Search results

1 – 10 of 738
Article
Publication date: 28 April 2023

Daas Samia and Innal Fares

This study aims to improve the reliability of emergency safety barriers by using the subjective safety analysis based on evidential reasoning theory in order to develop on a…

Abstract

Purpose

This study aims to improve the reliability of emergency safety barriers by using the subjective safety analysis based on evidential reasoning theory in order to develop on a framework for optimizing the reliability of emergency safety barriers.

Design/methodology/approach

The emergency event tree analysis is combined with an interval type-2 fuzzy-set and analytic hierarchy process (AHP) method. In order to the quantitative data is not available, this study based on interval type2 fuzzy set theory, trapezoidal fuzzy numbers describe the expert's imprecise uncertainty about the fuzzy failure probability of emergency safety barriers related to the liquefied petroleum gas storage prevent. Fuzzy fault tree analysis and fuzzy ordered weighted average aggregation are used to address uncertainties in emergency safety barrier reliability assessment. In addition, a critical analysis and some corrective actions are suggested to identify weak points in emergency safety barriers. Therefore, a framework decisions are proposed to optimize and improve safety barrier reliability. Decision-making in this framework uses evidential reasoning theory to identify corrective actions that can optimize reliability based on subjective safety analysis.

Findings

A real case study of a liquefied petroleum gas storage in Algeria is presented to demonstrate the effectiveness of the proposed methodology. The results show that the proposed methodology provides the possibility to evaluate the values of the fuzzy failure probability of emergency safety barriers. In addition, the fuzzy failure probabilities using the fuzzy type-2 AHP method are the most reliable and accurate. As a result, the improved fault tree analysis can estimate uncertain expert opinion weights, identify and evaluate failure probability values for critical basic event. Therefore, suggestions for corrective measures to reduce the failure probability of the fire-fighting system are provided. The obtained results show that of the ten proposed corrective actions, the corrective action “use of periodic maintenance tests” prioritizes reliability, optimization and improvement of safety procedures.

Research limitations/implications

This study helps to determine the safest and most reliable corrective measures to improve the reliability of safety barriers. In addition, it also helps to protect people inside and outside the company from all kinds of major industrial accidents. Among the limitations of this study is that the cost of corrective actions is not taken into account.

Originality/value

Our contribution is to propose an integrated approach that uses interval type-2 fuzzy sets and AHP method and emergency event tree analysis to handle uncertainty in the failure probability assessment of emergency safety barriers. In addition, the integration of fault tree analysis and fuzzy ordered averaging aggregation helps to improve the reliability of the fire-fighting system and optimize the corrective actions that can improve the safety practices in liquefied petroleum gas storage tanks.

Details

International Journal of Quality & Reliability Management, vol. 41 no. 1
Type: Research Article
ISSN: 0265-671X

Keywords

Article
Publication date: 24 October 2023

Mohammad A. Hassanain and Zayed A. Albugami

Community centers play a socio-economic and urban role of combining different communal necessities, that serve inhabitants, at different neighborhoods in cities. Their role…

Abstract

Purpose

Community centers play a socio-economic and urban role of combining different communal necessities, that serve inhabitants, at different neighborhoods in cities. Their role emerged in importance as being a hub for improving and customizing quality of life experiences of the public. This research presents a code-based risk assessment tool for evaluating fire safety measures that can be adapted in the context of community centers. It also provides an exemplary case study to demonstrate its application.

Design/methodology/approach

The study identified the factors that render community centers as a high-risk type of facilities in fire events. Various fire codes and standards were reviewed to describe the relevant fire safety measures. A code-based fire risk assessment tool was developed and implemented, through a case study. A set of recommendations were developed to improve the fire safety conditions of the case study facility.

Findings

Several violations to fire safety were identified in the case study building. The findings led to identifying a set of recommendations to improve its fire safety conditions.

Practical implications

This research introduced a systematic approach to raise awareness about fire incidences and consequences in community centers, and provides facilities managers with a tool, to assess compliance based on international fire code requirements.

