the same test house during spring and summer to measure the whole building infiltration rate. Eleven infiltration estimation methods were used to predict infiltration rate, and these were compared to the measured values. Most, but not all, infiltration estimation methods relied on data from fan pressurisation (blower door) tests. A further four tracer gas tests were also done with trickle vents open to allow for comment on indoor air quality, but not compared to infiltration estimation methods.

Findings

The eleven estimation methods predicted infiltration rates between 64 and 208% higher than measured. The ASHRAE Enhanced derived infiltration rate (0.41 ach) was closest to the measured value of 0.25 ach, but still significantly different. The infiltration rate predicted by the “divide-by-20” rule of thumb, which is commonly used in the UK, was second furthest from the measured value at 0.73 ach. Indoor air quality is likely to be unsatisfactory in summer when windows are closed, even if trickle vents are open.

Practical implications

The findings have implications for those using dynamic thermal modelling to predict summertime overheating who, in the absence of a directly measured value for infiltration rate (i.e. by tracer gas), currently commonly use infiltration estimation methods such as the “divide-by-20” rule. Therefore, infiltration may be overestimated resulting in overheating risk and indoor air quality being incorrectly predicted.

Originality/value

Direct measurement of air infiltration rate is rare, especially multiple tests in a single home. Past measurements have invariably focused on the winter heating season. This work is original in that the tracer gas technique used to measure infiltration rate many times in a single dwelling during the summer. This work is also original in that it quantifies both the infiltration rate and its variability, and compares these to values produced by eleven infiltration estimation methods.

Details

International Journal of Building Pathology and Adaptation, vol. 41 no. 1
Type: Research Article
ISSN: 2398-4708

Keywords

Open Access
Article
Publication date: 15 December 2023

Francis Olawale Abulude, Domenico Suriano, Samuel Dare Oluwagbayide, Akinyinka Akinnusotu, Ifeoluwa Ayodeji Abulude and Emmanuel Awogbindin

This study aimed to characterize the concentrations of indoor pollutants (such as carbon dioxide (CO2), ozone (O3), nitrogen dioxide (NO2) and sulfur dioxide (SO2), as well as…

Abstract

Purpose

This study aimed to characterize the concentrations of indoor pollutants (such as carbon dioxide (CO2), ozone (O3), nitrogen dioxide (NO2) and sulfur dioxide (SO2), as well as particulate matter (PM) (PM1, PM2.5 and PM10) in Akure, Nigeria, as well as the relationship between the parameters’ concentrations.

Design/methodology/approach

The evaluation, which lasted four months, used a low-cost air sensor that was positioned two meters above the ground. All sensor procedures were correctly carried out.

Findings

CO2 (430.34 ppm), NO2 (93.31 ppb), O3 (19.94 ppb), SO2 (40.87 ppb), PM1 (29.31 µg/m3), PM2.5 (43.56 µg/m3), PM10 (50.70 µg/m3), temperature (32.4°C) and relative humidity (50.53%) were the average values obtained. The Pearson correlation depicted the relationships between the pollutants and weather factors. With the exception of April, which had significant SO2 (18%) and low PM10 (49%) contributions, NO2 and PM10 were the most common pollutants in all of the months. The mean air quality index (AQI) for NO2 indicated that the AQI was “moderate” (51–100). In contrast to SO2, whose AQI ranged from “moderate” to “very unhealthy,” O3's AQI ranged from “good” (50) to “unhealthy” (151–200). Since PM1, PM2.5 and PM10 made up the majority of PC1’s contribution, both PM2.5 and PM10 were deemed “hazardous.”

Practical implications

The practical implication of indoor air pollution is long-term health effects, including heart disease, lung cancer and respiratory diseases such as emphysema. Indoor air pollution can also cause long-term damage to people’s nerves, brain, kidneys, liver and other organs.

Originality/value

Lack of literature in terms of indoor air quality (IAQ) in Akure, Ondo State. With this work, the information obtained will assist all stakeholders in policy formulation and implementation. Again, the low-cost sensor used is new to this part of the world.

Details

Arab Gulf Journal of Scientific Research, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1985-9899

Keywords

Open Access
Article
Publication date: 2 February 2023

Ulrika Uotila and Arto Saari

Poor indoor air quality (IAQ) contributing to occupants’ health symptoms is a universal, typically ventilation-related, problem in schools. In cold climates, low-cost strategies…

Abstract

Purpose

Poor indoor air quality (IAQ) contributing to occupants’ health symptoms is a universal, typically ventilation-related, problem in schools. In cold climates, low-cost strategies to improve IAQ in a naturally ventilated school are rare since conventional methods, such as window opening, are often inappropriate. This paper aims to present an investigation of strategies to relieve health symptoms among school occupants in naturally ventilated school in Finland.

