Search results

1 – 10 of 16
Article
Publication date: 18 September 2019

Aitor Erkoreka, Ivan Flores-Abascal, Cesar Escudero, Koldo Martin, Jose Antonio Millan and Jose Maria Sala

Understanding the dynamic hygrothermal behavior of building elements is very important to ensure the optimal performance of buildings. The Laboratory for Quality Control in…

Abstract

Purpose

Understanding the dynamic hygrothermal behavior of building elements is very important to ensure the optimal performance of buildings. The Laboratory for Quality Control in Buildings of the Basque Government tested a flat roof designed by a construction company that developed a building to be constructed using prefabricated modules. This is a five to eight floor building with ventilated façade and a flat roof covered by gravel with the possibility of changing it to a green cover. The paper aims to discuss this issue.

Design/methodology/approach

The interest of this research was threefold. The first objective was to accurately test, under real dynamic weather conditions, the roof design in a PASLINK test cell to obtain the U-value and the thermal capacitance of the different roof layers, and of the roof as a whole, through the precise calibration of resistance-capacitance mathematical models of the roof. Based on the parameters and experimental information of these calibrated models, a second goal was to calibrate and validate a Wufi model of the roof.

Findings

This second calibrated model was then used to simulate the dynamic hygrothermal behavior of the roof, obtaining the roof’s hourly thermal demand per square meter for a whole year in different locations considered in the Spanish Building Code. These simulations also permitted the authors to study the risk of condensation and mold growth of the tested component under different climatic conditions.

Originality/value

The successful combination of the PASLINK method to calibrate the Wufi hygrothermal model is the main novelty of this research.

Details

International Journal of Building Pathology and Adaptation, vol. 38 no. 1
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 21 June 2019

Ivan Lee, Patrick Roppel, Mark Lawton and Prudence Ferreira

The purpose of this paper is to propose a methodology for evaluating the hygrothermal performance of framed wall assemblies based on design limits. This methodology allows…

Abstract

Purpose

The purpose of this paper is to propose a methodology for evaluating the hygrothermal performance of framed wall assemblies based on design limits. This methodology allows designers to evaluate wall assemblies based on their absolute performance rather than relative performance which is typically done for most hygrothermal analysis.

Design/methodology/approach

The approach in developing this methodology was to evaluate wall assemblies against three typical design loads (e.g. air leakage, construction moisture, rain penetration) and determine limits in minimum insulation ratio, maximum indoor humidity and maximum rain penetration rates. This analysis was performed at both the field area of the wall and at framing junctions such as window sills.

Findings

The findings in this paper shows example design limits for various wall assemblies in heating-dominated climates in North America. Design limits for wall assemblies with moisture membranes of different vapour permeance are provided for both the field area of the wall and at window sills. Discussions about the importance of 2D hygrothermal simulation and performance of vapour permeable sub-sill membranes are also provided.

Originality/value

This framework of hygrothermal analysis will enable designers to make better decisions when designing framed wall assemblies suitable to the local climate and interior specifications for their projects. It will also enable the development of a design tool that will allow designers to visually see the implications of certain design decisions and filter out designs that do not meet their design conditions.

Details

International Journal of Building Pathology and Adaptation, vol. 37 no. 4
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 30 April 2019

Philipp Kölsch

The surface temperature of the sub-roof beneath the ventilation layer and the tiles is one of the most important factors for the hygrothermal performance of pitched roofs. The air…

103

Abstract

Purpose

The surface temperature of the sub-roof beneath the ventilation layer and the tiles is one of the most important factors for the hygrothermal performance of pitched roofs. The air layer between tiles and sub-roof and the air exchange with the outdoor air influence the heat transfer and therefore affect the moisture level inside the roof construction. The paper aims to discuss these issues.

Design/methodology/approach

This paper provides the results of a research project performed at Fraunhofer-Institute for Building Physics, based on field test results. The investigations analyze the thermal behavior of different vented and ventilated roof constructions.

Findings

It was found that for a detailed model with roof cladding and ventilated air layer normally too many parameters are unknown. For that reason a simplified approach was set up, especially to consider the radiation exchange between the tiles and the underlay as well as the effects of the ventilation.

