11 – 20 of over 15000Kei Kimura, Takeshi Onogi, Naoya Yotsumoto and Fuminobu Ozaki
In this study, the effects of strain rate on the bending strength of full-scale wide-flange steel beams have been examined at elevated temperatures. Both full-scale loaded heating…
Abstract
Purpose
In this study, the effects of strain rate on the bending strength of full-scale wide-flange steel beams have been examined at elevated temperatures. Both full-scale loaded heating tests under steady-state conditions and in-plane numerical analysis using a beam element have been employed.
Design/methodology/approach
The load–deformation relationships in 385 N/mm2-class steel beam specimens was examined using steady-state tests at two loading rate values (0.05 and 1.00 kN/s) and at two constant member temperatures (600 and 700 °C). Furthermore, the stress–strain relationships considering the strain rate effects were proposed based on tensile coupon test results under various strain rate values. The in-plane elastoplastic numerical analysis was conducted considering the strain rate effect.
Findings
The experimental test results of the full-scale steel beam specimens confirmed that the bending strength increased with increase in strain rate. In addition, the analytical results agreed relatively well with the test results, and both strain and strain rate behaviours of a heated steel member, which were difficult to evaluate from the test results, could be quantified numerically.
Originality/value
The novelty of this study is the quantification of the strain rate effect on the bending strength of steel beams at elevated temperatures. The results clarify that the load–deformation relationship of steel beams could be evaluated by using in-plane analysis using the tensile coupon test results. The numerical simulation method can increase the accuracy of evaluation of the actual behaviour of steel members in case of fire.
Details
Keywords
Bernhard A. Schrefler, Carmelo E. Majorana, Gabriel A. Khoury and Dariusz Gawin
This paper presents the physical, mathematical and numerical models forming the main structure of the numerical analysis of the thermal, hydral and mechanical behaviour of normal…
Abstract
This paper presents the physical, mathematical and numerical models forming the main structure of the numerical analysis of the thermal, hydral and mechanical behaviour of normal, high‐performance concrete (HPC) and ultra‐high performance concrete (UHPC) structures subjected to heating. A fully coupled non‐linear formulation is designed to predict the behaviour, and potential for spalling, of heated concrete structures for fire and nuclear reactor applications. The physical model is described in more detail, with emphasis being placed upon the real processes occurring in concrete during heating based on tests carried out in several major laboratories around Europe as part of the wider high temperature concrete (HITECO) research programme. A number of experimental and modelling advances are presented in this paper. The stress‐strain behaviour of concrete in direct tension, determined experimentally, is input into the model. The hitherto unknown micro‐structural, hydral and mechanical behaviour of HPC/UHPC were determined experimentally and the information is also built into the model. Two examples of computer simulations concerning experimental validation of the model, i.e. temperature and gas pressure development in a radiatively heated HPC wall and hydro‐thermal and mechanical (damage) performance of a square HPC column during fire, are presented and discussed in the context of full scale fire tests done within the HITECO research programme.
Details
Keywords
The purpose of this paper is to describe how, in the recent attempts to stimulate alternative energy sources for heating and cooling of buildings, emphasis has been put on…
Abstract
Purpose
The purpose of this paper is to describe how, in the recent attempts to stimulate alternative energy sources for heating and cooling of buildings, emphasis has been put on utilisation of the ambient energy from ground source heat pump systems (GSHPs) and other renewable energy sources.
Design/methodology/approach
Exploitation of renewable energy sources and particularly ground heat in buildings can significantly contribute towards reducing dependency on fossil fuels. This paper highlights the potential energy saving that could be achieved through use of ground energy source. It also focuses on the optimisation and improvement of the operation conditions of the heat cycles and performances of the direct expansion (DX) GSHP.
Findings
It is concluded that the direct expansion of GSHP are extendable to more comprehensive applications combined with the ground heat exchanger in foundation piles and the seasonal thermal energy storage from solar thermal collectors.
Originality/value
The paper highlights the energy problem and the possible saving that can be achieved through the use of the GSHP systems and discusses the principle of the ground source energy, varieties of GSHPs, and various developments.