Originality/value

In fire events, community centers are considered as high-risk facilities that may lead to significant losses of human lives and damages to assets. It is significant to study the causes of fire, for ensuring effective prevention and safe operations.

Details

International Journal of Emergency Services, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2047-0894

Keywords

Article
Publication date: 12 January 2024

Jingqi Zhang, Shaohua Jiang and Xiaomin Qi

The purpose of this paper is to conduct a comprehensive study on building, fire and evacuation, so as to effectively improve the efficiency of building fire evacuation and the…

Abstract

Purpose

The purpose of this paper is to conduct a comprehensive study on building, fire and evacuation, so as to effectively improve the efficiency of building fire evacuation and the management level of fire evacuation site. Make up for the difficulties of BIM technology in effectively connecting building information and fire data.

Design/methodology/approach

First, this paper establishes a fire model and an evacuation model based on BIM information. Then, the safety index (SI) is introduced as a comprehensive index, and the IRI is established by integrating the SI function to evaluate the safety of evacuation routes. Based on these two indices, the IRI-based fire evacuation model is established.

Findings

This study offers an Improved Risk Index (IRI)-based fire evacuation model, which may achieve effective evacuation in fire scenes. And the model is verified by taking the fire evacuation of a shopping center building as an example.

Originality/value

This paper proposes a fire evacuation principle based on IRI, so that the relevant personnel can comprehensively consider the fire factors and evacuation factors to achieve the optimization of building design, thereby improving the fire safety of buildings.

Details

Engineering, Construction and Architectural Management, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0969-9988

Keywords

Article
Publication date: 30 November 2023

Mark Pim-Wusu, Eric Kwame Simpeh and Jeremiah N-Nanajeri Simberi

Fire is the fundamental element of most people’s lives, and when not controlled, the same fire can lead to several catastrophes in homes, offices, schools, lives and other public…

Abstract

Purpose

Fire is the fundamental element of most people’s lives, and when not controlled, the same fire can lead to several catastrophes in homes, offices, schools, lives and other public places with severe repercussions. Hence, this study aims to examine the adequacy and extent of the application of fire suppression systems in residential and commercial property in Ghana.

Design/methodology/approach

This study adopts a sequential mixed-mode design comprising quantitative and qualitative research strategies to analyse factors to produce findings. The target population for this study includes shop occupiers, end users of office buildings, and residents in the Accra Central of Ghana. Systematic random sampling was used for the quantitative research, and a sample size of 385 was obtained using a multi-stage and cluster sampling method. A structured survey and semi-structured interviews were used to collect the primary data. The quantitative data were analysed using descriptive and inferential statistics, whereas the qualitative data were analysed using content analysis.

Findings

From an empirical literature review and the analysis, the three main factors contributing to fire breakouts are equipment malfunction, improper use of heat sources and human mistakes. According to the respondents, fire suppression systems were also inadequate, as most of the suppression systems prescribed in the building code were unavailable. Regarding the ability to manually operate fire suppression systems, most property occupiers stated that they are generally unaware of these suppression systems.

Practical implications

This study will aid policymakers in developing interventions for fire safety enforcement by ensuring that fire safety regulations are consistently followed by design team members and property developers, resulting in a positive effect on public building structures performing their required functions. It is also critical to provide end users with education and training on how to operate the fire suppression system as well as effective handling of firefighting installations in the event of a fire.

Originality/value

The findings of this investigation contribute to knowledge and comprehension of the effect of fire suppression systems on building users and may serve as a precursor to the development of a “As Built” certification system for ascertaining the adequacy of fire suppression systems for new and existing residential and commercial property.

Details

Journal of Engineering, Design and Technology , vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 1726-0531

Keywords

Article
Publication date: 8 November 2023

Marcus Achenbach and Guido Morgenthal

The design check regarding the fire resistance of concrete slabs can be easily performed using tabulated values. These tables are based on experimental results, but the level of…

Abstract

Purpose

The design check regarding the fire resistance of concrete slabs can be easily performed using tabulated values. These tables are based on experimental results, but the level of safety, which is obtained by this approach, is not known. On the other hand, performance-based methods are more accepted, but require a target reliability as performance criterion. Hence, there is a need for calibration of the performance-based methods using the results of the “traditional” descriptive approach.