Design/methodology/approach

A case study approach is adopted to thoroughly investigate the process of generating the alternatives of ventilation redesign in a naturally ventilated school where there have been complaints of health symptoms. First, the potential sources of the occupants’ symptoms are identified. Then, the strategies aiming to reduce the symptoms are compared and evaluated.

Findings

In a naturally ventilated school, health symptoms that are significantly caused by insufficient ventilation can be potentially reduced by implementing a supply and exhaust ventilation system. Alternatively, it is possible to retain the natural ventilation with reduced number of occupants. The selected strategy would depend considerably on the desired number of users, the budget and the possibilities to combine the redesign of ventilation with other refurbishment actions. Furthermore, the risk of poorer indoor air caused by the refurbishment actions must also be addressed and considered.

Practical implications

This study may assist municipal authorities and school directors in decisions concerning improvement of classroom IAQ and elimination of building-related symptoms. This research provides economic aspects of alternative strategies and points out the risks related to major refurbishment actions.

Originality/value

Since this study presents a set of features related to indoor air that contribute to occupants’ health as well as matters to be considered when aiming to decrease occupants’ symptoms, it may be of assistance to municipal authorities and practitioners in providing a healthier indoor environment for pupils and teachers.

Details

Facilities, vol. 41 no. 15/16
Type: Research Article
ISSN: 0263-2772

Keywords

Open Access
Article
Publication date: 11 November 2022

Sara Zanni, Matteo Mura, Mariolina Longo, Gabriella Motta and Davide Caiulo

This study aims to provide a comprehensive framework for the study of indoor air quality (IAQ) in hospitality premises. The goal is to identify the drivers of air pollution, both…

1849

Abstract

Purpose

This study aims to provide a comprehensive framework for the study of indoor air quality (IAQ) in hospitality premises. The goal is to identify the drivers of air pollution, both at the exogenous and endogenous level, to generate insights for facility managers.

Design/methodology/approach

The complexity of hospitality premises requires an integrated approach to properly investigate IAQ. The authors develop an overarching framework encompassing a monitoring method, based on real-time sensors, a technological standard and a set of statistical analyses for the assessment of both IAQ performance and drivers, based on correlation analyses, analysis of variance and multivariate regressions.

Findings

The findings suggest that the main drivers of IAQ differ depending on the area monitored: areas in contact with the outdoors or with high ventilation rates, such as halls, are affected by outdoor air quality more than guestrooms or fitness areas, where human activities are the main sources of contamination.

Research limitations/implications

The results suggest that the integration of IAQ indicators into control dashboards would support management decisions, both in defining protocols to support resilience of the sector in a postpandemic world and in directing investments on the premises. This would also address guests’ pressing demands for a broader approach to cleanliness and safety and support their satisfaction and intention to return.

Originality/value

To the best of the authors’ knowledge, this is the first study developing a comprehensive framework to systematically address IAQ and its drivers, based on a standard and real-time monitoring. The framework has been applied across the longest period of monitoring for a hospitality premise thus far and over an entire hotel facility.

Details

International Journal of Contemporary Hospitality Management, vol. 35 no. 2
Type: Research Article
ISSN: 0959-6119

Keywords

Open Access
Article
Publication date: 16 February 2023

Danladi Chiroma Husaini, Kemberly Manzur and Jorge Medrano

This systematic review examined the emerging threat of indoor and outdoor pollutants to public health in Latin America and the Caribbean (LAC).

Abstract

Purpose

This systematic review examined the emerging threat of indoor and outdoor pollutants to public health in Latin America and the Caribbean (LAC).

Design/methodology/approach

Pollutants and pollution levels are becoming an increasing cause for concern within the LAC region, primarily because of the rapid increase in urbanization and the use of fossil fuels. The rise in indoor and outdoor air pollutants impacts public health, and there are limited regional studies on the impact of these pollutants and how they affect public health. A comprehensive literature search was conducted using Google Scholar, PubMed, Scopus, EBSCOhost, Web of Science and ScienceDirect databases. Significant search terms included “indoor air pollution,” “outdoor air pollution,” “pollution,” “Latin America,” “Central America,” “South America” and “Caribbean was used.” The systematic review utilized the Rayyan systematic software for uploading and sorting study references.

Findings

Database searches produced 1,674 results, of which, after using the inclusion–exclusion criteria and assessing for bias, 16 studies were included and used for the systematic review. These studies covered both indoor and outdoor pollution. Various indoor and outdoor air pollutants linked to low birth weight, asthma, cancer and DNA impairment were reported in this review. Even though only some intervention programs are available within the region to mitigate the harmful effects of pollution, these programs need to be robust and appropriately implemented, causing possible threats to public health. Significant gaps in the research were identified, especially in the Caribbean.