Details
Keywords
During the design of the Atlas I.C.B.M. it was considered necessary to conduct full‐scale combined structural loading and aerodynamic heating tests for the purpose of proving the…
Abstract
During the design of the Atlas I.C.B.M. it was considered necessary to conduct full‐scale combined structural loading and aerodynamic heating tests for the purpose of proving the ability of the nose adaptor and thrust barrel to withstand the combined effects of load and temperature. The following items were required to perform the tests: heating elements to radiate 450 sq. ft. of specimen area at a maximum rate of 10,000 B.T.U/sq. ft./hr., 1,500 KVA at 44 volts for six mins., controller, three variable pressure regulators for programming 3,000 lb./sq. in. hydraulic pressure to the loading cylinders, six‐channel programmer for varying heating and loading rates, a method for relating the capabilities of the equipment to the desired heat and load curves. Descriptions arc given of the heating equipment, heat controller, load controller, programmer, preliminary heat tests, preliminary load tests and test programmes as used by the Systems Test Laboratory of Convair‐Astronautics. As experience was gained by testing the need for preliminary tests was greatly reduced. The method described continues to be a valuable tool for performing full‐scale missile structural tests.
W.G. Heath and B.O. Heath
BEFORE a detailed consideration of internal stresses may be made, it is necessary to define external loadings which are possibly critical. This involves the consideration of…
Abstract
BEFORE a detailed consideration of internal stresses may be made, it is necessary to define external loadings which are possibly critical. This involves the consideration of manoeuvres throughout the altitude range of the aeroplane, to a severity fixed by aerodynamic or specification values of speed and normal acceleration.
Hemanth Kumar Chinthapalli and Anil Agarwal
Earthquake tremors not only increase the chances of fire ignition but also hinder the fire-fighting efforts due to the damage to the lifelines of a city. Most of the international…
Abstract
Purpose
Earthquake tremors not only increase the chances of fire ignition but also hinder the fire-fighting efforts due to the damage to the lifelines of a city. Most of the international codes have independent recommendations for structural safety against earthquake and fire. However, the possibility of a multi-hazard event, such as fire following an earthquake is seldom addressed.
Design/methodology/approach
This paper presents an experimental study of Reinforced Concrete (RC) columns in post-earthquake fire (PEF) conditions. An experimental approach is proposed that allows the testing of a column instead of a full structural frame. This approach allows us to control the loading and boundary conditions individually and facilitates the testing under a variety of these conditions. Also, it allows the structure to be tested until failure. The role of parameters, such as earthquake intensity, axial load ratio and the ductile detailing of the column on the earthquake damage and subsequently the fire performance of the structure, is studied in this research. Six RC column specimens are tested under a sequence of quasi-static earthquake loading, followed by combined fire and axial compression loading conditions.
Findings
The experiment results indicate that ductile detailed columns subjected to 4% or less lateral drift did not lose significant load-carrying capacity in fire conditions. A lateral drift of 6% caused significant damage to the columns and reduced the load-carrying capacity in fire conditions. The level of the axial load acting on the column at the time of earthquake loading was found to have a very significant effect on the extent of damage and reduction in column load capacity in fire conditions. The columns that were not detailed for a ductile behavior observed a more significant reduction in axial load carrying capacity in fire conditions.
Research limitations/implications
This study is limited to columns of 230 mm size due to the limitations of the test setup. The applicability of these findings to larger column sections needs to be verified by developing a numerical analysis methodology and simulating other post-earthquake-fire tests available in the literature.
Originality/value
The experimental procedure proposed in this paper offers an alternative to the testing of a complete structural frame system for PEF behavior. In addition to the ease of conducting the tests, the procedure also allows much better control over the heating, structural loading and boundary conditions.
Details
Keywords
While calculating internal forces of a structure resulting from temperature it is necessary to know thermal conduction and what goes hand in hand to determine temperature…
Abstract
While calculating internal forces of a structure resulting from temperature it is necessary to know thermal conduction and what goes hand in hand to determine temperature distribution at various points of the analysed structures. Finite strip method (FSM) is very suitable for the analysis of thermal conduction, heating, heat and temperature distribution in engineering structures, especially rectangular of identical edge conditions. The paper presents several examples of FSM application for the analysis of conduction and heat and temperature distribution for various types of engineering structures which can appear, among others, while welding several joined elements with welds made at specified speed as linear and point welds. Bars, shields, square and rectangular plates, steel orthotropic plates, steel and combined girders (steel‐concrete), box girders subject to various loads connected with heat and temperature (loaded with temperature, non‐uniformly heated surface). The obtained results may be useful in engineering practice for determining actual temperature and load capacity in individual elements of the construction.