Originality/value

Now, effective surface transfer parameters can substitute both cladding and air layer in the simulation, while the approach still provides a high accordance with the measured values. The paper provides characteristic values for different roofing situations to simulate ventilated roofs by means of hygrothermal simulation in a simplified way.

Details

International Journal of Building Pathology and Adaptation, vol. 37 no. 4
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 11 April 2016

Sara Stingl de Freitas and Vasco Peixoto de Freitas

The purpose of this paper is to present a case study of cracks on external thermal insulation composite systems (ETICS) along the thermal insulation joints and the information…

Abstract

Purpose

The purpose of this paper is to present a case study of cracks on external thermal insulation composite systems (ETICS) along the thermal insulation joints and the information available on the building pathology catalogue – PATORREB. The aim is to establish the methodology to study the cause of the pathology observed on a building which is located on the interior of Portugal based on in situ probing together with the analysis of hygrothermal and mechanical behaviour.

Design/methodology/approach

An in situ analysis was performed to assess the causes. The hygrothermal dynamic behaviour of the wall was analysed with a numerical simulation advanced tool considering the climatic conditions, the characteristics of the thermal insulation plates as well as the support and finishing layer properties. Moreover, a qualitatively analysis of the mechanical behaviour, based on the bonding process, thermal insulation and exterior rendering properties was performed.

Findings

It was concluded that the insulation properties – thermal expansion coefficient and stiffness, the thermal expansion coefficient of the exterior rendering, together with adverse climatic conditions were critical for the appearance of cracks along the plate joints, particularly with spot bonding. The expansion and retraction stresses and the restrained movements of the components can result in bending moments, especially when the insulation material has a high stiffness value, which will create the crack on the rendering system.

Originality/value

A combination between a hygrothermal and mechanical analysis of an ETICS pathology concerning the appearance of cracks with a subsequent integration into a building pathology catalogue.

Details

Structural Survey, vol. 34 no. 1
Type: Research Article
ISSN: 0263-080X

Keywords

Article
Publication date: 4 October 2013

Mohammadjavad Mahdavinejad, Kavan Javanroodi and Leyli Hashemi Rafsanjani

The purpose of this paper is to investigate moisture problems and defects which have been caused by condensation in historic buildings. Emphasis has been put on finding…

Abstract

Purpose

The purpose of this paper is to investigate moisture problems and defects which have been caused by condensation in historic buildings. Emphasis has been put on finding condensation possibility on the external walls and inside temperature and humidity.

Design/methodology/approach

A third-part study including survey method to identify moisture problems and exhaustion, then determining indoor and outdoor temperature and relative humidity in a two-part survey within four days periods, and finally computer modeling and simulation to finding condensation possibility in the building walls by WUFI and THERM software.

Findings

Results indicated that the case study has serious defects and almost 7.5°C differences (Δt) and about 6 percent relative humidity differences (Δh) between indoor and outdoor temperature, and from analyzing computer simulations, condensation risk occurrence between wall layers is witnessed. Also this study shows that some climatic methods applied by traditional architects despite enhancing thermal comfort have caused damages and defects to the building envelope and structure. In this paper, the authors suggest a method to reduce condensation possibility by active ventilation for reducing temperature differences.

Originality/value

While there is a lock of technical researches and investigations about architectural heritages conservation, this study tries to perform a technical research and filling the gaps in this subject area.

Details

World Journal of Science, Technology and Sustainable Development, vol. 10 no. 4
Type: Research Article
ISSN: 2042-5945

Keywords

Article
Publication date: 28 March 2023

Ibrahim Neya, Daniel Yamegueu, Adamah Messan, Yezouma Coulibaly, Arnaud Louis Sountong-Noma Ouedraogo and Yawovi Mawuénya Xolali Dany Ayite

The stabilization of earthen blocks improves their mechanical strength and avoids adobe construction erosion due to rainwater. However, the stabilization affects the thermal…

Abstract

Purpose

The stabilization of earthen blocks improves their mechanical strength and avoids adobe construction erosion due to rainwater. However, the stabilization affects the thermal properties of the earthen blocks, and thus their capacity to provide adequate thermal comfort to occupants. This article examines the influence of cement and geopolymer binders on thermal comfort in compressed earthen buildings in hot and arid climates.