Design/methodology/approach

The calibration is performed for a single span concrete slab, where the axis distance of the reinforcement is chosen according to Eurocode 2 for a defined fire rating. A “standard” compartment is selected to cover typical fields of application. The opening factor is considered as parameter to obtain the maximum peak temperatures in the compartment. A Monte Carlo simulation, in combination with a response surface method, is set up to calculate the probabilities of failure.

Findings

The results indicate that the calculated reliability index for a standard is within the range, which has been used for the derivation of safety and combination factors in the Eurocodes. It can be observed that members designed for a fire rating R90 have a significant increase in the structural safety for natural fires compared to a design for a fire rating R30.

Originality/value

The level of safety, which is obtained by a design based on tabulated values, is quantified for concrete slabs. The results are a necessary input for the calibration of performance-based methods and could stimulate discussions among scientists and building authorities.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 6 February 2024

Andrea Lucherini and Donatella de Silva

Intumescent coatings are nowadays a dominant passive system used to protect structural materials in case of fire. Due to their reactive swelling behaviour, intumescent coatings…

Abstract

Purpose

Intumescent coatings are nowadays a dominant passive system used to protect structural materials in case of fire. Due to their reactive swelling behaviour, intumescent coatings are particularly complex materials to be modelled and predicted, which can be extremely useful especially for performance-based fire safety designs. In addition, many parameters influence their performance, and this challenges the definition and quantification of their material properties. Several approaches and models of various complexities are proposed in the literature, and they are reviewed and analysed in a critical literature review.

Design/methodology/approach

Analytical, finite-difference and finite-element methods for modelling intumescent coatings are compared, followed by the definition and quantification of the main physical, thermal, and optical properties of intumescent coatings: swelled thickness, thermal conductivity and resistance, density, specific heat capacity, and emissivity/absorptivity.

Findings

The study highlights the scarce consideration of key influencing factors on the material properties, and the tendency to simplify the problem into effective thermo-physical properties, such as effective thermal conductivity. As a conclusion, the literature review underlines the lack of homogenisation of modelling approaches and material properties, as well as the need for a universal modelling method that can generally simulate the performance of intumescent coatings, combine the large amount of published experimental data, and reliably produce fire-safe performance-based designs.

Research limitations/implications

Due to their limited applicability, high complexity and little comparability, the presented literature review does not focus on analysing and comparing different multi-component models, constituted of many model-specific input parameters. On the contrary, the presented literature review compares various approaches, models and thermo-physical properties which primarily focusses on solving the heat transfer problem through swelling intumescent systems.

Originality/value

The presented literature review analyses and discusses the various modelling approaches to describe and predict the behaviour of swelling intumescent coatings as fire protection for structural materials. Due to the vast variety of available commercial products and potential testing conditions, these data are rarely compared and combined to achieve an overall understanding on the response of intumescent coatings as fire protection measure. The study highlights the lack of information and homogenisation of various modelling approaches, and it underlines the research needs about several aspects related to the intumescent coating behaviour modelling, also providing some useful suggestions for future studies.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 30 May 2023

Renato Silva Nicoletti, Tawan Oliveira, Alex Sander Clemente de Souza and Silvana De Nardin

In the analysis of structures in a fire situation by simplified and analytical methods, one assumption is that the fire resistance time is greater than or equal to the required…

Abstract

Purpose

In the analysis of structures in a fire situation by simplified and analytical methods, one assumption is that the fire resistance time is greater than or equal to the required fire resistance time. Among the methodologies involving the fire resistance time, the most used is the tabular method, which associates fire resistance time values to structural elements based on minimum dimensions of the cross section. The tabular method is widely accepted by the technical-scientific community due to the fact that it is safe and practical. However, its main criticism is that it results in lower fire resistance times than advanced thermal and thermostructural analysis methods. The objective of this study was to evaluate the fire resistance time of reinforced concrete beams and compare it with the required fire resistance time recommended by the tabular method of NBR 15200 (ABNT, 2012).

