Open Access
Article
Publication date: 21 December 2022

Milad Shabanian and Nicole Leo Braxtan

3-ply cross-laminated timber (CLT) is used to investigate the thermo-mechanical performance of intermediate-size assemblies comprised of T-shaped welded slotted-in steel doweled…

Abstract

Purpose

3-ply cross-laminated timber (CLT) is used to investigate the thermo-mechanical performance of intermediate-size assemblies comprised of T-shaped welded slotted-in steel doweled connections and CLT beams at ambient temperature (AT), after and during non-standard fire exposure.

Design/methodology/approach

The first set of experiments was performed as a benchmark to find the load-carrying capacity of the assembly and investigate the failure modes at AT. The post-fire performance (PFP) test was performed to investigate the residual strength of the assembly after 30-min exposure to a non-standard fire. The fire-performance (FP) test was conducted to investigate the thermo-mechanical behavior of the loaded assembly during non-standard fire exposure. In this case, the assembly was loaded to 67% of AT load-carrying capacity and partially exposed to a non-standard fire for 75 min.

Findings

Embedment failure and plastic deformation of the dowels in the beam were the dominant failure modes at AT. The load-carrying capacity of the assembly was reduced to 45% of the ambient capacity after 30 min of fire exposure. Plastic bending of the dowels was the principal failure mode, with row shear in the mid-layer of the CLT beam and tear-out failure of the header sides also observed. During the FP test, ductile embedment failure of the timber in contact with the dowels was the major failure mode at elevated temperature.

Originality/value

This paper presents for the first time the thermo-mechanical performance of CLT beam-to-girder connections at three different thermal conditions. For this purpose, the outside layers of the CLT beams were aligned horizontally.

Highlights

  1. Load-carrying capacity and failure modes of CLT beam-to-girder assembly with T-shaped steel doweled connections at ambient temperature presented.

  2. Residual strength and failure modes of the assembly after 30-min partially exposure to the non-standard fire provided throughout the post-fire performance test.

  3. Fire resistance of the assembly partially exposed to the non-standard fire highlighted.

Load-carrying capacity and failure modes of CLT beam-to-girder assembly with T-shaped steel doweled connections at ambient temperature presented.

Residual strength and failure modes of the assembly after 30-min partially exposure to the non-standard fire provided throughout the post-fire performance test.

Fire resistance of the assembly partially exposed to the non-standard fire highlighted.

Article
Publication date: 20 January 2022

Milad Shabanian and Nicole Leo Braxtan

The purpose of this paper is to investigate the thermo-mechanical behavior of intermediate-size glued-laminated beam-to-girder assemblies connected with T-shaped slotted-in steel…

Abstract

Purpose

The purpose of this paper is to investigate the thermo-mechanical behavior of intermediate-size glued-laminated beam-to-girder assemblies connected with T-shaped slotted-in steel doweled connections at ambient temperature (AT), after and during non-standard fire exposure.

Design/methodology/approach

AT tests were performed using a universal testing machine (UTM) to evaluate the load-carrying capacity and failure modes of the assembly at room temperature. Post-fire-performance (PFP) tests were conducted to study the impact of 30-min and 60-min partial exposure to a non-standard fire on the residual strength of the assemblies. The assemblies were subject to fire in a custom-designed frame, then cooled and loaded to failure in the UTM. A fire-performance test was conducted to investigate the fire-resistance during non-standard fire exposure by simultaneously applying fire and mechanical load with the custom frame.

Findings

At AT, embedment failure of the dowels followed by brittle splitting failure were found to be the dominant failure modes in the beams. In the PFP tests, embedment failure and plastic bending of the dowels were the only observed failure modes. The residual strength of the assembly was reduced by 23.7% after 30-min and 47.8% after 60-min of fire exposure. Ductile embedment failure of the timber in contact with the dowels was the only failure mode observed during the fire-performance test, with the maximum rate of displacement at 57 min into the fire.

Originality/value

Data are presented for full-contact (no gap) connections in Glulam assemblies. PFP results are first to be published.

Open Access
Article
Publication date: 7 December 2022

Milad Shabanian and Nicole Leo Braxtan

Thermomechanical behavior of intermediate-size beam-to-wall assemblies including Glulam-beams connected to cross-laminated timber (CLT) walls with T-shape steel doweled…

Abstract

Purpose

Thermomechanical behavior of intermediate-size beam-to-wall assemblies including Glulam-beams connected to cross-laminated timber (CLT) walls with T-shape steel doweled connections was investigated at ambient temperature (AT) and after and during non-standard fire exposure.

Design/methodology/approach

Three AT tests were conducted to evaluate the load-carrying capacity and failure modes of the assembly at room temperature. Two post-fire performance (PFP) tests were performed to study the impact of 30-min (PFP30) and 60-min (PFP60) partial exposure to a non-standard fire on the residual strength of the assemblies. The assemblies were exposed to fire in a custom-designed frame, then cooled and loaded to failure. A fire performance (FP) test was conducted to study the fire resistance (FR) during non-standard fire exposure by simultaneously applying fire and a mechanical load equal to 65% of the AT load carrying capacity.

Findings

At AT, embedment failure of the dowels followed by splitting failure at the Glulam-beam and tensile failure of the epoxy between the layers of CLT-walls were the dominant failure modes. In both PFP tests, the plastic bending of the dowels was the only observed failure mode. The residual strength of the assembly was reduced 14% after 30 min and 37% after 60 min of fire exposure. During the FP test, embedment failure of timber in contact with the dowels was the only major failure mode, with the maximum rate of displacement at 51 min into the fire exposure.

Originality/value

This is the first time that the thermomechanical performance of such an assembly with a full-contact connection is presented.

Details

Journal of Structural Fire Engineering, vol. 14 no. 3
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 11 September 2023

Robyn Lee, Faye Horsley and Annette McKeown

Previous qualitative research by Horsley (2020) and Lee (2019) highlighted the importance of self-concept (SC) in understanding fire use. This study, therefore, aims to further…

Abstract

Purpose

Previous qualitative research by Horsley (2020) and Lee (2019) highlighted the importance of self-concept (SC) in understanding fire use. This study, therefore, aims to further investigate the relevance of SC in non-criminalised fire use, with a view towards informing early interventions for firesetting prevention.

Design/methodology/approach

In this preliminary study, ten participants engaging in extensive, non-criminalised fire use were interviewed about their fire-related experiences and how this relates to SC. This was analysed using techniques informed by the grounded theory.

Findings

Three core categories were identified: control, identity and self-esteem, which provide a preliminary framework for understanding how SC and non-criminalised fire use are inter-related. The core categories relate to the study aim because they are conceptualised as three elements of SC, which are strengthened through interactions with fire. The mechanisms through which the categories relate to fire use and SC are discussed.

Practical implications

Forensic implications are discussed regarding early intervention and prevention. The authors argue that knowledge of non-criminalised fire use could provide a valuable blueprint for healthy fire use and, thus, feed into treatment and intervention. Given that previous research has highlighted the importance of SC in relation to how and why people interact with fire, the authors suggest that it should be given greater emphasis in clinical work with those thought to be at risk of firesetting.

Originality/value

To date, firesetting research has focused primarily on criminalised acts, i.e. arson. This paper adopts a different approach and explores how and why people engage with fire in healthy and adaptive ways.