Search results

1 – 3 of 3
Article
Publication date: 13 June 2020

Sahar Ghobadi and Hadi Shahir

The purpose of this paper is to study the distribution of active earth pressure in retaining walls with narrow cohesion less backfill considering arching effects.

Abstract

Purpose

The purpose of this paper is to study the distribution of active earth pressure in retaining walls with narrow cohesion less backfill considering arching effects.

Design/methodology/approach

To this end, the approach of principal stresses rotation was used to consider the arching effects.

Findings

According to the presented formulation, the active soil pressure distribution is nonlinear with zero value at the wall base. The proposed formulation implies that by increasing the frictional forces at both sides of the backfill, the arching effect is increased and so, the lateral earth pressure on the retaining wall is decreased. Also, by narrowing the backfill space, the lateral earth pressure is extremely decreased.

Originality/value

A comprehensive analytical solution for the active earth pressure of narrow backfills is presented, such that the effects of the surcharge and the characteristics of the stable back surface are considered. The magnitude and height of the application of lateral active force are also derived.

Details

Engineering Computations, vol. 38 no. 1
Type: Research Article
ISSN: 0264-4401

Keywords

Article
Publication date: 3 February 2020

Hamed Arefizadeh and Hadi Shahir

Anchorage with concrete bearing pad is commonly used in Iran for stabilization of excavations because of the ease of construction, less costs and less time consumption than the…

Abstract

Purpose

Anchorage with concrete bearing pad is commonly used in Iran for stabilization of excavations because of the ease of construction, less costs and less time consumption than the soldier pile method. In this method, a wall facing which includes the concrete bearing pads at the location of the anchors and a shotcrete layer between the bearing pads is constructed parallel to the excavation operation similar to the nailing method.

Design/methodology/approach

In this paper, using the finite element software Abaqus, a three-dimensional model of the above-mentioned type of wall is constructed, and the effect of spacing and size of bearing pads on the wall behavior is discussed.

Findings

According to the obtained results, the size of the concrete bearing pads has little effect on wall deformations, but the internal forces and bending moments developed in the shotcrete layer between the bearing pads are greatly influenced by the bearing pads dimensions and spacing.

Originality/value

Owing to the discrete elements of the wall facing, the behavior of this system is completely three-dimensional.

Details

Journal of Engineering, Design and Technology , vol. 18 no. 6
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 21 May 2020

Seyyed Pouya Alavinezhad and Hadi Shahir

The purpose of this study is to present a diagram for the lateral earth pressure of c–φ soils exerted on anchored walls in presence of surcharge.

Abstract

Purpose

The purpose of this study is to present a diagram for the lateral earth pressure of c–φ soils exerted on anchored walls in presence of surcharge.

Design/methodology/approach

To this end, two-dimensional plane strain modeling of anchored wall was carried out in Plaxis software. To validate the numerical model, two excavations with different specifications were simulated and the model results were compared with the available results. Subsequently, a parametric analysis was done and based on its results, a diagram was proposed for the lateral earth pressure of c–φ soils including the surcharge effects.

Findings

The proposed diagram without the surcharge and cohesion effects is a trapezoidal with zero value at the ground surface that is linearly approaching the apparent earth pressure of sand according to Terzaghi and Peck (1967) at 0.1H (H: wall height). The surcharge and cohesion effects at the ground level is 4 Ka*q and 0, respectively, and below 0.1H, they are treated as the same way for lateral earth pressure of a retaining wall. It should be emphasized that the apparent pressure diagram for design does not resemble the real distribution of earth pressure against the wall and it is for calculating the values of the anchors loads.

Originality/value

The available diagrams to determine the earth pressure exerted on the anchored walls are related to sandy or clayey soils and do not take the presence of surcharge into account. Thus, the proposed diagram is quite original and different from the previous ones.

Details

World Journal of Engineering, vol. 17 no. 4
Type: Research Article
ISSN: 1708-5284

Keywords

Access

Year

Content type

Article (3)
1 – 3 of 3