Design/methodology/approach

The test cell is on the building platform in Burkina Faso. The building is made of compressed earth blocks (CEB) consisting of laterite, water and binder. The thermal models of the building were implemented in EnergyPlus v9.0.1 software. Empirical validation is used to check whether the model used for the thermal dynamic simulation can reproduce with accuracy the thermal behavior in a real situation. The adaptive thermal comfort model of ASHRAE 55–2010 was used to assess thermal comfort in long-term hot and dry tropical conditions.

Findings

The results show that the CEB buildings remain hot despite the use of cement or geopolymer binder. Indeed, with both cement and geopolymer binders, on a daily basis, 19 h and 15 h are uncomfortable during, respectively, the hot and cold seasons. An increase of 1% in cement content raises the comfort hours by 9.2 h during the hot season and 11.7 h during the cold season. Hence, the comfort time varies linearly with the cement content in the building material. Moreover, there is no linear relationship between comfort time and geopolymer rate.

Research limitations/implications

Complementary work should also assess the influence of stabilization on building humidity levels. In fact, earthen materials are very sensitive to outdoor humidity and indoor humidity affects thermal comfort even if it is not taken into account in the ASHRAE adaptive thermal comfort model.

Practical implications

The present study will certainly contribute to a better valorization of clay potential in countries with similar climatic conditions.

Social implications

The use of geopolymer binder is a suitable ecological option to replace the cement binder. It is important to mention that nighttime comfort can be increased through passive strategies such as natural ventilation.

Originality/value

Most CEB material stabilization analyses including cement and geopolymer ones were mostly investigated at the laboratory scale and less at the building scale. Also, the influence of the binder rate on the thermal performance of buildings made of cement and geopolymer has not yet been assessed. This paper fills this gap of knowledge by assessing the impact of cement and geopolymer binder rates on the thermal comfort of CEB dwellings.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Article
Publication date: 7 October 2022

Césaire Hema, Philbert Nshimiyimana, Adamah Messan, Abdou Lawane and Geoffrey Van Moeseke

Appropriate thermal properties of walls can lead to the improvement of the indoor environment of buildings especially in countries with low energy availability such as Burkina…

Abstract

Purpose

Appropriate thermal properties of walls can lead to the improvement of the indoor environment of buildings especially in countries with low energy availability such as Burkina Faso. In order to benefit from these advantages, the thermal properties must be properly characterized. This paper investigates the impact of the design of single- and double-layer walls based on compressed Earth blocks (CEB) on the risk of indoor overheating.

Design/methodology/approach

First a building has been used as a tool to measure climate data. Then, a software program was used to define an accurate thermal model. Two indices were defined: weighted exceedance hour (WEH) related to the risk of overheating and cyclic thickness (ξ) related to the thermal properties of the walls. The aim is to define the appropriate values of ξ which minimized the WEH. The study also assesses the sensitivity of these thermal properties to occupancy profiles.

Findings

The results indicate the arrangements of the thermal properties that can promote comfortable environments. In single-layer wall buildings, ξ = 2.43 and ξ = 3.93 are the most suitable values to minimize WEH for the room occupied during the day and night, respectively. If a double-layer wall is used, ξ = 1.42 and CEB layer inside is the most suitable for the room occupied during the day, while ξ = 2.43 and CEB outside should be preferred in the case of a room with night occupancy profile.

Originality/value

The findings indicate that occupation patterns at room scale should be systematically considered when dealing with wall design in order to improve the thermal comfort.

Details

International Journal of Building Pathology and Adaptation, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2398-4708

Keywords

Open Access
Article
Publication date: 22 June 2022

Serena Summa, Alex Mircoli, Domenico Potena, Giulia Ulpiani, Claudia Diamantini and Costanzo Di Perna

Nearly 75% of EU buildings are not energy-efficient enough to meet the international climate goals, which triggers the need to develop sustainable construction techniques with…

1094

Abstract

Purpose

Nearly 75% of EU buildings are not energy-efficient enough to meet the international climate goals, which triggers the need to develop sustainable construction techniques with high degree of resilience against climate change. In this context, a promising construction technique is represented by ventilated façades (VFs). This paper aims to propose three different VFs and the authors define a novel machine learning-based approach to evaluate and predict their energy performance under different boundary conditions, without the need for expensive on-site experimentations

Design/methodology/approach

The approach is based on the use of machine learning algorithms for the evaluation of different VF configurations and allows for the prediction of the temperatures in the cavities and of the heat fluxes. The authors trained different regression algorithms and obtained low prediction errors, in particular for temperatures. The authors used such models to simulate the thermo-physical behavior of the VFs and determined the most energy-efficient design variant.