C. Kahanji, F. Ali and A. Nadjai
The purpose of the study was to investigate the spalling phenomenon in ultra-high performance fibre reinforced concrete (UHPFRC) beams on exposure to a standard fire curve (ISO…
Abstract
Purpose
The purpose of the study was to investigate the spalling phenomenon in ultra-high performance fibre reinforced concrete (UHPFRC) beams on exposure to a standard fire curve (ISO 834) under a sustained load.
Design/methodology/approach
The variables in this study were steel fibre dosage, polypropylene (PP) fibres and loading levels. The research investigated seven beams – three of which contained steel fibres with 2 vol.%, another three had steel fibres with 4 vol.% dosage and the seventh beam had a combination of steel fibres (2 vol.%) and PP fibres (4 kg/m3). The beams were tested for 1 h under three loading levels (20, 40 and 60 per cent) based on the ambient temperature ultimate flexural strength of the beam.
Findings
Spalling was affected by the loading levels; it exacerbated under the load level of 40 per cent, whereas under the 60 per cent load level, significantly less spalling was recorded. Under similar loading conditions, the beams containing steel fibres with a dosage of 4 vol.% spalled less than the beams with fibre contents of 2 vol.%. This was attributed to the additional tensile strength provided by the excess steel fibres. The presence of PP fibres eliminated spalling completely.
Originality/value
There is insufficient research into the performance of UHPFRC beams at elevated temperature, as most studies have largely focussed on columns, slabs and smaller elements such as cubes and cylinders. This study provides invaluable information and insights of the influence of parameters such as steel fibre dosage, PP fibres, loading levels on the spalling behaviour and fire endurance of UHPFRC beams.
Details
Keywords
Abdulrahman M. Almufarrej and Tohid Erfani
The two main contributing factors that control the overall buildings’ energy performance are the heating ventilation and air conditioning (HVAC) system and the envelope design…
Abstract
Purpose
The two main contributing factors that control the overall buildings’ energy performance are the heating ventilation and air conditioning (HVAC) system and the envelope design. Environmental design guidelines that consider these two factors aim to lower energy consumption. However, they are regional and climate-sensitive. This study aims to investigate how three main buildings’ envelope design variables (orientation, compactness and window to wall ratio) impact the overall building’s energy consumption within Kuwait’s regional and climate conditions.
Design/methodology/approach
This study simulate the energy consumption of typically shaped buildings by varying their geometry between a square to a rectangular floor plan. This study analyse the associated energy usage and provide early-stage envelope design guidance specific to the country’s conditions, to make informed decisions towards environmentally conscious buildings.
Findings
The analysed envelope variables have the potential to reduce energy consumption by 40%, and the possibility to reduce HVAC system capacity by 30%. In contrast to the general guidance in literature and standards, the simulation results demonstrate that less compact building forms perform on occasions better than the most compact ones.
Originality/value
The objective of this paper is to quantify the energy consumption rates for buildings located within the Arabian Peninsula, an under-studied region with potentially high interest considering three main envelope design variables. The buildings’ yearly energy consumption patterns are unique and suggest different envelope design considerations, compared to other regions with different climate conditions. This emphasises the importance of regional guidelines for the different factors associated with energy and buildings’ environmental performance.
Details
Keywords
Kristi L. Selden and Amit H. Varma
The purpose of this study was to develop a three-dimensional (3D) finite element modeling (FEM) technique using the commercially available program ABAQUS to predict the thermal…
Abstract
Purpose
The purpose of this study was to develop a three-dimensional (3D) finite element modeling (FEM) technique using the commercially available program ABAQUS to predict the thermal and structural behavior of composite beams under fire loading.
Design/methodology/approach
The model was benchmarked using experimental test data, and it accounts for temperature-dependent material properties, force-slip-temperature relationship for the shear studs and concrete cracking.
Findings
It was determined that composite beams can be modeled with this sequentially coupled thermal-structural 3D FEM to predict the displacement versus bottom flange temperature response and associated composite beam failure modes, including compression failure in the concrete slab, runaway deflection because of yielding of the steel beam or fracture of the shear studs.
Originality/value
The Eurocode stress-strain-temperature (σ-ε-T) material model for structural steel and concrete conservatively predict the composite beam deflections at temperatures above 500°C. Models that use the National Institute of Standards and Technology (NIST) stress-strain-temperature (σ-ε-T) material model more closely match the measured deflection response, as compared to the results using the Eurocode model. However, in some cases, the NIST model underestimates the composite beam deflections at temperatures above 500°C.
Details