Design/methodology/approach

The fire resistance time and required fire resistance time of reinforced concrete beams were evaluated using, respectively, numerical models developed based on the finite element method and the tabular method of NBR 15200 (ABNT, 2012). The influence of the following parameters was investigated: longitudinal reinforcement cover, characteristic compressive strength of concrete, beam height, longitudinal reinforcement area and arrangement of steel bars.

Findings

Among the evaluated parameters, the covering of the longitudinal reinforcement proved to be more relevant for the fire resistance time, justifying that the tabular method of NBR 15200 (ABNT, 2012) being strongly and directly influenced by this parameter. In turn, more resistant concretes, higher beams and higher steel grades have lower fire resistance time values. This is because beams in these conditions have greater resistance capacity at room temperature and, consequently, are subject to external stresses of greater magnitude. In some cases, the fire resistance time was even lower than the required fire resistance time prescribed by NBR 15200 (ABNT, 2012). Both the fire resistance time and the required fire resistance time were not influenced by the arrangement of the longitudinal reinforcements.

Originality/value

The present paper innovates by demonstrating the influence of other important design variables on the required fire resistance time of the NBR 15200 (ABNT, 2012). Among several conclusions, it was found that the load level to which the structural elements are subjected considerably affects their fire resistance time. For this reason, it was recommended that the methods for calculating the required fire resistance time consider the load level. In addition, the article quantifies the security degree of the tabular method and exposes some situations for which the tabular method proved to be unsafe. Moreover, in all the models analyzed, the relationship between the span and the vertical deflection associated with the failure of the beams in a fire situation was determined. With this, a span over average deflection relationship was presented in which beams in fire situations fail.

Details

Journal of Structural Fire Engineering, vol. 15 no. 1
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 15 November 2023

Shobod Deba Nath, Gabriel Eweje and Suborna Barua

The purpose of this paper is to investigate why multi-tier apparel suppliers integrate social sustainability practices into their supply chains and what barriers these suppliers…

Abstract

Purpose

The purpose of this paper is to investigate why multi-tier apparel suppliers integrate social sustainability practices into their supply chains and what barriers these suppliers encounter while embedding social sustainability practices.

Design/methodology/approach

This study employs a qualitative research design, drawing on data from semi-structured interviews with 46 owners and managers from 33 multi-tier apparel suppliers in Bangladesh, an important outsourcing hub for the global apparel industry. To corroborate research findings, the views of owners and managers were triangulated by further interviewing 11 key representatives of institutional actors such as third-party auditors, a donor agency, industry associations, regulatory agencies and a non-governmental organisation (NGO).

Findings

The authors' findings suggest a range of divergent institutional drivers and barriers – coercive, mimetic and normative – that determine the implementation of multi-tier suppliers' social sustainability practices. The key reported drivers were buyers' requirements, external stakeholders' expectations, top management commitment and competition. Conversely, cost and resource concerns and gaps in the regulatory framework were identified as key social sustainability implementation barriers. In particular, owners and managers of second-tier and third-tier supplier firms experienced more internal barriers such as cost and resource concerns than external barriers such as gaps in values, learning and commitment (i.e. compromise for mutual benefit and non-disclosure of non-compliance) that impeded effective social sustainability implementation.

Research limitations/implications

Social sustainability in supply chain management has received significant attention from academics, business practitioners, governments, NGOs and supranational organisations. However, limited attention has been paid to investigating the drivers and barriers for social sustainability implementation from a developing country's multi-tier supplier perspective. The authors' research has addressed this knowledge gap.

Practical implications

The evidence from the authors' study provides robust support for key assumptions of institutional theory and has useful implications for both managers and policy-makers.

Originality/value

The authors' study contributes to the embryonic research stream of socially sustainable multi-tier supply chain management by connecting it to the application of institutional theory in a challenging institutional context.

