Search results
1 – 3 of 3Oluwamuyiwa Okunrounmu, Osama (Sam) Salem and George Hadjisophocleous
The fire resistance of timber structures is heavily dependent on the fire behaviour of the connections between its structural elements. The experimental study presented in this…
Abstract
Purpose
The fire resistance of timber structures is heavily dependent on the fire behaviour of the connections between its structural elements. The experimental study presented in this paper aimed to investigate the fire performance of glued-laminated timber beam connections reinforced perpendicular-to-wood grain with self-tapping screws (STS).
Design/methodology/approach
Two full-size fire experiments were conducted on glulam beam-end connections loaded in flexure bending. Two connection configurations, each utilizing four steel bolts arranged in two different patterns, were reinforced perpendicular to wood grain using STS. The bolt heads and nuts and the steel plate top and bottom edges were fire protected using wood plugs and strips, respectively. Each connection configuration was loaded to 100% of the ultimate design load of the weakest unreinforced configuration. The test assemblies were exposed to elevated temperatures that followed the CAN/ULC-S101 standard fire time–temperature curve.
Findings
The experimental results show that the influence of the STS was significant as it prevented the occurrence of wood splitting and row shear-out and as a result, increased the fire resistance time of the connections. The time to failure of both connection configurations exceeded the minimum fire resistance rating specified as 45 min for combustible construction in applicable building codes.
Originality/value
The experimental data show the effectiveness of a simple fire protection system (i.e. wood plugs and strips) along with the utilization of STS on the rotational behaviour, charring rate, fire resistance time and failure mode of the proposed hybrid mass timber beam-end connection configurations.
Details
Keywords
Milad Shabanian and Nicole Leo Braxtan
The purpose of this paper is to investigate the thermo-mechanical behavior of intermediate-size glued-laminated beam-to-girder assemblies connected with T-shaped slotted-in steel…
Abstract
Purpose
The purpose of this paper is to investigate the thermo-mechanical behavior of intermediate-size glued-laminated beam-to-girder assemblies connected with T-shaped slotted-in steel doweled connections at ambient temperature (AT), after and during non-standard fire exposure.
Design/methodology/approach
AT tests were performed using a universal testing machine (UTM) to evaluate the load-carrying capacity and failure modes of the assembly at room temperature. Post-fire-performance (PFP) tests were conducted to study the impact of 30-min and 60-min partial exposure to a non-standard fire on the residual strength of the assemblies. The assemblies were subject to fire in a custom-designed frame, then cooled and loaded to failure in the UTM. A fire-performance test was conducted to investigate the fire-resistance during non-standard fire exposure by simultaneously applying fire and mechanical load with the custom frame.
Findings
At AT, embedment failure of the dowels followed by brittle splitting failure were found to be the dominant failure modes in the beams. In the PFP tests, embedment failure and plastic bending of the dowels were the only observed failure modes. The residual strength of the assembly was reduced by 23.7% after 30-min and 47.8% after 60-min of fire exposure. Ductile embedment failure of the timber in contact with the dowels was the only failure mode observed during the fire-performance test, with the maximum rate of displacement at 57 min into the fire.
Originality/value
Data are presented for full-contact (no gap) connections in Glulam assemblies. PFP results are first to be published.
Details
Keywords
Milad Shabanian and Nicole Leo Braxtan
Thermomechanical behavior of intermediate-size beam-to-wall assemblies including Glulam-beams connected to cross-laminated timber (CLT) walls with T-shape steel doweled connections…
Abstract
Purpose
Thermomechanical behavior of intermediate-size beam-to-wall assemblies including Glulam-beams connected to cross-laminated timber (CLT) walls with T-shape steel doweled connections was investigated at ambient temperature (AT) and after and during non-standard fire exposure.
Design/methodology/approach
Three AT tests were conducted to evaluate the load-carrying capacity and failure modes of the assembly at room temperature. Two post-fire performance (PFP) tests were performed to study the impact of 30-min (PFP30) and 60-min (PFP60) partial exposure to a non-standard fire on the residual strength of the assemblies. The assemblies were exposed to fire in a custom-designed frame, then cooled and loaded to failure. A fire performance (FP) test was conducted to study the fire resistance (FR) during non-standard fire exposure by simultaneously applying fire and a mechanical load equal to 65% of the AT load carrying capacity.
Findings
At AT, embedment failure of the dowels followed by splitting failure at the Glulam-beam and tensile failure of the epoxy between the layers of CLT-walls were the dominant failure modes. In both PFP tests, the plastic bending of the dowels was the only observed failure mode. The residual strength of the assembly was reduced 14% after 30 min and 37% after 60 min of fire exposure. During the FP test, embedment failure of timber in contact with the dowels was the only major failure mode, with the maximum rate of displacement at 51 min into the fire exposure.
Originality/value
This is the first time that the thermomechanical performance of such an assembly with a full-contact connection is presented.
Details