Research limitations/implications

Limitations of the study include limited available research done within LAC, with most of the research quantifying pollutants rather than addressing their impacts. Additionally, most studies focus on air pollution but neglect water and land pollution’s effects on public health. For this reason, the 16 studies included limited robustness of the review.

Originality/value

Although available studies quantifying pollution threats in LAC were identified in this review, research on the adverse impacts of pollution, especially concerning public health, is limited. LAC countries should explore making cities more energy-efficient, compact and green while improving the transportation sector by utilizing clean power generation. In order to properly lessen the effects of pollution on public health, more research needs to be done and implemented programs that are working need to be strengthened and expanded.

Details

Arab Gulf Journal of Scientific Research, vol. 42 no. 1
Type: Research Article
ISSN: 1985-9899

Keywords

Open Access
Article
Publication date: 29 December 2022

Eziaku Onyeizu Rasheed and James Olabode Bamidele Rotimi

Achieving an appropriate indoor environment quality (IEQ) is crucial to a green office environment. Whilst much research has been carried out across the globe on the ideal IEQ for…

Abstract

Purpose

Achieving an appropriate indoor environment quality (IEQ) is crucial to a green office environment. Whilst much research has been carried out across the globe on the ideal IEQ for green offices, little is known about which indoor environment New Zealand office workers prefer and regard as most appropriate. This study investigated New Zealand office workers' preference for a green environment.

Design/methodology/approach

Workers were conveniently selected for a questionnaire survey study from two major cities in the country – Wellington and Auckland. The perception of 149 workers was analysed and discussed based on the workers' demographics. The responses to each question were analysed based on the mean, standard deviation, frequency of responses and difference in opinion.

Findings

The results showed that workers' preferences for an ideal IEQ in green work environments depend largely on demographics. New Zealand office workers prefer work environments to have more fresh air and rely on mixed-mode ventilation and lighting systems. Also New Zealand office workers like to have better acoustic quality with less distraction and background noise. Regarding temperature, workers prefer workspaces to be neither cooler nor warmer. Unique to New Zealand workers, the workers prefer to have some (not complete) individual control over the IEQ in offices.

Research limitations/implications

This study was conducted in the summer season, which could have impacted the responses received. Also the sample size was limited to two major cities in the country. Further studies should be conducted in other regions and during different seasons.

Practical implications

This study provides the opportunity for more studies in this area of research and highlights significant findings worthy of critical investigations. The results of this study benefit various stakeholders, such as facilities managers and workplace designers, and support proactive response approaches to achieving building occupants' preferences for an ideal work environment.

Originality/value

This study is the first research in New Zealand to explore worker preferences of IEQ that is not limited to a particular building, expanding the body of knowledge on workers' perception of the ideal work environment in the country.

Details

Smart and Sustainable Built Environment, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2046-6099

Keywords

Open Access
Article
Publication date: 2 May 2019

Minyoung Kwon, Hilde Remøy and Andy Van Den Dobbelsteen

This paper highlights the importance of user satisfaction in office renovation. A user-focussed renovation approach can enhance user satisfaction in offices and their functional…

4693

Abstract

Purpose

This paper highlights the importance of user satisfaction in office renovation. A user-focussed renovation approach can enhance user satisfaction in offices and their functional quality while meeting energy performance goals. The purpose of this paper is to investigate users’ needs and the physical and psychological factors affecting user satisfaction, as input to office renovation projects.

Design/methodology/approach

The selected articles are collected from Scopus, ScienceDirect and Google Scholar. Searching was limited to the main key terms of office, work environment, and user satisfaction and comfort. The important factors were searched through empirical-based international literature mainly. Based hereupon, a guide will be developed for the analysis and evaluation of user satisfaction in office renovations.

Findings

From a comprehensive overview, the findings present ten main factors to increase user satisfaction in office renovation. These are associated with physical and psychological satisfaction and comfort. In addition, the influential factors were categorised into three levels based on needs theories to organise the hierarchy of priorities.

Practical implications

This research adds to the body of knowledge about which factors are important for user satisfaction, based on what previous research has found in that field. This is important to improve the sustainability in use.

Originality/value

User satisfaction is often studied through separate aspects: health and indoor climate vs functionality and productivity. This paper examines overall user satisfaction of workplaces by integrating the perspectives of physical and psychological conditions, and by providing insight into the priority of satisfaction factors.

Details

Property Management, vol. 37 no. 4
Type: Research Article
ISSN: 0263-7472

Keywords

1 – 10 of 141