Details

The International Journal of Logistics Management, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 0957-4093

Keywords

Article
Publication date: 16 February 2023

M. Vishal and K.S. Satyanarayanan

This study delineates the effect of cover thickness on reinforced concrete (RC) columns and beams under an elevated fire scenario. Columns and beams are important load-carrying…

Abstract

Purpose

This study delineates the effect of cover thickness on reinforced concrete (RC) columns and beams under an elevated fire scenario. Columns and beams are important load-carrying structural members of buildings. Under all circumstances, the columns and beams were set to be free from damage to avoid structural failure. Under the high-temperature scenario, the RC element may fail because of the material deterioration that occurs owing to the thermal effect. This study attempts to determine the optimum cover thickness for beams and columns under extreme loads and fire conditions.

Design/methodology/approach

Cover thicknesses of 30, 40, 45, 50, 60 and 70 mm for the columns and 10, 20, 25, 30, 35, 40, 50, 60 and 70 mm for the beams were adopted in this study. Both steady-state and transient-state conditions under thermomechanical analysis were performed using the finite element method to determine the heat transfer through the RC section and to determine the effect of thermal stresses.

Findings

The results show that the RC elements have a greater influence on the additional cover thickness at extreme temperatures and higher load ratios than at the service stages. The safe limits of the structural members were obtained under the combined effects of elevated temperatures and structural loads. The results also indicate that the compression members have a better thermal performance than the flexural members.

Research limitations/implications

Numerical investigations concerning the high-temperature behavior of structural elements are useful. The lack of an experimental setup encourages researchers to perform numerical investigations. In this study, the finite element models were validated with existing finite element models and experimental results.

Practical implications

The obtained safe limit for the structural members could help to understand their resistance to fire in a real-time scenario. From the safe limit, a suitable design can be preferred while designing the structural members. This could probably save the structure from collapse.

Originality/value

There is a lack of both numerical and experimental research works. In numerical modeling, the research works found in the literature had difficulties in developing a numerical model that satisfactorily represents the structural members under fire, not being able to adequately understand their behavior at high temperatures. None of them considered the influence of the cover thickness under extreme fire and loading conditions. In this paper, this influence was evaluated and discussed.

Details

Journal of Structural Fire Engineering, vol. 14 no. 4
Type: Research Article
ISSN: 2040-2317

Keywords

Article
Publication date: 16 January 2024

Thomas Pinger, Mirabela Firan and Martin Mensinger

Based on the known positive effects of conventional hot-dip galvanizing under fire exposure and indicative results on zinc–aluminum coatings from smallscale tests, a series of…

15

Abstract

Purpose

Based on the known positive effects of conventional hot-dip galvanizing under fire exposure and indicative results on zinc–aluminum coatings from smallscale tests, a series of tests were conducted on zinc-5% aluminum galvanized test specimens under fire loads to verify the previous positive findings under largescale boundary conditions.

Design/methodology/approach

The emissivity of zinc-5% aluminum galvanized surfaces applied to steel specimens was determined experimentally under real fire loads and laboratory thermal loads in accordance with the normative specifications of the standard fire curve. Both large and smallscale specimens were used in this study. The steel grade and surface conditions of the specimens were varied for both test scenarios.

Findings

Largescale tests on specimens with typical steel construction dimensions under fire loads showed that the surface emissivity of zinc-5% aluminum galvanized steel was significantly lower than that of the conventionally galvanized steel. Only minor influences from the weathering of the specimens and steel chemistry were observed. These results agree well with those obtained from smallscale tests. The design values of zinc-5% aluminum melt (Zn5Al) required for the structural fire design were proposed based on the obtained results.

Originality/value

The novel tests presented in this study are the first ones to study the behavior of zinc-5% aluminum galvanized largescale steel construction components under the influence of real fire exposure and their positive effect on the emissivity of steel components galvanized by this method. The results provide valuable insights and information on the behavior in the case of fire and the associated savings potential for steel construction.

Details

Journal of Structural Fire Engineering, vol. ahead-of-print no. ahead-of-print
Type: Research Article
ISSN: 2040-2317

Keywords

1 – 10 of 738