Findings

The authors found that regression trees allow for an accurate simulation of the thermal behavior of VFs. The authors also studied feature weights to determine the most relevant thermo-physical parameters. Finally, the authors determined the best design variant and the optimal air velocity in the cavity.

Originality/value

This study is unique in four main aspects: the thermo-dynamic analysis is performed under different thermal masses, positions of the cavity and geometries; the VFs are mated with a controlled ventilation system, used to parameterize the thermodynamic behavior under stepwise variations of the air inflow; temperatures and heat fluxes are predicted through machine learning models; the best configuration is determined through simulations, with no onerous in situ experimentations needed.

Details

Construction Innovation , vol. 24 no. 7
Type: Research Article
ISSN: 1471-4175

Keywords

Article
Publication date: 28 March 2024

Hatice Merve Yanardag Erdener and Ecem Edis

Living walls (LWs), vegetated walls with an integrated growth layer behind, are being increasingly incorporated in buildings. Examining plant characteristics’ comparative impacts…

Abstract

Purpose

Living walls (LWs), vegetated walls with an integrated growth layer behind, are being increasingly incorporated in buildings. Examining plant characteristics’ comparative impacts on LWs’ energy efficiency-related thermal behavior was aimed, considering that studies on their relative effects are limited. LWs of varying leaf albedo, leaf transmittance and leaf area index (LAI) were studied for Antalya, Turkey for typical days of four seasons.

Design/methodology/approach

Dynamic simulations run by Envi-met were used to assess the plant characteristics’ influence on seasonal and orientation-based heat fluxes. After model calibration, a sensitivity analysis was conducted through 112 simulations. The minimum, mean and maximum values were investigated for each plant characteristic. Energy need (regardless of orientation), temperature and heat flux results were compared among different scenarios, including a building without LW, to evaluate energy efficiency and variables’ impacts.

Findings

LWs reduced annual energy consumption in Antalya, despite increasing energy needs in winter. South and west facades were particularly advantageous for energy efficiency. The impacts of leaf albedo and transmittance were more significant (44–46%) than LAI (10%) in determining LWs’ effectiveness. The changes in plant characteristics changed the energy needs up to ca 1%.

Research limitations/implications

This study can potentially contribute to generating guiding principles for architects considering LW use in their designs in hot-humid climates.

Originality/value

The plant characteristics’ relative impacts on energy efficiency, which cannot be easily determined by experimental studies, were examined using parametric simulation results regarding three plant characteristics.

Details

Built Environment Project and Asset Management, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2044-124X

Keywords

Article
Publication date: 23 August 2013

Rajat Gupta, Matthew Gregg, Hu Du and Katie Williams

To critically compare three future weather year (FWY) downscaling approaches, based on the 2009 UK Climate Projections, used for climate change impact and adaptation analysis in…

Abstract

Purpose

To critically compare three future weather year (FWY) downscaling approaches, based on the 2009 UK Climate Projections, used for climate change impact and adaptation analysis in building simulation software.

Design/methodology/approach

The validity of these FWYs is assessed through dynamic building simulation modelling to project future overheating risk in typical English homes in 2050s and 2080s.

Findings

The modelling results show that the variation in overheating projections is far too significant to consider the tested FWY data sets equally suitable for the task.

Research and practical implications

It is recommended that future research should consider harmonisation of the downscaling approaches so as to generate a unified data set of FWYs to be used for a given location and climate projection. If FWY are to be used in practice, live projects will need viable and reliable FWY on which to base their adaptation decisions. The difference between the data sets tested could potentially lead to different adaptation priorities specifically with regard to time series and adaptation phasing through the life of a building.

Originality/value

The paper investigates the different results derived from FWY application to building simulation. The outcome and implications are important considerations for research and practice involved in FWY data use in building simulation intended for climate change adaptation modelling.

1 – 10 of 16